Packaged Heat Pump Water-to-Wate Liquid Chillers Models 27,1 à 570.2 Cooling capacities 27 à 606 kW Heating capacities 35 à 817 kW TECHNICAL CATALOGUE EWMH Thank you for trust in Hitecsa Product. From our company we are offering to the market, for more than 30 years, an extended range of specialized units for air conditioning and cooling installations. Our approach is based in efficiency, flexibility, manageability and practical solutions. It has built a hallmark of our product catalogue. The versatility of our factory allows us to contribute solutions almost customitzables in each project, searching a solution for every problem that arises in design and implementation of air conditioning installations. From Hiplus Aire Acondicionado’s team, once more thank you very much. EWMH GENERAL CHARACTERISTICS ........................................................................................................... 5 PHYSICAL DATA.................................................................................................................................... 8 ACOUSTICAL DATA ............................................................................................................................ 20 ELECTRICAL DALA ............................................................................................................................. 21 MICROPROCESSOR CONTROL SYSTEM ....................................................................................... 21 ACCESSORIES – PARTIAL HEAT RECOVERY SYSTEM................................................................ 22 ACCESSORIES - BRINE KIT.............................................................................................................. 22 DIMENSIONS EWMH 27.1 - 30.1 - 33.1 ............................................................................................. 24 DIMENSIONS EWMH 39.1 .................................................................................................................. 25 DIMENSIONS EWMH 40.1 – 48.1 – 54.1 – 60.1 – 70.1 – 90.1 – 120.1 ............................................ 26 DIMENSIONS EWMH 40.2 – 48.2 – 54.2 – 60.2 – 70.2 – 90.2 – 120.2 ............................................ 27 DIMENSIONS EWMH 150.1 ................................................................................................................ 28 DIMENSIONS EWMH 150.2 ................................................................................................................ 29 DIMENSIONS EWMH 170.2 ................................................................................................................ 30 DIMENSIONS EWMH 190.2 – 240.2 ................................................................................................... 31 DIMENSIONS EWMH 200.1 ................................................................................................................ 32 DIMENSIONS EWMH 200.2 ................................................................................................................ 33 DIMENSIONS EWMH 220.1 – 290.1 ................................................................................................... 34 DIMENSIONS EWMH 300.2 ................................................................................................................ 35 DIMENSIONS EWMH 340.2 – 380.2 ................................................................................................... 36 DIMENSIONS EWMH 460.2 – 570.2 ................................................................................................... 37 3 01.16 207573 Rev101 4 01.16 207573 Rev101 EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS GENERAL CHARACTERISTICS Description Packaged heat pump water/water liquid chiller for chilled water production in summer time and hot water production in winter time (inversión on refrigerant circuit). The machines are made for indoor installation. Machines supply fully assembled with refrigerant charge and control systems. The installation requires electrical and hydraulic connections only allowinghigh costs and time reduction. Final assembly on all machines before shipment including running test, reading and monitoring of operating parameters, alarms simulation and visual check. Design, assembly and test as per the Company Quality Assurance program in full compliance with ISO 9001:2008. Environmental Management System Certification according to ISO 14001:2004. The machines are in full compliance with European Directive 2006/42EC, 2006/95EC, 2004/108EC, 97/23EC and subsequent amendments. Framework Base, self supporting frame and panelling in steel plate with protective surfaces treatment in compliance with UNI ISO 9227/ASTMB117 and ISO 7253, and painted with epoxy powders. Colour: RAL 9002. Compressors Orbiting spiral (SCROLL) hermetic compressors with spiral profile optimized for R410A refrigerant. ON / OFF capacity control (0 / 100% each compressor). 