UPDATED RANGE GreenScreen® Revive™ & Vela Met 100% PVC-free polyester fabrics Produced from recycled plastic bottles, GreenScreen® Revive™ is a 100% recyclable, PVC-free polyester fabric that is free of heavy metals, low in VOC and made from 89% recycled content. Vela Met is a high-performing, environmentally-friendly, warp-knit sunscreen fabric with metalised backing that helps to save energy through the maximum reflection of solar energy. Thermal & Optical Properties Solar protection and light control indicators are laboratory-tested. The most relevant and widely used factors include: Optical Factors Thermal Factors (Fabric and Glass) Tv Visible Transmittance This factor measures the percentage of visible light coming through the fabric that can be seen by the naked eye. It is related to the amount of light (brightness) a person receives through a glazing system. A low figure shows a very efficient fabric. G-value The g-value is a measure of the total solar energy transmittance calculated using either EN 13363-1A1 (2007) or ASTM E903-96 standards. A low number means better performance against solar heat build-up. Rv Visible Light Reflectance This factor measures the percentage of visible light reflected by the fabric to the outside of a building. The higher the number the more visible light reflected. Tuv Ultra Violet Transmittance This factor measures the value of ultra violet light going through the fabric. The lower the value, the less ultra violet light transmitted through the fabric. Of Openness Factor This factor measures the proportion of holes in a woven fabric. This parameter, together with other technical properties of the fabric, should be considered when determining the degree of visibility and heat and glare control that the fabric offers. The openness factor can vary slightly from colour to colour in the same fabric, and is often expressed as an Average OF. A low OF indicates that the fabric has a very close weave. Thermal Factors (Fabric only) Ts Solar Transmittance This factor measures the proportion of solar energy transmitted through the fabric. A low percentage means the fabric performs well at reducing solar energy. Rs Solar Reflectance This factor measures the proportion of solar radiation reflected by the fabric. A high percentage means the fabric performs well at reflecting solar energy. As Solar Absorptance This factor measures the proportion of solar radiation absorbed by the fabric. A low percentage means the fabric absorbs little solar energy. Solar radiation is always partially transmitted through, absorbed or reflected by the fabric. The sum of all 3 equals 100. Ts + Rs + As = 100 % of solar energy. Solar Heat Gain Coefficient The Solar Heat Gain Coefficient (SHGC) measures the window’s (fabric and glass) ability to transmit solar energy into a room. The SHGC is commonly referred to as g-tot. SHGC/g-tot is a calculation of the solar protection device (fabric) and the glazing (CL-S/DG). The lower the g-tot value, the greater its ability to insulate against solar heat build-up. Glazing Types Test data has been supplied using the following glazing types: • CL-S (EN14501 glazing type A) Clear single glazing (4mm float) With a g-value of 0.85 • DG (EN14501 glazing type C) Double glazing (4mm float + 16mm space + 4mm float) with low emissivity coating in position 3 (outer surface of the inner plane), space filled with argon. With a g-value of 0.59 Revive 1% SHGC/G Value g-tot (glass & blind) As DG Tv Roll Width 300cm 66 6 0.28 27 X 61 13 0.29 23 X 25 58 17 0.30 20 X Suede 19 39 42 0.32 7 X 2501.3000.0022 Stone 24 52 24 0.30 17 X 2501.3000.0001 Pewter 19 43 38 0.32 8 X 2501.3000.0030 Onyx 17 34 49 0.33 5 X Colour Code Colour Name Ts Rs 2501.3000.0002 White 28 2501.3000.0010 Sand 26 2501.3000.0020 Linen 2501.3000.0071 Fenestration Properties The GreenScreen Revive fabric fenestration property tests were conducted in accordance with EN 14501:2005, ASTM E891, ASTM E903-96: Solar Heat Gain Coefficient SHGC (G-Value), Solar Transmittance (Ts), Solar Reflectance (Rs), Solar Absorptance (As), Visible Light Transmission VLT (Tv), Double Glazing 6mm/½" air/6mm with low E on surface #2. Glass performance tests were conducted using the Lawrence Berkeley National Laboratory Window 6.3 NFRC certified software. Revive 1% Vela Met SHGC/G Value g-tot (glass & blind) Colour Code Colour Name 2105.2400.M007 Pearl 2105.2400.M023 Pewter Pewter metalised side 2105.2400.M015 Charcoal/Bronze Charcoal/Bronze metalised side 2105.2400.M030 Charcoal Charcoal metalised side Ts Rs As CL-S DG Tv Rv 12 44 45 0.44 0.42 12 47 7 X 12 46 42 0.43 0.41 12 46 7 X 9 29 62 0.59 0.47 6 11 4 X 8 42 50 0.48 0.43 4 40 4 X 9 24 68 0.54 0.48 5 7 5 X 8 42 50 0.44 0.43 5 40 5 X 11 23 66 0.55 0.48 3 4 5 X 10 40 50 0.46 0.43 4 36 5 X Fenestration Properties The Vela Met fabric fenestration property tests were conducted in accordance with EN 410:1998, EN 14500:2008, EN 14501:2005, EN 13363-1A1 (2007) g-value, Solar Heat Gain Coefficient (SHGC), Solar Transmittance (Ts), Solar Reflectance (Rs), Solar Absorptance (As), Visible Light Transmittance (Tv), Visible Light Reflectance (Rv), Ultra Violet Transmittance (Tuv); 4mm Clear Glass, Single Glazing (CL-S); Double Glazing 4mm/16mm/4mm with low E-coating in position 3, space filled with Argon (DG); To calculate shading coefficient: SHGC CL-S / 0.87. The data supplied here is indicative. For up-to-date test results, performance specifications, or larger samples, contact Mermet at mermet.com.au. Care and Cleaning Brushing softly and lightly with a clean, soft bristled brush will remove any loose dirt or dust. You can also use a vacuum with a soft brush. When vacuuming, avoid pulling or stretching the fabric. Vela Met GreenScreen® 100% PVC-free polyester Pearl metalised side Roll Width Tuv 240cm GreenScreen® Revive™ & Vela Met Technical data GreenScreen® Revive™ Composition GreenScreen® 100% PVC-free polyester Fire Classification Vela Met 100% polyester (89% recycled content) 100% polyester with metalised backing USA NFPA 701-10 TM#1, California U.S. Title 19. CAN/ULC-S109-03 Small Flame Test. AUS AS/NZS 1530.3 – 1999 AS 1530.2 – 1993¹ NFPA 701-99 Small Scale AS/NZS 1530.3 – 1999 AS 1530.2 – 1993¹ Openness Factor Average 1% Average 2% Widths 300cm 240cm Pattern Warp knit Warp knit Weight per M² 199g ± 5% 179g ± 5% Thickness 0.49mm ± 5% 0.38mm ± 5% Breaking Strength Warp – Weft – >104 daN/5cm >40.8 daN/5cm Tear Resistance Warp – Weft – 5.24 daN 5.9 daN Colour Fastness to Light – 7/8 Cutting* Cold, ultrasonic or crush cut Ultrasonic or crush cut ISO 105 B02: 1994 (Scale of 8) Applications Accreditations GreenScreen Revive ¹ FR tested to 1530.2 and 1530.3. Suitable for Class 2-9(a) and (c) buildings. * We recommend testing all cutting and welding methods prior to use, to confirm they meet your individual fabrication specifications. Note Data supplied in this document is for information purposes only and may not be considered as binding. Warranty conditions apply; refer to mermet.com.au for more details. mermet.com.au
© Copyright 2026 Paperzz