Model: 12 -Ton PURY-P144ZKMU-A (-BS) Job Name: Schedule Reference: Date: ACCESSORIES %UD]HGW\SH Ƒ BC Controller ........................ CMB-P104/105/106/108/1010/1013/1016NU-G1 Ƒ BC Controller Main ...................................... CMB-P108/1010/1013/16NU-GA1 Ƒ BC Controller Main ..................... CMB-P108/1010NU-+A1 / 16NU-HA1 Ƒ BC Controller Sub ......................... CMB-P104/108NU-GB1 / 1016NU-HB11 Ƒ Joint Adapter (Port Connector > 54,0000 Btu//h) ............................. CMY-R160C-J(1) □ T-Branch Joint (≤ 72,000 Btu/h) ............................................. CMY-Y102SS-G2 □ T-Branch Joint (73,000 - 144,000 Btu/h) ................................ CMY-Y102LS-G2 OUTDOOR VRF HEAT PUMP WITH HEAT RECOVERY SYSTEM UNIT OPTION □ Standard Model ...…........……....… PURY-P144ZKMU-A □ Seacoast (BS) Model …............ PURY-P144ZKMU-A-BS Specifications Unit Type Nominal Cooling Capacity (575V) Nominal Heating Capacity (575V) Operating Temperature Range External Dimensions (H x W x D) Net Weight External Finish (+Powder coating for - BS type) Electrical Power Requirements Minimum Circuit Ampacity (MCA) Maximum Overcurrent Protection (MOP) Piping Diameter (Brazed) (In. / mm) Max. Total Refrigerant Line Length Max. Refrigerant Line Length (Between ODU & IDU) Max. Control Wiring Length Indoor Unit Sound Pressure Levels Fan Type x Quantity Airflow Rat External Static Pressure Compressor Operating Range Compressor Type x Quantity Refrigerant Protection Devices AHRI Ratings (Ducted/Non-Ducted) Model Name PURY-P144ZKMU-A (-BS) Btu/h Btu/h 144,000 160,000 Cooling (Outdoor) Heating (Outdoor) In. (mm) Lbs. (kg) Voltage, Phase, Hertz A A Liquid (High Pressure) Gas (Low Pressure) Ft. Ft. 23~115° F (-5~46° C) DB -4~60° F (-20~15.5° C) WB 64-31/32 x 68-29/32 x 29-5/32 (1,650 x 1,750 x 740) 761 (345) Pre-coated galvanized steel sheet - MUNSELL 5Y 8/1 or similar 575V, 3-Phase, 60Hz 23 35 7/8 (22.2) 1-1/8 (28.58) 1,969 541 Ft. Total Capacity 1,640 50~150% of outdoor unit capacity Model / Quantity dB(A) P06~P96/1~30 61.0 CFM In. WG High Pressure Inverter Circuit (Comp. / Fan) Fan Motor EER IEER COP SCHE Heat Exchanger Propeller fan x 2 11,300 Selectable; 0, 0.12 or 0.24"WG; factory set to 0"W.G. 15% to 100% Inverter scroll hermetic compressor R410A x 26 lbs + 1 oz (11.8 kg) High pressure sensor, High pressure switch at 4.15 MPa (601 psi) Over-current protection Thermal switch TBD TBD TBD TBD Salt resistant cross fin & FRSSHU tube Notes: Specifications are subject to change without notice. © 2015 Mitsubishi Electric Sales Canada Inc. Page 1 of 2 Form # SB_PURY-P144ZKMU-A(-BS)_201606 air 57 (2-1/4) 533(21) ( Service valve Bottom view ( 57 (2-1/4) A 19.5 (13/16) Service panel 2 8 1 80 (3-3/16) 7 3 150(5-15/16) Bottom view 795(31-5/16) (Mounting pitch) Front view 58(2-5/16) 140(5-9/16) 795(31-5/16) (Mounting pitch) 