High Current Line Filters for 3-phase systems FMAC Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 60950 Nominal current: Rated voltage UR (Umax): Attenuation: Leakage current: Test voltages for 480 V: Test voltages for 520 V: Climatic category: 50% saturation typ.: Inrush current: MTBF @ 40°C / UR (Umax ): 6 - 1100 A @ ϑ ϑa 40°C 480 and 520 VAC 50/60 Hz High for Industrial applications L→ E 3 kVDC, 2 sec * L → L 2.25 kVDC, 2 sec * L→ E 4 kVDC, 2 sec * L → L 2.25 kVDC, 2 sec * 25/100/21 acc. to IEC 60068-1 2 to 3 x IN @ 20°C 1.5 x IN 1 min. per hour > 200000 h acc. to MIL-HB-217 F *without resistors up to 250A Approvals obtained or pending: up to 110A All these filters are ideally suited for applications with EN 55011, EN 55014 and EN 55022 requirements. The TIMONTA high current filter family FMAC was developed for the following industrial applications: • Frequency Converters • Stepper Motor Drives • UPS-Systems • Inverters • All the versions include insulated safety screw terminals. • Optionally VHV version (up to 760 VAC) are available on request • Optionally, wire lead connections instead of the screw terminals are available (m.o.q. 50 pcs). • Key features of the high current filter range include: − easy, space saving installation − high symmetrical and asymmetrical mode attenuation (from 10 kHz to 300 MHz) • To maximize the filter performance in the application, the following EMC-rules should be considered: − physical separation of filter input and output lines − physical separation of the interference source itself − dedicated earth connection for the filter Three versions of these filters are available. The first one, most important, includes filters for applications where high performances are required, with maximum rated voltage 480VAC. The second has been developed for standard use, also up to 480 VAC. The third (HV) is similar to the first one but has a maximum rated voltage of 520VAC. These filters can also be used in IT power systems in which the voltage between phases and earth can reach 520 VAC. Technical data of the high performance version - Rated voltage UR (Umax.) 480 VAC Type IN (1) @ ϑa 40°C UR (Umax) 50/60 Hz [A] FMAC-0924-0610 FMAC-0931-0810 FMAC-0931-1610 FMAC-0932-1610 FMAC-0932-2510 FMAC-0934-3610 FMAC-0934-5010 FMAC-0953-6410 FMAC-0937-8010 FMAC-0954-H110 FMAC-0955-H210 FMAC-0956-H310 FMAC-0956-H410 FMAC-0957-H550 FMAC-0957-H650 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 x x x x x x x x x x x x x x x 6 8 16 16 25 36 50 64 80 110 180 250 340 450 550 [V] 480 480 480 480 480 480 480 480 480 480 480 480 480 480 480 LN (2) -30%/+50% [mH] 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 x x x x x x x x x x x x x x x 10 10 6 6 3 2 1 0.6 1 0.7 0.4 0.3 0.2 0.2 0.2 ResistancePower Max. leakage current L-L dissipation @ 440 V/50 Hz ± 15% [mΩ] total ± 15% [W] 23 28 11.5 11.5 4.4 3.32 1.3 1.1 1.17 0.75 0.37 0.2 0.13 0.06 0.046 2.48 5.38 8.83 8.83 8.25 12.91 9.75 13.52 22.60 27.23 36 36 45 40 45 In 3-phase systems (3) [mA] ≤ 5 C1 C2 C3 C4 Worst case (4) ± 20% ± 20% ± 20% ± 20% [mA] [µF] [µF] [nF] [nF] 40 40 40 40 156 156 160 160 167 167 167 175 176 176 176 1.0 1.0 1.0 1.0 4.4 4.4 4.4 4.4 6.6 6.6 6.6 11 11 11 11 − − − − 1 1 1 1 1 1 1 1 1 1 1 100 100 100 100 10 10 10 10 47 47 47 100 100 100 100 10 10 10 10 47 47 100 100 100 100 100 100 100 100 100 C5 ± 20% [µF] 2.2 2.2 2.2 2.2 4.4 4.4 4.4 4.4 6.6 6.6 6.6 11 22 22 22 C6 R1 R2 Case Terminal blocks ± 20% [µF] [MΩ] [MΩ] − − − − 1 1 1 1 1 1 1 1 1 1 1 − − − − 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.5 0.25 0.25 0.25 2 [mm ] 24-3 4 31-3 4 31-3 4 32-3 4 32-7 6 34-3 10 34-3 10 53-3 25 37-3 25 54-3 50 55-3 95 56-3 240 56-3 240 57 (A) 57 (A) (1) Current derating over 40°C : I = IN x (100-ϑa)/60 (2) Nominal inductance measured according to EN 138100, see introduction of this catalog, paragraph 3.4 (3) Measured according to IEC 60950 - 5.2.4 - 5.2.5, valid for TT and TN mains and with regular Sinus. See introduction of this catalog, paragraph 3.5 (4) Measured according to IEC 60950 - Annex G.4, valid for IT mains. See introduction of this catalog, paragraph 3.5 (A) Connection straps for M10 Circuit diagram Insertion losses and case designs see pages 78-79-80-81. Continues in the next page. 75 High Current