3M™ Attest™ Rapid Readout Biological Indicator System for

Confidence.
In just 4 hours.
3M™ Attest™ Rapid Readout Biological Indicator System
for STERRAD® 100NX® System, STERRAD® NX® System, STERRAD® 100S System, and Amsco® VPRO® maX Low
Temperature Sterilization System
Small vial.
Big difference.
In this small vial are over a million spores that provide a game-changing 4-hour rapid
biological indicator result for vaporized hydrogen peroxide sterilization. Six times
faster than before*. 3M™ Attest™ Rapid Readout Biological Indicators make it easier
to practice every load monitoring—which provides patients with the highest and most
consistent quality of care—no matter which sterilization modality is used.
It’s a matter of trust.
For decades, sterile processing departments have counted on 3M biological
indicators to monitor steam sterilization loads. We’ve earned your trust one
load at a time, with more than 850 million cycles monitored by 3M™ Attest™
biological indicators worldwide.
Now that same trusted rapid readout technology can be applied to vaporized
hydrogen peroxide sterilization.
Place the Attest biological indicator
in a peel pouch.
Know sooner to respond faster.
Four-hour results with the 3M™ Attest™ Rapid Readout Biological Indicator
System for Vaporized Hydrogen Peroxide Sterilization give you the information
you need when there is still time to act.
Standardize the way you work.
Are you currently waiting to release steam loads until the biological result
is known, but not holding hydrogen peroxide loads? With faster biological
indicator results, it’s possible to standardize release practices across your
sterilization modalities.
Simplify your workflow.
With faster results and the user-friendly 3M™ Attest™ Auto-reader 490H
interface, you can document results on the same day, during the same shift.
With four-hour results, employees can say goodbye to coming in on weekends
or holidays to read and record biological indicator results.
*Compared to FDA-cleared, commercially available products March 2016.
Avoid documentation errors.
Improve accuracy and streamline your record keeping by connecting
the Attest Auto-reader 490H to your instrument tracking system from
Censis (Censitrac®), Haldor (ORLocate®), or Microsystems (SPM®).
Biological indicator results and other key information will automatically
flow into your system.
For facilities not currently using instrument tracking system software,
a free web app for the Attest Auto-reader 490H, with mobile device
and PC remote access options, is available.
Get the confidence of consistency.
Get the sterilization assurance information you need with the family of “Key Three” monitoring products from 3M.
The same vibrant blue-to-pink chemical indicator color change occurs across all the monitoring products for vaporized
hydrogen peroxide sterilization.
3M™ Comply™ Hydrogen Peroxide
Indicator Tape 1228 confirms a pack
heading to the OR has been exposed
to a vaporized hydrogen peroxide
sterilization cycle.
3M™ Comply™ Hydrogen Peroxide
Chemical Indicators 1248 confirm
to the OR that sterilant has
penetrated to the point of
placement in the pack.
And the 3M™ Attest™ Rapid Readout
Biological Indicators 1295, when used
with the Attest Auto-reader 490H,
demonstrate the lethality of the
sterilization cycle.
Take control for greater peace of mind.
With fast four-hour results, you can know sooner, respond faster, and drive toward improved patient safety in your
facility.
Call your 3M Sales Representative or visit go.3M.com/VH202.
3M™ Attest™ Rapid Readout Biological Indicator System for Vaporized Hydrogen Peroxide Sterilization
Catalog
Number
Description
Packaging
Shipping
30 each/
bag
4 bags/
case
1 unit/box
1 box/case
250 each/
bag
4 bags/
case
3M™ Attest™ Rapid Readout Biological Indicator for
Vaporized Hydrogen Peroxide Sterilization
1295
For STERRAD® Sterilizers 100NX (Standard, Flex, Express
and Duo cycles), NX (Standard and Advanced cycles), 100S,
and Amsco® VPRO® maX Low Temperature Sterilization System
(Lumen, Non Lumen, and Flexible cycles)
Results in four hours
Must be used in conjunction with the 3M™ Attest™
Auto-reader 490H
3M™ Attest™ Auto-reader
490H
For use with 3M Attest Rapid Readout Biological Indicator
for Vaporized Hydrogen Peroxide Sterilization 1295
Includes ethernet cable for Web app connectivity
3M™ Comply™ Hydrogen Peroxide Chemical Indicator
1248
An internal chemical indicator for use with STERRAD® Sterilizer
models 100NX (Standard, Flex, Express and Duo cycles), NX
(Standard and Advanced cycles), 100S, and 100
Chemical indicator bar changes from blue to pink after exposure
to vaporized hydrogen peroxide
2.0cm x 10cm (13/16” x 4”)
3M™ Comply™ Hydrogen Peroxide Indicator Tape
1228
For use with STERRAD® sterilizer models 100NX (Standard, Flex,
Express and Duo cycles), and NX (Standard and Advanced cycles),
100S, and 100
Chemical indicator lines change from blue to pink when exposed
to vaporized hydrogen peroxide
24 rolls/
case
White with blue stripes
1.9cm x 55m (3/4” x 60yds.)
Quick links:
For more information
Connect with your local 3M representative
Watch the low temperature sterilization webinar
Get the reference guide about published standards and guidelines
Visit go.3M.com/VH2O2 for more information
Call the 3M Health Care Customer Helpline at 800.228.3957
3M Health Care
3M Infection Prevention Division
3M Center, Building 275-4E-01
St. Paul, MN 55144 USA
1.800.228.3957
3M.com/medical
3M, Attest, and Comply are trademarks of 3M. Sterrad,
100NX, and NX are registered trademarks of Advanced
Sterilization Products, Division of Ethicon US, LLC. Amsco and
VPRO are registered trademarks of Steris Corporation. Censitrac
is a registered trademark of Censis Technologies, Inc. ORLocate
is a registered trademark of Haldor Advanced Technologies,
Ltd. SPM is a registered trademark of Materials Management
Microsystems.
Please recycle. Printed in USA.
© 3M 2016. All rights reserved.
Issued 12/16.
70-9700-0008-2