Proximity sensors SIE…, inductive

Proximity sensors SIE…, inductive
q/w
Festo core product range
Covers 80% of your automation tasks
Worldwide:
Superb:
Easy:
Always in stock
Festo quality at an attractive price
Reduces procurement and storing complexity
qReady for dispatch from the Festo factory in 24 hours
Held in stock in 13 service centres worldwide
More than 2200 products
wReady for dispatch in 5 days maximum from stock
Assembled for you in 4 service centres worldwide
Up to 6 x 1012 variants per product series
Look for the star!
Proximity sensors SIE…, inductive
Product range overview
Version
Type
Reduction factor, material-specific
Standard switching
SIEN
distance
Basic version
SIEN-…-PA
Polyamide housing
SIED
Basic version
SIED-…-PA
Polyamide housing
SIES
Special design
Increased switching
SIEH
distance
Basic version
SIEH-…-CR
Stainless steel
housing
Analogue output
SIEA
Operating voltage
Switching output/
analogue output
Mounting type
Size
è Page/
Internet
10 … 30 V DC
15 … 34 V DC
10 … 30 V DC
PNP
NPN
PNP
NPN
Contactless, 2-wire
Flush
Non-flush
Flush
Non-flush
Flush
Non-flush
Flush
Non-flush
Flush
 4 mm, M5,  6.5 mm,
M8, M12, M18, M30
M12, M18, M30
5
M12, M18, M30
17
M12, M18, M30
23
26
Flush
5x5x25 mm …
40x40x120 mm
 3 mm, M12, M18
Flush
M12, M18
35
0 … 10 V and
4 … 20 mA
Flush
M8, M12, M18, M30
39
PNP
NPN
PNP
NPN
Flush
Partially flush
Flush
Partially flush
M8, M12, M18, M30
40x40x65 mm
M12, M18, M30
43
20 … 265 V AC
20 … 320 V DC
20 … 250 V AC
10 … 300 V DC
10 … 30 V DC
10 … 30 V DC
15 … 34 V DC
10 … 30 V DC
15 … 30 V DC
Reduction factor 1 for all metals, welding field immune
Increased switching
SIEF
10 … 65 V DC
distance
Basic version
SIEF-…-WA
10 … 30 V DC
Housing resistant
to welding spatter
2
Contactless, 2-wire
PNP
NPN
PNP
NPN
PNP
NPN
è Internet: www.festo.com/catalogue/...
13
31
49
Subject to change – 2017/05
Proximity sensors SIE…, inductive
Peripherals overview
SIE…
SIES-V3B
5
1
1
4
2
2
7
3
6
Mounting attachments and accessories
è Page/
Internet
Mounting attachments and accessories
è Page/
Internet
1
53
–
53
53
–
53
–
53
–
2
3
4
5
6
7
Connecting cable, straight socket
NEBU-M…G…
Connecting cable, angled socket
NEBU-M…W…
Sensor bracket
SIEZ-…B
Sensor bracket
SIEZ-UV
Sensor bracket
SIEZ-UH
Inscription label
SIEZ-LB
Mounting bracket
HV-M5
2017/05 – Subject to change
Foot mounting
HBN
Foot mounting
HBE
Flange mounting
FBN
Stop for proximity
SDA
53
53
53
53
53
53
è Internet: www.festo.com/catalogue/...
3
Proximity sensors SIE…, inductive
Type codes
SIE
N
–
M
30
NB
–
P
S
–
K
–
L
–
Type
SIE
Proximity sensor, inductive
Type
A
D
F
H
N
S
With analogue output
For DC and AC voltage
With reduction factor 1 for all metals, welding field immune
With increased switching distance
With standard switching distance
Special design
Design
–
M
Q
V3
Round
Metric thread
Block-shaped
Block-shaped
Size
Mounting type
B
NB
S
Flush
Non-flush
Partially flush
Electrical output
P
N
Z
PU
UI
Switching output PNP
Switching output NPN
2-wire output
Analogue output 0 … 10 V
Analogue output 0 … 10 V and 4 … 20 mA
Switching element function
S
O
A
N/O contact
N/C contact
Antivalent
Electrical connection
K
S
X
Cable
Plug
Screw terminals
Display
–
L
2L
Without display
Switching status
Switching status and ready status
Version
–
CR
PA
WA
4
Standard
Stainless steel housing
Polyamide housing
Housing resistant to welding spatter
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEN, inductive
Technical data – Standard switching distance, basic version
Standard switching distance
For DC voltage
Round design
Function1)
1)
e.g. N/O contact with PNP output and cable
General technical data
Size
4 mm
Conforms to
Certification
CE mark (see declaration of conformity)
Note on materials
1)
M5
6.5 mm
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
Free of copper and PTFE
RoHS-compliant
–
M8
M12
M18
M30
Contains PWIS (paint-wetting impairment substances)
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp è Certificates.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
Input signal/measuring element
Size
Ambient temperature
4 mm
[°C]
Output, general
Mounting type
Size
Repetition accuracy
[mm]
Switching output
Mounting type
Size
Switching output
Switching element function
Rated operating distance
Assured switching distance
[mm]
[mm]
Reduction factors
Aluminium
Stainless steel St 18/8
Copper
Brass
Steel St 37
Hysteresis
Max. switching frequency
Max. output current
Voltage drop
2017/05 – Subject to change
[mm]
[Hz]
[mA]
[V]
M5
6.5 mm
M8
M12
M18
M30
–25 … +70
Flush
4 mm
M5
6.5 mm
M8
M12
M18
M30
Non-flush
M8
M12
M18
M30
0.04
0.04
0.07
0.07
0.1
0.25
0.5
0.12
0.4
0.75
Flush
4 mm
M5
6.5 mm
M8
M12
M18
M30
Non-flush
M8
M12
M18
M30
8
6.48
15
12.15
0.2
PNP
NPN
N/O contact
N/C contact
0.8
0.8
0.64
0.64
1.5
1.21
1.5
1.21
2
1.62
5
4.05
10
8.1
PNP
NPN
N/O contact
N/C contact
2.5
4
2.03
3.24
0.4
0.7
0.3
0.4
1.0
0.4
0.7
0.3
0.4
1.0
0.25
0.7
0.2
0.35
1.0
0.25
0.7
0.2
0.35
1.0
0.4
0.6
0.3
0.5
1.0
0.4
0.8
0.4
0.5
1.0
0.45
0.8
0.4
0.55
1.0
0.25
0.7
0.2
0.35
1.0
0.5
0.9
0.5
0.6
1.0
0.5
0.8
0.4
0.5
1.0
0.5
0.85
0.43
0.53
1.0
–
3,000
200
0…2
–
3,000
 0.07
5,000
 0.07
5,000
 0.18
3,000
 0.55
2,000
 1.1
1,200
 0.12
3,000
 0.36
2,000
 0.88
2,000
 1.65
700
è Internet: www.festo.com/catalogue/...
5
Proximity sensors SIEN, inductive
Technical data – Standard switching distance, basic version
Output, additional data
Size
4 mm
Protection against short circuit
Inductive protective circuit
Induced voltage protection
Pulsed
Integrated
Integrated
Electronic components
Size
Operating voltage range
Residual ripple
Idle current
Reverse polarity protection
M5
Plug
Electrical connection
4 mm
Attachment type
Mounting type
M18
M30
M8
M12
M18
M30
±10
±20
6.5 mm
M8
M12
M18
M30
Plug, M8x1,
3-pin
Plug, M8x1,
3-pin
Plug, M8x1,
3-pin
Plug, M12x1,
3-pin
Plug, M12x1,
3-pin
Plug, M12x1,
3-pin
M5
6.5 mm
M8
M12
Clamped Via lock
nut
Flush
Clamped Via lock nut
–
–
Cable
Product weight
Housing material
[g]
48
48
45
High-alloy stainless steel
–
2
Flush
[Nm]
[g]
M12
M5
Tightening torque
Plug
Product weight
Housing material
M8
Cable, 3-wire
2.5
TPE-U (PUR)
Plug, M8x1,
3-pin
Mechanical components
Size
6.5 mm
10 … 30
10
0 … 10
For all electrical connections
4 mm
[m]
6.5 mm
–
4 mm
[V DC]
[%]
[mA]
Electromechanical components
Size
Cable
Electrical connection
Cable length
Cable sheath material
M5
PA
–
Nonflush
–
53
–
53
Nonflush
Flush
M30
Nonflush
20
Flush
Nonflush
40
110
90
108
Nickel-plated brass
105
155
150
Chrome-plated
brass
30
25
43
–
Nickel-plated brass
40
100
–
PBTP
9
9
4
18
18
High-alloy stainless steel
–
–
Chrome-plated brass
PA
–
Flush
M18
100
Chrome-plated
brass
PBTP
Display/operation
Switching status display
6
Yellow LED
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEN, inductive
Technical data – Standard switching distance, basic version
Immissions/emissions
Size
4 mm
M5
6.5 mm
Ambient temperature with flexible
cable installation
Protection class
[°C]
–
–5 … +70
–5 … +70
–5 … +70
Surge strength
Corrosion resistance class CRC1)
Degree of contamination
[kV]
–
IP67
–
–
–
1
4
3
IP65
IP67
–
2
–
–
IP67
0.8
–
3
1)
M8
M12
M18
M30
Corrosion resistance class CRC 2 to Festo standard FN 940070
Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­
sphere typical for industrial applications.
Corrosion resistance class CRC 4 to Festo standard FN 940070
Particularly high corrosion stress. Outdoor exposure under extreme corrosive conditions. Parts exposed to aggressive media, for instance in the chemical or food industries. These applications may need to be suppor­
ted by special tests (è also FN 940082) using appropriate media.
Pin allocation to EN 60947-5-2
M8x1, 3-pin
N/O contact and N/C contact
Pin
Wire colour Allocation
1
3
4
Brown
Blue
Black
M12x1, 3-pin
N/O contact
Pin
+
–
Output
1
3
4
N/C contact
Wire colour Allocation
Pin
Wire colour Allocation
Brown
Blue
Black
1
3
2
Brown
Blue
White
+
–
Output
+
–
Output
Download CAD data è www.festo.com
Dimensions – 4 mm
Flush fitting
Cable SIEN-…-K-L
Plug SIEN-…-S-L
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status displays,
yellow
Type
D1

