CONSTRUCTION CROSS-SECTION DRAWINGS AND GUIDE SPECIFICATIONS FOR CAMBRIDGE INTERLOCKING PAVINGSTONES Index of Drawings NO. DESCRIPTION ▲ ▲ NO. DESCRIPTION ▲ 19 Fountain Patio/Sidewalk/Plaza On Compacted Aggregate Base ▲ 20 Roof Deck Over Habitable Space Roof Deck Over Uninhabited Space Patio/Sidewalk/Plaza On Concrete Base ▲ 21 03 22 04 Street/Parking Lot/Residential Driveway Overlay On Existing Concrete Pavement Parking Garage Over Uninhabited Space – Expansion Joint 23 05 Street/Parking Lot/Residential Driveway Overlay On Existing Asphalt Pavement Parking Garage Over Inhabited/ Uninhabited Space – Drain 24 06 Heated Sidewalk/Driveway Parking Garage Over Inhabited Space – Expansion Joint 07 Interior Concrete Base ▲ 25 Bridge Deck 08 Steps ▲ 26 Gas Station On Cement Treated Base 09 Street/Parking Lot On Compacted Gravel Base ▲ 27 Port/Industrial/Airfield Pavement With Cement Treated Base Concrete Curb And Gutter ▲ 28 11 Crosswalk On Compacted Aggregate Base ▲ Port/Industrial Pavement On Existing Asphalt Or Concrete 12 Crosswalk On Concrete Base 29 Airfield Pavement With Cement Treated Or Asphalt Base 13 Crosswalk On Asphalt Or Cement Treated Base ▲ 30 Airfield Pavement On Existing Asphalt Or Concrete 14 Utility Structure ▲ 31 15 Utility Structure – Value Box/Pull Box/ Lamphole ▲ Turfstone – Firelane/Driveway/ Intermittent Parking ▲ 32 Turfstone – Slope Protection Catch Basin ▲ 33 Turfstone – Riparian Stabilization 17 Tree Pit – Non-Compacted Root Zone ▲ 34 Ditch Liner For Intermittent Flows 18 Slope Protection 35 Turfstone – Boat Ramp 01 02 10 Residential Driveway With Concrete Edges 16 ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ Cambridge Pavers, Inc. ▲ PO Box 157 ▲ Lyndhurst, NJ 07071.0157 Order/Dispatch: Fax 201.933.2230 Phone: 201.933.5000 Administration Fax: 201.933.5532 Find Us Online: www.cambridgepavers.com CONCRETE CURB SET 1/4" (70 MM) BELOW TOP OF CAMBRIDGE PAVERS AND CONTROL JOINTS @ 15' (5 M) OC CAMBRIDGE PAVER 2 3/8" (60 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND COMPACTED AGGREGATE BASE 6" (150 MM) MIN DEPTH GEOTEXTILE AS REQUIRED TURN UP AT SIDES TO COVER BASE CAMBRIDGE-01 DRAWING NO. COMPACTED SUBGRADE 12" (300 MM) WIDE GEOTEXTILE ALONG PERIMETER TURN UP AT CURB (DO NOT COVER TOP OF BASE) NOTES: 1. THICKNESS OF AGGREGATE BASE WILL VARY WITH SUBGRADE CONDITIONS AND CLIMATE. COLDER CLIMATES MAY REQUIRE THICKER BASES. 