RJT 1x4, 2x2, 2x4 LED Troffer Product Information Project Name Type Catalog Number Date SPECIFICATIONS Features • The RJT is a direct replacement for fluorescent troffers and offers the right options for versatility of use across a wide range of project types. • Choice of four lumen packages and dimming option available. • Same LED door styles, lens types and mounting for 1x4, 2x2 or 2x4 configurations. • Long-life, LEDs at L80 (80% lumen maintenance) at 60,000 hours to reduce life cycle maintenance costs. • Optional emergency battery backup for safety lighting. • Available in 1'x4', 2'x2' and 2'x4'. • Up to 145 lumens per watt. • Color Rendering Index (CRI) > 80. • Multiple shielding options. Construction • Fixture housing, end caps, and reflectors are die-formed code-gauged cold-rolled steel • Hinged optical system allows easy access to LED modules and electrical from below the ceiling • Multiple shielding options. Certain airborne contaminants can diminish integrity of acrylic. Contact factory for chemical compatibility. • Metal to metal light leak protection on all four sides of shielding frame • Two door frame choices • Weight: 1x4-8 lbs. 2x2-7 lbs. 2x4-10 lbs. Electrical • • • • • • • • • Input Voltage Range: 120-277 VAC Nom. Frequency: 50/60 Hz Nom. Active Power Factor Correction Power Factor: >0.90 @ full load, 120V through 277V Harmonic Distortion: THD < 20% @ full load Protection: Over-Voltage, Over-Temperature (110º) & Short Circuit Compliant to FCC Part 15 requirements for EMI/RFI emissions NEC/CEC compliant ballast disconnect is standard. Optional emergency battery pack Certifications • • • • • • CSA listed for Canada and U.S. Tested to UL 1598 & UL 8750 standards. Luminaires bear appropriate listing labels. Emergency-equipped fixtures labeled UL 924. Adheres to LM79, LM80 and TM21 industry standards. DesignLights Consortium® (DLC) qualified. Please refer to the DLC website for specific product qualifications at www.designlights.org. • Please refer to the Lighting Facts website for specific product qualifications at www.lightingfacts.com. Application • Suitable for use with most wired or wireless lighting control systems • Suitable for dry & damp locations: • Government buildings • Retail • Commercial areas • Healthcare facilities • Educational facilities Warranty • Five-year warranty. (Terms and Conditions Apply) CERTIFICATION ORDERING INFORMATION RJT MODEL RJT LED Lensed Troffer Fixture SIZE 14 1x4 Nominal 22 2×2 Nominal 24 2x4 Nominal EXAMPLE RJT22-35HLG-FSA12F-EU – – COLOR TEMP 30 35 40 50 3000K 3500K 4000K 5000K CEILING TYPE G Grid1 SM Surface Mount DOOR FS White Flush LUMEN OUTPUT XW Extra Low Watt (1x4, 2x4) VW Very Low Watt MW Medium Low Watt LW Low (2x4 Only) Steel FA White Flush Aluminum ML Medium (2x2, 2x4) HL High (2x2,2x4) VL Very High (2x2, 2x4) XL Extra High Lumen (2x4 Only) – SHIELDING A12 Pattern 12 Acrylic Lens A12125 Pattern 12 Acrylic Lens, 0.125" Nominal A12F Pattern 12 Frosted Acrylic Lens A12F125 Pattern 12 Frosted Acrylic Lens, 0.125" Nominal A19 Pattern 19 Acrylic Lens, 0.156" Nominal A19F Pattern 19 Frosted Acrylic Lens 0.156" U DRIVER OUTPUT E Fixed ESD Bi-Level2 ED 0-10V – OTHER ELL14 Emergency Battery Pack4 C388 3-Wire Flex, 6', 18 Ga Dimming3 C488 4-Wire Flex, DRIVER VOLTAGE C588 5-Wire Flex, U Universal 120/277 VAC FOOTNOTES 6', 18 Ga 6', 18 Ga ACCESSORIES (ORDER SEPARATELY) FK14 1'x 4' Single Flange Kit FK22 2'x 2' Single Flange Kit FK24 2'× 4' Single Flange Kit 1. For hard ceilings use flange kit accessory (order separately). 