2-pole 3-phase electric motor with direct on line starting. Phase sequence electronic relay. Crankcase heater. Electric motor thermal protection via internal winding temperatura sensors. Rubber supports. Plant side heat exchanger Copper brazed plate type with cover plates, plates and connections in AISI 316 stainless steel : With single refrigerant circuit for "1" version machines. With double refrigerant circuit for "2" version machines. Anticondensate insulation made of polyurethane. Temperature sensors on water inlet and outlet. Differential water pressure switch for water flow control. Exhaustion side heat exchanger Copper brazed plate type with cover plates, plates and connections in AISI 316 stainless steel. Temperature sensor on water outlet. 0÷10V proportional signal to manage the 2-way motorized valve for the condensing control (summer working mode) and evaporating control (winter working mode). Electronic expansion valve. The valve allows high performance and system efficiency thanks to a timely and accurate response to changes in temperature and pressure. The expansion valve is equipped with energy reserve to allow the closure of the valve in the event of lack of power supply. Sight glass. Filter dryer on liquid line. Service valves on liquid line and gas discharge. Safety valve on low pressure side. Pressure transducers with indication, control and protection functions, on low and high refrigerant pressure. High pressure safety switch with manual reset. Oil drainage and oil recovery systems. Refrigerant circuit with copper tubing with anticondensate insulation of the suction line. Plastic capillary hoses for pressure sensors connection. R410A refrigerant charge. Electrical pannel In accordance with EN60204-1 norms, suitable for indoor installation complete with: Main switch with door lock safety. Magnetothermic switch or fuses for each compressor. Contactors for each load. Transformer for auxiliary circuit and microprocessor supply. Panel with machine controls. Summer / Winter working mode selector. Power supply 400/3/50. Control system MP.COM microprocessor system with graphic display for control andmonitor of operating and alarms status. The system includes: Voltage free contact for remote general alarm. Main components hour-meter. Clock card for alarms date and time displaying and storing. Non-volatile "Flash" memory for data storage. Menu with protection password. LAN connection. Hydraulic connection The heat exchangers’ threaded hydraulic connections are available up to a diameter of 3" included, and correspond to ISO 228/1 – G M. The pipes’ threaded hydraulic connections are available up to a diameter of 3" included, and correspond to ISO 7/1 – R. The hydraulic connections with flange (FL) are not supplied with counter flange. The hydraulic connections with grooved end are not supplied with flexible joint (optional accessory). Refrigerant circuit Components for each refrigerant circuit : Reversing valve for refrigeration cycle inversion. 5 01.16 207573 Rev 101 EWNL PACKAGED HEAT PUMP WATER-TO-WATE LIQUID CHILLERS Accessories The descriptions of these additional components can be found in Chapter OPTIONAL ACCESSORIES. Partial heat recovery system. BRINE kit for chilled water production down to –12 °C. Warning: With BRINE Kit it is mandatory to use antifreeze mixture. Refer to the paragraph ANTIFREEZE SOLUTION. The use of antifreeze mixtures causes a reduction of the machine performance. Please refer to the selection program to obtain the effective performance. Other Accessories 2 way motorized water valve kit for condensing control (summer working mode) and evaporating control (winter working mode), supplied not installed. Hydraulic connections of the evaporator : Flexible joint with adapter pipe (solder type). Flexible joint with adapter for flange connection (FL). The counterflange is not supplied. Rubber supports - not installed. Power factor capacitor for motor compressor - cosj 0.9 excluded 27.1 /30.1 / 33.1 / 39.1 / 40.1 / 40.2 models. Ambient temperature sensor. The ambient temperature sensor requiresthe installation of "Additional module" and "Driver for additional module" optional accessories. MP.COM microprocessor control accessories: Remote terminal. Serial port RCcom, MBUS/JBUS. Serial port LON. Serial port BACnet for Ethernet – SNMP – TCP/IP. Serial port BACnet for MS/TP. Serial port for GSM modem. Data logger for the memorization of the intervened alarms. Additional module with the following inputs / outputs : INPUTS : External alarm 1. External alarm 2. Line current indication. Line voltage indication/compensation. Ambient air temperature. OUTPUTS : External alarm 1. External alarm 2. General alarm 2. General alarm 3. Driver for the additional module. Warning : It is mandatory to install a water filter on evaporator water inlet (not supplied with the machine). We reserve the right to accept the matching of the optional installed on the unit. Operating Limits in Cooling/Heating mode Operating limits diagram according to the evaporator water outlet temperature and condenser water outlet temperature. The values are indicative. The working temperatures are influenced by a series of variables as working conditions, thermal load, active capacity steps and set of microprocessor control. 