D2

D2
D3

L1
L2
L3
SIEN-M4B-…-K-L
SIEN-M4B-…-S-L
4
4
3.5
–
–
M8x1
–
6.5
25
38
–
21
18
–
2017/05 – Subject to change
è Internet: www.festo.com/catalogue/...
7
Proximity sensors SIEN, inductive
Technical data – Standard switching distance, basic version
Download CAD data è www.festo.com
Dimensions – M5
Flush fitting
Cable SIEN-…-K-L
Plug SIEN-…-S-L
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status displays,
yellow
Type
B1
D1
D2

D2
D3

L1
L2
L3
ß1
SIEN-M5B-…-K-L
SIEN-M5B-…-S-L
2.5
–
M5x0.5
M5x0.5
3.5
–
–
M8x1
–
6.5
25
38
20
23
18
–
7
6.5
Download CAD data è www.festo.com
Dimensions – 6.5 mm
Flush fitting
Cable SIEN-…-K-L
Plug SIEN-…-S-L
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status displays,
yellow
Type
D1

D2

D2
L1
L2
SIEN-M6,5B-…-K-L
SIEN-M6,5B-…-S-L
6.5
6.5
3.5
–
–
M8x1
35
45
–
36
Download CAD data è www.festo.com
Dimensions – M8
Flush fitting
Cable SIEN-…-K-L
Non-flush fitting
Cable SIEN-M8NB-…-K-L
Plug SIEN-…-S-L
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status displays,
yellow
Plug SIEN-M8NB-…-S-L
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status displays,
yellow
Type
B1
D1
D2

D2
L1
L5
L8
L9
ß1
SIEN-M8B-…-K-L
SIEN-M8B-…-S-L
SIEN-M8NB-…-K-L
SIEN-M8NB-…-S-L
4
4
4
4
M8x1
M8x1
M8x1
M8x1
3.5
–
3.5
–
–
M8x1
–
M8x1
35
45
35
45
–
7
–
–
–
–
4
4
–
32
–
27.5
13
13
13
13
8
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEN, inductive
Technical data – Standard switching distance, basic version
Download CAD data è www.festo.com
Dimensions – M12
Flush fitting
Cable SIEN-…-K-L
Non-flush fitting
Cable SIEN-M12NB-…-K-L
Plug SIEN-…-S-L
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status displays,
yellow
Plug SIEN-M12NB-…-S-L
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status displays,
yellow
Type
B1
D1
D2

D2
D3

L1
L5
L6
L7
L8
ß1
SIEN-M12B-…-K-L
SIEN-M12B-…-S-L
SIEN-M12NB-…-K-L
SIEN-M12NB-…-S-L
4
4
4
4
M12x1
M12x1
M12x1
M12x1
5
–
5
–
–
M12x1
–
M12x1
–
–
–
10.5
35
45
35
45
–
11
–
11
–
5
–
5
–
3.3
–
3.3
–
–
5.7
5.7
17
17
17
17
Download CAD data è www.festo.com
Dimensions – M18
Flush fitting
Cable SIEN-…-K-L
Non-flush fitting
Cable SIEN-M18NB-…-K-L
Plug SIEN-…-S-L
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status displays,
yellow
Plug SIEN-M18NB-…-S-L
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status displays,
yellow
Type
B1
D1
D2

D2
D3

L1
L4
L5
L6
L7
L8
ß1
SIEN-M18B-…-K-L
SIEN-M18B-…-S-L
SIEN-M18NB-…-K-L
SIEN-M18NB-…-S-L
4
4
4
4
M18x1
M18x1
M18x1
M18x1
5
–
5
–
–
M12x1
–
M12x1
–
16.4
–
16.4
35
48.5
35
48.5
–
13.5
–
13.5
–
11
–
11
–
8
–
8
–
3
–
3
–
–
10
10
24
24
24
24
2017/05 – Subject to change
è Internet: www.festo.com/catalogue/...
9
Proximity sensors SIEN, inductive
Technical data – Standard switching distance, basic version
Download CAD data è www.festo.com
Dimensions – M30
Flush fitting
Cable SIEN-…-K-L
Non-flush fitting
Cable SIEN-M30NB-…-K-L
Plug SIEN-…-S-L
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status displays,
yellow
Plug SIEN-M30NB-…-S-L
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status displays,
yellow
Type
B1
D1
D2