2. Bi-Level driver must be controlled by sensor or A/B switching. 3. Must be used in conjunction with lighting controls. 4. Not available with surface mount. Page 1/7 - Revised: 10/31/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com RJT 1x4, 2x2, 2x4 LED Troffer PHOTOMETRIC DATA PHOTOMETRIC DATA: RJT14-40ML-XXA12-EDU All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA ENERGY DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet RJT14-40MLG-FSA12-EU RJT LED, Lensed Troffer 1' X 4' LED with A12 pattern acrylic prismed lens XI054C150V054BST1 1.00 LED 4223 39 Recessed 0° = 90 90° = 90 0° = 1.11 90° = 1.11 Length: 3.92 Width: 0.83 Height: 0.00 Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 111 Noncompliant Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet RJT22-40MLG-FSA12-EU RJT LED, Lensed Troffer 2' X 2' LED with A12 pattern acrylic prismed lens XI040C110V054BST1 1.00 LED 3419 31 Recessed 0° = 90 90° = 90 0° = 1.14 90° = 1.20 Length: 1.92 Width: 1.92 Height: 0.00 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-30 0-40 0-60 0-90 0-180 1538 2389 3623 4223 4223 36.4 56.6 85.8 100 100.0 36.4 56.6 85.8 100 100.0 Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 109 Noncompliant Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet RJT24-40MLG-FSA12-EU RJT LED, Lensed Troffer 2' X 4' LED with A12 pattern acrylic prismed lens XI040C110V054BST1 1.00 LED 4792 38 Recessed 0º = 90 90º = 90 0º = 1.19 90º = 1.19 Length: 3.81 Width: 1.80 Height: 0.00 Test: 16381 Test Date: 07/13/2016 INDOOR CANDELA PLOT $2.18 based on 3000 hrs. and $0.08 per KWH ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-30 0-40 0-60 0-90 0-180 1209 1903 2930 3419 3419 35.3 55.7 85.7 100.0 100.0 35.3 55.7 85.7 100.0 100.0 PHOTOMETRIC DATA: RJT24-35MLG-FSA12-EDU All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA ENERGY DATA Luminaire INDOOR CANDELA PLOT $2.16 based on 3000 hrs. and $0.08 per KWH PHOTOMETRIC DATA: RJT22-35MLG-FSA12-EDU All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA ENERGY DATA Luminaire Test: 16363 Test Date: 07/08/16 Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 125 Noncompliant Test: 16402 Test Date: 06/27/2016 INDOOR CANDELA PLOT $1.90 based on 3000 hrs. and $0.08 per KWH ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-30 0-40 0-60 0-90 0-180 1609 2562 4069 4792 4792 33.6 53.5 84.9 100.0 100.0 33.6 53.5 84.9 100.0 100.0 Page 2/7 - Revised: 10/31/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com RJT 1x4, 2x2, 2x4 LED Troffer LUMEN PACKAGE OPTIONS RJT14 Lumens Input Watts LPW RJT14-50XWG-FSA12-EU 2568 20 127 RJT14-40XWG-FSA12-EU 2358 20 116 RJT14-35XWG-FSA12-EU 2322 20 114 RJT14-30XWG-FSA12-EU 2255 20 111 RJT14-50VWG-FSA12-EU 3232 27 121 RJT14-40VWG-FSA12-EU 2968 27 111 RJT14-35VWG-FSA12-EU 2923 27 109 RJT14-30VWG-FSA12-EU 2838 27 106 RJT14-50MWG-FSA12-EU 3794 31 124 RJT14-40MWG-FSA12-EU 3484 31 114 RJT14-35MWG-FSA12-EU 3430 31 112 RJT14-30MWG-FSA12-EU 3331 31 109 RJT14-50LWG-FSA12-EU 4164 34 122 RJT14-40LWG-FSA12-EU 3824 34 112 RJT14-35LWG-FSA12-EU 3766 34 110 RJT14-30LWG-FSA12-EU 3656 34 107 RJT14-50MLG-FSA12-EU 4598 38 120 RJT14-40MLG-FSA12-EU 4222 38 111 RJT14-35MLG-FSA12-EU 4158 38 109 RJT14-30MLG-FSA12-EU 4037 38 106 RJT14-50HLG-FSA12-EU 5264 45 117 RJT14-40HLG-FSA12-EU 4834 45 107 RJT14-35HLG-FSA12-EU 4761 45 106 RJT14-30HLG-FSA12-EU 4622 45 102 RJT14-50VLG-FSA12-EU 7179 59 122 RJT14-40VLG-FSA12-EU 6593 59 112 RJT14-35VLG-FSA12-EU 6492 59 110 RJT14-30VLG-FSA12-EU 6303 59 107 Page 3/7 - Revised: 