6 01.16 2075703 Rev 101 EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS Partial Heat Recoveru Working limits for hot water production from partial heat reclaim system. The system is not regulated and the heating capacity which is supplied depends on the machine working conditions. 40÷75 °C hot water outlet temperature range. 5÷15 °C Δt range between water inlet/outlet. Antifreeze Mixtures Antifreeze mixtures have to be used when the machine working conditions foresee the chilled outlet liquid temperature lower than 5 °C. Propylene Glycol Chilled outlet liquid temp. from the machine Percentage in weight of the mixture ºc 4 2 1 -2 -4 -6 -9 -12 % 5 10 15 20 25 30 35 40 Ethylene Glycol Chilled outlet liquid temp. from the machine Percentage in weight of the mixture ºc 4 2 0 -4 -7 -9 -10 -13 % 5 10 15 20 25 30 35 40 Warning : The values are referred to machine working temperature and not to freezing temperature of the used liquid. The use of antifreeze mixtures causes a reduction of the machine performance. Please refer to the selection program to obtain the effective performance. Storing temperature If the machine is not installed on receipt and is stored for a long time, store it in a protected place, at temperatures rang ing between -30 °C and 50 °C inabsence of superficial condensation and direct sun light. 7 01.16 207573 Rev 101 PHYSICAL DATA SIZES EWMH 27.1 30.1 33.1 39.1 40.1 40.2 SUMMER WORKING MODE (1) Cooling capacity kW 26,8 30,3 33,7 37,4 42,3 43,8 Compressor power input kW 6,3 7,1 8,1 10,0 11,3 11,3 A 12,6 13,5 15,6 20,5 22,4 22,5 m /h 3 4,6 5,2 5,8 6,4 7,3 7,5 kPa 55 56 50 37 46 28 m /h 3 5,7 6,5 7,2 8,6 9,3 9,5 kPa 69 63 64 47 57 38 Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop WINTER WORKING MODE (2) Heating capacity kW 34,8 39,3 43,8 50,2 57,6 59,2 Compressor power input kW 8,1 9,0 10,3 12,5 14,3 14,4 A 15,0 16,1 18,5 23,5 26,4 26,5 m /h 3 4,6 5,2 5,8 6,4 7,3 7,5 kPa 42 42 37 25 30 20 3 m /h 4,6 5,2 5,8 6,5 7,5 7,7 kPa 47 48 42 31 38 22 Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop PARTIAL HEAT RECOVERY (3) Heating capacity kW 4,2 4,7 5,2 5,9 6,8 - Water flow rate m /h 3 0,7 0,8 0,9 1,0 1,2 - Pressure drop kPa 6,1 7,9 9,6 4,1 5,4 - COMPRESSSOR Type Scroll Number 1 Maximum current A 22 25 31 34 42 42 Starting current A 118 118 140 173 132 132 Capacity steps 1 PLANT WATER EXCHANGER Quantity 1 Water volume Max water flow rate l 2,8 2,8 2,8 3,1 3,1 3,6 3 6,4 7,3 8,1 9,0 10,2 10,5 m /h EXHAUST WATER EXCHANGER Quantity 1 Water volume Max water flow rate l 2,8 2,8 2,8 3,1 3,1 3,6 3 8,0 9,1 10,1 11,5 13,0 13,4 m /h PARTIAL HEAT RECOVERY EXCHANGER Quantity 1 Water volume Max water flow rate l 0,4 0,4 0,4 0,6 0,6 m /h 3 1,0 1,1 1,3 1,4 1,6 Kg 2,9 2,9 3,0 3,9 4,2 5,0 REFRIGERANT Type R410A Total refrigerant charge Gas circuit n 1 POWER SUPPLY V/Ph/H 400/3/50 z ENERGY EFFICIENCY INDEXES 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 Kw/kw 4,24 4,27 4,17 3,76 3,74 3,88 4,31 4,35 4,25 4,02 4,03 4,11 IPLV- ARI Std 550/590 5,87 5,84 5,86 6,02 5,20 6,14 ESEER- Eurovent STD 6,24 6,21 6,23 6,40 5,52 6,53 Power supply EER COP Kw/kw EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS SOUND LEVEL Sound pressure level [Lp] (4) dB(A) 50,0 51,0 52,0 53,0 53,0 53,0 Sound power level [Lw] (5) dB(A) 65,4 66.4 57,4 68,8 68,9 68,9 1200 DIMENSIONS & WEIGHT Lenght mm 1000 1000 1000 1000 1200 Widht mm 650 650 650 650 750 750 Height mm 1400 1400 1400 1400 1700 1700 Kg 263 266 275 288 445 455 Ø 1 1/2’’ 1 1/2’’ 1 1/2’’ 1 1/2’’ 2’’ 2’’ Ø mm - - - - - - Ø 1’’ 1’’ 1’’ 1’’ 1’’ - Net weight HYDRAULIC CONNECTIONS Plant/Exhaust exchanger Inlet/outlet – ISO228/1-G M Plant/Exhaust exchanger Inlet/outlet – OD Partial heat recovery Inlet/outlet – ISO228/1-G M (1) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C. (2) Gross value - Referred to hot water outlet temperature at 45 °C and chilled water temperature 15/10 °C. (3) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C and recovery hot water temperature 40/45 °C. (4) Average sound pressure level [Lpm] 1m far according to ISO EN 3744. (5) Sound power level [Lw] according to ISO EN 9614 - 2. 