Air curtains ELiS B Table of Contents General characteristic...............................................................................................................................................................3 Construction..............................................................................................................................................................................................4 Dimensions..................................................................................................................................................................................................5 Technical data.........................................................................................................................................................................................5 Nomograms of air flow velocity.............................................................................................................................7 Installation.....................................................................................................................................................................................................8 Control systems – comparison.................................................................................................................................9 Control systems – TS control........................................................................................................................................9 Control systems – T-box control............................................................................................................................9 T-box control – functions.............................................................................................................................................. 10 BMS programming.................................................................................................................................................................... 11 FLOWAIR System........................................................................................................................................................................... 12 Elements of control systems................................................................................................................................... 13 Connection diagram – TS control.................................................................................................................. 14 Connection diagram – T-box control....................................................................................................... 14 Heating capacity tables – ELiS B-W-100............................................................................................. 15 Heating capacity tables – ELiS B-W-150............................................................................................. 15 Heating capacity tables – ELiS B-W-200............................................................................................. 16 Heating capacity tables – ELiS B-W-100 2R.................................................................................. 17 Heating capacity tables – ELiS B-W-150 2R.................................................................................. 17 Heating capacity tables – ELiS B-W-200 2R.................................................................................. 17 Heating capacity tables – ELiS B-E-100/150/200............................................................... 