PHOTOMETRIC REFERENCE SHEET Fixture Family IES FILE LYNK SFBL 2F54 120 (Bare Lamp) SFST 2F54 120 (Symmetric Solid Reflector) SFPT 2F54 120 (Symmetric Perforated Shield) SFSP 2F54 120 (Symmetric Solid Perforated Shield) SFSB 2F54 120 (Standoff Symmetric Solid Shield) SFPP 2F54 120 (Symmetric Perforated Perforated Shield) SFPB 2F54 120 (Standoff Symmetric Perforated Shield) SFFT 2F54 120 (Forward Throw Perforated) LV4 2F54 120 (White Blade Louver) ITL 64272 ITL 64267 ITL 64268 ITL 64806 ITL 64813 ITL 64807 ITL 64812 ITL 71375 ITL 64271 www.specspi.com www.specadvent.com www.specstile.com INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL64272 DATE: 03/04/10 PREPARED FOR: SPI LIGHTING, INC. CATALOG NUMBER: SIP10939-2F54 LUMINAIRE: EXTRUDED WHITE PAINTED METAL BALLAST HOUSING WITH FABRICATED WHITE PAINTED METAL SOCKET MOUNTING ASSEMBLIES/END CAPS, ONE FABRICATED CYLINDRICAL WHITE PAINTED METAL COLLAR AROUND EACH END OF LAMPS, OPEN TOP, BOTTOM AND SIDES. LAMPS: TWO 54-WATT T-5 SYLVANIA FP54/835/HO/ECO LINEAR FLUORESCENTS. BALLAST: ADVANCE ICN-2S54 MOUNTING: SUSPENDED THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL INPUT WATTS = 121.9 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED = 9.17 REPORT IS BASED ON 5000 LUMENS PER LAMP. * CANDELA DISTRIBUTION 0.0 22.5 45.0 0 1224 1224 1224 5 1224 1224 1224 15 1178 1186 1205 25 1086 1108 1165 35 954 1004 1110 45 789 875 1046 55 599 726 974 65 390 580 912 75 190 449 838 85 28 201 429 90 0 174 418 95 32 248 426 105 203 447 846 115 407 570 897 125 603 718 951 135 788 855 1014 145 945 986 1078 155 1065 1085 1127 165 1148 1152 1166 175 1188 1186 1187 180 1187 1187 1187 ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 995 0- 40 1689 0- 60 3348 0- 90 5357 90-120 2034 90-130 2875 90-150 4333 90-180 5297 0-180 10654 FLUX 67.5 1224 1224 1222 1217 1209 1200 1188 1181 862 601 596 601 930 1157 1161 1163 1170 1173 1178 1184 1187 90.0 1224 1224 1230 1240 1251 1260 1270 1281 866 664 661 664 937 1254 1241 1222 1206 1191 1186 1186 1187 117 341 538 694 801 858 871 691 447 450 727 857 841 782 676 521 330 113 180˚ 165˚ 150˚ 135˚ 1200 120˚ 600 105˚ 90˚ 75˚ %LAMP 10.0 16.9 33.5 53.6 20.3 28.8 43.3 53.0 106.5 TOTAL LUMINAIRE EFFICIENCY = %FIXT 9.3 15.9 31.4 50.3 19.1 27.0 40.7 49.7 100.0 106.5 % * CIE TYPE - DIRECT-INDIRECT PLANE : 0-DEG 90-DEG SPACING CRITERIA : 1.2 1.6 SHIELDING ANGLES : 0 0 600 60˚ 1200 0˚ 15˚ LEGEND: 0-deg: 45-deg: 90-deg: 30˚ Checked R HUMPHREYS Approved R BERGIN 45˚ * SEE ADDENDUM FOR FURTHER INFORMATION THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] REPORT NUMBER: ITL64272 PREPARED FOR: SPI LIGHTING, INC. CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 1224 1224 1224 5.0 1224 1224 1224 10.0 1207 1210 1218 15.0 1178 1186 1205 20.0 1138 1152 1187 25.0 1086 1108 1165 30.0 1026 1059 1139 35.0 954 1004 1110 40.0 874 942 1077 45.0 789 875 1046 50.0 697 803 1011 55.0 599 726 974 60.0 498 651 942 65.0 390 580 912 70.0 286 509 886 75.0 190 449 838 80.0 101 394 517 85.0 28 201 429 90.0 0 174 418 95.0 32 248 426 100.0 104 395 578 105.0 203 447 846 110.0 304 504 871 115.0 407 570 897 120.0 507 643 924 125.0 603 718 951 130.0 699 790 983 135.0 788 855 1014 140.0 871 923 1047 145.0 945 986 1078 150.0 1010 1038 1104 155.0 1065 1085 1127 160.0 1112 1123 1149 165.0 1148 1152 1166 170.0 1173 1173 1179 175.0 1188 1186 1187 180.0 1187 1187 1187 67.5 1224 1224 1223 1222 1220 1217 1213 1209 1206 1200 1193 1188 1185 1181 1165 862 615 601 596 601 640 930 1155 1157 1159 1161 1161 1163 1166 1170 1171 1173 1174 1178 1181 1184 1187 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA 90.0 1224 1224 1227 1230 1236 1240 1245 1251 1258 1260 1263 1270 1276 1281 1206 866 675 664 661 664 676 937 1238 1254 1249 1241 1231 1222 1213 1206 1198 1191 1187 1186 1186 1186 1187 • WEBSITE: www.itlboulder.com DATE: 03/04/10 ZONAL LUMEN SUMMARY 0- 5 29. 5- 10 87. 10- 15 144. 15- 20 197. 20- 25 246. 25- 30 291. 30- 35 330. 35- 40 364. 40- 45 391. 45- 50 411. 50- 55 425. 55- 60 433. 60- 65 436. 65- 70 435. 70- 75 395. 75- 80 296. 80- 85 237. 85- 90 210. 90- 95 209. 95-100 241. 100-105 322. 105-110 405. 110-115 428. 115-120 429. 120-125 425. 125-130 416. 130-135 401. 135-140 380. 140-145 354. 145-150 321. 150-155 283. 155-160 239. 160-165 191. 165-170 139. 170-175 85. 175-180 28. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64272 WEBSITE: www.itlboulder.com DATE: 03/04/10 PREPARED FOR: SPI LIGHTING, INC. COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 0 1 2 3 4 5 6 7 8 9 10 114114114114 102 96 91 87 92 83 75 69 83 72 63 56 75 63 53 46 69 55 46 39 63 49 40 34 58 44 35 29 54 40 31 25 50 37 28 22 47 33 25 20 105105105105 94 89 84 80 84 76 69 64 76 66 58 52 69 58 50 43 63 51 43 36 58 46 37 31 53 41 33 27 49 37 29 24 46 34 26 21 43 31 24 19 50 50 30 10 30 50 30 10 10 50 30 10 0 0 89 75 64 55 48 43 38 35 31 29 26 74 61 52 45 40 35 32 29 26 24 22 60 49 42 36 32 28 25 23 21 19 18 54 40 32 26 21 18 15 13 12 10 9 89 71 59 49 42 36 32 28 25 23 20 89 68 54 44 37 31 27 23 21 18 16 74 59 49 41 35 30 27 24 21 19 17 74 57 45 37 31 26 23 20 17 15 14 60 48 39 33 28 24 21 19 17 16 14 60 46 37 30 25 21 18 16 14 13 11 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] REPORT NUMBER: ITL64272 PREPARED FOR: SPI LIGHTING, INC. • WEBSITE: www.itlboulder.com DATE: 03/04/10 ADDENDUM -------SPECIAL TEST PROCEDURES FOR T-5 LAMPS INCLUDING EXPLANATION OF THE IMPORTANCE OF LAMP LUMEN RATINGS. -----------------------------------------------------------------This test was performed using standard relative photometric practices in accordance with recommendations of the Illuminating Engineering Society of North America. Fluorescent testing using the guidelines of relative photometric practice presupposes that the lamps will be operated at their nominal electrical characteristics (e.g., a 40 watt lamp will operate very nearly at 40 watts, and at the voltage and current required for 40-watt operation). Fluorescent lamps in general are temperature sensitive, the lumen output varies with ambient temperature and follows a characteristic curve. The T-5 fluorescent lamps used in this test produce maximum light output in an ambient temperature other than 25 degrees C. A critical step in relative photometric testing involves measurement of the total flux output from the lamp(s) suspended in free air at a 25 degree C ambient temperature per IES LM41-1998. This measurement process is a separate step from the photometric exploration of the luminaire itself. This "bare lamp" measurement is made with the lamp(s) operated by the same ballast(s) which are to be used in the luminaire. Since the test procedure involves measuring the bare lamp flux output at 25 degrees C and this lamp type peaks at a temperature other than 25 degrees C, the flux measured for this lamp type will be less than the maximum output the lamp is designed to produce. As a result, the measurement of the "bare lamp" total flux output is lower than it would be if they were operated at their optimum operating temperature and at nominal electrical characteristics. When this "bare lamp" measurement is incorporated into the luminaire test report, the net effect is that the candela values on the luminaire test report are higher than what the luminaire actually produced and the total luminaire efficiency is higher than what the lighting industry would expect this luminaire to produce. These lighting industry expectations are based on comparisons to the total luminaire efficiency of the same luminaire with T-12 or T-8 lamps. On this particular test, the lamp lumen rating shown is for a 35 degree C ambient temperature. T5TEMP.DIS THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL64267 DATE: 02/25/10 PREPARED FOR: SPI LIGHTING, INC. CATALOG NUMBER: SIP10939-2F54-SSR LUMINAIRE: EXTRUDED WHITE PAINTED METAL BALLAST HOUSING WITH FABRICATED WHITE PAINTED METAL SOCKET MOUNTING ASSEMBLIES/END CAPS, ONE FORMED WHITE PAINTED METAL REFLECTOR WITH ONE FORMED WHITE PAINTED METAL COVER ABOVE EACH LAMP, OPEN BOTTOM. LAMPS: TWO 54-WATT T-5 SYLVANIA FP54/835/HO/ECO LINEAR FLUORESCENTS. BALLAST: ADVANCE ICN-2S54 MOUNTING: SUSPENDED THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL INPUT WATTS = 114.4 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED = 9.17 REPORT IS BASED ON 5000 LUMENS PER LAMP. * CANDELA DISTRIBUTION 0.0 22.5 45.0 0 2963 2963 2963 5 2965 2954 2949 15 2865 2858 2867 25 2673 2674 2695 35 2395 2418 2421 45 2052 2069 2056 55 1619 1634 1637 65 1134 1147 1116 75 610 627 593 85 93 96 78 90 0 5 8 95 2 2 3 105 2 3 2 115 3 3 4 125 4 5 5 135 6 5 6 145 7 6 7 155 7 7 7 165 8 7 7 175 8 8 8 180 8 8 8 FLUX 67.5 2963 2943 2869 2698 2422 2072 1628 1103 589 81 13 5 2 6 6 7 7 7 8 8 8 ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 2332 0- 40 3846 0- 60 6900 0- 90 8729 90-120 10 90-130 15 90-150 24 90-180 31 0-180 8759 90.0 2963 2941 2876 2704 2419 2084 1619 1080 530 77 12 6 1 5 7 7 7 8 8 9 8 %LAMP 23.3 38.5 69.0 87.3 0.1 0.2 0.2 0.3 87.6 TOTAL LUMINAIRE EFFICIENCY = CIE TYPE - DIRECT PLANE : 0-DEG SPACING CRITERIA : 1.3 SHIELDING ANGLES : 1 281 810 1242 1514 1593 1461 1111 609 109 4 2 4 5 5 4 3 2 1 %FIXT 26.6 43.9 78.8 99.7 0.1 0.2 0.3 0.3 100.0 87.6 % * 90-DEG 1.3 0 90˚ 75˚ 1000 60˚ 2000 45˚ 3000 0˚ LEGEND: 0-deg: 45-deg: 90-deg: 15˚ 30˚ Checked R HUMPHREYS Approved R BERGIN * SEE ADDENDUM FOR FURTHER INFORMATION THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] REPORT NUMBER: ITL64267 PREPARED FOR: SPI LIGHTING, INC. CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 2963 2963 2963 5.0 2965 2954 2949 10.0 2927 2918 2915 15.0 2865 2858 2867 20.0 2782 2776 2794 25.0 2673 2674 2695 30.0 2543 2550 2569 35.0 2395 2418 2421 40.0 2229 2254 2242 45.0 2052 2069 2056 50.0 1841 1862 1846 55.0 1619 1634 1637 60.0 1388 1397 1394 65.0 1134 1147 1116 70.0 870 901 840 75.0 610 627 593 80.0 327 348 273 85.0 93 96 78 90.0 0 5 8 95.0 2 2 3 100.0 2 3 1 105.0 2 3 2 110.0 2 3 5 115.0 3 3 4 120.0 4 4 5 125.0 4 5 5 130.0 5 5 5 135.0 6 5 6 140.0 6 6 7 145.0 7 6 7 150.0 7 7 7 155.0 7 7 7 160.0 7 7 7 165.0 8 7 7 170.0 8 8 8 175.0 8 8 8 180.0 8 8 8 67.5 2963 2943 2915 2869 2800 2698 2567 2422 2253 2072 1878 1628 1364 1103 844 589 195 81 13 5 2 2 3 6 6 6 6 7 7 7 8 7 7 8 8 8 8 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA 90.0 2963 2941 2915 2876 2807 2704 2575 2419 2248 2084 1870 1619 1349 1080 819 530 181 77 12 6 1 1 2 5 7 7 6 7 7 7 8 8 8 8 9 9 8 • WEBSITE: www.itlboulder.com DATE: 02/25/10 ZONAL LUMEN SUMMARY 0- 5 71. 5- 10 210. 10- 15 343. 15- 20 467. 20- 25 575. 25- 30 666. 30- 35 735. 35- 40 779. 40- 45 798. 45- 50 795. 50- 55 760. 55- 60 700. 60- 65 611. 65- 70 500. 70- 75 381. 75- 80 228. 80- 85 90. 85- 90 19. 90- 95 3. 95-100 1. 100-105 1. 105-110 1. 110-115 2. 115-120 2. 120-125 2. 125-130 2. 130-135 2. 135-140 2. 140-145 2. 145-150 2. 150-155 2. 155-160 1. 160-165 1. 165-170 1. 170-175 1. 175-180 0. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64267 WEBSITE: www.itlboulder.com DATE: 02/25/10 PREPARED FOR: SPI LIGHTING, INC. COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 0 1 2 3 4 5 6 7 8 9 10 104104104104 95 91 87 84 87 79 73 68 79 69 62 57 72 61 54 48 66 55 47 41 61 49 41 36 57 45 37 31 53 41 33 28 49 37 30 25 46 34 27 23 102102102102 93 89 86 83 84 78 72 67 77 68 61 56 70 60 53 47 64 54 46 41 59 48 41 36 55 44 37 31 51 40 33 28 48 37 30 25 45 34 27 23 50 50 30 10 30 50 30 10 10 50 30 10 0 0 97 85 74 65 58 52 47 42 39 36 33 93 82 72 63 56 50 45 41 38 35 32 89 79 69 61 54 48 44 40 37 34 31 87 73 61 51 43 37 33 29 26 23 21 97 83 70 60 52 45 40 36 32 29 27 97 80 66 55 47 40 35 31 28 25 23 93 80 68 58 50 44 39 35 32 29 26 93 78 64 54 46 40 35 31 27 25 22 89 77 66 57 49 43 39 35 31 28 26 89 75 63 53 45 39 34 31 27 25 22 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] REPORT NUMBER: ITL64267 PREPARED FOR: SPI LIGHTING, INC. • WEBSITE: www.itlboulder.com DATE: 02/25/10 ADDENDUM -------SPECIAL TEST PROCEDURES FOR T-5 LAMPS INCLUDING EXPLANATION OF THE IMPORTANCE OF LAMP LUMEN RATINGS. -----------------------------------------------------------------This test was performed using standard relative photometric practices in accordance with recommendations of the Illuminating Engineering Society of North America. Fluorescent testing using the guidelines of relative photometric practice presupposes that the lamps will be operated at their nominal electrical characteristics (e.g., a 40 watt lamp will operate very nearly at 40 watts, and at the voltage and current required for 40-watt operation). Fluorescent lamps in general are temperature sensitive, the lumen output varies with ambient temperature and follows a characteristic curve. The T-5 fluorescent lamps used in this test produce maximum light output in an ambient temperature other than 25 degrees C. A critical step in relative photometric testing involves measurement of the total flux output from the lamp(s) suspended in free air at a 25 degree C ambient temperature per IES LM41-1998. This measurement process is a separate step from the photometric exploration of the luminaire itself. This "bare lamp" measurement is made with the lamp(s) operated by the same ballast(s) which are to be used in the luminaire. Since the test procedure involves measuring the bare lamp flux output at 25 degrees C and this lamp type peaks at a temperature other than 25 degrees C, the flux measured for this lamp type will be less than the maximum output the lamp is designed to produce. As a result, the measurement of the "bare lamp" total flux output is lower than it would be if they were operated at their optimum operating temperature and at nominal electrical characteristics. When this "bare lamp" measurement is incorporated into the luminaire test report, the net effect is that the candela values on the luminaire test report are higher than what the luminaire actually produced and the total luminaire efficiency is higher than what the lighting industry would expect this luminaire to produce. These lighting industry expectations are based on comparisons to the total luminaire efficiency of the same luminaire with T-12 or T-8 lamps. On this particular test, the lamp lumen rating shown is for a 35 degree C ambient temperature. T5TEMP.DIS THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL64268 DATE: 02/26/10 PREPARED FOR: SPI LIGHTING, INC. CATALOG NUMBER: SIP10939-2F54-SPS (40% OPEN) LUMINAIRE: EXTRUDED WHITE PAINTED METAL BALLAST HOUSING WITH FABRICATED WHITE PAINTED METAL SOCKET MOUNTING ASSEMBLIES/END CAPS, ONE FORMED WHITE PAINTED PERFORATED METAL DIFFUSER ABOVE EACH LAMP, OPEN BOTTOM. LAMPS: TWO 54-WATT T-5 SYLVANIA FP54/835/HO/ECO LINEAR FLUORESCENTS. BALLAST: ADVANCE ICN-2S54 MOUNTING: SUSPENDED THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL INPUT WATTS = 121.7 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED = 9.17 REPORT IS BASED ON 5000 LUMENS PER LAMP. * CANDELA DISTRIBUTION 0.0 22.5 45.0 0 2092 2092 2092 5 2089 2088 2082 15 2019 2021 2035 25 1884 1895 1942 35 1684 1727 1793 45 1437 1497 1594 55 1137 1216 1362 65 808 909 1045 75 457 550 674 85 97 113 210 90 0 43 168 95 6 74 180 105 60 181 389 115 192 254 448 125 323 342 484 135 439 441 512 145 533 536 563 155 608 611 620 165 662 661 665 175 689 687 687 180 687 687 687 FLUX 67.5 2092 2079 2049 1979 1856 1695 1480 1177 707 300 267 274 472 612 620 614 608 633 666 687 687 90.0 2092 2080 2061 2000 1881 1743 1511 1211 687 328 307 312 499 671 668 656 627 640 665 686 687 198 576 896 1122 1230 1207 1024 647 245 194 348 430 435 409 359 287 188 65 180˚ 165˚ 150˚ 135˚ 2000 120˚ 1000 105˚ 90˚ 75˚ ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 1670 0- 40 2792 0- 60 5229 0- 90 7145 90-120 972 90-130 1408 90-150 2176 90-180 2716 0-180 9861 %LAMP 16.7 27.9 52.3 71.5 9.7 14.1 21.8 27.2 98.6 TOTAL LUMINAIRE EFFICIENCY = CIE TYPE - SEMI-DIRECT PLANE : 0-DEG SPACING CRITERIA : 1.3 SHIELDING ANGLES : 1 %FIXT 16.9 28.3 53.0 72.5 9.9 14.3 22.1 27.5 100.0 98.6 % * 90-DEG 1.4 0 1000 60˚ 2000 0˚ 15˚ LEGEND: 0-deg: 45-deg: 90-deg: 30˚ Checked R HUMPHREYS Approved R BERGIN 45˚ * SEE ADDENDUM FOR FURTHER INFORMATION THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] REPORT NUMBER: ITL64268 PREPARED FOR: SPI LIGHTING, INC. CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 2092 2092 2092 5.0 2089 2088 2082 10.0 2064 2062 2064 15.0 2019 2021 2035 20.0 1958 1966 1996 25.0 1884 1895 1942 30.0 1790 1815 1873 35.0 1684 1727 1793 40.0 1565 1619 1697 45.0 1437 1497 1594 50.0 1296 1368 1478 55.0 1137 1216 1362 60.0 980 1065 1225 65.0 808 909 1045 70.0 633 743 869 75.0 457 550 674 80.0 271 341 373 85.0 97 113 210 90.0 0 43 168 95.0 6 74 180 100.0 25 144 268 105.0 60 181 389 110.0 122 220 428 115.0 192 254 448 120.0 261 295 473 125.0 323 342 484 130.0 384 393 493 135.0 439 441 512 140.0 491 492 538 145.0 533 536 563 150.0 576 577 591 155.0 608 611 620 160.0 639 640 645 165.0 662 661 665 170.0 679 678 680 175.0 689 687 687 180.0 687 687 687 67.5 2092 2079 2068 2049 2020 1979 1923 1856 1775 1695 1611 1480 1327 1177 982 707 390 300 267 274 336 472 584 612 613 620 624 614 606 608 620 633 651 666 679 687 687 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA 90.0 2092 2080 2073 2061 2033 2000 1947 1881 1807 1743 1653 1511 1370 1211 980 687 414 328 307 312 338 499 633 671 676 668 670 656 638 627 633 640 652 665 679 686 687 • WEBSITE: www.itlboulder.com DATE: 02/26/10 ZONAL LUMEN SUMMARY 0- 5 50. 