MATERIAL SAFETY DATA SHEET Updated on : Revision: 29/06/2015 10 1. PRODUCT AND COMPANY IDENTIFICATION PRODUCT NAME FIRE-TROL® FireFoam® 103B PRODUCT USE Fire suppressant SUPPLIER / MANUFACTURER Address : ICL FRANCE – ICL BIOGEMA S.A.S. 415, Rue Louis Armand Pôle d’activité d’Aix les Milles F 13852 AIX EN PROVENCE CEDEX 3 Phone : Fax : E-mail : Web site : (33) 442 244 508 (33) 442 242 998 [email protected] www.iclbiogema.com EMERGENCY TELEPHONE : (0033) 442 244 508 /(0033) 670 647 782 or (0033) 689 104 300 2. MATERIAL IDENTIFICATION AND INFORMATION PREPARATION Chemical nature: Hazardous components : Mixture of foaming and wetting agents in a non-flammable solvent. (Xi) R 36 / 38 Substance N° CAS Hexylèneglycol n-Octanol 107-41-5 111-87-5 Tensio-actifs anioniques Trade Secret N° EINECS 203-489-0 203-917-6 % w/w < 22% < 2.5% < 30% Risk Phrase (Xi) (Xi) (Xi) 3. HAZARD IDENTIFICATION MAIN HAZARDS Harmful effects on health: Physical and chemical hazards: - Unusual Fire or Explosion Hazards - Specific hazards May cause respiratory tract irritation. May cause eye and skin irritation. The product is not flammable, have no high or low explosive limit. The product is not considered as a poisonous substance according to EC regulations. Product name: FIRE-TROL® FireFoam® 103B 4. EMERGENCY AND FIRST AID PROCEDURES Skin contact : M.S.D.S. Version n° 10 page 2 / 4 Wash off with water. Remove contaminated clothing. Eye contact : Flush eyes immediately with plenty of water for at least fifteen minutes. Get medical attention. Inhalation : Move person to fresh air and provide oxygen if breathing is difficult. Get medical attention. Ingestion: Call a doctor immediately. 5. FIRE FIGHTING PROCEDURES Extinguishing Media : Non flammable extinguishing product. Use water to cool containers exposed to fire. Specific hazards None 6. PROCEDURES IN CASE OF ACCIDENTAL DISPERSION Individual precautions : Wear boots and exercise caution to prevent slip falls. Environmental precaution: Contain the spread. Methods for cleaning up: - Recovery: - Cleaning / decontamination: - Elimination Retrieve the product with shovels and brushes. Spread sand or any absorbing matter over the product. Do not use water which may cause excessive foaming. Incinerate in approved installation. 7. HANDLING AND STORAGE HANDLING Technical measurements: STORAGE Technical measurements: Recommended storage conditions: Packing conditions: Packing materials: - Recommended - Not recommended Follow good industrial practices. Bulk storage, polyethylene tank. Avoid any source of ignition. Polyethylene drums exclusively. Polyethylene drums. Avoid metal tanks. 8. EXPOSURE CONTROL / INDIVIDUAL PROTECTION INDIVIDUAL PROTECTION Hand protection: Eyes protection: Skin protection: Ventilation: Rubber gloves are recommended. Wear safety glasses. Wear appropriate work clothes. Work in a well aerated area. COLLECTIVE EMERGENCY MEANS Water supply. Hygiene measures Not to eat, drink, and smoke during handling. Wash hands after work. Product name: FIRE-TROL® FireFoam® 103B M.S.D.S. Version n° 10 page 3 / 4 9. PHYSICAL AND CHEMICAL PROPERTIES GENERAL INFORMATION Appearance: Solubility: Light amber, low viscosity liquid. Soluble in water IMPORTANT HEALTH, SAFETY AND ENVIRONMENTAL INFORMATION Specific Gravity: pH in 10% aqueous solution : Freezing point: Pour point: Boiling point: Flash point: Viscosity (concentrate): 1.03 kg/dm3 at 25°C. 9.0 - 9.5 - 15.6°C (CEREN 10/2008) -7°C 100°C. > 100°C according to NF T60-103 norm < 200 cP @ 0°C 10. STABILITY AND REACTIVITY Stability : Concentrates have excellent long-term stability for an indefinite period. They can be used at temperatures as low as water freezing temperatures. Do not store in temperatures exceeding 66°C. Incompatibility: Strong oxidizers: H2O2, HNO3, CrO3. Hazardous decomposition : There are no significant hazardous decomposition products from a fire reaction on the diluted product as used in fire fighting. When a fire occurs near stored concentrates, such as in highway accidents, the concentrates break down and release carbon monoxide and sulphur oxides. 11. TOXICOLOGICAL DATA Before concentrate is diluted with water: - Eye irritation : - Skin irritation : - Ingestion : - Acute Oral Toxicity : - Acute Dermal Toxicity : Moderate irritation Slight irritation May cause throat irritation LD50 > 5050 mg/kg (Practically Non-Toxic) LD50 > 2010 mg/kg (Slightly Toxic) Diluted product (1,0% by volume): - Eye irritation : - Skin irritation : - Ingestion : - Acute Oral Toxicity : - Acute Dermal Toxicity : Moderate irritation Slight irritation May cause throat irritation LD50 > 5050 mg/kg (Practically Non-Toxic) LD50 > 2010 mg/kg (Slightly Toxic) 12. ECOLOGICAL DATA ECOTOXICITY Effects on the aquatic environment: None (Ecotoxicity Tests run in 2006 with Daphnia magna STRAUS and Danio rerio HAMILTON BUCHANAN ) PERSISTENCE AND DEGRADABILITY All components are entirely biodegradable. BIO ACCUMULATION None Product name: FIRE-TROL® FireFoam® 103B M.S.D.S. Version n° 10 page 4 / 4 13. DISPOSAL INFORMATION PRODUCT WASTES - Prohibited: - Destruction / elimination: Do not dispose of large quantities in sewerage system. For elimination, comply with applicable local regulations. 14. TRANSPORTATION DATA INTERNATIONAL REGULATIONS - Road / Rail - Sea - Air 15. STATUTORY DATA RID/ADR/RTMD OMI/IMDG OACI/IATA Not regulated for transportation Not regulated for transportation Not regulated for transportation This warning label must be mentioned on packaging materials. LABELLING EEC regulation: 16. OTHER DATA Classifications / Symbols : Cleaning compound Risk Phrase : The concentrate must be classified R36/38 : Xi “Irritant to the eyes and the skin” according to the criteria for classification, packaging and labeling of dangerous substances in compliance with the EEC Directives 67/548, 2001/59 and 99/45. The solution at 0.5% (v/v) must not be classified according to the criteria for classification, packaging and labeling of dangerous substances in compliance with the EEC Directives 67/548, 2001/59 and 99/45. Recommended use : Forest Fire Fighting This safety data sheet was drafted in compliance with EEC Directive 91/155 of March 5, 1991 as amended by Directive 93/112/CE of December 10, 1993 and Directive 2001/58/CE of July 27, 2001. Cause for revision: New danger symbol Replaces MSDS dated: 29/03/2013 FIRE-TROL® and FireFoam® are registered trademarks of ICL Performance Products LP Notice of warranty: This data sheet supplements the technical notes of use but does not replace them. The information contained herein is based on our knowledge of the product concerned at the date indicated. It is given in good faith. Users are hereby warmed of the possible risks of use of the product for purposes other than intended. Users are expected to know and comply with all statutory obligations relating to their activity. Users are solely responsible for the caution they exercise in using the product.
© Copyright 2026 Paperzz