The Material Properties of Ovine Femoral Periosteum 1 1 McBride, S H; 1Evans, S; +1Knothe Tate, M L Case Western Reserve University, Cleveland, OH [email protected] INTRODUCTION The material properties of ovine femoral periosteum are not well characterized. An understanding of these properties is critical to predict the environment of pluripotent and osteochondroprogenitor cells that reside within the periosteum and that have been shown recently to exhibit a remarkably rapid capacity to generate bone de novo [1,2]. Furthermore, as the periosteum serves as the bounding envelope of the femur, anisotropy in periosteal properties may play a key role in modulating bone growth, healing and adaptation, in health, disease and trauma. Our approach was to quantify shrinkage upon release from underlying bone as measure of pre-stress in the periosteum and to measure the modulus of elasticity in diaphyseal periosteum loaded in the axial and circumferential directions. Axial MATERIALS AND METHODS Animal Model: Ovine femoral periostea were harvested from skeletally mature sheep (2 year old ewes, 3/4 hampshire & 1/4 dorset, 62.2 - 79 kg, Ohio Agricultural Research and Development Center, Wooster, OH) within 5 hours of euthanasia. The acute studies were carried out in accordance with Case Western Reserve University Animal Resource Center guidelines under IACUC approved protocols (2010-0014). Fig. 1. Ovine femur. Periosteum sampling sites, testing direction (axial - green, circumferential - grey). Adapted from [3]. Shrinkage Studies: In situ evaluation of periosteal pre-stress necessitated development of protocols to prevent artifacts observed during pilot studies. First, squares of periosteum from the femoral diaphysis (n=3 bones), measuring circa 25% of the diaphysial circumference, were removed from the anterior, medial, posterior, and lateral aspects. Samples were submerged in 3 mL of Dow Corning 200 fluid (Univar USA, Strongsville, OH), a 100 centistoke silicon oil that mitigates swelling and dehydration during testing. Then, the percent change in area, axial length, and circumferential length was measured over time (16.5 hours) using high-resolution imaging (8.13 pixels/µm, Leica DM IRE2, Leica, Wetzlar, Germany) and processing (MatLab, Natick, MA) methods. Hypotheses related to these outcome measures were tested using a one-way ANOVA test with pair-wise comparisons (α=0.05). Data from each aspect were treated as a cohort. To determine differences in length change for each aspect, we analyzed each time point using a paired t-test of the differences between change in circumferential and axial length (α=0.05) (MatLab). Mechanical Testing: To measure the elastic modulus of the periosteum in the axial (Fig. 1) and circumferential directions, a circa 7×1 cm strip of diaphyseal periosteum, centered at the anterior aspect, was removed in either an axial (n = 6, Fig. 1, green overlay) or circumferential (n = 4, Fig. 1, grey overlay) orientation. The periosteum was fixed to a template during resection to maintain the in situ length (7 cm) while allowing limited width (1 cm) relaxation until the strip center was secured in the testing grips. Samples were stretched, at a rate of 0.004 mm/sec (Enduratec ELF 3200, Bose Co, Eden Prarie, MN), to failure (> 0.15 N drop in force). Stress was calculated from the measured force and the cross sectional area of the relaxed specimen. The associated tissue strain was measured optically (Sony DC-HC52 video, Sony Co, New York, NY with digital image correlation, MatLab). The elastic moduli of the respective axial and circumferential toe and elastic regions were measured from the slope of the resulting stress-strain curves. Statistical analysis of differences between elastic moduli of each region was carried out using the one-way ANOVA test with pair-wise comparisons (α=0.05) (MatLab). Each region was treated as a cohort. Fig. 2. Average per cent change in area and length. Change is measured from initial condition in situ, for periosteal area and length. Percent of Initial We hypothesize that • the periosteum is pre-stressed in situ and • periosteum exhibits anisotropic material properties, e.g. the elastic modulus of the periosteum depends significantly on the direction of loading (axial, circumferential, Fig. 1). RESULTS Shrinkage Studies: Periosteum experiences an average of 40-55% decrease in area immediately upon removal from the underlying bone (Fig. 2). At any timepoint, the change in area is not significantly different between aspects. The overall length shrinks 40-50% in axialoriented samples and 2-20% in the circumferential-oriented samples. The change in length is significantly different in the axial and circumferential directions for all aspects of the femur except the lateral aspect. Length Area X Axial O Circumferential Mechanical Testing: The periosteum exhibits a high degree of anisotropy (Fig. 3, Table 1). When strained in the axial direction, an initial compliant toe region is followed by a much stiffer linear elastic region. When strained in the circumferential direction there is no toe region and the tissue behaves approximately twice as stiff as the compliant axial toe region until failure. Figure 3. Periosteal stress-strain curves. Significant anisotropy is observed between elastic regions of axial and circumferential specimens. Table 1. Measured elastic moduli. Sample Region Elastic Modulus (MPa) Axial Toe Region (n=6) 1.9 Axial Elastic Region (n=6) 25.7 Circ. Elastic Region (n=6) 4.4 95% Confidence Interval (0.8, 3.1) (18.8, 32.5) (3.2, 5.6) CONCLUSIONS The periosteum is a pre-stressed, anisotropic material. Based on the results of this study, the periosteum is pre-stressed in the axial direction, resulting in twice higher shrinkage upon release from underlying bone compared to the circumferential direction. Furthermore, the elastic modulus in the axial direction is more than ten fold greater than that in the circumferential direction. These disparate material properties are expected to exert a profound influence on femur mechanobiology during development, growth, healing and aging, in health and disease [2]. These studies may have important implications with regard to the development of implants to replace periosteum when the amount of healthy periosteum is a limiting factor, e.g. after tumor resection as well as battlefield or other high impact, high energy injuries [4]. REFERENCES [1] Knothe Tate et al. J Bone Jt Surg 89(2):307-16, 2007. [2] Knothe et al. J Biomechanics, 2010. [3]http://en.wikibooks.org /wiki/Anatomy_and_Physiology_of_Animals/The_Skeleton [4] Knothe Tate et al. Trans ORS 35:0384. ACKNOWLEDGEMENTS AO Research Fund F-07-99K, NIH/ NIAMS 2T32AR007505, Nick LaFrenz, Matt Kirsch. Poster No. 2212 • ORS 2011 Annual Meeting
© Copyright 2026 Paperzz