5- 10 149. 10- 15 243. 15- 20 332. 20- 25 413. 25- 30 483. 30- 35 540. 35- 40 582. 40- 45 608. 45- 50 622. 50- 55 616. 55- 60 591. 60- 65 545. 65- 70 479. 70- 75 388. 75- 80 258. 80- 85 149. 85- 90 96. 90- 95 89. 95-100 105. 100-105 152. 105-110 196. 110-115 212. 115-120 218. 120-125 219. 125-130 216. 130-135 210. 135-140 199. 140-145 187. 145-150 172. 150-155 154. 155-160 133. 160-165 108. 165-170 80. 170-175 49. 175-180 16. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64268 WEBSITE: www.itlboulder.com DATE: 02/26/10 PREPARED FOR: SPI LIGHTING, INC. COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 0 1 2 3 4 5 6 7 8 9 10 111111111111 100 95 91 87 91 82 76 70 82 72 64 57 75 63 54 48 69 56 47 41 63 50 41 35 58 45 37 31 54 41 33 27 50 37 29 24 47 34 27 22 105105105105 95 90 87 83 85 78 72 67 77 68 61 55 71 60 52 46 65 53 45 39 59 48 40 34 55 43 35 30 51 39 31 26 48 36 28 23 45 33 26 21 50 50 30 10 30 50 30 10 10 50 30 10 0 0 94 81 70 61 54 48 43 39 36 33 30 85 73 63 55 49 43 39 35 32 30 27 76 65 56 49 44 39 35 32 29 27 25 71 58 47 39 33 28 24 21 19 17 15 94 78 65 55 48 41 37 32 29 26 24 94 76 61 51 43 36 31 28 24 22 20 85 71 59 50 43 38 33 30 27 24 22 85 68 56 46 39 34 29 26 23 20 18 76 63 53 45 39 34 30 27 25 22 20 76 62 51 42 36 31 27 24 21 19 17 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] REPORT NUMBER: ITL64268 PREPARED FOR: SPI LIGHTING, INC. • WEBSITE: www.itlboulder.com DATE: 02/26/10 ADDENDUM -------SPECIAL TEST PROCEDURES FOR T-5 LAMPS INCLUDING EXPLANATION OF THE IMPORTANCE OF LAMP LUMEN RATINGS. -----------------------------------------------------------------This test was performed using standard relative photometric practices in accordance with recommendations of the Illuminating Engineering Society of North America. Fluorescent testing using the guidelines of relative photometric practice presupposes that the lamps will be operated at their nominal electrical characteristics (e.g., a 40 watt lamp will operate very nearly at 40 watts, and at the voltage and current required for 40-watt operation). Fluorescent lamps in general are temperature sensitive, the lumen output varies with ambient temperature and follows a characteristic curve. The T-5 fluorescent lamps used in this test produce maximum light output in an ambient temperature other than 25 degrees C. A critical step in relative photometric testing involves measurement of the total flux output from the lamp(s) suspended in free air at a 25 degree C ambient temperature per IES LM41-1998. This measurement process is a separate step from the photometric exploration of the luminaire itself. This "bare lamp" measurement is made with the lamp(s) operated by the same ballast(s) which are to be used in the luminaire. Since the test procedure involves measuring the bare lamp flux output at 25 degrees C and this lamp type peaks at a temperature other than 25 degrees C, the flux measured for this lamp type will be less than the maximum output the lamp is designed to produce. As a result, the measurement of the "bare lamp" total flux output is lower than it would be if they were operated at their optimum operating temperature and at nominal electrical characteristics. When this "bare lamp" measurement is incorporated into the luminaire test report, the net effect is that the candela values on the luminaire test report are higher than what the luminaire actually produced and the total luminaire efficiency is higher than what the lighting industry would expect this luminaire to produce. These lighting industry expectations are based on comparisons to the total luminaire efficiency of the same luminaire with T-12 or T-8 lamps. On this particular test, the lamp lumen rating shown is for a 35 degree C ambient temperature. T5TEMP.DIS THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL64806 DATE: 05/24/10 PREPARED FOR: SPI LIGHTING, INC. CATALOG NUMBER: SIP10939-2F54-SSPS (STANDOFF) LUMINAIRE: EXTRUDED WHITE PAINTED METAL BALLAST HOUSING WITH FABRICATED WHITE PAINTED METAL SOCKET MOUNTING ASSEMBLIES/END CAPS, ONE BLACK PAINTED MACHINED METAL STANDOFF ABOVE EACH SOCKET HOUSING, ONE FORMED WHITE PAINTED METAL REFLECTOR ABOVE EACH LAMP, ONE FORMED WHITE PAINTED PERFORATED METAL DIFFUSER BELOW EACH LAMP. LAMPS: TWO 54-WATT T-5 SYLVANIA FP54/835/HO/ECO LINEAR FLUORESCENTS. BALLAST: ADVANCE ICN-2S54 MOUNTING: SUSPENDED THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL INPUT WATTS = 117.0 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED = 9.17 REPORT IS BASED ON 5000 LUMENS PER LAMP. * CANDELA DISTRIBUTION 0.0 22.5 45.0 0 2570 2570 2570 5 2570 2567 2560 15 2470 2471 2467 25 2288 2295 2284 35 2047 2031 2066 45 1728 1708 1800 55 1362 1347 1501 65 954 942 1092 75 513 519 629 85 98 125 251 90 0 45 148 95 4 15 72 105 9 31 20 115 12 30 49 125 15 29 54 135 17 28 46 145 19 28 39 155 23 26 37 165 28 30 31 175 31 31 31 180 31 31 31 FLUX 67.5 2570 2554 2466 2304 2122 1899 1601 1101 667 326 210 113 34 46 69 59 49 42 35 32 31 ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 1999 0- 40 3301 0- 60 6024 0- 90 7960 90-120 149 90-130 191 90-150 248 90-180 277 0-180 8237 90.0 2570 2555 2464 2319 2156 1945 1619 1132 676 350 250 148 41 38 68 65 51 42 37 31 31 %LAMP 20.0 33.0 60.2 79.6 1.5 1.9 2.5 2.8 82.4 TOTAL LUMINAIRE EFFICIENCY = CIE TYPE - DIRECT PLANE : 0-DEG SPACING CRITERIA : 1.3 SHIELDING ANGLES : 90 243 696 1060 1302 1398 1325 1038 634 264 90˚ 81 31 37 42 34 24 16 9 3 %FIXT 24.3 40.1 73.1 96.6 1.8 2.3 3.0 3.4 100.0 82.4 % * 90-DEG 1.3 90 * SEE ADDENDUM FOR FURTHER INFORMATION 75˚ 900 60˚ 1800 45˚ 2700 0˚ LEGEND: 0-deg: 45-deg: 90-deg: 15˚ Checked B HYRE Approved R BEATTIE 30˚ THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] REPORT NUMBER: ITL64806 PREPARED FOR: SPI LIGHTING, INC. CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 2570 2570 2570 5.0 2570 2567 2560 10.0 2531 2530 2526 15.0 2470 2471 2467 20.0 2394 2394 2386 25.0 2288 2295 2284 30.0 2170 2169 2175 35.0 2047 2031 2066 40.0 1892 1874 1943 45.0 1728 1708 1800 50.0 1551 1537 1655 55.0 1362 1347 1501 60.0 1159 1150 1329 65.0 954 942 1092 70.0 737 742 826 75.0 513 519 629 80.0 298 282 387 85.0 98 125 251 90.0 0 45 148 95.0 4 15 72 100.0 7 20 32 105.0 9 31 20 110.0 11 32 36 115.0 12 30 49 120.0 13 29 57 125.0 15 29 54 130.0 16 28 49 135.0 17 28 46 140.0 18 28 42 145.0 19 28 39 150.0 20 26 37 155.0 23 26 37 160.0 26 28 35 165.0 28 30 31 170.0 30 31 32 175.0 31 31 31 180.0 31 31 31 67.5 2570 2554 2522 2466 2387 2304 2218 2122 2011 1899 1782 1601 1359 1101 907 667 453 326 210 113 53 34 28 46 59 69 65 59 54 49 44 42 40 35 33 32 31 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA • WEBSITE: www.itlboulder.com DATE: 05/24/10 90.0 2570 2555 2523 2464 2390 2319 2239 2156 2054 1945 1818 1619 1371 1132 952 676 486 350 250 148 72 41 27 38 55 68 72 65 58 51 45 42 41 37 31 31 31 THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64806 PREPARED FOR: SPI LIGHTING, INC. WEBSITE: www.itlboulder.com 5-DEGREE ZONAL LUMEN SUMMARY 0- 5 61. 5- 10 182. 10- 15 296. 15- 20 400. 20- 25 491. 25- 30 568. 30- 35 629. 35- 40 672. 40- 45 696. 