18 2 www.flowair.com General characteristic Air curtain ELiS B Max. range(1) [m] Heating capacity(2) [kW] Air flow [m3/h] Weight [kg] Materials Colour (1) (2) 5 10,9–49,9 2200–6600 31,7–56,4 steel, plastic, EPP, aluminium white (RAL 9016) Vertical range of isothermal stream, at velocity limit above 2 m/s For B-W during operation at 3rd step, at inlet air temperature 10oC and water temperature 90/70oC ELiS B air curtains are used to secure the rooms against heat losses and uncontrolled heat gains. They are installed in suspended ceilings and reduce heat losses associated with air exchange between room and environment. Additionally, they successfully protect the room against insects and dust. ELiS B air curtains: • are available in 3 lengths: 1 m, 1,5 m or 2 m • are available in 3 versions: – without heating elements (ambient) (N) – with water heat exchanger (W) – with electric heaters (E) • are designed for installation in suspended ceilings B-N/W/E-100 B-N/W/E-150 DESIGNATION OF ELiS B AIR CURTAINS B-W-100 2R B— ELiS B, range of air curtain 5 m N— curtain without heat exchanger (ambient) W— curtain with water heat exchanger E — curtain with electric heaters B-N/W/E-200 100/150/200 — length of air outlet 2R – two rows heat exchanger www.flowair.com 3 Construction SIMPLE CONSTRUCTION Simple and lightweight construction thanks to combination of metal and plastic elements. BMS CONTROL SYSTEM Control systems are BMS compatible. DIAGONAL FAN High efficiency of the units thanks to motor propelling a set of diagonal rotors. INSTALLATION ELiS B air curtains are redy for installation in existing suspended ceilings. The are equipped with holders, which enable simple and easy installation of the unit. ADJUSTABLE AIR STREAM Adjustment of the air stream barrier using regulated air deflectors. 4 www.flowair.com Dimensions B-N/W/E-150 B-N/W/E-200 (1) 2034 1546 1057 284 300(1) 600 B-N/W/E-100 Dotyczy kurtyny z wymiennikiem wodnym B-W Technical data B-N-100 B-W-100 B-E-100 Fan B-N-150 B-W-150 B-E-150 B-N-200 B-W-200 B-E-200 motor with diagonal rotor Max. air flow stream of curtain [m /h] 3 Power supply [V/Hz] 3500 230/50 2600 230/50 4800 3x400/50 230/50 4000 230/50 6600 3x400/50 230/50 5200 230/50 3x400/50 Max. current consumption of fan [A] 1,9 1,5 2,0 1,6 2,2 1,7 Power consumption of fan [kW] 0,42 0,34 0,44 0,36 0,49 0,38 64 62 65 63 66 64 IP 21 Max. acoustic pressure level of unit(1) [dB(A)] Max. range of air stream [m] 5 (2) B-N-100 B-N-150 B-N-200 Fan setting I step II step III step I step II step III step I step II step III step Air flow [m3/h] 2300 2700 3500 3200 4000 4800 3600 4300 6600 Current consumption of fan [A] 1,3 1,6 1,9 1,6 1,7 2,0 1,6 1,9 2,2 Power consumption of fan [kW] 0,29 0,35 0,42 0,36 0,38 0,44 0,35 0,41 0,49 Acoustic pressure level(1) [dB(A)] 56 60 64 56 60 65 58 63 66 Weight of unit [kg] Fan setting I step 31,7 38,9 7,2 B-W-100 B-W-150 B-W-200 II step III step I step Heat exchanger II step III step I step II step III step Cu–Al, one row Air flow [m3/h] 2200 2500 2600 3200 3500 4000 4000 4300 5200 Current consumption of fan [A] 1 1,1 1,5 1,1 1,2 1,6 1,2 1,3 1,7 Power consumption of fan [kW] 0,22 0,24 0,34 0,24 0,26 0,36 0,26 0,29 0,38 Acoustic pressure level [dB(A)] (1) Heating capacity(3) [kW] Air temperature rise for curtain (ΔT)(3) [°C] 54 58 62 55 59 63 56 61 64 10,9 11,6 11,9 18,2 19,1 20,5 24 25 27,7 15 14 15 17 16 15 18 17 16 Max. water pressure [MPa] 1,6 Max. water temperature [°C] 95 Connection [”] 1/2 Weight of unit [kg] 32,3 41,2 50 Weight of unit filled with water [kg] 33,1 42,2 51,6 Acoustic pressure level measured in the room with average sound absorption, capacity 500 m3, at distance of 3 m from the unit