D2
L1
L4
L5
L6
L8
ß1
SIEN-M30B-…-K-L
SIEN-M30B-…-S-L
SIEN-M30NB-…-K-L
SIEN-M30NB-…-S-L
5
5
5
5
M30x1.5
M30x1.5
M30x1.5
M30x1.5
5
–
5
–
–
M12x1
–
M12x1
35
48.5
35
48.5
–
13.5
–
13.5
–
11
–
11
–
8
–
8
–
–
10
10
36
36
36
36
Fitting instructions
Flush fitting
Non-flush fitting
2 Active surface
5 Metal-free zone
2 Active surface
5 Metal-free zone
Size
B1
B2
H
Size
B1
B2
H1
H2
4 mm
M5
6.5 mm
M8
M12
M18
M30
2.5
3.3
5
5.5
8
14
25
5
5
9.5
10
18
32
60
2
2.4
4.5
4.5
6
15
30
M8
M12
M18
M30
9
12
20
30
16
28
50
75
8
6
10
15
7.5
12
24
45
10
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEN, inductive
Technical data – Standard switching distance, basic version
qCore product range
Ordering data
Size
Sn1)
Mounting Switching Switching
type
output
element function
[mm]
Electrical connection
Cable
Part No.
Type
Plug
Part No.
Type
M5
0.8
Flush
PNP
NPN
N/O contact
N/O contact
q150370
q150368
SIEN-M5B-PS-K-L
SIEN-M5B-NS-K-L
q150371
q150369
SIEN-M5B-PS-S-L
SIEN-M5B-NS-S-L
1.5
Flush
PNP
NPN
N/O contact
N/O contact
q150386
q150384
SIEN-M8B-PS-K-L
SIEN-M8B-NS-K-L
q150387
q150385
SIEN-M8B-PS-S-L
SIEN-M8B-NS-S-L
M8
1)
Sn Rated operating distance [mm]
Ordering data
Size
Sn1)
Mounting Switching Switching
type
output
element function
Electrical connection
Cable
Part No.
Type
Plug
Part No.
Type
N/O contact
N/C contact
N/O contact
N/C contact
150362
150366
150360
150364
SIEN-4B-PS-K-L
SIEN-4B-PO-K-L
SIEN-4B-NS-K-L
SIEN-4B-NO-K-L
150363
150367
150361
150365
SIEN-4B-PS-S-L
SIEN-4B-PO-S-L
SIEN-4B-NS-S-L
SIEN-4B-NO-S-L
[mm]
4 mm
0.8
Flush
PNP
NPN
M5
0.8
Flush
PNP
NPN
N/C contact
N/C contact
150374
150372
SIEN-M5B-PO-K-L
SIEN-M5B-NO-K-L
150375
150373
SIEN-M5B-PO-S-L
SIEN-M5B-NO-S-L
1.5
Flush
PNP
N/O contact
N/C contact
N/O contact
N/C contact
150378
150382
150376
150380
SIEN-6,5B-PS-K-L
SIEN-6,5B-PO-K-L
SIEN-6,5B-NS-K-L
SIEN-6,5B-NO-K-L
150379
150383
150377
150381
SIEN-6,5B-PS-S-L
SIEN-6,5B-PO-S-L
SIEN-6,5B-NS-S-L
SIEN-6,5B-NO-S-L
N/C contact
N/C contact
N/O contact
N/C contact
N/O contact
N/C contact
150390
150388
150394
150398
150392
150396
SIEN-M8B-PO-K-L
SIEN-M8B-NO-K-L
SIEN-M8NB-PS-K-L
SIEN-M8NB-PO-K-L
SIEN-M8NB-NS-K-L
SIEN-M8NB-NO-K-L
150391
150389
150395
150399
150393
150397
SIEN-M8B-PO-S-L
SIEN-M8B-NO-S-L
SIEN-M8NB-PS-S-L
SIEN-M8NB-PO-S-L
SIEN-M8NB-NS-S-L
SIEN-M8NB-NO-S-L
6.5 mm
NPN
M8
1.5
2.5
Flush
PNP
NPN
Non-flush PNP
NPN
1)
Sn Rated operating distance [mm]
Festo core product range
2017/05 – Subject to change
qReady for dispatch from the Festo factory in 24 hours
wReady for dispatch in 5 days maximum from stock
è Internet: www.festo.com/catalogue/...
11
Proximity sensors SIEN, inductive
Technical data – Standard switching distance, basic version
Ordering data
Size
Sn1)
Mounting
type
Switching
output
[mm]
Switching
Electrical connection
element function Cable
Part No.
Type
Plug
Part No.
Type
N/O contact
N/C contact
N/O contact
N/C contact
N/O contact
N/C contact
N/O contact
N/C contact
150402
150406
150400
150404
150410
150414
150408
150412
SIEN-M12B-PS-K-L
SIEN-M12B-PO-K-L
SIEN-M12B-NS-K-L
SIEN-M12B-NO-K-L
SIEN-M12NB-PS-K-L
SIEN-M12NB-PO-K-L
SIEN-M12NB-NS-K-L
SIEN-M12NB-NO-K-L
150403
150407
150401
150405
150411
150415
150409
150413
SIEN-M12B-PS-S-L
SIEN-M12B-PO-S-L
SIEN-M12B-NS-S-L
SIEN-M12B-NO-S-L
SIEN-M12NB-PS-S-L
SIEN-M12NB-PO-S-L
SIEN-M12NB-NS-S-L
SIEN-M12NB-NO-S-L
N/O contact
N/C contact
N/O contact
N/C contact
N/O contact
N/C contact
N/O contact
N/C contact
150418
150422
150416
150420
150426
150430
150424
150428
SIEN-M18B-PS-K-L
SIEN-M18B-PO-K-L
SIEN-M18B-NS-K-L
SIEN-M18B-NO-K-L
SIEN-M18NB-PS-K-L
SIEN-M18NB-PO-K-L
SIEN-M18NB-NS-K-L
SIEN-M18NB-NO-K-L
150419
150423
150417
150421
150427
150431
150425
150429
SIEN-M18B-PS-S-L
SIEN-M18B-PO-S-L
SIEN-M18B-NS-S-L
SIEN-M18B-NO-S-L
SIEN-M18NB-PS-S-L
SIEN-M18NB-PO-S-L
SIEN-M18NB-NS-S-L
SIEN-M18NB-NO-S-L
N/O contact
N/C contact
N/O contact
N/C contact
N/O contact
N/C contact
N/O contact
N/C contact
150434
150438
150432
150436
150442
150446
150440
150444
SIEN-M30B-PS-K-L
SIEN-M30B-PO-K-L
SIEN-M30B-NS-K-L
SIEN-M30B-NO-K-L
SIEN-M30NB-PS-K-L
SIEN-M30NB-PO-K-L
SIEN-M30NB-NS-K-L
SIEN-M30NB-NO-K-L
150435
150439
150433
150437
150443
150447
150441
150445
SIEN-M30B-PS-S-L
SIEN-M30B-PO-S-L
SIEN-M30B-NS-S-L
SIEN-M30B-NO-S-L
SIEN-M30NB-PS-S-L
SIEN-M30NB-PO-S-L
SIEN-M30NB-NS-S-L
SIEN-M30NB-NO-S-L
M12
2.0
Flush
PNP
NPN
4.0
Non-flush
PNP
NPN
M18
5.0
Flush
PNP
NPN
8.0
Non-flush
PNP
NPN
M30
10.0
Flush
PNP
NPN
15.0
Non-flush
PNP
NPN
1)
12
Sn Rated operating distance [mm]
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEN-…-PA, inductive
Technical data – Standard switching distance, polyamide housing
Function1)
1)
Standard switching distance
Corrosion-resistant
Polyamide housing
For DC voltage
Round design
e.g. N/O contact with PNP output and cable
General technical data
Design
Conforms to
Certification
CE mark (see declaration of conformity)
Note on materials
1)
Round
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
Free of copper and PTFE
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp è Certificates.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
Input signal/measuring element
Ambient temperature
[°C]
Output, general
Mounting type
Size
Repetition accuracy
[mm]
Switching output
Mounting type
Size
Switching output
Switching element function
Rated operating distance
Assured switching distance
[mm]
[mm]
Reduction factors
Aluminium
Stainless steel St 18/8
Copper
Brass
Steel St 37
Hysteresis
Max. switching frequency DC
Max. output current
Voltage drop
–25 … +70
Flush
M12
M18
M30
Non-flush
M12
M18
M30
0.04
0.1
0.2
0.08
0.16
0.3
Flush
M12
M18
M30
Non-flush
M12
M18
M30
10
8.1
PNP
NPN
N/O contact
4
3.24
8
6.48
15
12.15
0.24 … 1.2
1,000
0.45 … 2.25
500
PNP
NPN
N/O contact
2
1.62
5
4.05
0.35 … 0.5
0.6 … 1.0
0.25 … 0.45
0.35 … 0.5
1.0
[mm]
[Hz]
[mA]
[V]
0.06 … 0.3
2,000
200
 1.8
0.35 … 0.5
0.6 … 1.0
0.25 … 0.45
0.35 … 0.5
1.0
0.15 … 0.75
1,000
0.3 … 1.5
500
0.12 … 0.6
2,000
200
 1.8
Output, additional data
Protection against short circuit
2017/05 – Subject to change
Pulsed
è Internet: www.festo.com/catalogue/...
13
Proximity sensors SIEN-…-PA, inductive
Technical data – Standard switching distance, polyamide housing
Electronic components
Operating voltage range
Residual ripple
Idle current
Reverse polarity protection
[V DC]
[%]
[mA]
10 … 30
10
 15
For all electrical connections
Electromechanical components
Electrical connection
Cable length
Cable sheath material
Insulating sheath material
[m]
Cable, 3-wire
2.5
PVC
PVC
Mechanical components
Size
M12
Attachment type
Mounting type
Tightening torque
Product weight
Housing material
Via lock nut
Flush
–
41
PA-reinforced
[Nm]
[g]
M18
M30
Non-flush
25
38
Flush
–
124
Non-flush
25
141
Flush
15
48
Non-flush
15
48
M18
M30
Non-flush
M12
M18
M30
Display/operation
Switching status display
Yellow LED
Immissions/emissions
Mounting type
Size
Flush
M12
Ambient temperature with flexible
cable installation
Protection class
Corrosion resistance class CRC1)
1)
14
[°C]
0 … +70
0 … +70
IP65
IP67
4
IP67
4
Corrosion resistance class CRC 4 to Festo standard FN 940070
Particularly high corrosion stress. Outdoor exposure under extreme corrosive conditions. Parts exposed to aggressive media, for instance in the chemical or food industries. These applications may need to be suppor­
ted by special tests (è also FN 940082) using appropriate media.
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEN-…-PA, inductive
Technical data – Standard switching distance, polyamide housing
Download CAD data è www.festo.com
Dimensions
M12
1 3-core cable, 2.5 m
2 Active surface
M18
3 1 switching status display,
yellow
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
Type
B1
D1
D2