9 01.16 207573 Rev 101 SIZES EWMH 48.1 48.2 54.1 54.2 60.1 60.2 SUMMER WORKING MODE (1) Cooling capacity kW 51,7 50,5 56,9 57,3 62,5 63,7 Compressor power input kW 13,1 12,7 14,9 14,5 16,5 16,2 A 25,9 25,5 27,8 27,2 31,8 31,2 m /h 3 8,9 8,7 9,8 9,8 10,7 10,9 kPa 47 29 50 28 43 28 m /h 3 11,2 11,0 12,4 12,4 13,7 13,8 kPa 57 38 60 37 51 36 Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop WINTER WORKING MODE (2) Heating capacity kW 69,3 58,0 76,4 76,6 84,0 84,6 Compressor power input kW 16,8 16,4 19,1 18,6 21,1 20,6 A 30,9 30,4 33,7 32,9 37,9 37,3 3 m /h 8,9 8,7 9,8 9,8 10,7 10,9 kPa 31 20 32 20 27 20 3 m /h 9,0 8,9 9,9 10,0 10,8 11,0 kPa 38 23 40 22 35 22 Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop PARTIAL HEAT RECOVERY (3) Heating capacity kW 8,2 - 8,9 - 9,8 - Water flow rate m /h 3 1,4 - 1,5 - 1,7 - Pressure drop kPa 8,0 - 6,2 - 7,4 - COMPRESSSOR Type Scroll Number 2 Maximum current A 44 44 50 50 62 62 Starting current A 140 140 143 143 171 171 Capacity steps 2 PLANT WATER EXCHANGER Quantity 1 Water volume Max water flow rate l 3,1 4,2 3,9 4,2 3,9 4,2 3 12,4 12,1 13,7 13,8 15,0 15,3 m /h EXHAUST WATER EXCHANGER Quantity 1 Water volume Max water flow rate l 3,1 4,2 3,9 4,2 3,9 4,2 3 15,7 15,4 17,4 17,4 19,2 19,3 m /h PARTIAL HEAT RECOVERY EXCHANGER Quantity 1 - 1 - 1 - l 0,6 - 0,8 - 0,8 - m /h 3 2,0 - 2,2 - 2,4 - Kg 4,3 5,7 5,7 5,7 5,8 5,7 n 1 2 1 2 1 2 POWER SUPPLY V/Ph/H 400/3/50 z ENERGY EFFICIENCY INDEXES 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 Kw/kw 3,95 3,98 3,82 3,95 3,79 3,93 4,13 4,15 4,00 4,12 3,98 4,11 IPLV- ARI Std 550/590 5,46 6,43 5,38 6,15 5,09 5,79 ESEER- Eurovent STD 5,80 6,84 5,72 6,54 5,41 6,15 Water volume Max water flow rate REFRIGERANT Type R410A Total refrigerant charge Gas circuit Power supply EER COP Kw/kw EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS SOUND LEVEL Sound pressure level [Lp] (4) dB(A) 53,0 53,0 54,0 54,0 55,0 55,0 Sound power level [Lw] (5) dB(A) 68,9 68,9 69,9 69,9 70,9 70,9 1200 DIMENSIONS & WEIGHT Lenght mm 1200 1200 1200 1200 1200 Widht mm 750 750 750 750 750 750 Height mm 1700 1700 1700 1700 1700 1700 Kg 455 470 465 480 470 495 Ø 2’’ 2’’ 2’’ 2’’ 2’’ 2’’ Ø mm - - - - - - Ø 1’’ - 1’’ - 1’’ - Net weight HYDRAULIC CONNECTIONS Plant/Exhaust exchanger Inlet/outlet – ISO228/1-G M Plant/Exhaust exchanger Inlet/outlet – OD Partial heat recovery Inlet/outlet – ISO228/1-G M (1) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C. (2) Gross value - Referred to hot water outlet temperature at 45 °C and chilled water temperature 15/10 °C. (3) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C and recovery hot water temperature 40/45 °C. (4) Average sound pressure level [Lpm] 1m far according to ISO EN 3744. (5) Sound power level [Lw] according to ISO EN 9614 - 2. 11 01.16 207573 Rev 101 SIZES EWMH 70.1 70.2 90.1 90.2 120.1 120.2 SUMMER WORKING MODE (1) Cooling capacity kW 84,7 74,8 96,9 98,2 122,0 119,0 Compressor power input kW 20,1 19,6 25,7 25,1 32,6 31,9 A 41,1 40,6 47,5 46,7 60,0 59,3 m /h 3 14,5 12,8 16,6 16,8 20,9 20,5 kPa 50 28 46 29 48 38 3 m /h 18,2 16,4 21,2 21,3 26,7 26,2 kPa 60 37 52 36 53 47 Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop WINTER WORKING MODE (2) Heating capacity kW 101,0 101,0 132,0 132,0 165,0 164,0 Compressor power input kW 25,1 24,8 32,5 31,7 40,9 40,3 A 47,1 46,7 55,6 54,5 69,3 68,5 3 m /h 14,5 12,8 16,6 16,8 20,9 20,5 kPa 40 19 27 19 28 24 3 m /h 13,1 13,1 17,1 17,3 21,4 21,2 kPa 41 23 37 23 39 31 Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop PARTIAL HEAT RECOVERY (3) Heating capacity kW 11,9 - 15,5 - 19,4 - Water flow rate m /h 3 2,0 - 2,7 - 3,3 - Pressure drop kPa 6,4 - 6,3 - 6,9 - COMPRESSSORS Type Scroll Number 2 Maximum current A 68 68 80 80 97 97 Starting current A 207 207 265 265 321 321 Capacity steps 2 PLANT WATER EXCHANGER Quantity 1 Water volume Max water flow rate l 4,7 6,4 5,8 6,7 7,2 8,3 3 20,3 17,9 23,2 23,5 29,3 28,7 m /h EXHAUST WATER EXCHANGER Quantity 1 Water volume Max water flow rate l 4,7 6,4 5,8 6,7 7,2 8,3 3 25,5 23,0 29,7 29,8 37,4 36,7 m /h PARTIAL HEAT RECOVERY EXCHANGER Quantity 1 - 1 - 1 - l 1,0 - 1,7 - 2,1 - m /h 3 2,9 - 3,7 - 4,7 - Kg 6,6 8,1 8,7 10,4 10,7 12,7 n 1 2 1 2 1 2 POWER SUPPLY V/Ph/H 400/3/50 z ENERGY EFFICIENCY INDEXES 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 Kw/kw 4,21 3,82 3,77 3,91 3,74 3,73 4,02 4,07 4,06 4,16 4,03 4,07 IPLV- ARI Std 550/590 5,45 6,30 5,20 5,96 5,13 5,99 ESEER- Eurovent STD 5,79 6,70 5,52 6,34 5,46 6,37 Water volume Max water flow rate REFRIGERANT Type R410A Total refrigerant charge Gas circuit Power supply EER COP Kw/kw EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS SOUND LEVEL Sound pressure level [Lp] (4) dB(A) 56,0 56,0 61,0 61,0 64,0 64,0 Sound