Vertical range of isothermal stream, at velocity limit above 2 m/s (3) For operation at 3rd step, at inlet air temperature 10oC, for B-W at inlet/outlet water temperature 90/70oC (1) (2) www.flowair.com 5 Dane techniczne B-W-100 2R Fan setting I bieg II bieg B-W-150 2R III bieg I bieg Heat exchanger II bieg B-W-200 2R III bieg I bieg II bieg III bieg 2-rzędowy Cu-Al. Air flow [m3/h] 2000 2300 2400 3000 3200 3800 3800 4100 4900 Current consumption of fan [A] 1 1,1 1,5 1,1 1,2 1,6 1,2 1,3 1,7 Power consumption of fan [kW] 0,22 0,24 0,34 0,24 0,26 0,36 0,26 0,29 0,38 Acoustic pressure level(1) [dB(A)] 54 58 62 55 59 63 56 61 64 18,9 20,5 21 31,8 33,1 36,7 42,2 44,2 49,9 28 26 26 31 31 29 33 32 29 Heating capacity [kW] (3) Air temperature rise for curtain (ΔT)(3) [°C] Max. water pressure [MPa] 1,6 Max. water temperature [°C] 95 Connection [”] 1/2 – gwint wewnętrzny Weight of unit [kg] 33,7 43,7 53,2 Weight of unit filled with water [kg] 35,2 45,7 56,4 B-E-100 B-E-150 B-E-200 Fan setting I bieg II bieg III bieg I bieg II bieg III bieg I bieg II bieg III bieg Air flow [m /h] 2200 2500 2600 3200 3500 4000 4000 4300 5200 Current consumption of fan [A] 1,0 1,1 1,5 1,1 1,2 1,6 1,2 1,3 1,7 3 Power consumption of fan [kW] 0,22 0,24 0,34 0,24 0,26 0,36 0,26 0,29 0,38 Acoustic pressure level(1) [dB(A)] 54 58 62 55 59 63 56 61 64 Heat source 2 x grzejny element PTC Power supply [V/Hz] 3 x grzejny element PTC 4 x grzejny element PTC 3x400/50 Rated current of unit(3) [A] 11 16,6 22,4 Heating capacity [kW] 7,5 11,5 15,5 Air temperature rise for curtain (ΔT)(3) [°C] 11 12 13 34,5 42,3 53,2 (3) Weight of unit [kg] Acoustic pressure level measured in the room with average sound absorption, capacity 500 m3, at distance of 3 m from the unit (2) Vertical range of isothermal stream, at velocity limit above 2 m/s (3) For operation at 3rd step, at inlet air temperature 10oC, for B-W at inlet/outlet water temperature 90/70oC (1) 6 www.flowair.com Nomograms of air flow velocity B-N-100 12,0 12,0 10,0 10,0 air velocity [m/s] air velocity [m/s] B-W-100; B-E-100 8,0 6,0 4,0 2,0 8,0 6,0 4,0 2,0 0,0 0,0 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 0 0,5 1 distance from the outlet [m] 2,5 3 3,5 4 4,5 5 4,5 5 4,5 5 B-N-150 12,0 12,0 10,0 10,0 air velocity [m/s] air velocity [m/s] 2 distance from the outlet [m] B-W-150; B-E-150 8,0 6,0 4,0 2,0 8,0 6,0 4,0 2,0 0,0 0,0 0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5 0 0,5 1 distance from the outlet [m] 1,5 2 2,5 3 3,5 4 distance from the outlet [m] B-W-200; B-E-200 B-N-200 12,0 12,0 10,0 10,0 air velocity [m/s] air velocity [m/s] 1,5 8,0 6,0 4,0 2,0 8,0 6,0 4,0 2,0 0,0 0,0 0 0,5 1 1,5 2 2,5 3 3,5 4 distance from the outlet [m] 4,5 5 0 0,5 1 1,5 2 2,5 3 3,5 4 distance from the outlet [m] step 1 step 2 step 3 www.flowair.com 7 Installation ELiS B air curtains are equipped with holders, which enable installation in suspended ceilings. Casing of the unit was designed to enable installation in already existing ceilings, without cutting bigger holes or service hatches. Installation of the unit does not require preparing additional holes in the ceiling. Access from the front makes it easier to instal, connect and clean the air curtain. max. 5 m Brackets for installation using pins are included. Installation in suspended ceiling F D E C G A Installation distances [mm] ELiS B-N/W/E-100 ELiS B-N/W/E-150 ELiS B-N/W/E-200 8 B A 1024 1510 2000 B 572 572 572 C 133 182 256 D 770 1207 1621 E 121 122 123 F 561 561 561 G 248 248 248 www.flowair.com Control systems Comparison of control systems TS control T-box control 5 31 Controlling options Manual 3-step air