IFEA Industriell kommunikasjon AS-i Training 1 Agenda • AS-i safety basics • Safety Output • ASIMON 3G2 • Current Devices • Troubleshooting Safety AS-i Training 2 AS-i Training 3 AS-i Training 4 AS-i Safety at Work AS-i Training 5 Safety at work - Headlines • Integration of all binary safety-related components in AS-Interface, such as: – – – – Emergency stop Protective door switch Safety light barriers/grids Contactor controls, etc. • Mixed operation of standard and safety-related components via the yellow AS-Interface cable AS-i Training 6 Features of the system • Can be used up to control category 4 / PLe / SIL 3 • Response time max. 40 ms • Safe data transmission approved by BIA1 and TÜV2 • Full compatibility with all other AS-Interface components according to EN 50 295 and IEC 62026-2 • Use of the standard AS-Interface protocol • Maximum extension of the system with 31 safety slaves • Stop category 0 or 1 can be selected BIA¹: Berufsgenossenschaftliches Institut für Arbeitssicherheit TÜV²: Technischer Überwachungsverein AS-i Training 7 Programming with ASIMON AS-i Training 8 AS-i Training 9 Example AS-i safety at work network AS-i Training 10 Function of the safety slaves • Each slave has a specific 8 * 4 bit code table • Through a “teach-in“ function the safety monitor reads in the code tables of all safety slaves • During operation permanent comparison of the expected and the transmitted code tables takes place • The system is switched off by the safety monitor when the expected code ≠ the transmitted code, i.e. when: A stop is called (0000) Communication is interrupted The transmitted sequences are wrong The safety slave is disrupted Slave responses are missing or disrupted AS-i Training 11 Transmission of the safe data Safety unit Master sends request to the slave Safety slave AS-i Training 12 Transmission of the safe data Safety unit 0101 010100111010101011010011101011011 Slave answers with his safe code sequence Safety slave AS-i Training 13 Transmission of the safe data Bit 3 2 1 0 3 2 1 0 3 2 1 0 3 2 1 0 1st transmission 0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0 2nd transmission 0 0 1 1 0 0 1 1 0 0 0 0 0 0 0 0 3rd transmission 0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0 4th transmission 0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0 5th transmission 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0 0 6th transmission 0 1 1 1 0 0 1 1 0 1 0 0 0 0 0 0 7th transmission 0 1 0 1 0 0 0 1 0 1 0 0 0 0 0 0 8th transmission 1 0 1 1 0 0 1 1 1 0 0 0 0 0 0 0 AS-i Training 14 Evaluation of the safe data Code Table AS-i Training Sequences transmited 15 AS-i Training 16 Function of the safe output 1 safety relay output Safety address Diagnosis + 1 input (EDM) AB-Slave AS-i Training AS-i relay output module with standard 4 inputs Safety address + AB slave 17 Function of the safe output • A safe output needs a safe address and a A/B-address • The voltage supply is made completely out of AS-i • The safety unit sends a 7 x 4 code sequence as answer to the master request – the safe output „hears“ this code sequence and compares it with the intern code sequence and switches correspondingly • Several outputs can have the same safe address but never the same unsafe address • The unsafe address is used for the transmission of diagnosis data is transmitted or for switching the safe output (after validation by the safety logic) AS-i Training 18 Function of the safe output Safe output slave Safety unit Master sends request • Safety unit answers with safe code sequence The safe output slave compares the code sequence (that depends from the slave address) and switches correspondingly that means it is possible to have several safe output slaves on the same safe address AS-i Training 19 AS-i Training 20 Functions ASIMON 3.0 G2 • New graphical display – – – – – – Preprocessing is not necessary anymore Very clear view similar to a circuit diagram „Old“ view can be selected if needed Each OSSD is displayed in its own window Project manager, component manager & device library SafeLink It is easier to create, understand and diagnose the programs AS-i Training 21 Functions ASIMON 3.0 G2 • Further important innovations – It is possible to define user devices – Integration of the AS-i Control Tools in the ASIMONSoftware – Print functionality – Support of safety outputs – Support of coupling slaves – Support of up to 32 OSSD – Great improvement of the handling (Copy + Paste etc.) AS-i Training 22 Functions ASIMON 3.0 G2 AS-i Training 23 Functions ASIMON 3.0 G2 AS-i Training 24 Functions ASIMON 3.0 G2 AS-i Training 25 Functions ASIMON 3.0 G2 AS-i Training 26 Functions ASIMON 3.0 G2 AS-i Training 27 Functions ASIMON 3.0 G2 AS-i Training 28 AS-i Training 29 Small systems AS-i Training 30 Middle sized systems AS-i Training 31 Large systems AS-i Training 32 Device diagnosis • Diagnosis in plain text at the display – It is possible to obtain an improved diagnosis directly via the display even without programming it – Specialties as e.g. duplicate AS-i address detector, AS-i earth fault detector and AS-i noise detector are already integrated – The current status of the safety components can be displayed as well as the switch off history A complete diagnosis is available without further programming AS-i Training 33 Device diagnosis 1.24 TEST! : SAFETY GUARD1 1 +F YELLOW 6 +RED 10 +RED DIAGNOSE AS-i Training 34 Device chip card • Chip card for storage integrated in the device – Storage of up to 4 different programs – Very simple change in the functionality possible by only changing the chip card (PC is not required) – If you replace the device you will only have to insert the chip card into the new device – Operation is also possible without chip card In case of failure the downtime is reduced drastically AS-i Training 35 AS-i Training 36 Replacing AS-i safety components • Replacing a safety AS-i slave • Teaching individual AS-i slaves’ code sequences • Replacing the monitors AS-i Training 37 AS-i Training 38 Replacing a safety slave • Disconnect the defective slave from the AS-i circuit AS-i Training 39 Replacing a safety slave • Press the „ESC Service“ button for 3 seconds ESC Service 3s SLAVE 24 TO BE CONNECTED THEN PRESS SERVICE LONG AS-i Training 40 Replacing a safety slave • Connect the new safety slave (either with the address 0 or with the correct address of the defective slave) AS-i Training 41 Replacing a safety slave • Press the „ESC Service“ button again for 3 seconds ESC Service 3s TEACHING CODES SLAVE ADR. 24 RX ESC AS-i Training 42 Replacing a safety slave • Close the contacts at the new slave AS-i Training 43 AS-i Training 44 Teaching the code sequences PROFIBUS QUICK SETUP AS-I AS-I SAFETY SAFETY DIAGNOSIS OK TEACH SAFETY SAFETY TEACH SAFE OUTPUT CH SAFE COUPLING START / STOP OK AS-i Training 45 Teaching the code sequences TEACH CODES COMPLETE COMPLETE SINGLE SLAVE COUPLING SLAVE AS-i Training 46 AS-i Training 47 Replacing a monitor • Disconnect the defective monitor from the power supply and remove it from the AS-i circuit AS-i Training 48 • Remove the chip card from the defective monitor and insert it into the new monitor AS-i Training 49 Replacing a monitor • Connect the new monitor to the power supply AS-i Training 50 Replacing a monitor • To copy a configuration you have to insert the code to validate it COPY BANK A TO MONITOR COMPLETE CONFIGURATION: D307 TYPE CODE? D307 OK AS-i Training SET OK 51 Replacing a monitor • Restart the monitor and check the safety installation START MONITOR OK OK AS-i Training 52 AS-i Training 53
© Copyright 2026 Paperzz