UK Distributor of TSI HVAC & Laboratory Control Products Flow Containment, Laboratory Controls, Instrumentation ASHRAE-110 Type-Test Report for 1.2m Wide Bench-Type Fume Hood of GreenLab Ref: ANSI/ASHRAE 110-1995 by Dr A F Bicen Invent UK Ltd 85 Southdown Road Harpenden AL5 1PR Tel: +44 (0) 1582 461666 Fax:+44 (0) 1582 460077 INV/ASHRAE110/713 Date: 6th July 2015 25 YEARS 1988 - 2013 Invent UK Ltd 85 Southdown Road Harpenden, Herts AL5 1PR Telephone: +44 (0) 1582 461666 Facsimile: +44 (0) 1582 460077 E-Mail Address: [email protected] UK Distributor of TSI HVAC & Laboratory Control Products 1. Flow Containment, Laboratory Controls, Instrumentation INTRODUCTION ASHRAE-110 type tests carried out for 1.2m wide bench-type vertical-sash fume hood of GreenLab are reported. General information on test methods, procedures and requirements can be found in reference 1. 2. DESCRIPTION OF TEST ROOM FACILITIES The tests were carried out in Invent UK's test room which is 9.6m long, 4.7m wide and 2.8m high. The tests facilities include a variable-speed extract air system to adjust the extract volume flow rate to the required value. The extract flow rate is measured by a venturimeter with an accuracy of better than 2%. The make-up air was brought in through the perforated ceiling tiles opposite the fume hood so as to allow a test room pressure in the range of -1Pa to -5Pa. The test room differential pressure, temperature, relative humidity and velocity during tests were: Room differential pressure: Room air temperature: Room air relative humidity: Room air velocity: 3. -2Pa 20˚C - 22˚C 50% much less than 0.1 m/s DESCRIPTION OF FUME HOOD The fume hood tested was 1.2m wide bench-type vertical-sash fume hood and designed & built by GreenLab. The sash opening width was 900mm and the test height 500mm from the bottom cill airfoil. Other geometric details of the hood are shown in Figure 1. Figure 1 also shows the fittings, services, outlet controls, taps etc installed on the type tested fume hood. 4. VELOCITY TESTS Velocity tests were performed with the sash set at 500mm from the top of the bottom cill airfoil. The velocity type-test grid for the test opening is shown in Figure 2. Figure 2 also shows the velocity test results. 5. FLOW VISUALISATION TESTS The following observations were made: Along the opening edge = GOOD Top LHS corner = GOOD Top RHS corner = GOOD Bottom LHS corner = GOOD Bottom RHS corner = GOOD 6. CONTAINMENT TESTS 6.1 Static Sash Tests The containment tests were performed for the same opening as in the velocity test. Figure 3 shows the positioning of the containment test system with respect to the test opening. Figure 3 also summarises the results and shows that the hood containment performance is very good. 6.2 Scanning of Static Sash Openings Traversing of the sampling probe along the edges of the test opening resulted in SF6 levels less than 0.020ppm. 25 YEARS 1988 - 2013 Invent UK Ltd 85 Southdown Road Harpenden, Herts AL5 1PR Telephone: +44 (0) 1582 461666 Facsimile: +44 (0) 1582 460077 E-Mail Address: [email protected] UK Distributor of TSI HVAC & Laboratory Control Products Flow Containment, Laboratory Controls, Instrumentation REFERENCES 1. ANSI/ASHRAE 110-1995, ASHRAE Guideline, Method of Testing Performance of Laboratory Fume Hoods, 1995. List of instrumentation used during tests: 1. Miran 205-B infrared gas analyser - SN: 76185-382 (containment tests) 2. M+W Inst D-5110 flow meter - SN: 1309-50H0030-By (test gas flow rate metering) 3. VelociCalc 9545-A - SN: 0713014 (velocity tests) 4. Furness Control micromanometer (pressure drop test) 25 YEARS 1988 - 2013 