flow control Modes Heating / Ventilation Operation depending on door sensor and temperature Weekly programmer BMS Curtain switch off delay Idle speed mode Integration with FLOWAIR SYSTEM Max. number of connected units Via controller Type of controller TS – 3-step fan speed controller with thermostat T-box – intelligent controller with touch screen Type of fan AC – standard 3-step fan TS control T-box control TS ELiS B air curtain is equipped with control system, enabling you to connect: T-box ELiS B air curtain is equipped with control system, enabling you to connect: • DCm/DCe door sensor, • DCm/DCe door sensor, • TS 3-step fan speed controller with thermostat. • T-box intelligent controller with touch screen. Controller enables choice of 2 operating modes: • Configuration 1 - curtain operation when overriding signal comes from door sensor as well as from 3-step fan speed controller with thermostat. • Configuration 2 - curtain operation when overriding signal comes from door sensor, while 3-stem fan speed controller with thermostat is responsible for fan speed control and heating engagement signal. Controller enables choice of 2 operating modes: • Configuration 1 - curtain operation when overriding signal comes from door sensor as well as from T-box controller. • Configuration 2 - curtain operation when overriding signal comes from door sensor, while T-box is responsible for fan speed control and heating engagement signal. The control system is ready for chaining of the curtains and is able to control up to 31 units via a single T-box controller. CHAINING OF CURTAINS: CHAINING OF CURTAINS: The control system is ready for chaining of the curtains and is able to control up to 5 units via single TS controller. Control system is adapted to chaining the curtains and controlling up to 31 units via single T-box controller. BMS: BMS: The control system can be connected to BMS- intelligent building management system. This solution enables you to save and load operating parameters of the curtain (e.g. fan step). T-box controller can be connected to BMS-intelligent building management system. This solution enables you to control all of the units, which communicate with T-box controller. www.flowair.com 9 T-box control - functions Idle speed mode When the doors are closed, fans are operating with a lower speed. This solution eliminates delay in the air barrier formation, which is caused by the time needed to switch on the fans. A) Doors are closed – fans operate with a lower speed. B) Doors are opening – speed of fan is rising. C) Doors are closing – fans still operate with increased speed. D) Doors are closed – fan operate with a lower speed again. Curtain switch off delay time If the doors in the building keep opening and closing constantly, it is possible to set a switch-off time delay. After closing the doors, curtain is still operating for the set time. If the doors open shortly, there is no need to switch off/on the curtain again. This solution increases reliability of the components and improves the air barrier effectiveness. A) Doors are closed – fans are stopped. 