2. CAMBRIDGE PAVERS SHOULD BE PLACED ON A CEMENT TREATED BASE IF SOIL IS EXTREMELY WEAK OR CONSTANTLY SATURATED. PAVERS CAN BE OVERLAID OR INLAID ON EXISTING ASPHALT OR CONCRETE DRIVEWAYS. PLASTIC, STEEL, ALUMINUM OR PRECAST CONCRETE EDGING MAY BE USED. 3. RESIDENTIAL DRIVEWAY WITH CONCRETE EDGES MIN 6" WIDE x 12" DEEP (150 MM x 300 MM) CONCRETE CURB SET 1/4" (7 MM) BELOW TOP OF PAVERS AND CONTROL JOINTS @ 15' (5 M) OC CAMBRIDGE PAVERS 2 3/8" (60 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND 12" (300 MM) WIDE GEOTEXTILE ALONG PERIMETER TURN UP AT CURB (DO NOT COVER TOP OF BASE) CONCRETE / ASPHALT BASE 4" (100 MM) MIN. THICKNESS FOR CONCRETE 3" (75 MM) MIN. THICKNESS FOR ASPHALT COMPACTED SUBGRADE CAMBRIDGE-03 DRAWING NO. 2" (50 MM) DIA. DRAIN HOLE FILLED WITH PEA GRAVEL LOCATE AT LOWEST ELEVATIONS NOTE: 1. THICKNESS OF BASE WILL VARY WITH SUBGRADE CONDITIONS AND CLIMATE. COLDER CLIMATES MAY REQUIRE THICKER BASES. PATIO / SIDEWALK / PLAZA ON CONCRETE BASE CONCRETE CURB SET 1/4" (7 MM) BELOW TOP OF PAVERS AND CONTROL JOINTS @ 15' (5 M) OC CAMBRIDGE PAVER 2 3/8" (60 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND COMPACTED AGGREGATE BASE 4" (100 MM) MIN. THICKNESS COMPACTED SOIL SUBGRADE EXISTING BASE EXISTING SOIL SUBGRADE 1. DRAIN BEDDING SAND OF EXCESS MOISTURE THROUGH PAVEMENT AT LOWEST POINT OR AT CATCH BASIN(S). SEE DRAWING NO. CAMBRIDGE-03. STREET/PARKING LOT/RESIDENTIAL DRIVEWAY OVERLAY ON EXISTING CONCRETE PAVEMENT CAMBRIDGE-02 DRAWING NO. CAMBRIDGE-04 DRAWING NO. EXISTING CONCRETE PAVEMENT GEOTEXTILE APPROX. 1" TO 1 1/2" (25-40 MM) BEDDING SAND CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS (2 3/8" (60 MM) MIN. THICKNESS FOR RESIDENTIAL DRIVEWAY) EXISTING CONCRETE CURB PATIO / SIDEWALK / PLAZA ON COMPACTED AGGREGATE BASE NOTE: 1. THICKNESS OF BASE WILL VARY WITH SUBGRADE CONDITIONS AND CLIMATE. COLDER CLIMATES MAY REQUIRE THICKER BASES. NOTE: VARIES NOTE: CONCRETE CURB AND FOUNDATION PER LOCAL STANDARDS CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS. 2 3/8" (60 MM) MIN. THICKNESS FOR RESIDENTIAL DRIVEWAY 1"-1 1/2" (25-40 MM) BEDDING SAND NOTE: HEATED SIDEWALK / DRIVEWAY CONCRETE FOOTER CONCRETE BASE FOR STEPS CONCRETE CURB GEOTEXTILE TURN UP AT CURB CAMBRIDGE PAVER 2 3/8" (60 MM) MIN. THICKNESS 1 1/2" (40 MM) BEDDING SAND ELECTRIC HEAT TRACING OR FLEXIBLE HOSE LAYOUT DETERMINED BY MANUFACTURER CONCRETE BASE 4" (200 MM) MIN. THICKNESS OR COMPACTED AGGREGATE BASE 6" (150 MM) MIN. THICKNESS COMPACTED SOIL