45- 50 702. 50- 55 685. 55- 60 640. 60- 65 564. 65- 70 474. 70- 75 374. 75- 80 259. 80- 85 166. 85- 90 98. 90- 95 54. 95-100 27. 100-105 16. 105-110 14. 110-115 16. 115-120 20. 120-125 22. 125-130 21. 130-135 18. 135-140 16. 140-145 13. 145-150 11. 150-155 9. 155-160 7. 160-165 5. 165-170 4. 170-175 2. 175-180 1. DATE: 05/24/10 10-DEGREE ZONAL LUMEN 0- 10 0- 20 0- 30 0- 40 0- 50 0- 60 0- 70 0- 80 0- 90 0-100 0-110 0-120 0-130 0-140 0-150 0-160 0-170 0-180 SUMMARY 243. 940. 1999. 3301. 4699. 6024. 7063. 7696. 7960. 8041. 8072. 8108. 8151. 8185. 8208. 8224. 8234. 8237. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64806 WEBSITE: www.itlboulder.com DATE: 05/24/10 PREPARED FOR: SPI LIGHTING, INC. COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 97 88 80 73 66 61 56 52 48 45 42 95 86 77 70 64 59 54 50 47 44 41 90 78 68 59 52 47 42 38 35 32 30 86 74 64 56 50 45 40 37 34 31 29 82 71 61 54 48 43 39 35 32 30 28 80 65 54 45 38 33 28 25 22 20 18 97 84 73 64 56 50 45 41 37 34 31 97 80 67 57 49 42 37 33 30 27 25 97 77 62 51 43 37 32 28 25 22 20 95 82 71 62 55 49 44 40 36 33 31 95 78 66 56 48 42 37 33 29 27 24 95 75 61 50 42 36 32 28 25 22 20 90 75 63 54 46 40 36 32 29 26 24 90 72 59 49 42 36 31 27 24 22 20 86 72 61 52 45 39 35 31 28 26 23 86 70 57 48 41 35 31 27 24 22 20 82 69 58 50 43 38 34 30 27 25 23 82 67 56 47 40 34 30 27 24 21 19 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] REPORT NUMBER: ITL64806 PREPARED FOR: SPI LIGHTING, INC. • WEBSITE: www.itlboulder.com DATE: 05/24/10 ADDENDUM -------SPECIAL TEST PROCEDURES FOR T-5 LAMPS INCLUDING EXPLANATION OF THE IMPORTANCE OF LAMP LUMEN RATINGS. -----------------------------------------------------------------This test was performed using standard relative photometric practices in accordance with recommendations of the Illuminating Engineering Society of North America. Fluorescent testing using the guidelines of relative photometric practice presupposes that the lamps will be operated at their nominal electrical characteristics (e.g., a 40 watt lamp will operate very nearly at 40 watts, and at the voltage and current required for 40-watt operation). Fluorescent lamps in general are temperature sensitive, the lumen output varies with ambient temperature and follows a characteristic curve. The T-5 fluorescent lamps used in this test produce maximum light output in an ambient temperature other than 25 degrees C. A critical step in relative photometric testing involves measurement of the total flux output from the lamp(s) suspended in free air at a 25 degree C ambient temperature per IES LM41-1998. This measurement process is a separate step from the photometric exploration of the luminaire itself. This "bare lamp" measurement is made with the lamp(s) operated by the same ballast(s) which are to be used in the luminaire. Since the test procedure involves measuring the bare lamp flux output at 25 degrees C and this lamp type peaks at a temperature other than 25 degrees C, the flux measured for this lamp type will be less than the maximum output the lamp is designed to produce. As a result, the measurement of the "bare lamp" total flux output is lower than it would be if they were operated at their optimum operating temperature and at nominal electrical characteristics. When this "bare lamp" measurement is incorporated into the luminaire test report, the net effect is that the candela values on the luminaire test report are higher than what the luminaire actually produced and the total luminaire efficiency is higher than what the lighting industry would expect this luminaire to produce. These lighting industry expectations are based on comparisons to the total luminaire efficiency of the same luminaire with T-12 or T-8 lamps. On this particular test, the lamp lumen rating shown is for a 35 degree C ambient temperature. T5TEMP.DIS THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL64813 DATE: 05/25/10 PREPARED FOR: SPI LIGHTING, INC. CATALOG NUMBER: SIP10939-2F54-SS (STANDOFF) LUMINAIRE: EXTRUDED WHITE PAINTED METAL BALLAST HOUSING WITH FABRICATED WHITE PAINTED METAL SOCKET MOUNTING ASSEMBLIES/END CAPS, ONE BLACK PAINTED MACHINED METAL STANDOFF ABOVE EACH SOCKET HOUSING, ONE FORMED WHITE PAINTED METAL REFLECTOR ABOVE EACH LAMP, OPEN BOTTOM. LAMPS: TWO 54-WATT T-5 SYLVANIA FP54/835/HO/ECO LINEAR FLUORESCENTS. BALLAST: ADVANCE ICN-2S54 MOUNTING: SUSPENDED THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL INPUT WATTS = 121.4 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED = 9.17 REPORT IS BASED ON 5000 LUMENS PER LAMP. * CANDELA DISTRIBUTION 0.0 22.5 45.0 0 3046 3046 3046 5 3043 3038 3025 15 2943 2922 2892 25 2746 2703 2707 35 2467 2422 2439 45 2120 2067 2176 55 1709 1633 1874 65 1242 1217 1507 75 714 774 1041 85 103 243 489 90 0 141 313 95 3 8 126 105 9 32 18 115 13 32 54 125 16 30 55 135 14 27 46 145 17 27 39 155 21 24 36 165 29 29 31 175 33 31 31 180 32 32 32 FLUX 67.5 3046 3016 2885 2715 2526 2324 2074 1690 1027 643 462 222 11 45 74 60 49 42 36 32 32 ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 2360 0- 40 3912 0- 60 7291 0- 90 10219 90-120 210 90-130 254 90-150 311 90-180 339 0-180 10559 90.0 3046 3015 2892 2728 2563 2385 2134 1750 1015 698 496 286 9 40 74 65 50 42 36 31 32 %LAMP 23.6 39.1 72.9 102.2 2.1 2.5 3.1 3.4 105.6 TOTAL LUMINAIRE EFFICIENCY = CIE TYPE - DIRECT PLANE : 0-DEG SPACING CRITERIA : 1.3 SHIELDING ANGLES : 1 287 820 1253 1552 1702 1677 1460 974 494 151 21 38 44 34 24 16 9 3 %FIXT 22.3 37.0 69.1 96.8 2.0 2.4 2.9 3.2 100.0 105.6 % * 90-DEG 1.3 0 * SEE ADDENDUM FOR FURTHER INFORMATION 90˚ 75˚ 1050 60˚ 2100 45˚ 3150 0˚ LEGEND: 0-deg: 45-deg: 90-deg: 15˚ Checked M KLOPF Approved R BEATTIE 30˚ THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] REPORT NUMBER: ITL64813 PREPARED FOR: SPI LIGHTING, INC. CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 3046 3046 3046 5.0 3043 3038 3025 10.0 3004 2995 2967 15.0 2943 2922 2892 20.0 2853 2824 2807 25.0 2746 2703 2707 30.0 2612 2567 2580 35.0 2467 2422 2439 40.0 2300 2255 2306 45.0 2120 2067 2176 50.0 1923 1858 2033 55.0 1709 1633 1874 60.0 1484 1421 1708 65.0 1242 1217 1507 70.0 988 991 1283 75.0 714 774 1041 80.0 409 547 604 85.0 103 243 489 90.0 0 141 313 95.0 3 8 126 100.0 6 18 7 105.0 9 32 18 110.0 11 32 37 115.0 13 32 54 120.0 12 30 59 125.0 16 30 55 130.0 15 28 49 135.0 14 27 46 140.0 17 28 43 145.0 17 27 39 150.0 19 25 38 155.0 21 24 36 160.0 25 27 34 165.0 29 29 31 170.0 32 32 34 175.0 33 31 31 180.0 32 32 32 67.5 3046 3016 2950 2885 2810 2715 2611 2526 2434 2324 2204 2074 1891 1690 1488 1027 741 643 462 222 42 11 24 45 62 74 67 60 55 49 46 42 41 36 34 32 32 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA • WEBSITE: www.itlboulder.com DATE: 05/25/10 90.0 3046 3015 2948 2892 2817 2728 2640 2563 2479 2385 2278 2134 1947 1750 1460 1015 806 698 496 286 87 9 18 40 58 74 74 65 59 50 47 42 41 36 32 31 32 THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64813 PREPARED FOR: SPI LIGHTING, INC. WEBSITE: www.itlboulder.com 5-DEGREE ZONAL LUMEN SUMMARY 0- 5 73. 5- 10 215. 10- 15 348. 15- 20 472. 20- 25 580. 25- 30 672. 30- 35 747. 35- 40 805. 40- 45 843. 45- 50 860. 50- 55 853. 55- 60 824. 60- 65 769. 65- 70 691. 70- 75 568. 75- 80 407. 80- 85 291. 85- 90 203. 90- 95 112. 95-100 39. 100-105 10. 105-110 12. 110-115 17. 115-120 21. 120-125 23. 125-130 21. 130-135 19. 135-140 16. 140-145 13. 145-150 11. 150-155 9. 155-160 7. 160-165 6. 165-170 4. 170-175 2. 175-180 1. DATE: 05/25/10 10-DEGREE ZONAL LUMEN SUMMARY 0- 10 287. 0- 20 1107. 0- 30 2360. 0- 40 3912. 0- 50 5614. 0- 60 7291. 0- 70 8751. 0- 80 9725. 0- 90 10219. 0-100 10370. 0-110 10391. 0-120 10429. 0-130 10473. 0-140 10507. 0-150 10531. 0-160 10546. 0-170 10556. 0-180 10559. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64813 WEBSITE: www.itlboulder.com DATE: 05/25/10 PREPARED FOR: SPI LIGHTING, INC. COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 1 2 3 4 5 6 7 8 9 10 125125125125 112106101 96 101 91 83 77 92 79 70 63 83 70 60 52 76 62 52 45 70 56 46 39 65 50 41 34 61 46 36 30 57 42 33 27 53 39 30 24 122122122122 109104 99 94 98 89 82 75 88 77 69 62 81 68 59 52 74 61 51 44 68 54 45 38 63 49 40 34 59 45 36 30 55 41 32 27 51 38 30 24 115115115 98 94 91 85 78 73 74 66 60 65 57 51 58 50 43 52 44 38 47 39 33 43 35 29 40 32 26 37 29 24 110110110 94 90 87 81 75 71 70 64 59 62 55 50 55 48 42 50 43 37 45 38 33 41 34 29 38 31 26 35 28 23 105105105 89 87 84 77 73 69 67 62 57 59 53 48 53 47 42 48 41 36 44 37 32 40 33 29 37 30 26 34 28 23 0 0 102 82 66 55 46 39 34 30 26 24 21 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] REPORT NUMBER: ITL64813 PREPARED FOR: SPI LIGHTING, INC. • WEBSITE: www.itlboulder.com DATE: 05/25/10 ADDENDUM -------SPECIAL TEST PROCEDURES FOR T-5 LAMPS INCLUDING EXPLANATION OF THE IMPORTANCE OF LAMP LUMEN RATINGS. -----------------------------------------------------------------This test was performed using standard relative photometric practices in accordance with recommendations of the Illuminating Engineering Society of North America. Fluorescent testing using the guidelines of relative photometric practice presupposes that the lamps will be operated at their nominal electrical characteristics (e.g., a 40 watt lamp will operate very nearly at 40 watts, and at the voltage and current required for 40-watt operation). Fluorescent lamps in general are temperature sensitive, the lumen output varies with ambient temperature and follows a characteristic curve. The T-5 fluorescent lamps used in this test produce maximum light output in an ambient temperature other than 25 degrees C. A critical step in relative photometric testing involves measurement of the total flux output from the lamp(s) suspended in free air at a 25 degree C ambient temperature per IES LM41-1998. This measurement process is a separate step from the photometric exploration of the luminaire itself. This "bare lamp" measurement is made with the lamp(s) operated by the same ballast(s) which are to be used in the luminaire. Since the test procedure involves measuring the bare lamp flux output at 25 degrees C and this lamp type peaks at a temperature other than 25 degrees C, the flux measured for this lamp type will be less than the maximum output the lamp is designed to produce. As a result, the measurement of the "bare lamp" total flux output is lower than it would be if they were operated at their optimum operating temperature and at nominal electrical characteristics. When this "bare lamp" measurement is incorporated into the luminaire test report, the net effect is that the candela values on the luminaire test report are higher than what the luminaire actually produced and the total luminaire efficiency is higher than what the lighting industry would expect this luminaire to produce. These lighting industry expectations are based on comparisons to the total luminaire efficiency of the same luminaire with T-12 or T-8 lamps. On this particular test, the lamp lumen rating shown is for a 35 degree C ambient temperature. T5TEMP.DIS THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL64807 DATE: 05/24/10 PREPARED FOR: SPI LIGHTING, INC. CATALOG NUMBER: SIP10939-2F54-SPPS (STANDOFF) LUMINAIRE: EXTRUDED WHITE PAINTED METAL BALLAST HOUSING WITH FABRICATED WHITE PAINTED METAL SOCKET MOUNTING ASSEMBLIES/END CAPS, ONE BLACK PAINTED MACHINED METAL STANDOFF ABOVE EACH SOCKET HOUSING, ONE FORMED WHITE PAINTED PERFORATED METAL DIFFUSER ABOVE EACH LAMP, ONE FORMED WHITE PAINTED PERFORATED METAL DIFFUSER BELOW EACH LAMP. LAMPS: TWO 54-WATT T-5 SYLVANIA FP54/835/HO/ECO LINEAR FLUORESCENTS. BALLAST: ADVANCE ICN-2S54 MOUNTING: SUSPENDED THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL INPUT WATTS = 120.0 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED = 9.17 REPORT IS BASED ON 5000 LUMENS PER LAMP. * CANDELA DISTRIBUTION 0.0 22.5 45.0 0 1726 1726 1726 5 1728 1724 1720 15 1663 1663 1668 25 1545 1549 1567 35 1377 1391 1426 45 1171 1187 1267 55 922 947 1078 65 641 689 814 75 340 392 523 85 60 96 207 90 0 43 148 95 11 43 126 105 83 152 277 115 225 282 420 125 379 427 528 135 527 558 631 145 658 677 724 155 761 770 794 165 839 840 847 175 880 877 876 180 878 878 878 FLUX 67.5 1726 1715 1673 1585 1479 1355 1172 902 575 299 242 211 340 535 631 705 771 819 854 875 878 ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 1358 0- 40 2255 0- 60 4187 0- 90 5719 90-120 812 90-130 1284 90-150 2225 90-180 2915 0-180 8634 90.0 1726 1713 1674 1594 1501 1393 1200 933 587 331 268 241 349 570 667 735 791 830 860 875 878 %LAMP 13.6 22.6 41.9 57.2 8.1 12.8 22.3 29.2 86.3 TOTAL LUMINAIRE EFFICIENCY = CIE TYPE - SEMI-DIRECT PLANE : 0-DEG SPACING CRITERIA : 1.3 SHIELDING ANGLES : 90 164 471 723 897 981 952 791 511 229 180˚ 165˚ 150˚ 135˚ 1700 120˚ 850 148 261 403 472 488 453 367 240 83 105˚ 90˚ 75˚ %FIXT 15.7 26.1 48.5 66.2 9.4 14.9 25.8 33.8 100.0 86.3 % * 90-DEG 1.3 90 850 60˚ 1700 0˚ 15˚ LEGEND: 0-deg: 45-deg: 90-deg: 30˚ Checked B HYRE Approved R BEATTIE 45˚ * SEE ADDENDUM FOR FURTHER INFORMATION THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] REPORT NUMBER: ITL64807 PREPARED FOR: SPI LIGHTING, INC. CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 1726 1726 1726 5.0 1728 1724 1720 10.0 1702 1700 1700 15.0 1663 1663 1668 20.0 1610 1613 1623 25.0 1545 1549 1567 30.0 1467 1472 1499 35.0 1377 1391 1426 40.0 1275 1293 1344 45.0 1171 1187 1267 50.0 1051 1071 1176 55.0 922 947 1078 60.0 785 818 963 65.0 641 689 814 70.0 486 557 649 75.0 340 392 523 80.0 195 229 324 85.0 60 96 207 90.0 0 43 148 95.0 11 43 126 100.0 41 98 173 105.0 83 152 277 110.0 146 216 364 115.0 225 282 420 120.0 306 355 479 125.0 379 427 528 130.0 455 495 578 135.0 527 558 631 140.0 596 620 679 145.0 658 677 724 150.0 713 726 760 155.0 761 770 794 160.0 806 811 826 165.0 839 840 847 170.0 866 864 868 175.0 880 877 876 180.0 878 878 878 67.5 1726 1715 1699 1673 1635 1585 1531 1479 1418 1355 1282 1172 1041 902 783 575 390 299 242 211 232 340 456 535 585 631 670 705 739 771 797 819 841 854 868 875 878 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA • WEBSITE: www.itlboulder.com DATE: 05/24/10 90.0 1726 1713 1697 1674 1638 1594 1548 1501 1445 1393 1313 1200 1070 933 800 587 417 331 268 241 243 349 483 570 627 667 703 735 766 791 812 830 848 860 868 875 878 THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64807 PREPARED FOR: SPI LIGHTING, INC. WEBSITE: www.itlboulder.com 5-DEGREE ZONAL LUMEN SUMMARY 0- 5 41. 5- 10 122. 10- 15 200. 15- 20 271. 20- 25 335. 25- 30 389. 30- 35 432. 35- 40 465. 40- 45 486. 45- 50 495. 50- 55 488. 55- 60 464. 60- 65 422. 65- 70 369. 70- 75 300. 75- 80 212. 80- 85 137. 85- 90 92. 90- 95 73. 95-100 76. 100-105 108. 105-110 153. 110-115 189. 115-120 214. 120-125 231. 125-130 241. 130-135 245. 135-140 243. 140-145 234. 145-150 218. 150-155 197. 155-160 170. 160-165 138. 165-170 102. 170-175 62. 175-180 21. DATE: 05/24/10 10-DEGREE ZONAL LUMEN 0- 10 0- 20 0- 30 0- 40 0- 50 0- 60 0- 70 0- 80 0- 90 0-100 0-110 0-120 0-130 0-140 0-150 0-160 0-170 0-180 SUMMARY 164. 635. 1358. 2255. 3236. 4187. 4978. 5490. 5719. 5867. 6128. 6531. 7003. 7491. 7944. 8311. 8551. 8634. