obvious that AlCl3 is the dominant species in the high boilers. Broad signals in 27Al-NMR indicate low symmetry and broad signals were found for both the species at 117 ppm and AlCl3. Furthermore, reference measurements of methylaluminum chlorides showed that no such compound is present in the mixture. So the species causing the signal at 117 ppm remained unidentified, but since it has to be formed by reaction of the two aluminum species present in the product mixture, it most probably is closely related to AlCl3, possibly Al2Cl7-. In the disilane columns of the distillation the concentration of aluminum in the high boiling residues which are discharged as waste from the last distillation columns rises further to about 4500 ppm. Two more aluminum species at 40 ppm and 96 ppm can be found in NMR spectra of the residue (Figure 8). As can be seen, a major fraction of the aluminum species in the mixture still consists of AlCl3. Current Data Parameters NAME 2641997D-LIMS EXPNO 10 PROCNO 1 F2 - Acquisition Parameters Date 17.06.2014 Time 07.16.00 INSTRUM spect PROBHD 5 mm PABBO BBPULPROG zg TD 16384 SOLVENT CDCl3 NS 1024 DS 4 SWH 52083,333 FIDRES 3,178914 AQ 0,1572864 RG 574.7 DW 9,600 DE 7,00 TE 683,2 D1 1,00000000 Hz Hz sec usec usec K sec ======== CHANNEL f1 ======== NUC1 27Al P1 6,30 usec PL1 0,00 db SFO1 130,3183240 MHz AlCl3 MHz Hz cm cm ppm Hz ppm Hz ppm/cm Hz/cm Integrale F2 - Processing parameters SI 32768 SF 130,318329 WDW EM SSB 0 LB 1,00 GB 0 PC 1,40 1D NMR plot parameters CX 28,22 CY 16,16 F1P 159,040 F1 0,00 F2P -40,159 F2 0,00 PPMCM 7,06001 HZCM 0,00000 140 120 100 80 60 ppm 40 20 0 -20 -40 MiniSpec - Copyright Corporate Analytics Wacker Chemie AG Figure 6: 2 7 Al-NMR of the direct synthesis product mixture (Al concentration ~200 ppm, broad hump from 20 – 120 ppm caused by probe and cavity of the NMR spectrometer Current Data Parameters NAME 2648478D-LIMS EXPNO 10 PROCNO 1 F2 - Acquisition Parameters Date 03.07.2014 Time 08.52.25 INSTRUM spect PROBHD 5 mm PABBO BBPULPROG zg TD 16384 SOLVENT CDCl3 NS 1024 DS 4 SWH 52083,333 FIDRES 3,178914 AQ 0,1572864 RG 645.1 DW 9,600 DE 7,00 TE 298,2 D1 1,00000000 Hz Hz sec AlCl3 usec usec K sec ======== CHANNEL f1 ======== NUC1 27Al P1 6,30 usec PL1 0,00 db SFO1 130,3183240 MHz MHz Hz cm cm ppm Hz ppm Hz ppm/cm Hz/cm Integrale F2 - Processing parameters SI 32768 SF 130,318329 WDW EM SSB 0 LB 1,00 GB 0 PC 1,40 1D NMR plot parameters CX 28,22 CY 16,16 F1P 163,044 F1 0,00 F2P -39,909 F2 0,00 PPMCM 7,19305 HZCM 0,00000 160 140 120 100 80 60 ppm 40 20 0 -20 MiniSpec - Copyright Corporate Analytics Wacker Chemie AG Figure 7: 27 Al-NMR of the high boilings of the distillation process (Al concentration ~1700 ppm), broad hump from 20 – 120 ppm caused by probe and cavity of the NMR spectrometer 143
© Copyright 2026 Paperzz