www.ahlborn.com AIR FLOW 10 Thermoanemometer Type FV A645 TH2/TH3 Type (includes calibration certificate) For flow velocities from 0.1 … 2.000m/s, * max. resolution: 0.001m/s Order No. FVA645TH2 For flow velocities from 0.1 … 15.00m/s, max. resolution: 0.01m/s Order No. FVA645TH3 * up to 1.7 m/s on devices with 24-bit delta-sigma A/D converter (50 Hz) F Probe tube with heated miniature thermistor for flow measurement and highly precise Ni10 temperature sensor for temperature compensation. F Evaluation electronics are located in a separate module housing. F Measurement modules can be directly plugged onto the measuring instruments. F Particularly suitable for low wind velocities, e.g. for draught measurements at work places. Technical Data: 10.08 01/2005 We reserve the right to make technical changes. ☞ When attaching the measuring module other input sockets will be blocked. If the blocked input sockets need to be used or if the module can be directly installed at the measuring location, an extension cable ZA 9060-VKx (maximum length 5m) must be used. Air speed: Accuracy: 0.1 … 0.5m/s: 0.5 … 3.5m/s: 3.5 … 15.0m/s: Temperature: Meas. range: Resolution: Operative range: Compensation: Nominal temperature: Air humidity: Operating voltage: Current consumption: Accessories: Extension cable 2m long Extension cable 4m long Dimensions: Inlet opening: Cable length: Order No. ZA9060VK2 Order No. ZA9060VK4 Module size: ± 0.05m/s ± 0.01m/s ± 3% of final val. ± 0.10m/s ± 3% of final val. –20.0 … 80.0°C 0.1K 0 … 40°C 10 … 36°C 22 °C ± 2K 0 … 90% r.H. (non-condensing) 6 … 13V through ALMEMO® device 50mA (mains adapter for ALMEMO® device is recommended) 300mm long, 8mm Ø 9mm 1.5m with ALMEMO® meas. module 37 x 36 x 22mm 10 AIR FLOW Technical Data: Electronics Box with Sensor Measuring range: FV A605 TA1(O) FV A605 TA5(O) 0.01 to 1m/s 0.15 to 5m/s Resolution: FV A605 TA1(O) FV A605 TA5(O) 0.001m/s 0.01m/s Accuracy: FV A605 TA1(O) FV A605 TA5(O) F Probe tube with heated miniature thermistor for flow measurement and precision NTC resistance for automatic compensation. F Evaluation electronics are located in a separate sensor transmitter module. F High accuracy as a result of integrated temperature compensation and individual calibration in wind tunnel, with laser Doppler anemometer as reference system. F Response time only 2s for smoothing the measured value indicated, optionally without smoothing with 100ms response time. F Suitable for measuring small flow velocities in gaseous substances, particularly for control systems and monitoring. F Typical applications include comfort index measurements, HEVAC applications, environmental technology, clean room technology and process measuring and control technology. ±1.0% of final value and ±1.5% of meas. value ±0.5% of final value ±1.5% of meas. value Nominal conditions: 22°C, 960hPa Automatic temperature compensation: effective in range 0 to 40°C Temperature influence: ±0.5% of fin. value/°C 01/2005 We reserve the right to make technical changes. Thermoelectric Flow Sensor Type FV A605 TA Sensor Head size: Ø 8mm Shaft: Ø 15mm Operative range: 0 to 40°C Angle of attack: FV A605 TA1/TA5 FV A605 TA1O/TA5O ±30° ±180° Inlet opening: FV A605 TAx: FV A605 TAxO: 9mm protecting cage 110mm Sensor length: FV A605 TAx: FV A605 TAxO 300m 310mm Sensor cable length: 1.5m Storage temperature: –30 to +90°C General Technical Specifications A special connector cable allows to connect the flow sensors to all ALMEMO® multi-purpose devices, data loggers and data acquisition systems. For