SUBGRADE CAMBRIDGE-06 ADHESIVE AT JOINTS AND BOTTOMS CAMBRIDGE-08 DRAWING NO. 6"-7" (150-175 MM) RISE CAMBRIDGE PAVER 2 3/8" (60 MM) MIN. THICKNESS SLOPE TO DRAIN 1/4" (7 MM) NOSE 1. USE OF MORTAR IS NOT RECOMMENDED IN PLACE OF ADHESIVE. STEPS WITH CAMBRIDGE PAVERS DRAWING NO. AGGREGATE SUB-BASE AS REQUIRED UNDER CONCRETE NOTES: 1. HEATED ASSEMBLIES CAN BE PLACED ON A CEMENT TREATED BASE OR COMPACTED GRAVEL. 2. ON CONCRETE BASE, PROVIDE PEA GRAVEL-FILLED WEEP HOLE(S) AT LOWEST POINT(S). COVER TOP OF HOLE WITH GEOTEXTILE. ON AN AGGREGATE BASE, GEOTEXTILE IS ONLY REQUIRED ALONG THE CURB. FLEXIBLE HOSE CAN BE PLACED IN TOP LAYER OF AGGREGATE BASE. 3. 4. VARIES GEOTEXTILE EXISTING ASPHALT PAVEMENT (OR CONCRETE) EXISTING AGGREGATE BASE EXISTING SOIL SUBGRADE 2" (50MM) DIA. DRAIN HOLE, FILL WITH PEA GRAVEL. LOCATE AT LOWEST ELEVATIONS. 1. DRAIN BEDDING SAND OF EXCESS MOISTURE THROUGH PAVEMENT AT LOWEST POINTS AS SHOWN OR AT CATCH BASIN(S). CAMBRIDGE-05 DRAWING NO. CAMBRIDGE-07 DRAWING NO. EXISTING CONCRETE FLOOR GEOTEXTILE AT EDGES & OVER JOINTS 1" (25 MM) BEDDING SAND CAMBRIDGE PAVER WITH SEALER 2 3/8" (60 MM) MIN. THICKNESS DOORS, WINDOWS, OR WALLS ON CONCRETE FOUNDATION STREET/PARKING LOT/RESIDENTIAL DRIVEWAY OVERLAY ON EXISTING ASPHALT PAVEMENT INTERIOR CONCRETE BASE 6 (150 MIN VARIES STREET / PARKING LOT ON COMPACTED GRAVEL BASE CONCRETE CURB AND FOUNDATION PER LOCAL STANDARDS CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND 12" (300 MM) WIDE GEOTEXTILE ALONG PERIMETER TURN UP AT CURB WALK / GRASS CONCRETE CURB AND GUTTER PER LOCAL STANDARDS WITH 90 DEGREE FACE CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS 12" (300 MM) WIDE GEOTEXTILE ALONG PERIMETER TURN UP AGAINST CURB CAMBRIDGE-10 DRAWING NO. GEOTEXTILE AS REQUIRED COMPACTED SOIL SUBGRADE 1" TO 1 1/2" (25-40 MM) BEDDING SAND 1. DRAIN MAY BE NECESSARY IN SOIL SUBGRADE. EXISTING ASPHALT PAVEMENT SAW-CUT PAVEMENT SEAL JOINT CONCRETE CURB MIN. 12" (300 MM) WIDE x 12" (300 MM) DEEP CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND GEOTEXTILE CONCRETE BASE WIRE WELDED FABRIC OR STEEL REBAR AS REQUIRED COMPACTED SOIL SUBGRADE CROSSWALK ON CONCRETE BASE CAMBRIDGE-12 DRAWING NO. AGGREGATE SUB-BASE AS REQUIRED 8" 2" (50 MM) DIA. DRAIN HOLE (200 LOCATE AT LOWEST ELEVATIONS MI FILL WITH PEA GRAVEL NOTES: 1. BASE THICKNESS AND REINFORCING VARIES WITH TRAFFIC, CLIMATE, AND SUBGRADE CONDITIONS. 