Line Filters for 3-phase systems FMAC Series, all-purpose filters to Protection Class I, conform to EN 133200, UL 1283 and IEC 60950 Technical data for the standard version - Rated voltage UR (Umax.) 480VAC Type IN (1) @ ϑa 40°C UR (Umax) 50/60 Hz FMAC-0932-2510L FMAC-0932-3610L FMAC-0934-5010L FMAC-0934-6410L 3 3 3 3 [A] [V] x x x x 480 480 480 480 25 36 50 64 LN (2) -30%/+50% [mH] 3 3 3 3 x x x x 2.4 1.5 1 0.6 ResistancePower Max. leakage current L-L dissipation @ 440 V/50 Hz ± 15% [mΩ] total ± 15% [W] 5.26 2.71 1.68 1.48 9.86 10.55 12.63 18.23 In 3-phase systems (3) [mA] Insertion losses and case designs see pages 78-79-80-81 C2 C3 C4 C5 Worst case (4) ± 20% ± 20% ± 20% ± 20% [mA] [µF] [µF] [nF] [nF] ± 20% [µF] 4.4 4.4 4.4 4.4 1 1 1 1 4.4 4.4 4.4 4.4 C1 C2 156 156 160 160 ≤ 5 C1 10 10 10 10 47 47 100 100 C6 R1 R2 Case Terminal blocks ± 20% [µF] [MΩ] [MΩ] 1 1 1 1 1 1 1 1 1 1 1 1 2 [mm ] 32-3 32-7 34-3 34-3 4 6 10 10 Technical data for the HV version and IT supply compatible Rated voltage UR (Umax.) 520VAC Type IN (1) @ ϑa 40°C UR (Umax) 50/60 Hz [A] FMAC-0931-1612I FMAC-0932-2512I FMAC-0934-3612I FMAC-0934-5012I FMAC-0953-6412I FMAC-0937-8012I FMAC-0954-H112I FMAC-0955-H212I FMAC-0956-H312I FMAC-0956-H412I FMAC-0974-K152I 3 3 3 3 3 3 3 3 3 3 3 x x x x x x x x x x x 16 25 36 50 64 80 110 180 250 340 1100 [V] 520 520 520 520 520 520 520 520 520 520 520 Insertion losses and case designs see pages 78-79-80-81 LN (2) -30%/+50% [mH] 3 3 3 3 3 3 3 3 3 3 3 x x x x x x x x x x x ResistancePower Max. leakage current L-L dissipation @ 480 V/50 Hz total ± 15% [W] ± 15% [mΩ] 6 11.5 3 4.4 2 3.32 1 1.3 0.6 1.1 1 1.17 0.7 0.75 0.4 0.37 0.3 0.2 0.2 0.13 0.12 0.022 In 3-phase systems (3) [mA] 8.83 8.25 12.91 9.75 13.52 22.60 27.23 36 36 45 80 ≤ 5 C3 C4 Worst case (4) ± 20% ± 20% ± 20% ± 20% [mA] [µF] [µF] [nF] [nF] 26 172 172 172 172 179 179 179 185 188 182 1.5 3 3 3 3 4.5 4.5 4.5 7.5 7.5 11 − 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 50 50 50 50 50 50 50 50 50 50 − 11 11 11 11 11 50 50 50 50 50 − C5 ± 20% [µF] 1.5 3 3 3 3 4.5 4.5 4.5 7.5 15 22 C6 R1 R2 Case Terminal blocks ± 20% [µF] [MΩ] [MΩ] − 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 − 1 1 1 1 1 1 1 1 1 0.5 2 2 2 2 2 2 2 2 2 2 0.25 2 [mm ] 31-3 4 32-7 6 34-3 10 34-3 10 53-3 25 37-3 25 54-3 50 55-3 95 56-3 240 56-3 240 74 (A) (100-ϑa)/60 (1) Current derating over 40°C : I = IN x (2) Nominal inductance measured according to EN 138100, see introduction of this catalog, paragraph 3.4 (3) Measured according to IEC 60950 - 5.2.4 - 5.2.5, valid for TT and TN mains and with regular Sinus. See introduction of this catalog, paragraph 3.5 (4) Measured according to IEC 60950 - Annex G.4, valid for IT mains. See introduction of this catalog, paragraph 3.5 (A) Connection straps for M12 Drives Rating - Recommended Filter Type Motor rating 400VAC [PS / HP] [kW] 1 2 5 10 15 20 25 30 38 60 87 133 160 227 400 0.75 1.5 3.7 7.5 11 15 18.5 22.5 28 45 65 100 120 170 300 Converter rating [kVA] to to to to to to to to to to to to to to to 1.5 2.9 6.8 12.2 20 26 30 40 50 85 120 160 200 260 500 Recommended filter IN [A] (*) Circuit diagram 6 8 16 25 36 50 64 80 110 180 250 340 450 550 1100 (*) The exact current value depends of the efficiency of the converter and the application (current effective value). Insertion losses and case designs see pages 78-79-80-81. 76 High Current Line Filters for 3-phase + neutral systems FMAC / FMAD Series, Insertion loss Insertion loss FMAC high performance The symmetrical and asymmetrical attenuation curves of the HV version and the FMAD serie correspond approximately to the equivalent FMAC high performance models. Variations are within the read-out precision of the curves. Insertion loss FMAC standard 78 High Current Line Filters for 3-phase + neutral systems FMAC / FMAD / FMBC Series, Cases Case 24-4 (24-3) Case 27-4 (27-3) Case 31-4 (31-3) Case 32-4 (32-3) Case 32-8 (32-7) 79 High Current Line Filters for 3-phase + neutral systems FMAC / FMAD / FMBC Series, Cases Case 34-4 (34-3) Case 37-4 (37-3) Case 38-4 (38-3) Case 40-3 Case 53-4 (53-3) 80 High Current Line Filters for 3-phase + neutral systems FMAC / FMAD Series, Cases Case 54-4 (54-3) Case 55-4 (55-3) Case 56-4 (56-3) Case 57 Case 74 81
© Copyright 2026 Paperzz