10 B) Doors are open – fans operate with speed set on the controller. C) Doors are closed – fans operate for a delay time set by the user. D) Doors are closed – fans will switch off after delay time. www.flowair.com BMS programming Version 1 In the case of controlling the units via T-box controller using one address in BMS it is possible to control up to 31 units independently. Communication parameters: Name Description Physical layer RS485 Protocol MODBUS-RTU Transmission rate 9600, 19200, 38400, 57600, 115200 LUB 230400 [bps] Parity Even Number of data bits 8 Number of stop bits 1 Version 2 ELiS B curtains are equipped with a BMS compatible control system. It is possible to set up to 31 addresses. Setting the address for each unit enables independent loading and saving their operating parameters separately. Communication parameters: Name Physical layer Protocol Transmission rate Parity Number of data bits Number of stop bits www.flowair.com Description RS485 MODBUS-RTU 38400 [bps] Even 8 1 11 FLOWAIR System FLOWAIR SYSTEM is a complete offer of heating and ventilation devices integrated with one T-box controller enabling you to control all the units from one location. ELiS DUO curtain-heater combo units LEO fan heaters ELiS air curtains Integration and control of all the devices with a single T-box controller OXeN ductless ventilation with heat recovery T-box intelligent controller with touch screen LEO D air destratificator 12 www.flowair.com Elements of control systems Category Name Picture Technical data T-box intelligent controller with touch screen Protection degree: IP 20 Power supply: 24 VDC Operating temperature range: -10 … +60°C Temperature adjustment range: +5 … +35oC TS 3-step fan speed controller with thermostat Protection degree: IP30 Temperature adjustment range: +10 … +30°C Operating temperature range: 0 … +40oC Contacts load: inductive 5 A, resistance 6 A Controller DCe magnetic door sensor Operating temperature range: -5 … +60°C Protection degree: IP64 Material: plastic Length of connection wire: 2 m Jumpers: NC Resistance contacts load: 0,5 A Max. contacts voltage: 175 VDC Max. distance between contacts: 8 mm DCm mechanical door sensor Operating temperature range: -10 … +80°C Protection degree: IP65 Material: plastic Length of connection wire: none Jumpers: 1xNC i 1xNO Inductive contacts load: 3 A Max. contacts voltage: 300 VAC or 250 VDC Door sensors SRQ2d two-way valve 1/2” with actuator Protection degree: IP20 Power supply: 200–240 V 50/60 Hz Max. water temperature: +93oC Max. water pressure: 1,6 MPa Kvs: 3,0 m3/h Installation: on water outlet pipe Opening/closing time: 18s/5s Dimensions (HxWxD): 108x86x66 mm SRQ3d three-way valve 1/2” with actuator Protection degree:IP20 Power supply: 200–240 V 50/60 Hz Max. water temperature: +93oC Max. water pressure: 2 MPa Kvs: 3,4 m3/h Installation: on water inlet pipe Opening/closing time: 18s/5s Dimensions (HxWxD): 118x86x66 mm Valves with actuator www.flowair.com 13 Connection diagrams TS control Control via DCe or DCm door sensor and TS 3-step fan speed controler with thermostat. DCe TS DCm SRQ SRQ or min. 2×0,5 mm2 min. 5×0,5 mm2 min. 3×0,75 mm2 min. 5×4,0 mm2 3x400 V/50 Hz ELiS B-E min. 3×1,0 mm2 230 V/50 Hz ELiS B-N/W power supply power supply SRQ power supply max. 5 units ELiS B T-box control Control via DCe or DCm door sensor and T-box controller. T-box DCe DCm SRQ SRQ or min. 2×0,5 mm2 min. 3×0,75 mm2 LIYCY min. 4x0,5 mm2 A and B braided wire pair max. 50 m min. 5×4,0 mm2 3x400 V/50 Hz ELiS B-E min. 3×1,0 mm2 230 V/50 Hz ELiS B-N/W power supply power supply SRQ power supply 14 max. 31 units compatible with FLOWAIR SYSTEM www.flowair.com Heating capacities ELiS B with one row water heat exchanger ELiS B-W-100 Tp1 °C V m3/h PT kW 0 5 10 15 20 2200/ 2500/ 2600 12,6/13,5/13,8 11,8/12,6/12,8 10,9/11,6/11,9 10,0/10,7/10,9 9,1/9,7/9,9 0 5 10 15 20 2200/ 2500/ 2600 8,5/9,0/9,2 7,5/8,1/8,2 6,6/7,1/7,2 5,7/6,1/6,2 4,7/5,0/5,1 0 5 10 15 20 2200/ 2500/ 2600 6,2/6,6/6,8 5,2/5,6/5,7 4,1/4,5/4,6 2,0/2,1/2,1 1,6/1,7/1,7 Qw Δpw l/h kPa Tw1/Tw2 = 90/70oC 558/597/609 1,9/2,2/2,3 519/555/566 1,7/1,9/2,0 480/513/524 