2. CONCRETE BASE MINIMUM 2% SLOPE FROM CENTERLINE TO CURB. 3. DO NOT USE DRAIN HOLES TO SUBGRADE WHEN WATER TABLE IS LESS THAN 2' (0.6 M) FROM TOP OF SUBGRADE. DRAIN TO CATCH BASINS. NOTE: COMPACTED AGGREGATE BASE CAMBRIDGE-09 CAMBRIDGE-11 CONCRETE CURB AND GUTTER WITH CAMBRIDGE PAVERS COMPACTED AGGREGATE BASE VARIES GEOTEXTILE AS REQUIRED GEOTEXTILE AS REQUIRED CROSSWALK ON COMPACTED AGGREGATE BASE DRAWING NO. GEOTEXTILE 12" (300 MM) WIDE, TURN UP AGAINST CURB COMPACTED AGGREGATE BASE CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND CONCRETE CURB MIN. 8" (200 MM) WIDE x 16" (400 MM) DEEP SAW-CUT PAVEMENT SEAL JOINT EXISTING ASPHALT PAVEMENT DRAWING NO. COMPACTED SOIL SUBGRADE NOTES: 1. DRAIN MAY BE NECESSARY IN SLOW DRAINING SUBGRADE. 2. BASE THICKNESS VARIES WITH TRAFFIC, CLIMATE, AND SUBGRADE CONDITIONS. COLDER CLIMATES AND WEAK SOILS MAY REQUIRE THICKER BASES. DO NOT COVER ENTIRE TOP OF AGGREGATE BASE WITH GEOTEXTILE. 3. VARIES COMPACTED SOIL SUBGRADE REBAR AS REQUIRED NOTES: 1. BASE THICKNESS VARIES WITH TRAFFIC, CLIMATE, AND SUBGRADE CONDITIONS. 2. CONCRETE CURBS DO NOT DEFLECT TO THE SAME DEPTH AS CAMBRIDGE PAVERS OR EXISTING ASPHALT. THIS DETAIL IS NOT RECOMMENDED FOR OTHER THAN LOW VOLUME RESIDENTIAL STREETS. THICKENING ASPHALT PAVEMENT ADJACENT TO CONCRETE CURB IS RECOMMENDED. 3. VARIES VARIES VARIES VARIES REBAR CROSSWALK ON ASPHALT OR CEMENT TREATED BASE A CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND GEOTEXTILE AS REQUIRED BASE MATERIAL SECTION AA UTILITY STRUCTURE VALVE BOX \ PULL BOX \ LAMPHOLE EXISTING ASPHALT PAVEMENT SAW-CUT PAVEMENT SEAL JOINT 12" (300 MM) WIDE GEOTEXTILE ALONG PERIMETER TURN UP AT CURB CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND EXISTING ASPHALT PAVEMENT EXISTING AGGREGATE BASE COVER CAMBRIDGE-15 DRAWING NO. SUBGRADE 12" (300 MM) WIDE GEOTEXTILE TURN UP AGAINST COLLAR COVER CONCRETE COLLAR MIN. 8" WIDE x 8" DEEP (200 MM X 200 MM) ELEVATION TO BE 1/4" (7 MM) BELOW PAVERS REBAR A CAMBRIDGE-13 DRAWING NO. EXISTING SUBGRADE 2" (50 MM) DIA. DRAIN HOLES AT LOWEST ELEVATIONS, FILL WITH PEA GRAVEL, COVER WITH GEOTEXTILE NOTES: 1. BASE THICKNESS VARIES WITH TRAFFIC, CLIMATE, AND SUBGRADE. COLDER CLIMATES AND WEAK SOIL MAY REQUIRE THICKER BASES. BOTTOM ELEVATION OF EXISTING ASPHALT PAVEMENT MUST BE EVEN OR BELOW BEDDING SAND. CONCRETE BEAMS AT ENDS OF PAVEMENT MAY BE NECESSARY IF ASPHALT IS SUBJECT TO RUTTING. DO NOT USE DRAIN HOLES TO SUBGRADE WHEN WATER TABLE IS LESS THAN 2' (0.6 M) FROM TOP OF SUBGRADE. DRAIN TO CATCH BASINS. 