L1
L2
L10
ß1
SIEN-M12-…-B-…-K-L-PA
SIEN-M18-…-B-…-K-L-PA
8
8.2
M12x1
M18x1
5
5.2
60
60
40
50
4
4
17
24
Download CAD data è www.festo.com
Dimensions
M30
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
Type
B1
D1
D2

L1
L2
L10
ß1
SIEN-M30-…-B-…-K-L-PA
10
M30x1.5
5
60
50
4
36
2017/05 – Subject to change
è Internet: www.festo.com/catalogue/...
15
Proximity sensors SIEN-…-PA, inductive
Technical data – Standard switching distance, polyamide housing
Fitting instructions
Flush fitting
Non-flush fitting
2 Active surface
5 Metal-free zone
2 Active surface
5 Metal-free zone
Size
B1
B2
H
Size
B1
B2
H1
H2
M12
M18
M30
18
27
45
24
36
60
6
15
30
M12
M18
M30
18
27
45
36
54
90
8
16
30
12
24
45
Ordering data
Size
Sn1)
Mounting type
Switching output
Switching element
function
Electrical connection
Cable
Part No.
Type
2.0
Flush
N/O contact
4.0
Non-flush
PNP
NPN
PNP
NPN
538323
538324
538329
538330
SIEN-M12B-PS-K-L-PA
SIEN-M12B-NS-K-L-PA
SIEN-M12NB-PS-K-L-PA
SIEN-M12NB-NS-K-L-PA
5.0
Flush
N/O contact
8.0
Non-flush
PNP
NPN
PNP
NPN
538325
538326
538331
538332
SIEN-M18B-PS-K-L-PA
SIEN-M18B-NS-K-L-PA
SIEN-M18NB-PS-K-L-PA
SIEN-M18NB-NS-K-L-PA
10.0
Flush
N/O contact
15.0
Non-flush
PNP
NPN
PNP
NPN
538327
538328
538333
538334
SIEN-M30B-PS-K-L-PA
SIEN-M30B-NS-K-L-PA
SIEN-M30NB-PS-K-L-PA
SIEN-M30NB-NS-K-L-PA
[mm]
M12
M18
M30
1)
16
Sn Rated operating distance [mm]
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIED, inductive
Technical data – Standard switching distance, for DC and AC voltage
Standard switching distance
For DC and AC voltage
Round design
Function1)
1)
e.g. N/O contact with cable
General technical data
Design
Conforms to
Certification
CE mark (see declaration of conformity)
Note on materials
1)
Round
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
To EU Low Voltage Directive
Free of copper and PTFE
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp è Certificates.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
Input signal/measuring element
Ambient temperature
[°C]
Output, general
Mounting type
Size
Repetition accuracy
[mm]
Switching output
Mounting type
Size
Switching output
Switching element function
Rated operating distance
Assured switching distance
[mm]
[mm]
Reduction factors
Aluminium
Stainless steel St 18/8
Copper
Brass
Steel St 37
Hysteresis
Max. switching frequency AC
Max. switching frequency DC
Max. output current
Minimum load current
Voltage drop
2017/05 – Subject to change
[mm]
[Hz]
[Hz]
[mA]
[mA]
[V]
–25 … +85
Flush
M12
M18
M30
Non-flush
M12
M18
M30
0.1
0.15
0.3
0.2
0.2
0.4
Flush
M12
M18
M30
Non-flush
M12
M18
M30
Contactless, 2-wire
N/O contact
N/C contact
2
5
1.62
4.05
10
8.1
Contactless, 2-wire
N/O contact
N/C contact
4
8
3.24
6.5
15
12.5
0.5
0.9
0.4
0.6
1.0
0.4
0.7
0.3
0.4
1.0
0.4
0.7
0.3
0.4
1.0
0.6
0.9
0.5
0.6
1.0
0.4
0.7
0.3
0.4
1.0
0.5
0.8
0.4
0.5
1.0
0.02 … 0.44
25
1,200
200
5
8
0.04 … 1.15
0.05 … 2.2
0.03 … 1.9
0.04 … 3.3
490
300
200
300
0.03 … 0.88
25
900
200
5
8
340
300
220
300
è Internet: www.festo.com/catalogue/...
17
Proximity sensors SIED, inductive
Technical data – Standard switching distance, for DC and AC voltage
Output, additional data
Protection against short circuit
No
Electronic components
Operating voltage range AC
Operating voltage range DC
Idle current
Reverse polarity protection
[V AC]
[V DC]
[mA]
20 … 265
20 … 320
 1.5
For all electrical connections
Electromechanical components
Electrical connection
Cable
Plug
Electrical connection
Cable length
Cable sheath material
Insulating sheath material
Cable, 2-wire
2.5
TPE-U (PUR)
PVC
Plug, M12x1, 2-pin
–
[m]
Mechanical components
Size
Electrical connection
M12
Cable
Attachment type
Mounting type
Tightening torque
Product weight
Housing materials
[Nm]
[g]
Plug
Via lock nut
Flush
Non-flush
10
90
20
Nickel-plated brass, PA
M18
Cable
M30
Cable
Plug
Via lock nut
Flush
Non-flush
20
110
50
Nickel-plated brass, PA
Plug
Via lock nut
Flush
Non-flush
40
190
140
Nickel-plated brass, PA
Display/operation
Switching status display
Yellow LED
Immissions/emissions
Electrical connection
Cable
Plug
–5 … +50
–
IP67
1
IP67
1
Ambient temperature with flexible
cable installation
Protection class
Corrosion resistance class CRC1)
1)
Corrosion resistance class CRC 1 to Festo standard FN 940070
Low corrosion stress. For dry indoor applications or transport and storage protection. Also applies to parts behind covers, in the non-visible interior area, and parts which are covered in the application (e.g. drive
trunnions).
Pin allocation to EN 60947-5-2
M12x1, 2-pin
N/O contact
Pin
3
4
18
[°C]
Wire colour
Allocation
Black
Black
/+/–
/–/+
è Internet: www.festo.com/catalogue/...
N/C contact
M12x1
Pin
Wire colour
Allocation
1
2
Black
Black
/+/–
/–/+
Subject to change – 2017/05
Proximity sensors SIED, inductive
Technical data – Standard switching distance, for DC and AC voltage
Download CAD data è www.festo.com
Dimensions – M12
Flush fitting
Cable
Plug
1 2-core cable, 2.5 m
2 Active surface
Type
3 1 switching status display,
yellow
2 Active surface
B1
-0.3
D1
D2 
_0.15
L1
L3
ß1
4
4
M12x1
M12x1
4.5
–
56
65
41
44.5
17
17
SIED-M12B-Z-…-K-L
SIED-M12B-Z-…-S-L
Non-flush fitting
Cable
Plug
1 2-core cable, 2.5 m
2 Active surface
Type
SIED-M12NB-Z-…-K-L
SIED-M12NB-Z-…-S-L
2017/05 – Subject to change
3 1 switching status display,
yellow
3 1 switching status display,
yellow
2 Active surface
3 1 switching status display,
yellow
B1
-0.3
D1
D2 
_0.15
L1
L3
L8
ß1
4
4
M12x1
M12x1
4.5
–
62
71
47
50.5
6.5
6.5
17
17
è Internet: www.festo.com/catalogue/...
19
Proximity sensors SIED, inductive
Technical data – Standard switching distance, for DC and AC voltage
Download CAD data è www.festo.com
Dimensions – M18
Flush fitting
Cable
Plug
1 2-core cable, 2.5 m
2 Active surface