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64807 WEBSITE: www.itlboulder.com DATE: 05/24/10 PREPARED FOR: SPI LIGHTING, INC. COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 96 87 78 71 65 59 55 50 47 44 41 90 81 73 67 61 56 51 47 44 41 38 80 69 59 52 46 41 37 33 30 28 25 70 60 52 46 40 36 32 29 27 25 23 61 53 46 40 35 32 29 26 24 22 20 57 46 38 31 26 23 20 17 15 14 12 96 82 71 62 55 49 43 39 36 32 30 96 79 65 55 47 41 36 32 28 26 23 96 75 60 50 42 35 31 27 24 21 19 90 78 67 59 52 46 41 37 34 31 28 90 74 62 52 45 39 34 30 27 24 22 90 71 57 47 40 34 29 26 23 20 18 80 66 55 47 40 35 31 28 25 22 20 80 64 52 43 36 31 27 23 21 19 17 70 58 49 42 36 32 28 25 22 20 18 70 57 46 38 33 28 24 21 19 17 15 61 51 43 37 32 28 25 22 20 18 17 61 50 41 34 29 25 22 19 17 15 14 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] REPORT NUMBER: ITL64807 PREPARED FOR: SPI LIGHTING, INC. • WEBSITE: www.itlboulder.com DATE: 05/24/10 ADDENDUM -------SPECIAL TEST PROCEDURES FOR T-5 LAMPS INCLUDING EXPLANATION OF THE IMPORTANCE OF LAMP LUMEN RATINGS. -----------------------------------------------------------------This test was performed using standard relative photometric practices in accordance with recommendations of the Illuminating Engineering Society of North America. Fluorescent testing using the guidelines of relative photometric practice presupposes that the lamps will be operated at their nominal electrical characteristics (e.g., a 40 watt lamp will operate very nearly at 40 watts, and at the voltage and current required for 40-watt operation). Fluorescent lamps in general are temperature sensitive, the lumen output varies with ambient temperature and follows a characteristic curve. The T-5 fluorescent lamps used in this test produce maximum light output in an ambient temperature other than 25 degrees C. A critical step in relative photometric testing involves measurement of the total flux output from the lamp(s) suspended in free air at a 25 degree C ambient temperature per IES LM41-1998. This measurement process is a separate step from the photometric exploration of the luminaire itself. This "bare lamp" measurement is made with the lamp(s) operated by the same ballast(s) which are to be used in the luminaire. Since the test procedure involves measuring the bare lamp flux output at 25 degrees C and this lamp type peaks at a temperature other than 25 degrees C, the flux measured for this lamp type will be less than the maximum output the lamp is designed to produce. As a result, the measurement of the "bare lamp" total flux output is lower than it would be if they were operated at their optimum operating temperature and at nominal electrical characteristics. When this "bare lamp" measurement is incorporated into the luminaire test report, the net effect is that the candela values on the luminaire test report are higher than what the luminaire actually produced and the total luminaire efficiency is higher than what the lighting industry would expect this luminaire to produce. These lighting industry expectations are based on comparisons to the total luminaire efficiency of the same luminaire with T-12 or T-8 lamps. On this particular test, the lamp lumen rating shown is for a 35 degree C ambient temperature. T5TEMP.DIS THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL64812 DATE: 05/25/10 PREPARED FOR: SPI LIGHTING, INC. CATALOG NUMBER: SIP10939-2F54-SP (STANDOFF) LUMINAIRE: EXTRUDED WHITE PAINTED METAL BALLAST HOUSING WITH FABRICATED WHITE PAINTED METAL SOCKET MOUNTING ASSEMBLIES/END CAPS, ONE BLACK PAINTED MACHINED METAL STANDOFF ABOVE EACH SOCKET HOUSING, ONE FORMED WHITE PAINTED PERFORATED METAL DIFFUSER ABOVE EACH LAMP, OPEN BOTTOM. LAMPS: TWO 54-WATT T-5 SYLVANIA FP54/835/HO/ECO LINEAR FLUORESCENTS. BALLAST: ADVANCE ICN-2S54 MOUNTING: SUSPENDED THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL INPUT WATTS = 123.1 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED = 9.17 REPORT IS BASED ON 5000 LUMENS PER LAMP. * CANDELA DISTRIBUTION 0.0 22.5 45.0 0 2318 2318 2318 5 2313 2313 2305 15 2235 2233 2232 25 2083 2085 2109 35 1871 1885 1941 45 1607 1629 1762 55 1284 1326 1554 65 926 1013 1306 75 521 680 970 85 74 229 446 90 0 115 283 95 5 28 150 105 53 103 211 115 127 171 287 125 207 243 336 135 282 307 376 145 352 369 410 155 409 418 440 165 455 457 463 175 478 476 477 180 477 477 477 FLUX 67.5 2318 2301 2235 2140 2031 1907 1753 1512 972 590 439 272 273 377 427 442 455 463 470 477 477 90.0 2318 2303 2242 2159 2070 1966 1821 1580 973 634 478 339 292 414 460 469 471 471 472 476 477 219 631 976 1226 1367 1383 1256 882 452 188 200 274 298 290 258 203 131 45 180˚ 165˚ 150˚ 135˚ 2200 120˚ 1100 105˚ 90˚ 75˚ ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 1826 0- 40 3052 0- 60 5803 0- 90 8393 90-120 662 90-130 960 90-150 1508 90-180 1888 0-180 10281 %LAMP 18.3 30.5 58.0 83.9 6.6 9.6 15.1 18.9 102.8 TOTAL LUMINAIRE EFFICIENCY = CIE TYPE - SEMI-DIRECT PLANE : 0-DEG SPACING CRITERIA : 1.3 SHIELDING ANGLES : 1 %FIXT 17.8 29.7 56.4 81.6 6.4 9.3 14.7 18.4 100.0 102.8 % * 90-DEG 1.4 0 * SEE ADDENDUM FOR FURTHER INFORMATION 1100 60˚ 2200 0˚ 15˚ LEGEND: 0-deg: 45-deg: 90-deg: 30˚ Checked M KLOPF Approved R BEATTIE 45˚ THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] REPORT NUMBER: ITL64812 PREPARED FOR: SPI LIGHTING, INC. CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 2318 2318 2318 5.0 2313 2313 2305 10.0 2281 2281 2274 15.0 2235 2233 2232 20.0 2167 2167 2175 25.0 2083 2085 2109 30.0 1984 1984 2028 35.0 1871 1885 1941 40.0 1744 1763 1851 45.0 1607 1629 1762 50.0 1456 1480 1659 55.0 1284 1326 1554 60.0 1114 1169 1440 65.0 926 1013 1306 70.0 729 849 1145 75.0 521 680 970 80.0 294 501 573 85.0 74 229 446 90.0 0 115 283 95.0 5 28 150 100.0 27 66 135 105.0 53 103 211 110.0 89 138 251 115.0 127 171 287 120.0 168 207 318 125.0 207 243 336 130.0 246 275 355 135.0 282 307 376 140.0 319 338 393 145.0 352 369 410 150.0 382 396 427 155.0 409 418 440 160.0 436 441 454 165.0 455 457 463 170.0 470 470 474 175.0 478 476 477 180.0 477 477 477 67.5 2318 2301 2271 2235 2191 2140 2082 2031 1973 1907 1836 1753 1640 1512 1381 972 706 590 439 272 196 273 349 377 404 427 434 442 448 455 460 463 468 470 476 477 477 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA • WEBSITE: www.itlboulder.com DATE: 05/25/10 90.0 2318 2303 2275 2242 2205 2159 2114 2070 2020 1966 1902 1821 1703 1580 1374 973 768 634 478 339 228 292 387 414 440 460 468 469 470 471 471 471 473 472 475 476 477 THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64812 PREPARED FOR: SPI LIGHTING, INC. WEBSITE: www.itlboulder.com 5-DEGREE ZONAL LUMEN SUMMARY 0- 5 55. 5- 10 164. 10- 15 268. 15- 20 364. 20- 25 450. 25- 30 525. 30- 35 588. 35- 40 638. 40- 45 673. 45- 50 694. 50- 55 698. 55- 60 685. 60- 65 653. 65- 70 603. 70- 75 510. 75- 80 372. 80- 85 268. 85- 90 184. 90- 95 114. 95-100 74. 100-105 85. 105-110 114. 110-115 132. 115-120 142. 120-125 149. 125-130 150. 130-135 148. 135-140 143. 140-145 134. 145-150 123. 150-155 110. 155-160 94. 160-165 76. 165-170 56. 170-175 34. 175-180 11. DATE: 05/25/10 10-DEGREE ZONAL LUMEN SUMMARY 0- 10 219. 0- 20 851. 0- 30 1826. 0- 40 3052. 0- 50 4420. 0- 60 5803. 0- 70 7059. 0- 80 7941. 0- 90 8393. 0-100 8581. 0-110 8781. 0-120 9055. 0-130 9354. 0-140 9644. 0-150 9901. 0-160 10105. 0-170 10236. 0-180 10281. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64812 WEBSITE: www.itlboulder.com DATE: 05/25/10 PREPARED FOR: SPI LIGHTING, INC. COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 0 1 2 3 4 5 6 7 8 9 10 118118118118 106100 95 90 95 86 78 72 86 74 65 58 78 65 56 49 72 58 48 41 66 52 42 36 61 47 37 31 57 42 33 27 53 39 30 24 49 36 27 22 113113113113 101 96 91 87 90 82 75 69 82 71 63 57 74 63 54 47 68 56 47 40 63 50 41 35 58 45 36 30 54 41 33 27 50 37 29 24 47 34 27 21 104104104 88 84 81 75 70 65 66 59 53 58 50 45 51 44 38 46 38 33 42 34 29 38 31 25 35 28 23 32 25 20 30 50 30 10 10 50 30 10 0 0 95 81 69 60 53 47 42 39 35 32 30 88 74 63 55 49 43 39 36 33 30 28 84 66 53 44 36 31 27 23 21 18 17 95 78 65 55 47 41 36 32 29 26 24 95 75 61 50 42 36 31 27 24 22 20 88 72 60 51 44 38 34 30 27 25 22 88 70 57 47 39 34 29 26 23 21 19 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] REPORT NUMBER: ITL64812 PREPARED FOR: SPI LIGHTING, INC. • WEBSITE: www.itlboulder.com DATE: 05/25/10 ADDENDUM -------SPECIAL TEST PROCEDURES FOR T-5 LAMPS INCLUDING EXPLANATION OF THE IMPORTANCE OF LAMP LUMEN RATINGS. -----------------------------------------------------------------This test was performed using standard relative photometric practices in accordance with recommendations of the Illuminating Engineering Society of North America. Fluorescent testing using the guidelines of relative photometric practice presupposes that the lamps will be operated at their nominal electrical characteristics (e.g., a 40 watt lamp will operate very nearly at 40 watts, and at the voltage and current required for 40-watt operation). Fluorescent lamps in general are temperature sensitive, the lumen output varies with ambient temperature and follows a characteristic curve. The T-5 fluorescent lamps used in this test produce maximum light output in an ambient temperature other than 25 degrees C. A critical step in relative photometric testing involves measurement of the total flux output from the lamp(s) suspended in free