2. 3. 4. VARIES A REBAR CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND BASE MATERIAL SECTION AA CONCRETE UTILITY STRUCTURE CONCRETE BRICK AS REQUIRED GEOTEXTILE 12" (300 MM) WIDE GEOTEXTILE TURN UP AGAINST COLLAR UTILITY STRUCTURE A GRATE AND FRAME CONCRETE COLLAR 1. SIZE AND REINFORCING OF CONCRETE VARIES WITH TRAFFIC. SECTION AA CAMBRIDGE PAVERS 3 1/8" (80 MM) 1" TO 1 1/2" (25-40 BEDDING SAND BASE MATERIAL GEOTEXTILE NOTE: CATCH BASIN COVER STRING COURSE OF PAVERS AROUND COLLAR A COVER CONCRETE COLLAR MIN. 8" (200 MM) WIDE ELEVATION TO BE 1/4" (7MM) BELOW PAVERS REBAR AS REQUIRED CAMBRIDGE-14 DRAWING NO. A REBAR STRING COURSE OF PAVERS AROUND COLLAR GRATE AND FRAME CONCRETE COLLAR MIN. 8" (200 MM) WIDE ELEVATION TO BE 1/4" (7MM) BELOW CAMBRIDGE PAVERS REBAR 12" (300 MM) WIDE GEOTEXTILE TURN UP AGAINST COLLAR COMPACTED SOIL SUBGRADE CONCRETE CATCH BASIN PER LOCAL STANDARD CAMBRIDGE-16 DRAWING NO. EXISTING CURB MIN. 2 3/8" (60 MM) THICK CAMBRIDGE PAVERS OVER ROOT ZONE MIN 1/4" (7 MM) WIDE JOINTS APPROX. 1" TO 1 1/2" (25-40 MM) BEDDING SAND GEOTEXTILE LAVA SLAG WITH TREE PIT SOIL MIX 2 TO 1 IN ROOT ZONE 12" (300 MIN GEOTEXTILE B AND B TREE TREE GRATE WASHED AGGREGATE TREE PIT WITH PLANTING SOIL MIN. DEPTH 3' (.9 M) CONCRETE COLLAR CAMBRIDGE-19 DRAWING NO. CAMBRIDGE-17 DRAWING NO. 95% COMPACTION OF SOIL UNDER ROOTBALL 4" (100 MM) DIA. PERFORATED PLASTIC PIPE WRAPPED WITH WASHED AGGREGATE AND FILTER FABRIC DRAIN TO STORM SEWER TREE PIT - NON-COMPACTED ROOT ZONE UNDER CAMBRIDGE PAVERS SPRAY NOZZLE DRAIN WITH HOLES AT TOP OF CONCRETE BASE CAMBRIDGE PAVER WITH EMPTY JOINTS 2 3/8" (60 MM) MIN. THICKNESS ADHESIVE CONCRETE BASE FOUNTAIN WALL DRAIN HOLES AT BOTTOM OF CAMBRIDGE PAVERS/TOP OF CONCRETE NOTE: 1. CAMBRIDGE PAVERS CAN BE LAID WITHOUT ADHESIVE. FOUNTAIN CAMBRIDGE PAVER 2 3/8" (60 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND GEOTEXTILE COMPACTED SUBGRADE SEGMENTAL RETAINING WALL BOND TOP COURSE COMPACTED OPEN GRADED AGGREGATE WRAPPED IN GEOTEXTILE PIPE DRAIN FOOTER AS REQUIRED BY WALL DESIGN RIGID INSULATION WITH GROOVED BOTTOM FOR DRAINAGE THICKNESS VARIES WITH LOCAL CODES AND CLIMATE CAMBRIDGE PAVER 2 3/8" (60 MM) MIN. THICKNESS 1" (25 MM) THICK BEDDING SAND GEOTEXTILE OVERLAP ENTIRE STRIP SEAL PROTECTION BOARD GROOVED BOTTOM FOR DRAINAGE AT BOTTOM CAMBRIDGE-20 DRAWING NO. CAMBRIDGE-18 DRAWING NO. NOTES: 1. MAXIMUM SLOPE SHOULD NOT EXCEED ANGLE OF REPOSE FOR BEDDING SAND. 2. PROVIDE EDGE RESTRAINTS ON SIDES OF INSTALLATION. 