9360do series - Gotham Lighting

9360DO SERIES
CATALOG
NUMBER
Monochromatic LED
Drive-Over Flush Mounted
Up-Light
NOTES
TYPE
DESCRIPTION
Hydrel’s Model 9360DO, is a bronze well light,
incorporating some of the internal components of
our M9400 Series. This fixture features drive over
capacities, capable of supporting a wide variety
of vehicle types and loads. The Soils Engineer or
Pavement Designer must properly design this fixture
into the supporting soil, subbase, and finishing
surface. A properly designed pavement section
could support the fixture for vertical and lateral loads
up through AASHTO HS20 (20-ton truck-16000 Ibs.
per wheel load @ 15 miles per hour). The smaller
fixture footprint allows for placement in tight areas.
Specifications
L:
8 - 5/16”
211 mm
11”
279 mm
16 - 1/4”
413 mm
W:
H:
16 1/4"
16 1/4"
EXAMPLE: 9360DO B DN 12LED BLU MVOLT NSP FLC 34B LP
ORDERING INFORMATION
Model*
Material*
Position*
Lamp Type*
LED Color*
9360DO Drive Over
B
UP
Flange Up
12LED
WHT30K
White
DN
Flange Down
WHT41K
White
WHT53K
White
AMBPC
Phosphor Converted Amber
BLU
Blue
GRN
Green
RED
Red
Bronze
Distribution*
Lens*
NSP
Narrow Spot
FLC
MFL
Medium Flood
FL
Flood
WFL
Wide Flood
Flat Lens Clear
Voltage*
Conduit Entry*
Lamp*
34B
3/4” NPT bottom
LP
25S1
Two 25mm side
MVOLT (120 - 277V)
Listing
Lamp Installed
IEC1
International
Electrotechnical
Commission
VWFL Very Wide Flood (no optics)
HSP
Horizontal Spot
HFL
Horizontal Flood
*Required Entries
Notes:
1 Only for use in 50HZ applications.
9360 Series Assembly RISFD or RISFU
consists of the following MACS Lamp Module
individual components
parts MHSL94 Power Module
9144 Deering Ave. Second Floor • Chatsworth, CA 91311
Phone: 866.533.9901 • www.hydrel.com
©2014-2017 Acuity Brands Lighting, Inc.
03/21/17
9360_DO_LED
PERFORMANCE DATA
LUMEN OUTPUT
Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Actual performance
may differ as a result of end-user environment and application. Contact factory for performance data on any configurations not shown here.
3000K
80CRI
4000K
70CRI
5000K
70CRI
Distribution
Nema
Type
Beam Angle (50%)
HxV
Field Angle (10%)
HxV
Watts
LPW
Delivered
Lumens
NSP
2x2
14.7 x 14.7
28 x 28
14
50
700
MFL
3x3
24.4 x 24.4
44 x 44
14
50
700
FL
6x6
74.5 x 70.8
104.2 x 102.1
14
36
500
WFL
6x6
102.5 x 100.4
129.6 x 129.1
14
43
600
HSP
3x3
21.6 x 21.6
39.9 x 39.9
14
50
700
600
HFL
4x3
39.3 x 15.7
59.6 x 29.9
14
43
VWFL
6x6
89.3 x 85.1
129.4 x 128.2
13
31
400
NSP
2x2
14.7 x 14.7
28 x 28
14
86
1,200
MFL
3x3
24.4 x 24.4
44 x 44
14
86
1,200
FL
6x6
74.5 x 70.8
104.2 x 102.1
14
64
900
WFL
6x6
102.5 x 100.4
129.6 x 129.1
14
79
1,100
HSP
3x3
21.6 x 21.6
39.9 x 39.9
14
86
1,200
HFL
4x3
39.3 x 15.7
59.6 x 29.9
14
79
1,100
VWFL
6x6
89.3 x 85.1
129.4 x 128.2
13
54
700
NSP
2x2
14.7 x 14.7
28 x 28
14
86
1,200
MFL
3x3
24.4 x 24.4
44 x 44
14
86
1,200
FL
6x6
74.5 x 70.8
104.2 x 102.1
14
64
900
WFL
6x6
102.5 x 100.4
129.6 x 129.1
14
79
1,100
HSP
3x3
21.6 x 21.6
39.9 x 39.9
14
86
1,200
HFL
4x3
39.3 x 15.7
59.6 x 29.9
14
79
1,100
VWFL
6x6
89.3 x 85.1
129.4 x 128.2
13
54
700
LED LIFE: L70/60,000 hours
OPERATING TEMPERATURE: -30°C Through 40°C
Lumen Ambient Temperature (LAT) Multipliers
Use these factors to determine relative lumen output for average ambient temperatures
from 0-40°C (32-104°F).
Ambient
0°C
10°C
20°C
25°C
30°C
40°C
Lumen Multiplier
32°F
50°F
68°F
77°F
86°F
104°F
1.02
1.01
1.00
1.00
0.99
0.98
Projected LED Lumen Maintenance
Data references the extrapolated performance projections for the Fixture platform in
a 25°C ambient, based on 8400 hours of LED testing (tested per IESNA LM-80-08 and
projected per IESNA TM-21-11).
To calculate LLF, use the lumen maintenance factor that corresponds to the desired number
of operating hours below. For other lumen maintenance values, contact factory.
Operating Hours
0
25,000
50,000
100,000
Lumen Maintenance
Factor
1
0.99
0.98
0.96
Electrical Load
Current (A)
Light Drive Current
Engines
(mA)
12 LED
350mA
System
Watts
14
120
208
240
277
347
480
0.117 0.067 0.058 0.051 0.040 0.029
Load Rating
A properly designed pavement section could support the fixture for vertical
and lateral loads up through AASHTO HS20 (20-ton truck-16000 Ibs. per
wheel load @ 15 miles per hour).
FEATURES & SPECIFICATIONS
ROUGH IN SECTION CONSTRUCTION: Cast bronze frame with stainless steel well. Specify
flange up or flange down design with order.
LAMP MODULE HOUSING: Stainless steel, sealed and purged of all moisture to -100°F.
Electrical access to lamp module is done through submersible rated connector.
POWER MODULE: LED driver is encapsulated in a custom designed heat-dissipating epoxy resin
that also eliminates all moisture intrusion. Module is provided with submersible rated cord leads
for connection to integral junction box and lamp module.
LAMP TYPES: LED: Monochromatic LEDs, 12W. LAMP INCLUDED.
VOLTAGE: MVOLT (120 - 277) Volts, 50 - 60 Hz.
LIGHT DISTRIBUTIONS: See ordering guide.
LENS: Tempered clear flat borosilicate glass.
CONDUIT ENTRIES: Bottom openings are available in the cast bronze Junction Box.
Suitable for thru-branch wiring.
NOTE: Potting compound (PC21) recommended for junction box splices. PC21 sold
separately.
LISTING: U.L., IP68
WARRANTY: 5-year limited warranty. Complete warranty terms located
at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
NOTE: Actual performance may differ as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25°C.
Specifications subject to change without notice.
9144 Deering Ave. Second Floor • Chatsworth, CA 91311
Phone: 866.533.9901 • www.hydrel.com
©2014-2017 Acuity Brands Lighting, Inc.
03/21/17
9360_DO_LED