9360DO SERIES CATALOG NUMBER Monochromatic LED Drive-Over Flush Mounted Up-Light NOTES TYPE DESCRIPTION Hydrel’s Model 9360DO, is a bronze well light, incorporating some of the internal components of our M9400 Series. This fixture features drive over capacities, capable of supporting a wide variety of vehicle types and loads. The Soils Engineer or Pavement Designer must properly design this fixture into the supporting soil, subbase, and finishing surface. A properly designed pavement section could support the fixture for vertical and lateral loads up through AASHTO HS20 (20-ton truck-16000 Ibs. per wheel load @ 15 miles per hour). The smaller fixture footprint allows for placement in tight areas. Specifications L: 8 - 5/16” 211 mm 11” 279 mm 16 - 1/4” 413 mm W: H: 16 1/4" 16 1/4" EXAMPLE: 9360DO B DN 12LED BLU MVOLT NSP FLC 34B LP ORDERING INFORMATION Model* Material* Position* Lamp Type* LED Color* 9360DO Drive Over B UP Flange Up 12LED WHT30K White DN Flange Down WHT41K White WHT53K White AMBPC Phosphor Converted Amber BLU Blue GRN Green RED Red Bronze Distribution* Lens* NSP Narrow Spot FLC MFL Medium Flood FL Flood WFL Wide Flood Flat Lens Clear Voltage* Conduit Entry* Lamp* 34B 3/4” NPT bottom LP 25S1 Two 25mm side MVOLT (120 - 277V) Listing Lamp Installed IEC1 International Electrotechnical Commission VWFL Very Wide Flood (no optics) HSP Horizontal Spot HFL Horizontal Flood *Required Entries Notes: 1 Only for use in 50HZ applications. 9360 Series Assembly RISFD or RISFU consists of the following MACS Lamp Module individual components parts MHSL94 Power Module 9144 Deering Ave. Second Floor • Chatsworth, CA 91311 Phone: 866.533.9901 • www.hydrel.com ©2014-2017 Acuity Brands Lighting, Inc. 03/21/17 9360_DO_LED PERFORMANCE DATA LUMEN OUTPUT Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Actual performance may differ as a result of end-user environment and application. Contact factory for performance data on any configurations not shown here. 3000K 80CRI 4000K 70CRI 5000K 70CRI Distribution Nema Type Beam Angle (50%) HxV Field Angle (10%) HxV Watts LPW Delivered Lumens NSP 2x2 14.7 x 14.7 28 x 28 14 50 700 MFL 3x3 24.4 x 24.4 44 x 44 14 50 700 FL 6x6 74.5 x 70.8 104.2 x 102.1 14 36 500 WFL 6x6 102.5 x 100.4 129.6 x 129.1 14 43 600 HSP 3x3 21.6 x 21.6 39.9 x 39.9 14 50 700 600 HFL 4x3 39.3 x 15.7 59.6 x 29.9 14 43 VWFL 6x6 89.3 x 85.1 129.4 x 128.2 13 31 400 NSP 2x2 14.7 x 14.7 28 x 28 14 86 1,200 MFL 3x3 24.4 x 24.4 44 x 44 14 86 1,200 FL 6x6 74.5 x 70.8 104.2 x 102.1 14 64 900 WFL 6x6 102.5 x 100.4 129.6 x 129.1 14 79 1,100 HSP 3x3 21.6 x 21.6 39.9 x 39.9 14 86 1,200 HFL 4x3 39.3 x 15.7 59.6 x 29.9 14 79 1,100 VWFL 6x6 89.3 x 85.1 129.4 x 128.2 13 54 700 NSP 2x2 14.7 x 14.7 28 x 28 14 86 1,200 MFL 3x3 24.4 x 24.4 44 x 44 14 86 1,200 FL 6x6 74.5 x 70.8 104.2 x 102.1 14 64 900 WFL 6x6 102.5 x 100.4 129.6 x 129.1 14 79 1,100 HSP 3x3 21.6 x 21.6 39.9 x 39.9 14 86 1,200 HFL 4x3 39.3 x 15.7 59.6 x 29.9 14 79 1,100 VWFL 6x6 89.3 x 85.1 129.4 x 128.2 13 54 700 LED LIFE: L70/60,000 hours OPERATING TEMPERATURE: -30°C Through 40°C Lumen Ambient Temperature (LAT) Multipliers Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Ambient 0°C 10°C 20°C 25°C 30°C 40°C Lumen Multiplier 32°F 50°F 68°F 77°F 86°F 104°F 1.02 1.01 1.00 1.00 0.99 0.98 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the Fixture platform in a 25°C ambient, based on 8400 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Operating Hours 0 25,000 50,000 100,000 Lumen Maintenance Factor 1 0.99 0.98 0.96 Electrical Load Current (A) Light Drive Current Engines (mA) 12 LED 350mA System Watts 14 120 208 240 277 347 480 0.117 0.067 0.058 0.051 0.040 0.029 Load Rating A properly designed pavement section could support the fixture for vertical and lateral loads up through AASHTO HS20 (20-ton truck-16000 Ibs. per wheel load @ 15 miles per hour). FEATURES & SPECIFICATIONS ROUGH IN SECTION CONSTRUCTION: Cast bronze frame with stainless steel well. Specify flange up or flange down design with order. LAMP MODULE HOUSING: Stainless steel, sealed and purged of all moisture to -100°F. Electrical access to lamp module is done through submersible rated connector. POWER MODULE: LED driver is encapsulated in a custom designed heat-dissipating epoxy resin that also eliminates all moisture intrusion. Module is provided with submersible rated cord leads for connection to integral junction box and lamp module. LAMP TYPES: LED: Monochromatic LEDs, 12W. LAMP INCLUDED. VOLTAGE: MVOLT (120 - 277) Volts, 50 - 60 Hz. LIGHT DISTRIBUTIONS: See ordering guide. LENS: Tempered clear flat borosilicate glass. CONDUIT ENTRIES: Bottom openings are available in the cast bronze Junction Box. Suitable for thru-branch wiring. NOTE: Potting compound (PC21) recommended for junction box splices. PC21 sold separately. LISTING: U.L., IP68 WARRANTY: 5-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx NOTE: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25°C. Specifications subject to change without notice. 9144 Deering Ave. Second Floor • Chatsworth, CA 91311 Phone: 866.533.9901 • www.hydrel.com ©2014-2017 Acuity Brands Lighting, Inc. 03/21/17 9360_DO_LED
© Copyright 2025 Paperzz