power level [Lw] (5) dB(A) 71,9 71,9 76,9 76,9 80,1 80,1 1200 DIMENSIONS & WEIGHT Lenght mm 1200 1200 1200 1200 1200 Widht mm 750 750 750 750 750 750 Height mm 1700 1700 1700 1700 1700 1700 Kg 475 506 730 770 785 800 Ø 2’’ 2’’ - - - - Ø mm - - 73,1 73,1 73,1 73,1 Ø 1’’ - 1 1/4’’ - 1 1/4’’ - Net weight HYDRAULIC CONNECTIONS Plant/Exhaust exchanger Inlet/outlet – ISO228/1-G M Plant/Exhaust exchanger Inlet/outlet – OD Partial heat recovery Inlet/outlet – ISO228/1-G M (1) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C. (2) Gross value - Referred to hot water outlet temperature at 45 °C and chilled water temperature 15/10 °C. (3) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C and recovery hot water temperature 40/45 °C. (4) Average sound pressure level [Lpm] 1m far according to ISO EN 3744. (5) Sound power level [Lw] according to ISO EN 9614 - 2. 13 01.16 207573 Rev 101 SIZES EWMH 150.1 150.2 170.2 190.2 200.1 200.2 SUMMER WORKING MODE (1) Cooling capacity kW 158,0 154,0 194,0 206,0 207,0 220,0 Compressor power input kW 41,5 40,8 45,4 53,3 52,4 52,3 A 74,1 73,6 88,0 94,0 93,7 93,6 m /h 3 27,0 26,4 33,3 35,4 35,6 37,7 kPa 46 42 43 34 46 53 m /h 3 34,5 33,8 41,5 45,0 45,0 47,1 kPa 45 47 69 42 62 71 Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop WINTER WORKING MODE (2) Heating capacity kW 213,0 211,0 237,0 262,0 275,0 276,0 Compressor power input kW 52,0 51,6 58,1 69,7 64,7 64,2 A 87,8 87,3 105,0 113,0 110,0 109,0 3 m /h 27,0 26,4 33,3 35,4 35,6 37,7 kPa 24 24 58 76 37 43 3 m /h 27,8 27,4 30,9 33,2 36,2 36,4 kPa 38 33 45 28 43 44 Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop PARTIAL HEAT RECOVERY (3) Heating capacity kW 25,2 24,9 28,0 30,1 32,9 33,0 Water flow rate m /h 3 4,3 4,3 4,8 5,2 5,7 5,7 Pressure drop kPa 8,9 7,0 8,9 6,0 9,0 7,2 2 2 4 COMPRESSSORS Type Scroll Number 4 2 2 Maximum current A 131 131 148 160 164 164 Starting current A 375 375 333 345 466 466 2 2 4 4 2 2 l 8,7 12,3 12,3 20,3 20,7 20,3 3 37,8 37,0 46,6 49,6 49,8 52,8 Capacity steps PLANT WATER EXCHANGER Quantity 1 Water volume Max water flow rate m /h EXHAUST WATER EXCHANGER Quantity 1 Water volume Max water flow rate l 8,7 12,3 12,3 20,3 20,7 20,3 3 48,3 47,3 58,1 63,0 63,0 65,9 m /h PARTIAL HEAT RECOVERY EXCHANGER Quantity 1 2 2 2 1 2 l 4,0 2,0 3,4 3,4 5,3 3,4 m /h 3 6,1 6,0 6,7 7,3 7,9 8,0 Kg 12,4 17,0 17,8 23,9 22,4 22,8 n 1 2 2 2 1 2 POWER SUPPLY V/Ph/H 400/3/50 z ENERGY EFFICIENCY INDEXES 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 Kw/kw 3,81 3,77 4,27 3,86 3,95 4,21 4,10 4,09 4,08 3,76 4,25 4,30 IPLV- ARI Std 550/590 5,10 6,00 5,46 6,63 5,17 6,01 ESEER- Eurovent STD 5,42 6,38 5,62 6,43 5,50 6,39 Water volume Max water flow rate REFRIGERANT Type R410A Total refrigerant charge Gas circuit Power Supply EER COP Kw/kw EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS SOUND LEVEL Sound pressure level [Lp] (4) dB(A) 64,0 64,0 64,0 64,0 64,0 64,0 Sound power level [Lw] (5) dB(A) 81,0 81,0 81,0 81,0 81,0 81,0 DIMENSIONS & WEIGHT Lenght mm 1800 1800 1800 1800 1800 1800 Widht mm 1200 1200 1200 1200 1200 1200 Height mm 1740 1740 1740 1740 1740 1740 Net weight Kg 1035 1040 1140 1345 1100 135 Ø - - - - - - Ø mm 73,1 73,1 73,1 88,9 88,9 88,9 Ø 2’’ 2 x 1’’ 2 x 1 1/4’’ 2 x 1 1/4’’ 2’’ 2 x 1 1/4’’ HYDRAULIC CONNECTIONS Plant/Exhaust exchanger Inlet/outlet – ISO228/1-G M Plant/Exhaust exchanger Inlet/outlet – OD Partial heat recovery Inlet/outlet – ISO228/1-G M (1) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C. (2) Gross value - Referred to hot water outlet temperature at 45 °C and chilled water temperature 15/10 °C. (3) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C and recovery hot water temperature 40/45 °C. (4) Average sound pressure level [Lpm] 1m far according to ISO EN 3744. (5) Sound power level [Lw] according to ISO EN 9614 - 2. 15 01.16 207573 Rev 101 SIZES EWMH 220.1 240.2 290.1 300.2 kW kW A 262,0 61,1 110,0 250,0 63,9 119,0 328,0 78,3 140,0 313,0 81,8 147,0 m /h 3 45,0 42,9 56,3 53,7 kPa 52 61 49 70 m /h 3 55,9 54,3 70,3 68,4 kPa 68 81 60 89 kW kW A 332,0 76,8 130,0 335,0 80,4 137,0 413,0 96,4 164,0 420,0 103,0 175,0 m /h 3 45,0 42,9 56,3 53,7 kPa 46 44 40 48 3 m /h 43,9 43,8 54,5 54,6 kPa 49 50 46 57 kW 3 m /h kPa 25,2 4,3 8,9 24,9 4,3 7,0 28,0 4,8 8,9 30,1 5,2 6,0 A A 3 197 441 3 4 246 584 4 3 194 418 3 4 262 507 4 20,7 63,0 20,3 60,1 27,0 78,8 27,5 75,2 20,7 78,3 20,3 76,0 27,0 98,4 27,5 95,8 m /h 1 6,3 9,6 2 4,2 9,6 2 8,0 11,9 2 8,0 11,9 Kg n 23,1 1 24,7 2 30,3 1 31,6 2 400/3/50 400/3/50 400/3/50 400/3/50 4,29 4,32 6,37 6,77 3,91 4,17 5,53 5,87 4,19 4,28 6,23 6,62 3,83 4,08 5,65 6,01 65,8 82,8 67,0 84,1 65,8 82,8 67,0 84,1 1800 1200 1740 1310 1800 1200 1740 1570 1800 1200 1740 1390 1800 1200 1740 1615 SUMMER WORKING MODE (1) Cooling capacity Compressor power input Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop WINTER WORKING MODE (2) Heating capacity Compressor power input Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop PARTIAL HEAT RECOVERY (3) Heating capacity Water flow rate Pressure drop COMPRESSORS Type Number Maximum current Starting current Capacity steps Scroll PLANT WATER EXCHANGER Quantity Water volume Max water flow rate 1 l 3 m /h EXHAUST WATER EXCHANGER Quantity Water volume Max water flow rate 1 l 3 m /h PARTIAL HEAT RECOVERY EXCHANGER Quantity Water volume Max water flow rate l 3 REFRIGERANT Type Total refrigerant charge Gas circuit R410A POWER SUPPLY Power supply V/Ph/Hz EENERGY EFFICIENCY INDEXES EER Kw/kw COP Kw/kw IPLV- ARI Std 550/590 ESEER- Eurovent STD SOUND LEVEL Sound pressure level [Lp] (4) dB(A) Sound power level [Lw] (5) dB(A) DIMENSIONS & WEIGHT Lenght mm Widht mm Height mm Net weight Kg EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS HYDRAULIC CONNECTIONS Plant/Exhaust exchanger Inlet/outlet – ISO228/1-G M Plant/Exhaust exchanger Inlet/outlet – OD Partial heat recovery Inlet/outlet – ISO228/1-G M Ø - - - - Ø mm 88,9 88,9 88,9 88,9 Ø 2’’ 2 x 1 1/4’’ 2’’ 2 x 2’’ (1) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C. (2) Gross value - Referred to hot water outlet temperature at 45 °C and chilled water temperature 15/10 °C. (3) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C and recovery hot water temperature 40/45 °C. (4) Average sound pressure level [Lpm] 1m far according to ISO EN 3744. (5) Sound power level [Lw] according to ISO EN 9614 - 2. 17 01.16 207573 Rev 101 SIZES EWMH 340.2 380.2 460.2 570.2 kW kW A 364,0 93,4 168,0 405,0 104,0 187,0 482,0 121,0 219,0 606,0 158,0 282,0 m /h 3 62,6 69,5 82,7 104,0 kPa 70 64 63 82 m /h 3 79,3 88,2 105,0 132,0 kPa 86 74 64 83 kW kW A 488,0 116,0 197,0 539,0 129,0 220,0 646,0 130,0 260,0 817,0 196,0 333,0 m /h 3 62,6 69,5 82,7 104,0 kPa 46 40 34 44 3 m /h 63,9 70,5 88,9 107,0 kPa 57 53 52 69 kW 3 m /h kPa 57,9 10,0 11,8 63,9 11,0 8,5 80,6 13,9 9,6 96,9 16,7 8,7 A A 4 295 597 4 4 328 630 4 6 393 637 6 6 492 794 6 33,8 111,0 44,6 123,5 44,6 147,0 57,2 184,8 33,8 111,0 44,6 123,5 44,6 147,0 57,2 184,8 m /h 2 8,0 14,0 2 10,6 15,4 2 12,6 19,5 2 16,0 23,4 Kg n 31,1 2 48,1 2 49,5 2 62,4 2 400/3/50 400/3/50 400/3/50 400/3/50 3,90 4,21 5,75 6,12 3,89 4,18 5,66 6,02 3,98 4,97 6,00 6,38 3,84 4,17 5,93 6,31 67,0 84,5 67,0 84,5 68,8 86,3 68,8 86,3 1800 1800 1740 1710 1800 1800 1740 1796 1800 1800 1740 2270 1800 1800 1740 2365 SUMMER WORKING MODE (1) Cooling capacity Compressor power input Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop WINTER WORKING MODE (2) Heating capacity Compressor power input Compressor operating current Plant water exchanger water flow rate Plant water exchanger pressure drop Exhaust water exchanger water flow rate Exhaust water exchanger pressure drop PARTIAL HEAT RECOVERY (3) Heating capacity Water flow rate Pressure drop COMPRESSSORS Quantity Water volume Max water flow rate Quantity Water volume Scroll PLANT WATER EXHANGER Quantity Water volume Max water flow rate 1 l 3 m /h EXHAUST WATER EXHANGER Quantity Water volume Max water flow rate 1 l 3 m /h PARTIAL HEAT RECOVERY EXCHANGER Quantity Water volume Max water flow rate l 3 REFRIGERANT Type Total refrigerant charge Gas circuit R410A POWER SUPPLY Power supply V/Ph/Hz ENERGY EFFICIENTY INDEXES EER Kw/kw COP Kw/kw IPLV- ARI Std 550/590 ESEER- Eurovent STD SOUND LEVEL Sound pressure level [Lp] (4) dB(A) Sound power level [Lw] (5) dB(A) DIMENSIONS & WEIGHT Lenght mm Widht mm Height mm Net weight Kg EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS HYDRAULIC CONNECTIONS Plant/Exhaust exchanger Inlet/outlet – ISO228/1-G M Plant/Exhaust exchanger Inlet/outlet – OD Partial heat recovery Inlet/outlet – ISO228/1-G M Ø - - - - Ø mm 88,9 88,9 88,9 88,9 Ø 2 x 2’’ 2 x 2’’ 2 x 2’’ 2 x 2’’ (1) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C. (2) Gross value - Referred to hot water outlet temperature at 45 °C and chilled water temperature 15/10 °C. (3) Gross value - Referred to chilled water temperature 12/7 °C; condenser water temperature 30/35 °C and recovery hot water temperature 40/45 °C. (4) Average sound pressure level [Lpm] 1m far according to ISO EN 3744. (5) Sound power level [Lw] according to ISO EN 9614 - 2. 