Type
3 1 switching status display,
yellow
2 Active surface
B1
-0.3
D1
D2 
_0.15
L1
L3
ß1
4
4
M18x1
M18x1
4.5
–
54
68.5
42
42
24
24
SIED-M18B-Z-…-K-L
SIED-M18B-Z-…-S-L
Non-flush fitting
Cable
Plug
1 2-core cable, 2.5 m
2 Active surface
Type
SIED-M18NB-Z-…-K-L
SIED-M18NB-Z-…-S-L
20
3 1 switching status display,
yellow
3 1 switching status display,
yellow
2 Active surface
3 1 switching status display,
yellow
B1
-0.3
D1
D2 
_0.15
L1
L3
L8
ß1
4
4
M18x1
M18x1
4.5
–
54
68.5
42
42
10.5
10.5
24
24
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIED, inductive
Technical data – Standard switching distance, for DC and AC voltage
Dimensions – M30
Flush fitting
Cable
1 2-core cable, 2.5 m
2 Active surface
Download CAD data è www.festo.com
Type
SIED-M30B-Z-…-K-L
SIED-M30B-Z-…-S-L
SIED-M30NB-Z-…-K-L
SIED-M30NB-Z-…-S-L
Plug
Non-flush fitting
Cable
Plug
3 1 switching status display,
yellow
1 2-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
B1
-0.3
D1
D2 
_0.15
L1
L3
L8
ß1
5
5
5
5
M30x1.5
M30x1.5
M30x1.5
M30x1.5
4.5
–
4.5
–
54
68.5
54
68.5
42
42
42
42
–
–
15.5
15.5
36
36
36
36
Fitting instructions
Flush fitting
Non-flush fitting
2 Active surface
5 Metal-free zone
2 Active surface
5 Metal-free zone
Size
B1
B2
H
Size
B1
B2
H1
H2
M12
M18
M30
6
11
25
12
30
37
6
10
16
M12
M18
M30
15
20
30
27
50
80
8
15
15
8
15
25
2017/05 – Subject to change
è Internet: www.festo.com/catalogue/...
21
Proximity sensors SIED, inductive
Technical data – Standard switching distance, for DC and AC voltage
Ordering data
Size
Sn1)
Mounting
type
[mm]
Switching
output
Switching
Electrical connection
element function Cable
Part No.
Type
Plug
Part No.
Type
M12
2.0
Flush
Contactless, N/O contact
2-wire
N/C contact
538272
538274
SIED-M12B-ZS-K-L
SIED-M12B-ZO-K-L
538271
538273
SIED-M12B-ZS-S-L
SIED-M12B-ZO-S-L
4.0
Non-flush
Contactless, N/O contact
2-wire
N/C contact
538268
538270
SIED-M12NB-ZS-K-L
SIED-M12NB-ZO-K-L
538267
538269
SIED-M12NB-ZS-S-L
SIED-M12NB-ZO-S-L
5.0
Flush
Contactless, N/O contact
2-wire
N/C contact
538280
538282
SIED-M18B-ZS-K-L
SIED-M18B-ZO-K-L
538279
538281
SIED-M18B-ZS-S-L
SIED-M18B-ZO-S-L
8.0
Non-flush
Contactless, N/O contact
2-wire
N/C contact
538276
538278
SIED-M18NB-ZS-K-L
SIED-M18NB-ZO-K-L
538275
538277
SIED-M18NB-ZS-S-L
SIED-M18NB-ZO-S-L
10.0
Flush
2-wire,
N/O contact
contactless N/C contact
538288
SIED-M30B-ZS-K-L
538287
SIED-M30B-ZS-S-L
538290
SIED-M30B-ZO-K-L
538289
SIED-M30B-ZO-S-L
2-wire,
N/O contact
contactless N/C contact
538284
538286
SIED-M30NB-ZS-K-L
SIED-M30NB-ZO-K-L
538283
538285
SIED-M30NB-ZS-S-L
SIED-M30NB-ZO-S-L
M18
M30
15.0
1)
22
Non-flush
Sn Rated operating distance [mm]
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIED-…-PA, inductive
Technical data – Standard switching distance, polyamide housing, for DC and AC voltage
Function1)
1)
Standard switching distance
Corrosion-resistant
Polyamide housing
For DC and AC voltage
Round design
e.g. N/O contact with cable
General technical data
Design
Conforms to
Certification
CE mark (see declaration of conformity)
Note on materials
1)
Round
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
To EU Low Voltage Directive
Free of copper and PTFE
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp è Certificates.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
Input signal/measuring element
Ambient temperature
[°C]
Output, general
Mounting type
Size
–25 … +70
Flush
M12
M18
M30
Non-flush
M12
M18
M30
0.04
0.1
0.2
0.08
0.16
0.3
Switching output
Mounting type
Size
Flush
M12
M18
M30
Non-flush
M12
M18
M30
Switching output
Switching element function
Rated operating distance
Assured switching distance
Contactless, 2-wire
N/O contact
2
5
1.62
4.05
10
8.1
Contactless, 2-wire
N/O contact
4
8
3.24
6.48
Repetition accuracy
[mm]
[mm]
[mm]
Reduction factors
Aluminium
Stainless steel St 18/8
Copper
Brass
Steel St 37
Hysteresis
Max. switching frequency AC
Max. switching frequency DC
Max. output current
Minimum load current
Voltage drop
0.35 … 0.5
0.06 … 0.1
0.25 … 0.45
0.35 … 0.5
1.0
[mm]
[Hz]
[Hz]
[mA]
[mA]
[V]
0.06 … 0.3
20
60
100
3
6
15
12.15
0.35 … 0.5
0.06 … 0.1
0.25 … 0.45
0.35 … 0.5
1.0
0.15 … 0.75
0.3 … 1.5
300
300
0.12 … 0.6
20
60
100
3
6
0.24 … 1.2
0.45 … 2.25
300
300
Output, additional data
Protection against short circuit
2017/05 – Subject to change
No
è Internet: www.festo.com/catalogue/...
23
Proximity sensors SIED-…-PA, inductive
Technical data – Standard switching distance, polyamide housing, for DC and AC voltage
Electronic components
Operating voltage range AC
Operating voltage range DC
Idle current
Reverse polarity protection
[V AC]
[V DC]
[mA]
20 … 250
10 … 300
 1.5
For all electrical connections
Electromechanical components
Electrical connection
Cable length
Cable sheath material
Insulating sheath material
Cable, 2-wire
2.5
PVC
PVC
[m]
Mechanical components
Size
M12
Attachment type
Mounting type
Tightening torque
Product weight
Housing material
Via lock nut
Flush
1
109
PA-reinforced
[Nm]
[g]
M18
M30
2
123
5
175
Display/operation
Switching status display
Yellow LED
Immissions/emissions
Ambient temperature with flexible
cable installation
Protection class
Corrosion resistance class CRC1)
1)
[°C]
0 … +70
IP65, IP67
4
Corrosion resistance class CRC 4 to Festo standard FN 940070
Particularly high corrosion stress. Outdoor exposure under extreme corrosive conditions. Parts exposed to aggressive media, for instance in the chemical or food industries. These applications may need to be suppor­
ted by special tests (è also FN 940082) using appropriate media.
Download CAD data è www.festo.com
Dimensions
M12
1 2-core cable, 2.5 m
2 Active surface
M18
3 1 switching status display,
yellow
1 2-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
Type
B1
D1
D2