1,5/1,6/1,7 441/471/481 1,3/1,4/1,5 402/429/438 1,1/1,2/1,2 Tw1/Tw2 = 70/50oC 370/396/404 1,0/1,1/1,2 330/353/360 0,7/0,8/0,9 290/310/316 0,6/0,6/0,7 248/266/271 0,5/0,5/0,6 204/220/225 0,3/0,4/0,4 Tw1/Tw2 = 60/40oC 269/289/295 0,6/0,6/0,7 226/243/249 0,4/0,4/0,5 178/193/198 0,3/0,3/0,3 88/90/91 0,1/0,1/0,1 72/74/74 0,1/0,1/0,1 Tp2 °C PT kW 17,0/16,0/15,5 21,0/20,0/19,5 24,5/23,5/24,5 28,0/27,5/27,0 32,0/31,5/31,0 10,6/11,3/11,5 9,7/10,4/10,6 8,8/9,4/9 7,9/8,5/8,6 7,0/7,5/7,6 11,5/11,0/10,5 15,0/14,5/14,0 19,0/18,5/18,0 22,5/22,0/21,5 26,0/25,5/25,0 5,3/5,8/5,9 2,8/2,9/2,9 2,5/2,5/2,6 2,1/2,2/2,2 1,8/1,8/1,8 8,5/8,0/7,5 12,0/12,0/11,5 15,5/15,0/15,0 18,0/17,5/17,5 22,5/22,0/22,0 6,8/7,3/7,5 5,9/6,3/6,5 5,0/5,3/5,6 4,0/4,3/4,4 3,1/3,3/3,4 Tp2 °C PT kW 19,6/18,5/17,5 23,0/22,5/21,5 27,0/26,0/25,0 30,5/30,0/30,0 34,0/33,5/32,5 17,8/18,7/20,0 16,4/17,3/18,5 15,0/15,8/17,0 13,7/14,3/15,4 12,3/12,9/13,8 13,5/13,0/12,5 17,5/16,5/16,0 21,0/20,5/20,0 24,5/24,0/23,5 28,0/27,5/27,5 11,5/12,1/13,0 10,1/10,5/11,3 8,6/9,0/9,7 7,0/7,3/7,9 5,1/5,4/6,0 10,5/10,0/9,5 14,5/14,0/13,5 18,0/17,5/17,0 21,5/21,0/21,0 25,0/24,5/24,5 11,5/12,0/13,0 10,1/10,6/11,4 8,7/9,1/9,8 7,3/7,6/8,2 5,8/6,1/6,5 Qw Δpw l/h kPa Tw1/Tw2 = 80/60oC 465/497/507 1,4/1,6/1,7 426/455/464 1,2/1,3/1,4 386/413/395 1,0/1,1/1,1 347/370/378 0,8/0,9/1,0 306/328/334 0,7/0,8/0,8 Tw1/Tw2 = 70/40oC 153/168/172 0,2/0,2/0,3 83/85/86 0,1/0,1/0,1 72/74/75 0,1/0,1/0,1 62/63/64 0,1/0,1/0,1 51/53/53 0,1/0,1/0,1 Tw1/Tw2 = 50/40oC 594/636/649 2,4/2,7/2,8 514/550/562 1,9/2,1/2,2 434/464/474 1,4/1,5/1,6 352/377/385 0,9/1,1/1,1 266/285/292 0,6/0,6/0,7 Tp2 °C 14,0/13,5/13,0 18,0/17,5/17,0 21,5/21,0/21,5 25,5/25,0/24,5 29,5/29,0/28,5 7,0/6,5/6,5 9,0/8,5/8,5 13,5/13,0/12,5 18,0/17,5/17,5 22,5/22,0/22,0 9,5/9,0/8,5 13,0/12,5/12,5 17,0/16,5/16,0 20,5/20,0/20,0 24,5/24,0/24,0 ELiS B-W-150 Tp1 °C V m3/h PT kW 0 5 10 15 20 3200/ 3500/ 4000 20,9/21,9/23,5 19,6/20,5/22,0 18,2/19,1/20,5 16,8/17,6/19,0 15,5/16,2/17,4 0 5 10 15 20 3200/ 3500/ 4000 14,7/15,4/16,5 13,3/13,9/15,0 11,9/12,5/13,4 10,5/11,0/11,78 9,0/9,5/10,2 0 5 10 15 20 3200/ 3500/ 4000 11,5/12,0/13,0 10,1/10,5/11,5 8,6/9,0/9,7 7,1/7,5/8,1 5,6/5,9/6,3 Qw Δpw l/h kPa Tw1/Tw2 = 90/70oC 923/968/1039 5,9/6,5/7,4 863/905/972 5,3/5,6/6,6 803/842/904 4,6/5,0/5,7 742/779/835 4,0/4,4/5,0 682/715/767 3,4/3,7/4,2 Tw1/Tw2 = 70/50oC 642/674/723 3,3/3,6/4,0 581/610/655 2,7/3,0/3,4 520/546/585 2,2/2,4/2,8 458/481/516 1,8/1,9/2,2 395/415/445 1,4/1,5/1,7 Tw1/Tw2 = 60/40oC 500/525/563 2,2/2,4/2,7 438/460/494 1,7/1,9/2,1 375/394/423 1,3/1,4/1,6 311/327/351 0,9/1,0/1,1 243/256/276 0,6/0,7/0,7 Qw Δpw l/h kPa Tw1/Tw2 = 80/60oC 783/821/881 4,5/4,9/5,6 722/758/813 3,9/4,3/4,9 662/694/745 3,3/3,6/4,1 601/630/676 2,8/3,0/3,5 539/566/607 2,3/2,5/2,8 Tw1/Tw2 = 70/40oC 335/352/378 1,0/1,1/1,3 293/307/330 0,8/0,9/1,0 249/262/281 0,6/0,7/0,8 202/213/230 0,4/0,5/0,5 147/158/173 0,2/0,3/0,3 Tw1/Tw2 = 50/40oC 1001/1050/1128 7,7/8,4/9,5 878/922/990 6,1/6,6/7,5 755/793/851 4,6/5,0/5,7 631/662/711 3,3/3,6/4,1 505/530/568 2,2/2,4/2,8 Tp2 °C 16,5/16,0/15,0 20,0/19,5/18,5 24,0/23,0/22,5 27,5/27,0/26,5 31,0/30,5/30,0 10,5/10,0/9,6 14,5/14,0/13,5 18,0/17,5/17,0 21,5/21,0/20,5 24,5/24,5/24,0 10,5/10,0/9,5 14,5/14,0/13,5 18,0/17,5/17,0 21,5/21,5/21,0 25,5/25,0/24,5 To obtain operating parameters concerning other water temperatures, please contact Sales Office. Tw1 Tw2 Tp1 www.flowair.com Tp2 PT –heating capacity Tp1 –inlet air temperature Tp2 –outlet air temperature Tw1 –inlet water temperature Tw2 –outlet water temperature Qw –water stream flow in the heat exchanger Δpw–water pressure drop in the heat exchanger 15 Heating capacities