air at a 25 degree C ambient temperature per IES LM41-1998. This measurement process is a separate step from the photometric exploration of the luminaire itself. This "bare lamp" measurement is made with the lamp(s) operated by the same ballast(s) which are to be used in the luminaire. Since the test procedure involves measuring the bare lamp flux output at 25 degrees C and this lamp type peaks at a temperature other than 25 degrees C, the flux measured for this lamp type will be less than the maximum output the lamp is designed to produce. As a result, the measurement of the "bare lamp" total flux output is lower than it would be if they were operated at their optimum operating temperature and at nominal electrical characteristics. When this "bare lamp" measurement is incorporated into the luminaire test report, the net effect is that the candela values on the luminaire test report are higher than what the luminaire actually produced and the total luminaire efficiency is higher than what the lighting industry would expect this luminaire to produce. These lighting industry expectations are based on comparisons to the total luminaire efficiency of the same luminaire with T-12 or T-8 lamps. On this particular test, the lamp lumen rating shown is for a 35 degree C ambient temperature. T5TEMP.DIS THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL71375 PAGE: 1 OF 5 ISSUE DATE: 02/14/12 PREPARED FOR: SPI LIGHTING, INC. CATALOG NUMBER: SPI LIGHTING INC OPTICAL #4843 LUMINAIRE: EXTRUDED WHITE PAINTED METAL BALLAST HOUSING WITH FABRICATED WHITE PAINTED METAL SOCKET MOUNTING ASSEMBLIES/END CAPS, ONE FORMED WHITE PAINTED PERFORATED METAL DIFFUSER BELOW EACH LAMP. OPEN TOP. LAMPS: TWO 54-WATT T-5 SYLVANIA FP54/835/HO/ECO LINEAR FLUORESCENTS. BALLAST: AC ELECTRONICS AC-A2/54T5XS MOUNTING: PENDANT TOTAL REFLECTANCE OF PAINT = 93.9 % THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL INPUT WATTS = 115.0 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED = 9.17 REPORT IS BASED ON 5000 LUMENS PER LAMP. * CANDELA DISTRIBUTION 0.0 22.5 45.0 0 413 413 413 5 413 414 414 15 391 396 387 25 352 355 354 35 300 299 308 45 236 238 276 55 164 177 257 65 89 126 236 75 39 85 185 85 6 28 54 90 0 10 35 95 113 105 70 105 567 643 601 115 987 1063 1186 125 1364 1420 1549 135 1689 1727 1824 145 1968 1979 2055 155 2181 2192 2216 165 2327 2327 2332 175 2397 2390 2395 180 2397 2397 2397 FLUX 67.5 413 413 388 361 338 337 347 341 234 87 62 91 556 1203 1656 1925 2117 2260 2336 2395 2397 ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 313 0- 40 513 0- 60 973 0- 90 1431 90-120 1835 90-130 3207 90-150 5902 90-180 7815 0-180 9246 90.0 413 409 385 359 350 367 384 378 217 99 62 95 492 1169 1689 1956 2149 2276 2342 2395 2397 %LAMP 3.1 5.1 9.7 14.3 18.4 32.1 59.0 78.2 92.5 TOTAL LUMINAIRE EFFICIENCY = CIE TYPE - SEMI-INDIRECT PLANE : 0-DEG SHIELDING ANGLES : 1 39 110 164 199 224 236 231 163 64 122 600 1113 1372 1408 1286 1026 660 228 11 1/2 47 3/8 48 3/4 180˚ 0° 165˚ 150˚ 2550 135˚ 1700 120˚ 850 %FIXT 3.4 5.5 10.5 15.5 19.8 34.7 63.8 84.5 100.0 92.5 % * 90-DEG 0 * SEE ADDENDUM FOR FURTHER INFORMATION 105˚ 90˚ LEGEND: 0-deg 45-deg 90-deg Checked S BERGIN Approved R BEATTIE Lighting Engineer THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] REPORT NUMBER: ITL71375 ISSUE DATE: 02/14/12 PREPARED FOR: SPI LIGHTING, INC. CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 413 413 413 5.0 413 414 414 10.0 404 408 407 15.0 391 396 387 20.0 374 378 370 25.0 352 355 354 30.0 327 328 330 35.0 300 299 308 40.0 270 270 290 45.0 236 238 276 50.0 200 207 265 55.0 164 177 257 60.0 124 150 247 65.0 89 126 236 70.0 60 106 219 75.0 39 85 185 80.0 20 64 99 85.0 6 28 54 90.0 0 10 35 95.0 113 105 70 100.0 334 380 257 105.0 567 643 601 110.0 795 866 927 115.0 987 1063 1186 120.0 1191 1242 1385 125.0 1364 1420 1549 130.0 1539 1580 1692 135.0 1689 1727 1824 140.0 1838 1861 1944 145.0 1968 1979 2055 150.0 2083 2094 2145 155.0 2181 2192 2216 160.0 2263 2269 2276 165.0 2327 2327 2332 170.0 2374 2370 2374 175.0 2397 2390 2395 180.0 2397 2397 2397 67.5 413 413 403 388 377 361 344 338 337 337 346 347 351 341 317 234 130 87 62 91 160 556 866 1203 1465 1656 1805 1925 2034 2117 2201 2260 2303 2336 2375 2395 2397 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA • WEBSITE: www.itlboulder.com PAGE: 2 OF 5 90.0 413 409 396 385 374 359 350 350 357 367 378 384 386 378 337 217 130 99 62 95 147 492 829 1169 1473 1689 1836 1956 2056 2149 2218 2276 2315 2342 2376 2395 2397 THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL71375 ISSUE DATE: 02/14/12 PREPARED FOR: SPI LIGHTING, INC. 5-DEGREE ZONAL LUMEN SUMMARY 0- 5 10. 5- 10 29. 10- 15 47. 15- 20 63. 20- 25 77. 25- 30 87. 30- 35 96. 35- 40 103. 40- 45 109. 45- 50 114. 50- 55 117. 55- 60 119. 60- 65 118. 65- 70 113. 70- 75 97. 75- 80 66. 80- 85 39. 85- 90 25. 90- 95 31. 95-100 92. 100-105 223. 105-110 377. 110-115 506. 115-120 607. 120-125 670. 125-130 702. 130-135 710. 135-140 698. 140-145 668. 145-150 619. 150-155 553. 155-160 473. 160-165 380. 165-170 279. 170-175 171. 175-180 57. WEBSITE: www.itlboulder.com PAGE: 3 OF 5 10-DEGREE ZONAL LUMEN 0- 10 0- 20 0- 30 0- 40 0- 50 0- 60 0- 70 0- 80 0- 90 0-100 0-110 0-120 0-130 0-140 0-150 0-160 0-170 0-180 SUMMARY 39. 149. 313. 513. 736. 973. 1204. 1367. 1431. 1553. 2153. 3266. 4638. 6046. 7333. 8359. 9018. 9246. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL71375 PAGE: 4 OF 5 ISSUE DATE: 02/14/12 PREPARED FOR: SPI LIGHTING, INC. COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 0 1 2 3 4 5 6 7 8 9 10 91 83 75 68 62 57 52 48 44 41 38 80 73 66 60 54 50 46 42 39 36 34 59 51 45 39 34 31 27 25 22 20 18 40 35 30 26 23 21 18 17 15 14 13 23 19 17 15 13 11 10 9 8 8 7 14 11 9 7 6 5 5 4 3 3 3 91 79 69 60 53 47 42 37 34 30 28 91 75 63 53 46 40 34 30 27 24 21 91 72 58 48 40 34 29 25 22 19 17 80 69 60 53 46 41 37 33 30 27 25 80 66 56 47 41 35 31 27 24 21 19 80 64 52 43 36 30 26 23 20 17 15 59 49 42 35 30 26 23 20 18 16 15 59 48 39 32 27 23 20 17 15 13 12 40 34 28 24 21 18 16 14 12 11 10 40 33 27 22 19 16 14 12 11 9 8 23 19 16 13 12 10 9 8 7 6 6 23 18 15 12 10 9 8 7 6 5 5 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] REPORT NUMBER: ITL71375 ISSUE DATE: 02/14/12 PREPARED FOR: SPI LIGHTING, INC. • WEBSITE: www.itlboulder.com PAGE: 5 OF 5 ADDENDUM -------SPECIAL TEST PROCEDURES FOR T-5 LAMPS INCLUDING EXPLANATION OF THE IMPORTANCE OF LAMP LUMEN RATINGS. -----------------------------------------------------------------This test was performed using standard relative photometric practices in accordance with recommendations of the Illuminating Engineering Society of North America. Fluorescent testing using the guidelines of relative photometric practice presupposes that the lamps will be operated at their nominal electrical characteristics (e.g., a 40 watt lamp will operate very nearly at 40 watts, and at the voltage and current required for 40-watt operation). Fluorescent lamps in general are temperature sensitive, the lumen output varies with ambient temperature and follows a characteristic curve. The T-5 fluorescent lamps used in this test produce maximum light output in an ambient temperature other than 25 degrees C. A critical step in relative photometric testing involves measurement of the total flux output from the lamp(s) suspended in free air at a 25 degree C ambient temperature per IES LM41-1998. This measurement process is a separate step from the photometric exploration of the luminaire itself. This "bare lamp" measurement is made with the lamp(s) operated by the same ballast(s) which are to be used in the luminaire. Since the test procedure involves measuring the bare lamp flux output at 25 degrees C and this lamp type peaks at a temperature other than 25 degrees C, the flux measured for this lamp type will be less than the maximum output the lamp is designed to produce. As a result, the measurement of the "bare lamp" total flux output is lower than it would be if they were operated at their optimum operating temperature and at nominal electrical characteristics. When this "bare lamp" measurement is incorporated into the luminaire test report, the net effect