L1
L2
L10
ß1
SIED-M12-…-B-ZS-…-K-L-PA
SIED-M18-…-B-ZS-…-K-L-PA
8
8.2
M12x1
M18x1
5
5.2
60
60
40
50
4
4
17
24
24
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIED-…-PA, inductive
Technical data – Standard switching distance, polyamide housing, for DC and AC voltage
Download CAD data è www.festo.com
Dimensions
M30
1 2-core cable, 2.5 m
2 Active surface
3 1 switching status display, yellow
Type
B1
D1
D2

L1
L2
L10
ß1
SIED-M30-…-B-ZS-…-K-L-PA
10
M30x1.5
5
60
50
4
36
Fitting instructions
Flush fitting
Non-flush fitting
2 Active surface
5 Metal-free zone
2 Active surface
5 Metal-free zone
Size
B1
B2
H
Size
B1
B2
H1
H2
M12
M18
M30
18
27
45
24
36
60
6
15
30
M12
M18
M30
18
27
45
36
54
90
8
16
30
12
24
45
Ordering data
Size
Sn1)
Mounting type
Switching output
Switching element
function
Electrical connection
Cable
Part No.
Type
2.0
4.0
Flush
Non-flush
Contactless, 2-wire
N/O contact
538336
538335
SIED-M12B-ZS-K-L-PA
SIED-M12NB-ZS-K-L-PA
5.0
8.0
Flush
Non-flush
Contactless, 2-wire
N/O contact
538338
538337
SIED-M18B-ZS-K-L-PA
SIED-M18NB-ZS-K-L-PA
10.0
15.0
Flush
Non-flush
Contactless, 2-wire
N/O contact
538340
538339
SIED-M30B-ZS-K-L-PA
SIED-M30NB-ZS-K-L-PA
[mm]
M12
M18
M30
1)
Sn Rated operating distance [mm]
2017/05 – Subject to change
è Internet: www.festo.com/catalogue/...
25
Proximity sensors SIES, inductive
Technical data – Standard switching distance, special design
Standard switching distance
For DC voltage
Block-shaped design
Function1)
1)
e.g. antivalent with PNP output and terminals
General technical data
Conforms to
Certification
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
Free of copper and PTFE, RoHS-compliant
CE mark (see declaration of conformity)
Note on materials
1)
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp è Certificates.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
Input signal/measuring element
Type
Size
[mm]
SIES-Q5
5x5x25
Ambient temperature
[°C]
–25 … +70
Output, general
Type
Size
[mm]
SIES-Q5
5x5x25
SIES-Q8
8x8x40
Repetition accuracy
[mm]
0.04
Switching output
Type
Size
[mm]
SIES-Q5
5x5x25
[mm]
[mm]
PNP
NPN
N/O contact
N/C contact
0.8
0.64
Switching output
Switching element function
Rated operating distance
Assured switching distance
Reduction factors
Aluminium
Stainless steel St 18/8
Copper
Brass
Steel St 37
Max. switching frequency DC
Max. output current
Max. output current at  50 °C
Max. output current at  85 °C
Voltage drop
26
[Hz]
[mA]
[mA]
[mA]
[V]
SIES-Q8
8x8x40
SIES-V3
15x20x30
SIES-QB
12x26x40
SIES-Q40
40x40x120
SIES-V3
15x20x30
SIES-QB
12x26x40
SIES-Q40
40x40x120
0.07
0.1
0.1
0.75
SIES-Q8
8x8x40
SIES-V3
15x20x30
SIES-QB
12x26x40
SIES-Q40
40x40x120
–
PNP
–
Antivalent
1.5
1.2
PNP
NPN
N/O contact
–
2
1.6
–25 … +85
0.4
0.7
0.3
0.4
1.0
0.45
0.8
0.4
0.55
0.45
0.7
0.3
0.5
1.0
3000
200
–
–
2
3500
1200
–
200
150
 3.2
è Internet: www.festo.com/catalogue/...
N/C contact
15
12
0.8
0.35
0.3
0.7
0.25
0.3
1.0
100
–
200
150
 3.5
Subject to change – 2017/05
Proximity sensors SIES, inductive
Technical data – Standard switching distance, special design
Output, additional data
Protection against short circuit
Electronic components
Type
Size
Operating voltage range
Residual ripple
Idle current
Reverse polarity protection
Electromechanical components
Electrical connection
Type
Size
Electrical connection
Cable length
Cable sheath material
Mechanical components
Type
Size
Attachment type
Mounting type
Product weight
Housing material
Display/operation
Type
Size
Pulsed
[mm]
[V DC]
[%]
[mA]
[mm]
[m]
[mm]
[g]
[mm]
Ready status display
Switching status display
Immissions/emissions
Type
Size
Protection class
SIES-Q5
5x5x25
SIES-Q8
8x8x40
SIES-V3
15x20x30
10 … 30
10
 10
For all electrical connections
Cable
SIES-Q5
5x5x25
 30
SIES-QB
12x26x40
Cable, 3-wire
2.5
TPE-U (PUR)
SIES-Q5
5x5x25
 40
Plug
SIES-Q8
8x8x40
SIES-V3
15x20x30
Plug, M8x1, 3-pin
–
–
SIES-Q8
8x8x40
Via female thread
Flush
22
Nickel-plated brass
15
Chrome plated
die-cast zinc
SIES-Q8
8x8x40
SIES-Q40
40x40x120
Screw terminal
–
–
SIES-V3
15x20x30
SIES-QB
12x26x40
SIES-Q40
40x40x120
Via through-hole
Flush
120
Die-cast zinc
170
PBT-reinforced
230
PBT, PA
SIES-V3
15x20x30
SIES-QB
12x26x40
SIES-Q40
40x40x120
–
Yellow LED
[mm]
SIES-Q40
40x40x120
10 … 34
SIES-Q8
8x8x40
SIES-Q5
5x5x25
SIES-QB
12x26x40
Green LED
Yellow LED
SIES-Q5
5x5x25
SIES-Q8
8x8x40
SIES-V3
15x20x30
SIES-QB
12x26x40
IP67
SIES-Q40
40x40x120
IP65
Pin allocation to EN 60947-5-2
M8x1, 3-pin
N/O contact and N/C contact
2017/05 – Subject to change
Pin
Wire colour
Allocation
1
3
4
Brown
Blue
Black
+
–
Output
è Internet: www.festo.com/catalogue/...
27
Proximity sensors SIES, inductive
Technical data – Standard switching distance, special design
Download CAD data è www.festo.com
Dimensions
SIES-Q5B
Cable
SIES-Q8B
Cable
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display, yellow
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display, yellow
Plug
2 Active surface
4 4 switching status displays, yellow
Type
B1
D2