6 516(20-3/8) 561(22-1/8) 526(20-3/4) 75(3) 541(21-5/16) 562(22-3/16) ø25.4 (1) ø28.58 Brazed (1-1/8) *1 2×3-14(9/16)×20(13/16) Oval hole <Sling hole> 80 (3-3/16) ø28.58 (1-1/8) ø28.58 (1-1/8) 8 7 6 (1-3/8) ø43.7 or ø22.2 Knockout hole (2-1/2) ø62.7 or ø34.5 Knockout hole 150 × 94 Knockout hole (5-15/16) (3-3/4) (1-3/4) (7/8) For wires ø65 Knockout hole Bottom through hole (2-9/16) ø52 Knockout hole Bottom through hole (2-1/16) ø34 Knockout hole For transmission cables Front through hole (1-3/8) Front through hole Front through hole 4 5 Bottom through hole 3 Front through hole ø45 Knockout hole (Uses when twinning kit (optional parts) (1-13/16) is mounted.) For pipes 2 Specifications 140 × 77 Knockout hole (5-9/16)(3-1/16) Front through hole Usage 1 NO. *1 Use the included connecting pipe and connect to the refrigerant service valve piping. PURY-P168ZSKMU ø25.4 (1) ø28.58 Brazed (1-1/8) *1 (7/8) *1 ø22.2 Brazed (7/8) *1 ø28.58 (1-1/8) Low pressure Service valve High pressure PURY-P144ZKMU ø22.2 Brazed (1-1/8) *1 Low pressure ø25.4 (1) (3/4) *1 High pressure PURY-P120ZKMU ø19.05 Brazed ø28.58 Brazed Model Refrigerant pipe Diameter Note1.Please refer to the next page for information regarding necessary spacing around the unit and foundation work. 2.At brazing of pipes,wrap the refrigerant service valve with wet cloth and keep the temperature of refrigerant service valve under 120°C(248 °F). Connecting pipe specifications 2×2-80(3-3/16)×35(1-7/16) Oval hole Fan box Service panel air air 5 Top view 19.5 (13/16) Intake 4 49(1-15/16) 831(32-3/4) 1750(68-15/16) 831(32-3/4) 740(29-3/16) Intake Control box Refrigerant service valve <Low pressure> Left side view 20 20 (13/16) (13/16) 586(23-1/8) Discharge air A Service valve Front view 140 (5-9/16) Refrigerant service valve <High pressure> 327(12-7/8) (5-3/4)146 121 (4-13/16) Intake 54(2-3/16) (23-5/8) =(5-15/16)×4 (2-13/16) 70 600=150×4 150 (5-15/16) (8-9/16) 217 (5-3/4) 145 196 (7-3/4) 1650(65) 2×7-ø4.6(3/16) Hole (Make hole at the plastic fan guard for snow hood attachment) <Snow hood attachment hole> /8) 77 (3-1/16) 89 (3-9/16) 84 (3-5/16) 94 (3-3/4) 303 (11-15/16) 29.5 (1-3/16) (26-13/16) 681(678~684) (26-3/4~26-15/16) (Mounting pitch) (740)(29-3/16) Page 2 of 2 29.5 (1-3/16) Form # SB_PURY-P144ZKMU-A(-BS)_201606 Specifications are subject to change without notice. www.MitsubishiElectric.ca © 2015 Mitsubishi Electric Sales Canada Inc. 1347(53-1/16) <Accessories> ●Connecting pip <Low pressure> ● Elbow(IDø28.58(1-1/8)×ODø28.58(1-1/8)) ● ● ● P120,P144,P168 1pc. <High pressure> ● Pipe (IDø25.4(1)×IDø19.05(3/4)) ● ● ● P120 1pc. ● Pipe (IDø25.4(1)×ODø19.05(3/4)) ● ● ● P120 1pc. ● Pipe (IDø25.4(1)×IDø22.2(7/8)) ● ● ● P144,P168 1pc. ● Pipe (IDø25.4(1)×ODø22.2(7/8)) ● ● ● P144,P168 1pc. Module: PURY-P144ZKMU-A (-BS) - DIMENSIONS Unit: mm (in.)
© Copyright 2026 Paperzz