CABLE SELECTION CHART Submersible Pumpset Cable Selection Chart For 220V-Single Phase-50hz LENGTH IN METRES FR PVC Insulated Multicore Cables Co-Axial TV Cables HP 10 20 30 40 50 60 70 80 90 100 120 140 160 180 200 250 300 0.5 1 1.5 2 3 4 5 1.5 1.5 1.5 1.5 1.5 1.5 2.5 1.5 1.5 1.5 1.5 1.5 2.5 2.5 1.5 1.5 1.5 2.5 2.5 2.5 4 1.5 1.5 2.5 2.5 2.5 4 4 1.5 1.5 2.5 4 4 4 6 1.5 1.5 2.5 4 4 6 6 1.5 2.5 4 4 6 6 10 1.5 2.5 4 6 6 10 10 1.5 2.5 4 6 6 10 10 1.5 2.5 6 6 10 10 10 2.5 4 6 10 10 10 16 2.5 4 10 10 10 16 16 2.5 4 10 10 16 16 16 4 6 10 16 16 16 25 4 6 10 16 16 16 25 4 6 16 16 16 25 25 6 10 16 25 25 35 50 Note : 1. HP 7.5D and above are STAR/DELTA motors. Indoor Telephone Cables Three Core Flat Cables 2. For STAR DELTA Starting reduce current by 1/┛3 for selecting suitable cable. Conversion Table: 1 m = 3.28 ft. 1 ft = 0.3.5 m EON ELECTRIC LTD. (Formerly Indo Asian Fusegear Limited) B-88, Sector-83, Noida-201305, Uttar Pradesh, India P: +91-120-3096780 E: [email protected] Customer care: 1800 11 0808 www.eonelectric.com EEL|FC|5K|051112 Single Phase : For other Voltages the cable size is to be selected as follows :Calculated length = 220÷Volt) x actual length Example: For a 3 HP 460 volts motor and 100 metres actual cable length, calculated length = (220÷460) x 100=48m. the size of the cable to be selected 48m from the chart is 4mm2. Three Phase : For other Voltages the cable size is to selected as follows :Calculated length=(415÷Volt) x actual length. Example : For a 20 HP motor at 350 volts and 90 metres actual cable length, calculated length=(415÷350) x 90 = 170m. The size of the cable to be selected for 107m from the chart is 6mm2. EON Flat Cables, Stand the test of time. When it comes to quality Flat Cables, it’s hard to match EON. Made using the latest technology and tested under extreme conditions, these wires can be used in both fresh and salt water. No wonder, they are perfect for agriculture and multiple underground usage. CABLE SELECTION CHART Submersible Pumpset Cable Selection Chart For 415V-Three Phase - 50hz LENGTH IN METRES Three Core Flat PVC Insulated Flexible Industrial Cable for Submersible use, 1100 Voltage Grade Nominal Insulation Area of * Number/Size Thickness Coductor of Wire for (Nom.) Each Core sq. mm sq. mm 1.50 2.50 4.00 6.00 10.00 16.00 30/0.25 50/0.25 56/0.3 84/0.3 80/0.4 126/0.4 mm 0.6 0.7 0.8 0.8 1.0 1.0 Sheath Approx Overall Dimensions Core dia Aprox. (Nom.) mm 2.9 3.6 4.1 4.7 6.10 7.4 Width W (Nom.) mm 10.4 12.8 15.0 16.8 21.0 24.3 Thickness T (Nom.) mm 4.8 5.7 6.5 7.2 8.8 10.0 Max Conductor Resistance at Current Carrying Capacity at 400 C (Max.) ohm/km 13.3 7.89 4.95 3.30 1.91 1.21 amps 14 18 26 31 42 57 Note: Conductor as per class V. Available in 500±5% meters packing on drums. Also available in 100 meters packing on request. *The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria. ** Conductor for all size shall be of class V. T Color Coating (Red, Yellow, Blue) Flexible Copper Conductor PVC insulation of Cores PVC Sheath (Black) W HP 10 20 30 40 50 60 70 80 90 100 120 140 160 180 200 250 300 350 400 3 4 5 6 7.5S 7.5D 10 12.5 15 17.5 20 25 30 40 50 1.5 1.5 1.5 1.5 2.5 1.5 1.5 2.5 2.5 4 4 4 6 10 16 1.5 1.5 1.5 1.5 2.5 1.5 1.5 2.5 2.5 4 4 4 6 10 16 1.5 1.5 1.5 1.5 2.5 1.5 1.5 2.5 2.5 4 4 4 6 10 16 1.5 1.5 1.5 1.5 2.5 1.5 1.5 2.5 2.5 4 4 4 6 10 16 1.5 1.5 1.5 1.5 2.5 1.5 1.5 2.5 2.5 4 4 4 6 10 16 1.5 1.5 1.5 1.5 2.5 1.5 1.5 2.5 2.5 4 4 4 6 10 16 1.5 1.5 1.5 2.5 2.5 1.5 2.5 2.5 2.5 4 4 4 6 10 16 1.5 1.5 1.5 2.5 2.5 1.5 2.5 2.5 4 4 4 4 6 10 16 1.5 1.5 2.5 2.5 4 1.5 2.5 4 4 4 4 4 6 10 16 1.5 1.5 2.5 2.5 4 1.5 2.5 4 4 4 4 4 6 10 16 1.5 1.5 2.5 2.5 4 1.5 2.5 4 4 4 4 4 6 10 16 2.5 2.5 2.5 4 4 2.5 4 4 6 6 10 10 10 16 16 2.5 2.5 2.5 4 4 2.5 4 4 6 6 10 10 10 16 16 2.5 4 4 4 6 4 4 6 6 10 10 10 10 16 25 2.5 4 4 6 6 4 6 6 10 10 10 16 16 25 25 4 4 6 6 10 4 6 10 10 10 16 16 16 25 35 4 6 6 10 10 6 10 10 10 16 16 16 25 25 35 4 6 6 10 10 6 10 10 10 16 16 25 25 35 50 6 6 10 10 16 10 10 16 16 16 25 25 25 35 50
© Copyright 2026 Paperzz