D2
D4
H1
L1
L2
L3
L4
L5
SIES-Q5B-…-K-L
SIES-Q8B-…-K-L
SIES-Q8B-…-S-L
5
8
8
2.5
3.5
–
–
–
M8x1
M1.6
M3
M3
1.5
3
3
25
40
59
16
37
50
14
20
20
5.5
10
10
3
5
5
Download CAD data è www.festo.com
Dimensions
SIES-V3B
Plug
SIES-QB
Cable
2 Active surface
3 4 switching status display, yellow
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display, yellow
4 Sensor centre
Type
B1
D1

D1
D2

D3

H1
H2
H3
H4
L1
L2
L3
L4
L5
SIES-V3B-…-S-S-L
SIES-QB-P-…-K-L
15
12
–
4.5
M8x1
–
10
–
4.5
3.2
42
26
30
17
5.5
4
13
–
20
40
12
32
–
6.5
–
4
–
6
28
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIES, inductive
Technical data – Standard switching distance, special design
Download CAD data è www.festo.com
Dimensions
SIES-Q40B
Plug
1 Green operational status indicator
2 Supplied with active surface facing forward:
sensor head can be adjusted to any one of 5
response directions
3 Switching status display LED (yellow)
5 M20x1.5, suitable for cable diameter
7.5 mm to 12.5 mm
Type
B1
B2
B3
D1

D2

H1
H2
L1
L2
L3
L4
L5
L6
SIE-Q40B-PA-X-2L
40
30
7
5.3
5.3
40
16
120
60
45
40
20
7.3
Fitting instructions
Flush fitting
2 Active surface
5 Metal-free zone
2017/05 – Subject to change
Size
B1
B2
H
5x5x25
8x8x40
15x20x30
12x26x40
40x40x120
2.5
4
6
6
25
5
12
12
12
75
2
3
5
5
30
è Internet: www.festo.com/catalogue/...
29
Proximity sensors SIES, inductive
Technical data – Standard switching distance, special design
Ordering data
Size
Sn1)
[mm]
[mm]
Mounting
type
Switching
output
Switching
Electrical connection
element function Cable
Part No.
Type
Plug
Part No.
Type
5x5x25
0.8
Flush
PNP
NPN
N/O contact
N/C contact
N/O contact
N/C contact
178291
174549
178290
174548
SIES-Q5B-PS-K-L
SIES-Q5B-PO-K-L
SIES-Q5B-NS-K-L
SIES-Q5B-NO-K-L
–
N/O contact
N/C contact
N/O contact
N/C contact
178294
174552
178292
174550
SIES-Q8B-PS-K-L
SIES-Q8B-PO-K-L
SIES-Q8B-NS-K-L
SIES-Q8B-NO-K-L
178295
174553
178293
174551
SIES-Q8B-PS-S-L
SIES-Q8B-PO-S-L
SIES-Q8B-NS-S-L
SIES-Q8B-NO-S-L
150491
150490
SIES-V3B-PS-S-L
SIES-V3B-NS-S-L
8x8x40
1.5
Flush
PNP
NPN
15x20x30
2.0
Flush
PNP
NPN
N/O contact
–
2.0
Flush
PNP
N/O contact
N/C contact
150488
150489
15.0
Flush
PNP
Antivalent
–
12x26x40
SIES-QB-PS-K-L
SIES-QB-PO-K-L
–
40x40x120
1)
2)
30
150492
SIES-Q40B-PA-X-2L2)
Sn Rated operating distance [mm]
Electrical connection via screw terminals
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEH, inductive
Technical data – Increased switching distance
Increased switching distance
For DC voltage
Round design
Function
General technical data
Size
Design
Conforms to
Certification
CE mark (see declaration of conformity)
Note on materials
1)
3 mm
M12
M18
Round
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
Free of copper and PTFE
–
–
EN 60947-5-2
cULus listed (OL)
C-Tick
To EU EMC Directive1)
Free of copper and PTFE
–
–
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
Free of copper and PTFE
RoHS-compliant
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp è Certificates.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
Input signal/measuring element
Size
Ambient temperature
3 mm
[°C]
Output, general
Size
Repetition accuracy
Repetition accuracy under constant
conditions
[mm]
[mm]
Switching output
Size
Switching output
Switching element function
Rated operating distance
Assured switching distance
[mm]
[mm]
Reduction factors
Aluminium
Stainless steel St 18/8
Copper
Brass
Steel St 37
Hysteresis
Switch-on time
Max. switching frequency
Max. output current
Voltage drop
2017/05 – Subject to change
[mm]
[ms]
[Hz]
[mA]
[V]
M12
M18
3 mm
M12
M18
0.02
–
–
0.2
0.4
–
3 mm
M12
M18
PNP
NPN
N/O contact
–
1
0.81
PNP
NPN
N/C contact
N/C contact
4
3.24
PNP
NPN
N/O contact
N/C contact
8
6.48
0.5
0.8
0.45
0.6
1.0
0.4
0.8
0.4
0.5
1.0
0.35
0.7
0.3
0.4
1.0
 0.12
0.02
3,000
100
0…2
 0.36
–
2,500
200
 0.88
–25 … +70
è Internet: www.festo.com/catalogue/...
1,500
200
31
Proximity sensors SIEH, inductive
Technical data – Increased switching distance
Output, additional data
Size
Protection against short circuit
Inductive protective circuit
Electronic components
Size
Operating voltage range
Residual ripple
Idle current
Reverse polarity protection
[V DC]
[%]
[mA]
3 mm
M12
M18
Pulsed
Integrated
Output current  100 mA
and switching frequency  10 Hz
Pulsed
Integrated
Pulsed
–
3 mm
M12
M18
±10
±20
10 … 30
20
0 … 10
For all electrical connections
Electromechanical components
Electrical connection
Size
Cable
3 mm
Electrical connection
Cable, 3-wire
Cable with plug,
M8x1, 3-pin
2.5
TPE-U (PUR)
PVC
–
–
0.15
TPE-U (PUR)
PVC
Cable
3 mm
M12
M18
Plug
3 mm
Cable length
Cable sheath material
Insulating sheath material
[m]
Mechanical components
Electrical connection
Size
Attachment type
Mounting type
Tightening torque
Product weight
Housing material
[Nm]
[g]
Clamped
Flush
–
18
High-alloy
stainless steel
M12
M18
Via lock nut
–
20
110
108
Nickel-plated brass
PBTP
–
Plug
3 mm
Clamped
Flush
–
4
High-alloy
stainless steel
M12
M18
Plug,
M12x1,
3-pin
–
M12
M18
Via lock nut
–
20
30
43
Nickel-plated brass
PBTP
PA
Display/operation
Switching status display
Yellow LED
Immissions/emissions
Electrical connection
Size
Cable
3 mm
Ambient temperature with flexible
cable installation
Protection class
[°C]
–5 … +70
Surge strength
Corrosion resistance class CRC1)
Degree of contamination
[kV]
–
IP67
–
4
–
1)
32
M12
M18
Plug
3 mm
M12
M18
IP65
–
–
2
–
0.8
–
3
–5 … +70
IP65
–
–
2
–
0.8
–
3
–
IP67
–
1
–
Corrosion resistance class CRC 1 to Festo standard FN 940070
Low corrosion stress. For dry indoor applications or transport and storage protection. Also applies to parts behind covers, in the non-visible interior area, and parts which are covered in the application (e.g. drive
trunnions).
Corrosion resistance class CRC 2 to Festo standard FN 940070
Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­
sphere typical for industrial applications.
Corrosion resistance class CRC 4 to Festo standard FN 940070
Particularly high corrosion stress. Outdoor exposure under extreme corrosive conditions. Parts exposed to aggressive media, for instance in the chemical or food industries. These applications may need to be suppor­
ted by special tests (è also FN 940082) using appropriate media.
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEH, inductive
Technical data – Increased switching distance
Pin allocation to EN 60947-5-2
M8x1, 3-pin
N/O contact
Pin
Wire colour Allocation
1
3
4
Brown
Blue
Black
M12x1, 3-pin
N/O contact
Pin
+
–
Output
1
3
4
N/C contact
Wire colour Allocation
Pin
Wire colour Allocation
Brown
Blue
Black
1
3
2
Brown
Blue
White
+
–
Output
+
–
Output
Download CAD data è www.festo.com
Dimensions – 3 mm
Cable
Plug
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display, yellow
Type
D1