19 01.16 207573 Rev 101 ACOUSTICAL DATA SIZES EWMH Sound power level [Lw] (1) dB(A) 27.1 30.1 33.1 39.1 40.1 40.2 65,4 66,4 67,4 68,8 68,9 68,9 AVERAGE SOUND PRESSURE LEVEL [Lpm] at 1 m (2) dB(A) 50,0 51,0 52,0 53,0 53,0 53,0 [Lpm] at 5 m (2) dB(A) 39,5 40,5 41,5 42,7 42,8 42,8 [Lpm] at 10 m (2) dB(A) 34,0 35,0 36,0 37,3 37,4 37,4 48.1 48.2 54.1 54.2 60.1 60.2 68,9 68,9 69,9 69,9 70,9 70,9 SIZES EWMH Sound power level [Lw] (1) dB(A) AVERAGE SOUND PRESSURE LEVEL [Lpm] at 1 m (2) dB(A) 53,0 53,0 54,0 54,0 55,0 55,0 [Lpm] at 5 m (2) dB(A) 42,8 42,8 43,8 43,8 44,8 44,8 [Lpm] at 10 m (2) dB(A) 37,4 37,4 38,4 38,4 39,4 39,4 70.1 70.2 90.1 90.2 120.1 120.2 71,9 71,9 76,9 76,9 80,1 80,1 SIZES EWMH Sound power level [Lw] (1) dB(A) AVERAGE SOUND PRESSURE LEVEL [Lpm] at 1 m (2) dB(A) 56,0 56,0 61,0 61,0 64,0 64,0 [Lpm] at 5 m (2) dB(A) 45,8 45,8 50,8 50,8 54,0 54,0 [Lpm] at 10 m (2) dB(A) 40,4 40,4 45,4 45,4 48,6 48,6 150.1 150.2 170.2 190.2 200.1 200.2 81,0 81,0 81,0 81,0 81,0 81,0 SIZES EWMH Sound power level [Lw] (1) dB(A) AVERAGE SOUND PRESSURE LEVEL [Lpm] at 1 m (2) dB(A) 64,0 64,0 64,0 64,0 64,0 64,0 [Lpm] at 5 m (2) dB(A) 54,6 54,6 54,6 54,6 54,6 54,6 [Lpm] at 10 m (2) dB(A) 49,4 49,4 49,4 49,4 49,4 49,4 220.1 240.2 290.1 300.2 340.2 380.2 82,8 84,1 82,8 84,1 84,5 84,5 SIZES EWMH Sound power level [Lw] (1) dB(A) AVERAGE SOUND PRESSURE LEVEL [Lpm] at 1 m (2) dB(A) 65,8 67,0 65,8 67,0 67,0 67,0 [Lpm] at 5 m (2) dB(A) 56,3 57,6 56,3 57,6 57,9 57,9 [Lpm] at 10 m (2) dB(A) 51,1 52,4 51,1 52,4 52,8 52,8 460.2 570.2 86,3 86,3 SIZES EWMH Sound power level [Lw] (1) dB(A) AVERAGE SOUND PRESSURE LEVEL [Lpm] at 1 m (2) dB(A) 68,8 68,8 [Lpm] at 5 m (2) dB(A) 59,7 59,7 [Lpm] at 10 m (2) dB(A) 54,5 54,5 (1) Sound power level [Lw] according to ISO EN 9614 - 2. (2) Average sound pressure level [Lpm] according to ISO EN 3744. EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS ELECTRICAL DALA MAXIMUM ELECTRIC ABSORPTION CALCULATION This chapter is showing the maximum electrical absorption calculation of machine, corresponding to extreme working conditions. The involved components are the following: Compressors electric motors. The electrical data of the various components are indicated in the relativetechnical data sheets. MICROPROCESSOR CONTROL SYSTEM The MP.COM microprocessor control system is equipped with 8 keys terminal and back lighted graphic display on which all infor mation in different languages or easily identifiable symbols are displayed. The system disposes of a "flash" memory that preserves the information even in absence of power supply. 21 01.16 207573 Rev 101 REMOTE CONTROLS/ALARMS INPUTS 1 External enabling * 2 Cooling xK1 and cooling xK2 set-point changeover * OUPUTS 1 General alarm 1 ** * Remote controls/alarms ** Voltage free controls/alarms Important: To obtain more information, please refer to the software catalogue of the unit. ACCESSORIES – PARTIAL HEAT RECOVERY SYSTEM The partial heat recovery exchangers are installed on every refrigerant circuit of the machine before the main condenser. The system is not regulated and the control is ON-OFF type. The heat recovery system’s operation is subject to the supply demand of cooling capacity. The system includes: Copper brazed plate type heat exchanger with cover plates, plates and connections in AISI 316 stainless steel. Anticondensate insulation made of polyurethane. Hydraulic piping. In the machines with two refrigerant circuits the parallel connection of the hydraulic circuit is at Customer care. The heating capacity which is supplied depends on the kind of refrigerant gas which is used and working temperatures. The heat exchangers can produce hot water up to the maximum temperatura of 70÷75 °C and according to the working conditions of the unit. SCHEMA DE PRINCIPE DE LA RECUPERATION DE CHALEUR PARTIELLE COMPONENTS COM RU Compressor SC Partial heat recovery exchanger Valve ACCESSORIES - BRINE KIT The accessory allows the production of glycol solution leaving the machine down to a temperature of -12 °C. The kit includes: EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS Set of the working parameters. Warning : With BRINE Kit it is mandatory to use antifreeze mixture. Refer to the paragraph ANTIFREEZE SOLUTION. The use of antifreeze mixtures causes a reduction of the machine performance. Please refer to the selection program to obtain the effective performance. 23 01.16 207573 Rev 101 DIMENSIONS EWMH 27.1 - 30.1 - 33.1 Connections 1 Condenser inlet R 1"1/4 2 Condenser outlet R 1"1/4 3 Power supply 4 Water inlet R 1"1/4 5 Water outlet R 1"1/4 6 20% heat recovery inlet R 1" (optional) 7 20% heat recovery outlet R 1" (optional) EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS DIMENSIONS EWMH 39.1 Connections 1 Condenser inlet R 2" 2 Condenser outlet R 2" 3 Power supply 4 Water inlet R 2" 5 Water outlet R 2" 6 20% heat recovery inlet R 1" (optional) 7 20% heat recovery outlet R 1" (optional) 25 01.16 207573 Rev 101 DIMENSIONS EWMH 40.1 – 48.1 – 54.1 – 60.1 – 70.1 – 90.1 – 120.1 Connections 1 Condenser inlet R 2" (models 40.1 à 70.1), Victaulic 2"1/2 Ø extern 73 mm (models 90.1 & 120.1) 2 Condenser outlet R 2" (models 40.1 à 70.1), Victaulic 2"1/2 Ø extern 73 mm (models 90.1 & 120.1) 3 Power supply 4 Water inlet R 