ELiS B with one row water heat exchanger ELiS B-W-200 Tp1 °C V m3/h PT kW 0 5 10 15 20 4000/ 4300/ 5200 27,6/28,7/31,8 25,8/26,9/29,7 24,0/25,0/27,7 22,3/23,2/25,7 20,5/21,4/23,6 0 5 10 15 20 4000/ 4300/ 5200 19,7/20,5/22,5 17,9/18,6/20,5 16,1/16,7/18,5 14,5/14,8/16,4 12,4/12,9/14,3 0 5 10 15 20 4000/ 4300/ 5200 15,6/16,3/18,0 13,8/14,4/15,9 12,0/12,5/13,8 10,1/10,5/11,6 8,2/8,5/9,5 Qw Δpw l/h kPa Tw1/Tw2 = 90/70oC 1217/1266/1402 11,4/12,2/14,7 1140/1186/1312 10,0/10,8/13,0 1063/1105/1223 8,9/9,5/11,5 985/1024/1133 7,7/8,3/10,0 907/943/1043 6,6/7,1/8,8 Tw1/Tw2 = 70/50oC 860/894/990 6,4/6,9/8,3 782/813/900 5,4/5,8/6,9 703/731/809 4,5/4,7/5,7 624/649/717 3,6/3,8/4,6 544/565/625 2,8/3,0/3,6 Tw1/Tw2 = 60/40oC 681/708/784 4,6/4,7/5,6 602/626/693 3,5/3,7/4,5 522/543/601 2,7/2,9/3,5 441/458/507 2,0/2,1/2,6 357/372/412 1,4/1,5/1,8 Tp2 °C PT kW 20,5/19,5/18,0 24,0/23,5/22,0 27,5/27,0/25,7 32,5/30,5/29,5 35,0/34,5/33,0 23,6/24,6/27,7 21,9/22,7/25,2 20,1/20,9/23,1 18,3/19,0/21,0 16,5/17,2/19,0 14,5/14,0/13,0 18,0/17,5/17,0 21,5/21,5/20,5 25,5/25,0/24,5 29,0/28,5/28,0 16,1/16,7/18,5 14,3/14,8/16,4 12,4/12,9/14,2 10,4/10,9/12,0 8,4/8,8/9,6 11,5/11,0/10,5 15,0/15,0/14,0 18,5/18,5/18,0 22,5/22,0/21,5 26,0/25,5/25,0 15,3/15,9/17,6 13,5/14,0/15,5 11,6/12,1/13,4 9,8/10,2/11,3 7,9/8,3/9,1 Qw Δpw l/h kPa Tw1/Tw2 = 80/60oC 1038/1080/1195 8,7/9,4/11,3 961/999/1106 7,6/8,2/9,8 883/918/1016 6,5/7,0/8,4 804/836/925 5,5/5,9/7,1 725/754/834 4,6/4,9/5,9 Tw1/Tw2 = 70/40oC 468/487/538 2,2/2,3/2,8 414/431/477 1,8/1,9/2,3 360/374/414 1,4/1,5/1,8 304/316/350 1,0/1,1/1,3 245/256/284 0,7/0,7/0,9 Tw1/Tw2 = 50/40oC 1327/1380/1529 14,8/15,9/19,2 1170/1217/1348 11,8/12,7/15,2 1012/1052/1165 9,1/9,7/11,7 852/886/981 6,6/7,1/8,6 690/718/794 4,6/4,9/5,6 Tp2 °C 17,5/17,0/15,5 21,1/20,5/19,5 25,0/24,5/22,5 28,5/28,0/27,0 32,0/31,5/30,5 12,0/11,5/10,5 15,5/15,0/14,5 19,0/19,0/18,0 22,5/22,5/21,5 26,0/26,0/25,5 11,5/11,0/10,0 15,0/14,5/13,5 18,5/18,5/17,5 22,5/22,0/21,5 25,5/25,5/25,0 To obtain operating parameters concerning other water temperatures, please contact Sales Office. Tw1 Tw2 PT –heating capacity Tp1 –inlet air temperature Tp2 –outlet air temperature Tw1 –inlet water temperature Tw2 –outlet water temperature Qw –water stream flow in the heat exchanger Δpw–water pressure drop in the heat exchanger Tp1 Tp2 16 www.flowair.com Heating capacities ELiS B with two rows water heat exchanger ELiS B–W–100 2R Tp1 °C 0 5 10 15 20 0 5 10 15 20 V m3/h 2000/ 2300/ 2400 2000/ 2300/ 2400 PT kW 22,0/23,9/24,5 20,4/22,2/22,8 18,9/20,5/21,0 17,4/18,8/19.3 15,8/17,2/17,6 15,1/13,5/11,8 13,5/14,2/14,6 11,8/12,5/12,8 10,1/10,7/11,0 8,3/8,8/9,0 Qw Δpw l/h kPa Tw1/Tw2 = 90/70oC 970/1053/1080 1,49/1,74/1,82 902/980/1004 1,31/1,52/1,59 834/906/928 1,13/1,32/1,38 766/832/852 0,97/1,13/1,18 697/757/776 0,82/0,95/0,99 Tw1/Tw2 = 70/50oC 662/699/716 0,79/0,87/0,91 590/623/639 0,64/0,71/0,74 517/546/560 0,51/0,56/0,58 441/467/479 0,38/0,42/0,44 362/384/395 0,27/0,3/0,31 Tp2 °C PT kW 33/31/30 35/34/33 38/36/36 40/39/39 43/42/41 18,9/20,0/20,5 17,3/18,3/18,8 15,7/16,6/17,0 14,1/14,9/15,3 12,5/13,1/13,5 21/21/20 24/23/23 27/26/26 29/29/28 31/31/31 10,7/11,6/12,0 8,8/9,7/10,0 6,6/7,6/7,8 3,8/4,0/4,0 3,1/3,2/3,3 Qw Δpw l/h kPa Tw1/Tw2 = 80/60oC 832/878/900 1,16/1,28/1,34 761/803/824 0,99/1,09/1,14 691/729/747 0,83/0,91/0,95 619/654/670 0,68/0,75/0,78 547/578/592 0,54/0,6/0,63 Tw1/Tw2 = 60/40oC 464/508/521 0,43/0,51/0,53 386/424/436 0,31/0,37/0,39 289/329/341 0,19/0,23/0,25 167/173/174 0,07/0,08/0,08 137/141/142 0,05/0,05/0,05 Tp2 °C 27/26/25 29/28/28 32/31/31 35/34/34 37/37/36 16/15/15 18/18/17 20/19/20 21/20/21 25/24/24 To obtain operating