is that the candela values on the luminaire test report are higher than what the luminaire actually produced and the total luminaire efficiency is higher than what the lighting industry would expect this luminaire to produce. These lighting industry expectations are based on comparisons to the total luminaire efficiency of the same luminaire with T-12 or T-8 lamps. On this particular test, the lamp lumen rating shown is for a 35 degree C ambient temperature. T5TEMP.DIS THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] • WEBSITE: www.itlboulder.com REPORT NUMBER: ITL64271 DATE: 03/03/10 PREPARED FOR: SPI LIGHTING, INC. CATALOG NUMBER: SIP10939-2F54-BLADE LOUVER (WHITE) LUMINAIRE: EXTRUDED WHITE PAINTED METAL BALLAST HOUSING WITH FABRICATED WHITE PAINTED METAL SOCKET MOUNTING ASSEMBLIES/END CAPS, ONE FORMED WHITE PAINTED 60-CELL METAL LOUVER BELOW EACH LAMP, OPEN TOP. LAMPS: TWO 54-WATT T-5 SYLVANIA FP54/835/HO/ECO LINEAR FLUORESCENTS. BALLAST: ADVANCE ICN-2S54 MOUNTING: SUSPENDED THE 0 DEGREE PLANE IS PARALLEL WITH THE LAMPS. TOTAL INPUT WATTS = 123.2 AT 120.0 VOLTS LUMEN TO CANDELA RATIO USED = 9.17 REPORT IS BASED ON 5000 LUMENS PER LAMP. * CANDELA DISTRIBUTION 0.0 22.5 45.0 0 1258 1258 1258 5 1233 1241 1255 15 1097 1137 1209 25 911 985 1132 35 699 821 1044 45 482 640 946 55 281 466 857 65 193 327 771 75 106 270 553 85 23 106 175 90 0 52 111 95 65 190 177 105 306 579 700 115 554 767 1088 125 764 932 1206 135 946 1065 1265 145 1095 1176 1303 155 1205 1251 1321 165 1278 1293 1321 175 1303 1302 1305 180 1302 1302 1302 ZONAL LUMEN SUMMARY ZONE LUMENS 0- 30 985 0- 40 1643 0- 60 3130 0- 90 4422 90-120 1792 90-130 2836 90-150 4612 90-180 5717 0-180 10139 FLUX 67.5 1258 1267 1279 1283 1285 1263 1218 1013 624 183 130 187 715 1151 1415 1437 1417 1377 1343 1306 1302 90.0 1258 1272 1309 1358 1404 1418 1363 1064 552 142 95 143 679 1153 1470 1497 1455 1400 1354 1309 1302 119 341 524 658 734 753 676 458 159 192 649 951 1044 965 811 608 373 125 180˚ 165˚ 150˚ 135˚ 1300 120˚ 650 105˚ 90˚ 75˚ %LAMP 9.8 16.4 31.3 44.2 17.9 28.4 46.1 57.2 101.4 TOTAL LUMINAIRE EFFICIENCY = %FIXT 9.7 16.2 30.9 43.6 17.7 28.0 45.5 56.4 100.0 101.4 % * CIE TYPE - DIRECT-INDIRECT PLANE : 0-DEG 90-DEG SPACING CRITERIA : 1.0 1.7 SHIELDING ANGLES : 34 0 650 60˚ 1300 0˚ 15˚ LEGEND: 0-deg: 45-deg: 90-deg: 30˚ Checked R HUMPHREYS Approved R BERGIN 45˚ * SEE ADDENDUM FOR FURTHER INFORMATION THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • E-MAIL: [email protected] REPORT NUMBER: ITL64271 PREPARED FOR: SPI LIGHTING, INC. CANDELA DISTRIBUTION 0.0 22.5 45.0 0.0 1258 1258 1258 5.0 1233 1241 1255 10.0 1175 1199 1239 15.0 1097 1137 1209 20.0 1007 1064 1172 25.0 911 985 1132 30.0 807 904 1088 35.0 699 821 1044 40.0 590 732 995 45.0 482 640 946 50.0 373 549 898 55.0 281 466 857 60.0 237 382 825 65.0 193 327 771 70.0 148 291 672 75.0 106 270 553 80.0 62 215 329 85.0 23 106 175 90.0 0 52 111 95.0 65 190 177 100.0 177 416 450 105.0 306 579 700 110.0 438 680 919 115.0 554 767 1088 120.0 668 853 1164 125.0 764 932 1206 130.0 859 1004 1237 135.0 946 1065 1265 140.0 1024 1125 1286 145.0 1095 1176 1303 150.0 1157 1219 1315 155.0 1205 1251 1321 160.0 1248 1277 1324 165.0 1278 1293 1321 170.0 1295 1300 1314 175.0 1303 1302 1305 180.0 1302 1302 1302 67.5 1258 1267 1276 1279 1282 1283 1285 1285 1278 1263 1248 1218 1139 1013 846 624 314 183 130 187 373 715 940 1151 1333 1415 1438 1437 1430 1417 1399 1377 1362 1343 1323 1306 1302 INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA 90.0 1258 1272 1291 1309 1333 1358 1382 1404 1415 1418 1412 1363 1246 1064 855 552 243 142 95 143 295 679 928 1153 1352 1470 1501 1497 1477 1455 1427 1400 1378 1354 1329 1309 1302 • WEBSITE: www.itlboulder.com DATE: 03/03/10 ZONAL LUMEN SUMMARY 0- 5 30. 5- 10 89. 10- 15 145. 15- 20 196. 20- 25 242. 25- 30 282. 30- 35 315. 35- 40 343. 40- 45 361. 45- 50 373. 50- 55 378. 55- 60 375. 60- 65 356. 65- 70 320. 70- 75 273. 75- 80 185. 80- 85 104. 85- 90 54. 90- 95 58. 95-100 134. 100-105 274. 105-110 376. 110-115 450. 115-120 501. 120-125 525. 125-130 519. 130-135 498. 135-140 467. 140-145 428. 145-150 383. 150-155 332. 155-160 276. 160-165 217. 165-170 156. 170-175 94. 175-180 31. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] • REPORT NUMBER: ITL64271 WEBSITE: www.itlboulder.com DATE: 03/03/10 PREPARED FOR: SPI LIGHTING, INC. COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC RW 80 70 50 30 10 0 1 2 3 4 5 6 7 8 9 10 107107107107 97 92 88 84 88 80 73 68 79 69 62 55 72 61 53 46 66 54 46 39 61 48 40 34 56 43 35 29 52 39 31 26 48 36 28 23 45 33 25 20 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 98 88 80 72 66 60 55 51 47 44 41 81 70 60 52 46 41 37 33 30 27 25 65 56 48 42 37 33 30 27 25 22 21 51 44 38 33 29 26 23 21 19 18 16 44 35 29 23 20 17 14 13 11 10 9 98 84 73 64 56 50 44 40 36 33 30 98 81 67 57 49 42 37 32 29 26 23 98 77 62 51 43 36 31 27 24 21 19 81 67 56 47 41 35 31 27 24 22 20 81 65 52 43 36 31 27 23 20 18 16 65 54 45 39 33 29 25 23 20 18 17 65 53 43 35 30 25 22 19 17 15 14 51 42 36 30 26 23 20 18 16 15 13 51 41 34 28 24 20 18 15 14 12 11 ALL CANDELA, LUMENS, LUMINANCE, COEFFICIENT OF UTILIZATION AND VCP VALUES IN THIS REPORT ARE BASED ON RELATIVE PHOTOMETRY WHICH ASSUMES A BALLAST FACTOR OF 1.000. ANY CALCULATIONS PREPARED FROM THESE DATA SHOULD INCLUDE AN APPROPRIATE BALLAST FACTOR. THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE. THE LIGHT CENTER OF THE INDUSTRY SINCE 1955 PHONE: (303)442-1255 • FAX: (303)449-5274 • INDEPENDENT TESTING LABORATORIES, INC. 3386 LONGHORN ROAD, BOULDER, CO 80302 USA E-MAIL: [email protected] REPORT NUMBER: ITL64271 PREPARED FOR: SPI LIGHTING, INC. • WEBSITE: www.itlboulder.com DATE: 03/03/10 ADDENDUM -------SPECIAL TEST PROCEDURES FOR T-5 LAMPS INCLUDING EXPLANATION OF THE IMPORTANCE OF LAMP LUMEN RATINGS. -----------------------------------------------------------------This test was performed using standard relative photometric practices in accordance with recommendations of the Illuminating Engineering Society of North America. Fluorescent testing using the guidelines of relative photometric practice presupposes that the lamps will be operated at their nominal electrical characteristics (e.g., a 40 watt lamp will operate very nearly at 40 watts, and at the voltage and current required for 40-watt operation). Fluorescent lamps in general are temperature sensitive, the lumen output varies with ambient temperature and follows a characteristic curve. The T-5 fluorescent lamps used in this test produce maximum light output in an ambient temperature other than 25 degrees C. A critical step in relative photometric testing involves measurement of the total flux output from the lamp(s) suspended in free air at a 25 degree C ambient temperature per IES LM41-1998. This measurement process is a separate step from the photometric exploration of the luminaire itself. This "bare lamp" measurement is made with the lamp(s) operated by the same ballast(s) which are to be used in the luminaire. Since the test procedure involves measuring the bare lamp flux output at 25 degrees C and this lamp type peaks at a temperature other than 25 degrees C, the flux measured for this lamp type will be less than the maximum output the lamp is designed to produce. As a result, the measurement of the "bare lamp" total flux output is lower than it would be if they were operated at their optimum operating temperature and at nominal electrical characteristics. When this "bare lamp" measurement is incorporated into the luminaire test report, the net effect is that the candela values on the luminaire test report are higher than what the luminaire actually produced and the total luminaire efficiency is higher than what the lighting industry would expect this luminaire to produce. These lighting industry expectations are based on comparisons to the total luminaire efficiency of the same luminaire with T-12 or T-8 lamps. On this particular test, the lamp lumen rating shown is for a 35 degree C ambient temperature. T5TEMP.DIS THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES. FIELD PERFORMANCE MAY DIFFER FROM LABORATORY PERFORMANCE.
© Copyright 2025 Paperzz