2" (modèles 40.1 à 70.1), Victaulic 2"1/2 Ø extern 73 mm (models 90.1 & 120.1) 5 Water outlet R 2" (modèles 40.1 à 70.1), Victaulic 2"1/2 Ø extern73 mm (models 90.1 & 120.1) 6 Heat recovery inlet 20% R 1"1/4 - Models 90.1 & 120.1 (option) 6A Heat recovery inlet 20% R 1" - Models 40.1 à 70.1 (option) 7 Heat recovery outlet 20% R 1"1/4 - Models 90.1 & 120.1 (option) 7A Heat recovery outlet 20% R 1" - Models 40.1 à 70.1 (option) EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS DIMENSIONS EWMH 40.2 – 48.2 – 54.2 – 60.2 – 70.2 – 90.2 – 120.2 Connections 1 Condenser inlet R 2" (models 40.2 to 70.2), Victaulic 2"1/2 OD 73 mm (models 90.2 & 120.2) 2 Condenser outlet R 2" (models 40.2 to 70.2), Victaulic 2"1/2 OD 73 mm (models 90.2 & 120.2) 3 Power supply 4 Water inlet R 2" (models 40.2 to 70.2), Victaulic 2"1/2 OD 73 mm (models 90.2 & 120.2) 5 Water outlet R 2" (models 40.2 to 70.2), Victaulic 2"1/2 OD 73 mm (models 90.2 & 120.2) 27 01.16 207573 Rev 101 DIMENSIONS EWMH 150.1 Connections 1 Condenser inlet Ø 2"1/2 Victaulic OD 73 mm 2 Condenser outlet Ø 2"1/2 Victaulic OD 73 mm 3 Power supply 4 Water inlet Ø 2"1/2 Victaulic OD 73 mm 5 Water outlet Ø 2"1/2 Victaulic OD 73 mm 6 20% heat recovery inlet R 2" (optional) 7 20% heat recovery outlet R 2" (optional) EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS DIMENSIONS EWMH 150.2 Connections 1 Condenser inlet Ø 2"1/2 Victaulic OD 73 mm 2 Condenser outlet Ø 2"1/2 Victaulic OD 73 mm 3 Power supply 4 Water inlet Ø 2"1/2 Victaulic OD 73 mm 5 Water outlet Ø 2"1/2 Victaulic OD 73 mm 6 20% heat recovery inlet R 2" (optional) 7 20% heat recovery outlet R 2" (optional) 29 01.16 207573 Rev 101 DIMENSIONS EWMH 170.2 Connections 1 Condenser inlet Ø 2"1/2 Victaulic OD 73 mm 2 Condenser outlet Ø 2"1/2 Victaulic OD 73 mm 3 Power supply 4 Water inlet Ø 2"1/2 Victaulic OD 73 mm 5 Water outlet Ø 2"1/2 Victaulic OD 73 mm 6 20% heat recovery inlet R 1"1/4 (optional) 7 20% heat recovery outlet R 1"1/4 (optional) EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS DIMENSIONS EWMH 190.2 – 240.2 Connections 1 Condenser inlet Ø 3" Victaulic OD 88.9 mm 2 Condenser outlet Ø 3" Victaulic OD 88.9 mm 3 Power supply 4 Water inlet Ø 3" Victaulic OD 88.9 mm 5 Water outlet Ø 3" Victaulic OD 88.9 mm 6 20% heat recovery inlet R 1"1/4 (optional) 7 20% heat recovery outlet R 1"1/4 (optional) 31 01.16 207573 Rev 101 DIMENSIONS EWMH 200.1 Connections 1 Condenser inlet Ø 3" Victaulic OD 88.9 mm 2 Condenser outlet Ø 3" Victaulic OD 88.9 mm 3 Power supply 4 Water inlet Ø 3" Victaulic OD 88.9 mm 5 Water outlet Ø 3" Victaulic OD 88.9 mm 6 20% heat recovery inlet R 2" (optional) 7 20% heat recovery outlet R 2" (optional) EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS DIMENSIONS EWMH 200.2 Connections 1 Condenser inlet Ø 3" Victaulic OD 88.9 mm 2 Condenser outlet Ø 3" Victaulic OD 88.9 mm 3 Power supply 4 Water inlet Ø 3" Victaulic OD 88.9 mm 5 Water outlet Ø 3" Victaulic OD 88.9 mm 6 20% heat recovery inlet R 1"1/4 (optional) 7 20% heat recovery outlet R 1"1/4 (optional) 33 01.16 207573 Rev 101 DIMENSIONS EWMH 220.1 – 290.1 Connections 1 Condenser inlet Ø 3" Victaulic OD 88.9 mm 2 Condenser outlet Ø 3" Victaulic OD 88.9 mm 3 Power supply 4 Water inlet Ø 3" Victaulic OD 88.9 mm 5 Water outlet Ø 3" Victaulic OD 88.9 mm 6 20% heat recovery inlet R 2" (optional) 7 20% heat recovery outlet R 2" (optional) EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS DIMENSIONS EWMH 300.2 Connections 1 Condenser inlet Ø 3" Victaulic OD 88.9 mm 2 Condenser outlet Ø 3" Victaulic OD 88.9 mm 3 Power supply 4 Water inlet Ø 3" Victaulic OD 88.9 mm 5 Water outlet Ø 3" Victaulic OD 88.9 mm 6 20% heat recovery inlet R 2" (optional) 7 20% heat recovery outlet R 2" (optional) 35 01.16 207573 Rev 101 DIMENSIONS EWMH 340.2 – 380.2 Connections 1 Condenser inlet Ø 3" Victaulic OD 88.9 mm 2 Condenser outlet Ø 3" Victaulic OD 88.9 mm 3 Power supply 4 Water inlet Ø 3" Victaulic OD 88.9 mm 5 Water outlet Ø 3" Victaulic OD 88.9 mm 6 20% heat recovery inlet R 2" (optional) 7 20% heat recovery outlet R 2" (optional) EWMH PACKAGED HEAT PUMP W ATER-TO-WATE LIQUID CHILLERS DIMENSIONS EWMH 460.2 – 570.2 Connections 1 Condenser inlet Ø 3" Victaulic OD 88.9 mm 2 Condenser outlet Ø 3" Victaulic OD 88.9 mm 3 Power supply 4 Water inlet Ø 3" Victaulic OD 88.9 mm 5 Water outlet Ø 3" Victaulic OD 88.9 mm 6 20% heat recovery inlet R 2" (optional) 7 20% heat recovery outlet R 2" (optional) 37 01.16 207573 Rev 101 HIPLUS AIRE ACONDICIONADO S.L. Masia Torrents, 2 Tel. +34 93 893 49 12 Fax. +34 93 893 96 15 08800 Vilanova i la Geltrú Barcelona, Spain www.hitecsa.com As part of our ongoing product improvement programme, the technical data and colours of our products are subject to change without prior notice.
© Copyright 2026 Paperzz