Invent UK Ltd 85 Southdown Road Harpenden, Herts AL5 1PR Telephone: +44 (0) 1582 461666 Facsimile: +44 (0) 1582 460077 E-Mail Address: [email protected] UK Distributor of TSI HVAC & Laboratory Control Products Flow Containment, Laboratory Controls, Instrumentation & Plastic Fans A A A EXTERNAL DIMENSIONS: Height = 2400 Width = 1200mm Depth = 900mm BAFFLE DIMENSIONS: Top gap: 25mm (vertical) Bottom gap: 200mm (vertical) Baffle gap: 55mm (from back wall) INTERNAL DIMENSIONS: Height = 1060mm (max) Width = 1100mm Depth = 660mm (back wall-sash) 600mm (baffle-sash) OTHER DIMENSIONS: Cill gap: 20mm (min) Sash gap: 25mm Figure 1 Geometric features of 1.2m bench-type fume hood of GreenLab 25 YEARS 1988 - 2013 Invent UK Ltd 85 Southdown Road Harpenden, Herts AL5 1PR Telephone: +44 (0) 1582 461666 Facsimile: +44 (0) 1582 460077 E-Mail Address: [email protected] UK Distributor of TSI HVAC & Laboratory Control Products Flow Containment, Laboratory Controls, Instrumentation & Plastic Fans AA AA AA VelociCalc 0.50 150mm 125mm 01 03 05 02 04 06 AA AA AA Grid point Mean velocity (m/s) 01 0.50 03 0.48 05 0.50 Grid point Mean velocity (m/s) 02 0.54 04 0.52 06 0.52 Average Face Velocity = 0.51m/s Figure 2 ASHRAE-110 velocity type-test grid & results. 25 YEARS 1988 - 2013 Invent UK Ltd 85 Southdown Road Harpenden, Herts AL5 1PR Telephone: +44 (0) 1582 461666 Facsimile: +44 (0) 1582 460077 E-Mail Address: [email protected] UK Distributor of TSI HVAC & Laboratory Control Products Flow Containment, Laboratory Controls, Instrumentation & Plastic Fans The mannequin is at 100mm away from the sash plane and positioned at location shown below. The sampling probe is at the breathing zone of the mannequin and 75mm away from the sash plane. The test gas injector is positioned on the work top at location shown below. The injector is at 150mm in from the sash plane. The test gas is 100% SF6. The test gas flow rate is 4.0lt/min. 300mm CL 300mm P1 P2 P3 AA AA AA POSITION P1 POSITION P2 POSITION P3 Mean SF6 Concentration Mean SF6 Concentration Mean SF6 Concentration <0.020ppm+ <0.020ppm+ <0.020ppm+ + the minimum detection level of the test system, including background SF6. Figure 3 Positioning of ASHRAE-110 containment test system and results. 25 YEARS 1988 - 2013 Invent UK Ltd 85 Southdown Road Harpenden, Herts AL5 1PR Telephone: +44 (0) 1582 461666 Facsimile: +44 (0) 1582 460077 E-Mail Address: [email protected] ANSI/ASHRAE 110-1995 Flow Containment & Instrumentation CERTIFICATE OF TYPE TESTING IN ACCORDANCE WITH ASHRAE 110-1995 CERTIFICATE & REPORT NO: INV/ASHRAE110/713 DATE: 6th July 2015 Fume Hood Manufacturer: GreenLab Omerli Mah Koskoop San Sitesi Misir Sokak No: 7 Hadimkoy - Istanbul TURKEY Fume Hood Type: 1.2m wide bench-type vertical-sash External Dimensions: Height = 2400mm Width = 1200mm Depth = 900mm Internal Dimensions: Height = 1060mm Width = 1100mm Depth = 660mm (wall-sash) 600mm (baffle-sash) Baffle Gap Dimensions: Top gap: 25mm Bottom gap: 200mm ED 15 07/ / 6 0 I I C E RT F Test Opening: Width: 900mm Height: 500mm Fume Hood Flow: Flow rate: 0.250m3/s Face velocity: 0.51m/s Press drop: 120Pa (at 200mmD) Fume Hood Containment: Position P1: <0.020ppm Position P2: <0.020ppm Position P3: <0.020ppm Edge scan: <0.020ppm This is to certify that the fume hood described above has been typetested in accordance with ASHRAE 110-1995 and resulted in performance characteristics given in the corresponding test report. Tested and Certified by: Dr A F Bicen Invent UK Ltd, 85 Southdown Road, Harpenden, Herts AL5 1PR T: +44 (0) 1582 461666 F: +44 (0) 1582 460077 E: [email protected]
© Copyright 2026 Paperzz