3. ENGINEERING OF THE SEGMENTAL RETAINING WALL IS REQUIRED WHEN HEIGHT EXCEEDS 4' (1.0 M). SLOPE PROTECTION CAMBRIDGE PAVERS 6 (150 MIN ROOF DRAIN GASKET HOLES FOR DRAINAGE ROOF DECK OVER HABITABLE SPACE WATERPROOF MEMBRANE OVERLAP ENTIRE ALUMINUM PLATE STRUCTURAL SLAB SLOPE TO DRAIN ALUMINUM PLATE MIN. 1/8" (3 MM) THICK FASTEN ON ONE SIDE COMPRESSION SEAL AT CONTROL JOINT NOTES: 1. CHECK WITH LOCAL WIND CODES FOR BALLAST REQUIREMENTS. 2. PROTECTION BOARD AND INSULATION MUST WITHSTAND STATIC AND DYNAMIC LOADS. 1/2 (13 MIN 12" (300 MIN 6" (150 MIN CAMBRIDGE PAVER 2 3/8" (60 MM) MIN. THICKNESS 1" (25 MM) BEDDING SAND GEOTEXTILE OVERLAP ENTIRE PLATE PROTECTION BOARD GROOVED BOTTOM FOR DRAINAGE AT BOTTOM ROOF DRAIN ROOF DECK OVER UNINHABITED SPACE PARKING GARAGE OVER INHABITED / UNINHABITED SPACE - DRAIN DRAWING NO. CAMBRIDGE-21 CAMBRIDGE-23 DRAWING NO. CONCRETE ROOF DECK SLOPE TO DRAIN WATERPROOF MEMBRANE NOTES: 1. PROTECTION BOARD AND INSULATION MUST WITHSTAND STATIC AND DYNAMIC VEHICULAR LOADS. 2. INSULATION MAY BE EXCLUDED FOR SOME APPLICATIONS OVER INHABITED SPACE. CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND GEOTEXTILE TURN UP AT DRAIN AND ALL VERTICAL SURFACES PROTECTION BOARD 1/4" (7 MM) MIN. AS REQUIRED RIGID INSULATION THICKNESS VARIES WITH LOCAL CODES AND CLIMATE ROOF DRAIN HOLES FOR DRAINAGE GASKET HOLES FOR DRAINAGE WATERPROOF MEMBRANE OVERLAP ENTIRE PLATE STRUCTURAL SLAB SLOPE TO DRAIN ALUMINUM PLATE MIN. 1/8" (3 MM) THICK FASTEN ON ONE SIDE COMPRESSION SEAL AT CONTROL JOINT NOTES: 1. CHECK WITH LOCAL WIND CODES FOR BALLAST REQUIREMENTS. 2. PROTECTION BOARD MUST WITHSTAND STATIC AND DYNAMIC LOADS. 1/2 (13 MIN CAMBRIDGE PAVERS 3 1/8" (80 MM) MIN THICKNESS GEOTEXTILE APPROX. 1" TO 1 1/2" (25-40 MM) BEDDING SAND PROTECTION BOARD 1/4" (7 MM) MIN AS REQUIRED WATERPROOF MEMBRANE WATERPROOF ADHESIVE CAMBRIDGE-22 DRAWING NO. STRIP SEAL AT CONSTRUCTION JOINT EPOXY GROUT FILLER PARKING GARAGE OVER UNINHABITED SPACE - EXPANSION JOINT CAMBRIDGE PAVERS 3 1/8" (80 MM) MIN. THICKNESS GEOTEXTILE 1" TO 1 1/2" (25-40 MM) BEDDING SAND PROTECTION BOARD 1/4" (7 MM) MIN. AS REQUIRED RIGID INSULATION WATERPROOF ADHESIVE CAMBRIDGE-24 DRAWING NO. STRIP SEAL AT CONSTRUCTION JOINT EPOXY GROUT FILLER WATERPROOF MEMBRANE STRUCTURAL SLAB SLOPE TO DRAIN PARKING GARAGE OVER INHABITED SPACE - EXPANSION JOINT NOTE: NOTE: 1. BASE, SUB-BASE, AND SUBGRADE THICKNESS VARY WITH LOADS, SUBGRADE STRENGTH, AND CLIMATE. 3. CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS APPROX. 1" TO 1 1/2" (25-40 MM) BEDDING SAND CEMENT TREATED BASE COMPACTED SOIL SUBGRADE CAMBRIDGE-26 DRAWING NO. CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND GEOTEXTILE TURN UP AT SIDES/EDGES EXISTING ASPHALT OR CONCRETE PAVEMENT EXISTING SUB-BASE EXISTING SOIL SUBGRADE PORT / INDUSTRIAL PAVEMENT ON EXISTING ASPHALT OR CONCRETE CAMBRIDGE-28 DRAWING NO. NOTES: 1. EXISTING ASPHALT OR CONCRETE PAVEMENT SHALL BE THOROUGHLY INSPECTED FOR AREAS IN NEED OF PATCHING OR REPLACEMENT. CONDUCT ALL REPAIRS AND FILL ALL CRACKS GREATER THAN 1/4" (7 MM) WIDE PRIOR TO PLACING GEOTEXTILE, SAND, AND CAMBRIDGE PAVERS. PROVIDE DRAINAGE OF SAND LAYER THROUGH PEA GRAVEL-FILLED WEEP HOLE(S) OR CATCH BASIN(S). 2. GAS STATION ON CEMENT TREATED BASE NOTES: 1. BASE, SUB-BASE, AND SUBGRADE THICKNESS VARY WITH LOADS, SUBGRADE STRENGTH, AND CLIMATE. CAMBRIDGE PAVERS MAY BE INLAID ON EXISTING ASPHALT OR CONCRETE GAS STATION PAVEMENTS. SEALING JOINTS OF PAVERS IS RECOMMENDED. 2. VARIES CAMBRIDGE PAVERS 3 1/8" (60 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND EPOXY GROUT FILLER WOVEN GEOTEXTILE SEAL AT JOINT STRUCTURAL SLAB SLOPE TO DRAIN ON STEEL OR CONCRETE BEAMS DRAWING NO. CAMBRIDGE-25 CAMBRIDGE PAVER 3 1/8" (80 MM) MIN. THICKNESS 1" TO 1 1/2" (25-40 MM) BEDDING SAND GEOTEXTILE TURN UP AT SIDES/EDGES CEMENT TREATED BASE COMPACTED AGGREGATE SUB-BASE AS REQUIRED CAMBRIDGE-27 DRAWING NO. COMPACTED OR STABILIZED SUBGRADE PORT / INDUSTRIAL / AIRFIELD PAVEMENT W/CEMENT TREATED BASE VARIES 1. PROVIDE DRAINAGE OF EXCESS MOISTURE IN BEDDING SAND AT PERIMETER OF STRUCTURAL SLAB. BRIDGE DECK VARIES VARIES VARIES 1" TO 1 1/2" (25-40 MM) BEDDING SAND CAMBRIDGE PAVER (FAA,P502) 3 1/8" (80 MM) MIN. THICKNESS WITH SEALER GEOTEXTILE TURN UP AT SIDES TO COVER CAMBRIDGE PAVERS APPROX. 1" TO 1 1/2" (25-40 MM) BEDDING SAND CAMBRIDGE PAVERS (P-502) 3 1/8" (80 MM) MIN. THICKNESS VARIES VEGETATION CAMBRIDGE TURFSTONE 3 1/8" (80 MM) MIN. THICKNESS MAX. SLOPE 1 TO 1 TOPSOIL IN OPENINGS FILL 1/2" (13 MM) BELOW SURFACE SLOPE PROTECTION CAMBRIDGE TURFSTONE COMPACTED EMBANKMENT SOIL CAMBRIDGE-30 CAMBRIDGE-32 DRAWING NO. STAKE EVERY THIRD ROW OF GRIDS WITH 12" x 3/8" DIA. (300 MM x 10 MM) STEEL PINS AIRFIELD PAVEMENT ON EXISTING ASPHALT OR CONCRETE NOTE: 1. EXISTING ASPHALT OR CONCRETE PAVEMENT SHALL