parameters concerning other water temperatures, please contact Sales Office. ELiS B–W–150 2R Tp1 °C 0 5 10 15 20 0 5 10 15 20 V m3/h 3000/ 3200/ 3800 3000/ 3200/ 3800 PT kW 36,6/38,1/42,2 34,2/35,6/39,4 31,8/33,1/39,4 29,4/30,6/33,9 27,0/28,1/31,1 25,7/26,7/29,6 23,2/24,2/26,8 20,8/21,6/24,0 18,3/19,1/21,1 15,8/16,5/18,2 Qw Δpw l/h kPa Tw1/Tw2 = 90/70oC 1615/1680/1863 4,7/5,0/6,1 1509/1570/1740 4,1/4,4/5,4 1403/1460/1618 3,6/3,9/4,7 1297/1349/1495 3,1/3,4/4,1 1191/1239/1373 2,7/2,9/3,5 Tw1/Tw2 = 70/50oC 1125/1170/1296 2,6/2,8/3,3 1018/1058/1173 2,1/2,3/2,8 910/946/1049 1,7/1,9/2,3 801/833/924 1,4/1,5/1,8 691/719/797 1,1/1,1/1,4 Tp2 °C PT kW 36,0/35,0/33,0 38,5/38,0/35,5 41,0/40,5/38,5 43,5/43,0/41,0 46,0/45,5/44,0 31,2/32,5/36,0 28,8/29,9/33,2 26,3/27,4/30,4 23,9/24,9/27,5 21,5/22,3/24,7 25,5/24,5/23,0 28,0/27,5/26,0 30,5/30,0/28,5 33,0/32,5/31,5 35,5/35,0/34,0 20,1/20,9/23,2 17,6/18,3/20,3 15,1/15,7/17,4 12,4/13,0/14,4 9,66/10,1/11/3 Qw Δpw l/h kPa Tw1/Tw2 = 80/60oC 1370/1425/1580 3,6/3,8/4,6 1264/1314/1457 3,1/3,3/4,0 1157/1203/1334 2,6/2,8/3,4 1050/1092/1210 2,2/2,4/2,8 943/981/1086 1,8/1,9/2,3 Tw1/Tw2 = 60/40oC 876/911/1010 1,7/1,8/2,2 767/798/885 1,3/1,4/1,7 656/683/758 1,0/1,1/1,3 542/565/628 0,7/0,8/0,9 421/440/492 0,5/0,5/0,6 Tp2 °C 31,0/30,0/28,0 33,5/32,5/31,0 36,0/35,0/33,5 38.5/37,5/36,0 41,0/40,0/39,0 20,0/19,5/18,0 22,5/22,0/21,0 25,0/24,5/23,5 27,0/27,0/26,0 29,5/29,0/28,5 To obtain operating parameters concerning other water temperatures, please contact Sales Office. ELiS B–W–200 2R Tp1 °C 0 5 10 15 20 0 5 10 15 20 V m3/h 3800/ 4100/ 4900 3800/ 4100/ 4900 PT kW 48,4/50,7/57,2 45,3/47,5/53,5 42,2/44,2/49,9 39,1/41,0/46,2 36,0/37,7/42,5 34,5/36,2/40,8 31,4/32,9/37,1 28,2/29,5/33,3 25,0/26,2/29,5 21,8/22,8/25,7 Qw Δpw l/h kPa Tw1/Tw2 = 90/70oC 2135/2238/2524 8,98/9,79/12,2 1999/2095/2362 7,96/8,57/10,8 1862/1951/2200 6,99/7,62/9,49 1725/1808/2038 6,08/6,62/8,25 1588/1664/1876 5,23/5,69/7,09 Tw1/Tw2 = 70/50oC 1510/1582/1783 5,06/5,51/6,85 1372/1437/1620 4,25/4,63/5,75 1233/1292/1456 3,51/3,82/4,74 1094/1146/999 2,83/3,07/3,81 953/999/1125 2,21/2,4/2,97 Tp2 °C PT kW 38/37/34 40/39/37 43/42/39 45/44/42 48/47/45 41,5/43,5/49,0 38,3/40,2/45,3 35,2/36,9/41,6 32,1/33,6/37,9 28,9/30,3/34,2 27/26/24 29/29/27 32/31/30 34/34/32 37/36/35 27,4/28,8/32,4 24,2/25,4/28,6 21,0/22,0/24,8 17,7/18,6/21,0 14,4/15,1/17,0 Qw Δpw l/h kPa Tw1/Tw2 = 80/60oC 1822/1910/2153 6,91/7,52/9,37 1685/1766/1991 5,99/6,52/8,12 1547/1622/1828 5,13/5,58/6,95 1409/1477/1664 4,33/4,71/5,86 1271/1332/1501 3,59/3,9/4,85 Tw1/Tw2 = 60/40oC 1196/1523/1413 3,44/3,74/4,64 1057/1107/1248 2,75/2,99/3,71 916/960/1082 2,13/2,32/2,87 773/810/913 1,57/1,71/2,12 626/657/741 1,08/1,18/1,46 Tp2 °C 32/31/29 35/34/32 37/36/34 40/39/37 42/41/40 21/21/19 24/23/22 26/26/25 29/28/27 31/31/30 To obtain operating parameters concerning other water temperatures, please contact Sales Office. PT –heating capacity Tp1 –inlet air temperature Tp2 –outlet air temperature Tw1 –inlet water temperature www.flowair.com Tw2 –outlet water temperature Qw –water stream flow in the heat exchanger Δpw–water pressure drop in the heat exchanger 17 Moce Heating capacities ELiS B with electric heaters Power supply [V/Hz] Rated current of unit(1) [A] Heating capacity(1) [kW] Air temperature rise for curtain (ΔT)(1) [°C] (1) 1 step B-E-100 2 step 3 step 1 step 10,2 7,1 12 10,5 7,3 12 11 7,5 11 15,9 11 13 B-E-150 2 step 3x400/50 16,1 11,2 12 3 step 1 step B-E-200 2 step 3 step 16,6 11,5 12 21,5 14,9 14 21,8 15,1 14 22,4 15,5 13 At inlet air temperature 10oC. 18 www.flowair.com www.flowair.com 19 2017 v.1 www.flowair.com
© Copyright 2026 Paperzz