volume flow rate measurements the cross section of the ventilating shaft can be easily entered into ALMEMO® devices. A problem-free averaging is then possible. Types (incl. clamping holder and ALMEMO® connecting cable 1.5m long): Unidirectional (sensitive in one direction) with protected measuring tip Measuring range 0 to 1m/s Order No. FVA605TA1 Measuring range 0 to 5m/s Order No. FVA605TA5 Omnidirectional (direction-independent, symmetrical ball tip) with protecting cage (Ø110mm) including carry-case Measuring range 0 to 1m/s Order No.FVA605TA1O Measuring range 0 to 5m/s Order No.FVA605TA5O Measurement medium: dry air or inert gases Response time: standard: smoothened: 1 τ = 2s option OAA605TAU: not smoothened: 1 τ = 100ms Power supply: through ALMEMO® device (approx. 7… 10V) Current consumption: approx. 70mA Output signal: 0 … 1V, linearised, load resistance min. 10kohms Housing: Dimensions: Protection system: Weight: 100 x 60 x 35mm (L x W x H) IP 40 (aluminium housing) approx. 250g Operating temperature: 0 to 40°C Storage temperature: –30 to 90°C Air humidity: 0 … 90% r.H., non-condensing Adjusting reference: laser Doppler wind tunnel, adjustment at 22°C/approx. 960hPa, (certificate according to SN EN 45001) www.ahlborn.com 10.09 www.ahlborn.com AIR FLOW 10 Thermoanemometer Type MT 84x5 Multi-purpose sensor Types (including calibration / test certificate) Multi-purpose sensor with protected measuring tip, sensitive in one direction Order No. MT8455 Rod sensor with small measuring tip, sensitive in one surface plane Order No. MT8465 Omnisensor with ball tip, sensitive in all directions Order No. MT8475 Rod sensor F Laser-calibrated, highly precise probes with adjustable measuring ranges and standard output signals. F Suitable for use in all fields of air conditioning, ventilating, indoor applications and measurements at work places (draught). Omnisensor A special connector cable allows to connect the thermoanemometers to all ALMEMO® instruments. Please specify the required measuring range in m/s when ordering. Technical Data: Measuring ranges: Output signals: Accuracy: Nominal temperature: 10.10 01/2005 We reserve the right to make technical changes. Temperature influence: Nominal position: Resolution: Reproducibility: Power supply: Current consumption: Output time constant: Operative range: Dimensions: Cable length: Housing: MT8455/MT8465: adjustable from 0.125m/s to 1.0 / 1.25 / 1.5 / 2.0 / 2.5 / 3.0 / 4.0 / 5.0 / 7.5 / 10.0 / 12.5 / 15.0 20.0 / 25.0 / 30.0 / 40.0 / 50.0m/s MT8475: adjustable from 0.05m/s to 0.5 / 0.75 / 1.0 / 1.25 / 1.5 / 2.0 / 2.5m/s 0–5V, 0–10V, 1–5V, 2–10V, 0–20mA, 4–20mA adjustable MT8455/MT8465: ± 2% of meas.val. ±0.5% of selected range MT8475: ± 3% of meas.val. ±1% of selected range MT8455/MT8465: 18–28°C MT8475: 20–26°C MT8455/MT8465: +0.2% per °C drift when out of nominal range MT8475: +0.5% per °C drift when out of nominal range horizontal 0.07% of selected range <±1% of measured value 11 to 30VDC or 18 to 28 VAC max. 350mA selectable from 0.05 to 10s 0 to 60°C Probe 300 mm (75 / 150 / 225 mm also available on request), d = 6.4mm, measuring tip 32mm 5m 126 x 80mm, 60mm high Accessories: ALMEMO® connecting cable 2m long (please specify measuring range in m/s) Rechargeable battery pack 12V / 500mA / 1.5Ah incl. charger for handheld devices ALMEMO® 2290x For use in laboratories mains adapter unit 12V/800mA Small universal stand, suitable for all probes Order No. Order No. Order No. Order No. ZA8400AK ZB2012AP ZB1012NA2 ZX9000ST
© Copyright 2026 Paperzz