BE THOROUGHLY INSPECTED FOR AREAS IN NEED OF PATCHING OR REPLACEMENT. CONDUCT ALL REPAIRS AND FILL ALL CRACKS GREATER THAN 1/4" (7 MM) WIDE PRIOR TO PLACING GEOTEXTILE, SAND, AND CAMBRIDGE PAVERS. EXISTING SUBGRADE EXISTING BASE AND SUB-BASE EXISTING ASPHALT OR CONCRETE PAVEMENT GEOTEXTILE TURN UP AT SIDES TO COVER CAMBRIDGE PAVERS CEMENT TREATED BASE (P-304) OR ASPHALT BASE (P-401) COMPACTED AGGREGATE SUB-BASE AS REQUIRED (P-209 OR P-154, AS REQUIRED) COMPACTED OR STABILIZED SOIL SUBGRADE (P-152) CAMBRIDGE-29 COMPACTED SOIL AT PERIMETER CAMBRIDGE TURFSTONE 3 1/8" (80 MM) MIN. THICKNESS SOD PLUGS OR GRASS SEED TOPSOIL IN OPENINGS FILL 1/2" (13 MM) BELOW SURFACE 1" TO 1 1/2" (25-40 MM) BEDDING SAND CAMBRIDGE-31 DRAWING NO. COMPACTED AGGREGATE BASE GEOTEXTILE AS REQUIRED TURN UP AT SIDES COMPACTED SUBGRADE CAMBRIDGE TURFSTONE-FIRELANE, DRIVEWAY & INTERMITTENT PARKING NOTES: 1. BASE THICKNESS VARIES WITH TRAFFIC, CLIMATE, AND SUBGRADE. 2. MINIMUM BASE THICKNESS: 6" (150 MM) RESIDENTIAL DRIVEWAYS, 8" FIRELANES & PARKING LOTS. 6" (150 MIN AIRFIELD PAVEMENT WITH CEMENT TREATED OR ASPHALT BASE NOTE: 1. BASE, SUB-BASE, AND SUBGRADE THICKNESS VARY WITH LOADS, SOIL STRENGTH, AND CLIMATE. VARIES 12" (300 MM) MIN. 12" (300 MM) MIN. RIP-RAP OR CONCRETE TOE AND SIDES GEOTEXTILE WRAP AROUND TOE ON ALL SIDES FILL OPENINGS ABOVE MEAN WATER LEVEL WITH TOPSOIL AND VEGETATION CAMBRIDGE TURFSTONE 3 1/8" (80 MM) MIN. THICKNESS MAX. SLOPE 1 TO 1 EXTEND MIN. TWO (2) COURSES ABOVE MEAN WATER LEVEL RIPARIAN VEGETATION MEAN WATER LEVEL 24" (600 MM) MIN. RIPARIAN STABILIZATION COMPACTED SUBGRADE DRAWING NO. CAMBRIDGE-33 CAMBRIDGE-35 DRAWING NO. RIP-RAP OR CONCRETE TOE AND SIDES GEOTEXTILE WRAP AROUND TOE ON ALL SIDES COMPACTED SUBGRADE GEOTEXTILE ON SOIL SUBGRADE AS REQUIRED CAMBRIDGE TURFSTONE FOR STREAM BANKS AND LAKESIDES GRAVEL OR PAVED APPROACH RAMP CAMBRIDGE TURFSTONE 3 1/8" (80 MM) MIN. THICKNESS MAX SLOPE = 12 AGGREGATE IN OPENINGS GRAVEL COMPACTED TO 8" (200 MM) MIN. DEPTH 24" (600 MM) MIN. BOAT RAMP CAMBRIDGE TURFSTONE CAMBRIDGE TURFSTONE 3 1/8" (80 MM) MIN THICKNESS MAX SLOPE 1 TO 1 VEGETATION TOPSOIL IN OPENINGS FILL 1/2" (13 MM) BELOW SURFACE COMPACTED SOIL SUBGRADE NOTE: 1. AGGREGATE MAY BE USED IN OPENINGS OF GRID PAVERS. DITCH LINER FOR INTERMITTENT FLOWS - CAMBRIDGE TURFSTONE NOTE: ALL CROSS-SECTION DRAWINGS SHOWN ARE AVAILABLE ON CD-ROM. CAMBRIDGE-34 DRAWING NO. www.cambridgepavers.com
© Copyright 2026 Paperzz