10/31/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com RJT 1x4, 2x2, 2x4 LED Troffer LUMEN PACKAGE OPTIONS RJT22 Lumens Input Watts LPW RJT22-50VWG-FSA12-EU 1572 13 120 RJT22-40VWG-FSA12-EU 1443 13 110 RJT22-35VWG-FSA12-EU 1421 13 108 RJT22-30VWG-FSA12-EU 1380 13 105 RJT22-50MWG-FSA12-EU 2130 18 117 RJT22-40MWG-FSA12-EU 1956 18 107 RJT22-35MWG-FSA12-EU 1926 18 106 RJT22-30MWG-FSA12-EU 1870 18 103 RJT22-50LWG-FSA12-EU 2741 24 116 RJT22-40LWG-FSA12-EU 2517 24 106 RJT22-35LWG-FSA12-EU 2479 24 105 RJT22-30LWG-FSA12-EU 2407 24 102 RJT22-50MLG-FSA12-EU 3722 31 119 RJT22-40MLG-FSA12-EU 3419 31 109 RJT22-35MLG-FSA12-EU 3365 31 108 RJT22-30MLG-FSA12-EU 3267 31 104 RJT22-50HLG-FSA12-EU 4074 33 125 RJT22-40HLG-FSA12-EU 3743 33 114 RJT22-35HLG-FSA12-EU 3684 33 113 RJT22-30HLG-FSA12-EU 3577 33 109 RJT22-50VLG-FSA12-EU 4718 42 113 RJT22-40VLG-FSA12-EU 4334 42 104 RJT22-35VLG-FSA12-EU 4265 42 103 RJT22-30VLG-FSA12-EU 4142 42 100 Page 4/7 - Revised: 10/31/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com RJT 1x4, 2x2, 2x4 LED Troffer LUMEN PACKAGE OPTIONS RJT24 Lumens Input Watts LPW RJT24-50XWG-FSA12-EU 2919 20 145 RJT24-40XWG-FSA12-EU 2681 20 133 RJT24-35XWG-FSA12-EU 2640 20 131 RJT24-30XWG-FSA12-EU 2563 20 127 RJT24-50VWG-FSA12-EU 3806 27 142 RJT24-40VWG-FSA12-EU 3495 27 130 RJT24-35VWG-FSA12-EU 3441 27 128 RJT24-30VWG-FSA12-EU 3341 27 125 RJT24-50MWG-FSA12-EU 4297 31 140 RJT24-40MWG-FSA12-EU 3946 31 129 RJT24-35MWG-FSA12-EU 3886 31 127 RJT24-30MWG-FSA12-EU 3772 31 123 RJT24-50LWG-FSA12-EU 4720 34 139 RJT24-40LWG-FSA12-EU 4334 34 127 RJT24-35LWG-FSA12-EU 4268 34 126 RJT24-30LWG-FSA12-EU 4144 34 122 RJT24-50MLG-FSA12-EU 5218 38 136 RJT24-40MLG-FSA12-EU 4792 38 125 RJT24-35MLG-FSA12-EU 4718 38 123 RJT24-30MLG-FSA12-EU 4581 38 119 RJT24-50HLG-FSA12-EU 6017 45 133 RJT24-40HLG-FSA12-EU 5526 45 122 RJT24-35HLG-FSA12-EU 5441 45 120 RJT24-30HLG-FSA12-EU 5286 45 117 RJT24-50VLG-FSA12-EU 8191 59 138 RJT24-40VLG-FSA12-EU 7522 59 127 RJT24-35VLG-FSA12-EU 7407 59 125 RJT24-30VLG-FSA12-EU 7192 59 121 RJT24-50XLG-FSA12-EU 9763 73 134 RJT24-40XLG-FSA12-EU 8966 73 123 RJT24-35XLG-FSA12-EU 8829 73 121 RJT24-30XLG-FSA12-EU 8571 73 117 *Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards. Page 5/7 - Revised: 10/31/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com RJT 1x4, 2x2, 2x4 LED Troffer FIXTURE DIMENSIONS 1X4 CROSS SECTION 1/2" 225⁄8" 1X4 TOP VIEW 225⁄8" 15" 13/16" 15" 1/4" Ø 4.8125" 33⁄4" 33⁄4" 12" 481⁄16" 2X4 CROSS SECTION 2X2 CROSS SECTION 3.125" 4.250" 24" 24" 2X4 TOP VIEW 2X2 TOP VIEW 48" 4.500" A 24" 3" K A- 7/8" Diameter Knockout K- 2"x 3" through hole for access plate 3" 3.15625" 3.09375" A 4.250" K 16.500" A- 7/8" Diameter Knockout K- 2"x 3" through hole for access plate *Drawings N.T.S. Page 6/7 - Revised: 10/31/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com RJT 1x4, 2x2, 2x4 LED Troffer SURFACE MOUNT DIMENSIONS 1X4 DIMENSIONS 43" 2.875" 7/8" Feed KO 2.875" A A 5.25" A 9.5" 2X4 DIMENSIONS 2X2 DIMENSIONS 44.625" Mounting Holes: (4) 1/4"-1/2" DIA KOs 4.750" 12.375" 5.5625" 21.625" Mounting Holes: (4) 1/4"-1/2" DIA KOs 12.375" 14" 1 ½" Thru Hole 4 1/2" x 5" Mounting Collar (SM). 12.375" 15" 1 ½" Thru Hole 4 1/2" x 5" Mounting Collar (SM). 5" *Drawings N.T.S. CEILING COMPATIBILITY TYPE G FLANGE KIT End Side For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed. End Side For hard ceiling applications order flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. *Drawings N.T.S. Page 7/7 - Revised: 10/31/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
© Copyright 2025 Paperzz