D2

D3
L1
L2
L3
SIEH-3B-…-S-K-L
SIEH-3B-…-S-S-L
3
3
2.6
2.6
–
M8x1
22
22
–
150
16
16
Download CAD data è www.festo.com
Dimensions – M12
Cable
Plug
1
2
3
4
3-core cable, 2.5 m
Active surface
1 switching status display, yellow
4 switching status display, yellow
Type
B1
D1
D2

D2
D3

L1
L5
L6
L7
ß1
SIEH-M12B-…-K-L
SIEH-M12B-…-S-L
4
4
M12x1
M12x1
5
–
–
M12x1
–
10.5
35
45
–
11
–
5
–
3.3
17
17
2017/05 – Subject to change
è Internet: www.festo.com/catalogue/...
33
Proximity sensors SIEH, inductive
Technical data – Increased switching distance
Download CAD data è www.festo.com
Dimensions – M18
Cable
Plug
1
2
3
4
3-core cable, 2.5 m
Active surface
1 switching status display, yellow
4 switching status display, yellow
Type
B1
D1
D2

D2
D3

L1
L4
L5
L6
L7
ß1
SIEH-M18B-…-K-L
SIEH-M18B-…-S-L
4
4
M18x1
M18x1
5
–
–
M12x1
–
16.4
35
48.5
–
13.5
–
11
–
8
–
3
24
24
Fitting instructions
Flush fitting
Size
B1
B2
H
3 mm
M12
M18
2.5
10
18
5
24
40
3
12
24
2 Active surface
5 Metal-free zone
Ordering data
Size
Sn1)
Mounting
type
Switching
output
[mm]
Switching
Electrical connection
element function Cable
Part No.
Type
Plug
Part No.
Type
3 mm
1.0
Flush
PNP
NPN
N/O contact
N/O contact
538264
538266
SIEH-3B-PS-K-L
SIEH-3B-NS-K-L
538263
538265
SIEH-3B-PS-S-L
SIEH-3B-NS-S-L
4.0
Flush
PNP
N/O contact
N/C contact
N/O contact
N/C contact
150450
150454
150448
150452
SIEH-M12B-PS-K-L
SIEH-M12B-PO-K-L
SIEH-M12B-NS-K-L
SIEH-M12B-NO-K-L
150451
150455
150449
150453
SIEH-M12B-PS-S-L
SIEH-M12B-PO-S-L
SIEH-M12B-NS-S-L
SIEH-M12B-NO-S-L
N/O contact
N/C contact
N/O contact
N/C contact
150458
150462
150456
150460
SIEH-M18B-PS-K-L
SIEH-M18B-PO-K-L
SIEH-M18B-NS-K-L
SIEH-M18B-NO-K-L
150459
150463
150457
150461
SIEH-M18B-PS-S-L
SIEH-M18B-PO-S-L
SIEH-M18B-NS-S-L
SIEH-M18B-NO-S-L
M12
NPN
M18
7.0
Flush
PNP
NPN
1)
34
Sn Rated operating distance [mm]
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEH-…-CR, inductive
Technical data – Increased switching distance
Function1)
1)
e.g. N/O contact with PNP output and cable
General technical data
Size
Switching output
M12
PNP
Conforms to
Certification
CE mark (see declaration of conformity)
Note on materials
1)
Increased switching distance
For DC voltage
Round design
Resistant to chemicals
and mechanical stress
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
Free of copper and PTFE
NPN
–
M18
PNP
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
Free of copper and PTFE
NPN
–
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp è Certificates.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
Input signal/measuring element
Ambient temperature
[°C]
Output, general
Size
Reproducibility, switching value FS
[mm]
Switching output
Size
Switching output
[mm]
[mm]
Reduction factors
Aluminium
Stainless steel, 1 mm thick
Stainless steel, 2 mm thick
Copper
Brass
Steel St 37
Hysteresis
Max. switching frequency
Max. output current
Voltage drop
2017/05 – Subject to change
M12
M18
0.3
0.5
M12
PNP
Switching output
Switching element function
Rated operating distance
Assured switching distance
–25 … +70
[mm]
[Hz]
[mA]
[V]
NPN
M18
PNP
PNP
NPN
N/O contact
6
4.86
PNP
NPN
N/O contact
10
8.1
1.0
0.45
0.9
0.85
1.3
1.0
1.0
0.4
0.8
0.8
1.3
1.0
 0.73
600
200
2
 1.22
200
200
2
2
è Internet: www.festo.com/catalogue/...
NPN
0.85
2
35
Proximity sensors SIEH-…-CR, inductive
Technical data – Increased switching distance
Output, additional data
Protection against short circuit
Inductive protective circuit
Pulsed
Integrated
Output current  100 mA
and switching frequency  10 Hz
Electronic components
Switching output
PNP
NPN
10 … 30
20
 12
For all electrical connections
10 … 30
20
 17
For all electrical connections
Electromechanical components
Electrical connection
Cable
Plug
Electrical connection
Cable sheath material
Cable, 3-wire
TPE-U (PUR)
Plug, M12x1, 3-pin
–
Mechanical components
Size
Electrical connection
M12
Cable
Size
Attachment type
Mounting type
Product weight
Housing material
M12
Via lock nut
Flush
90
High-alloy steel
Operating voltage range
Residual ripple
Idle current
Reverse polarity protection
[V DC]
[%]
[mA]
[g]
M18
Cable
Plug
Plug
M18
Via lock nut
Flush
115
High-alloy steel
28
53
Display/operation
Switching status display
Yellow LED
Immissions/emissions
Size
Switching output
M12
PNP
Ambient temperature with flexible
cable installation
Protection class
[°C]
Corrosion resistance class CRC1)
Resistance to sensor fitting pressure [bar]
1)
NPN
–5 … +70
–5 … +70
IP67
IP69K
2
80
IP67
IP69K
2
60
Corrosion resistance class CRC 2 to Festo standard FN 940070
Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­
sphere typical for industrial applications.
Pin allocation to EN 60947-5-2
M8x1, 3-pin
N/O contact
Pin
Wire colour Allocation
1
3
4
36
M18
PNP
NPN
Brown
Blue
Black
+
–
Output
M12x1, 3-pin
N/O contact
Pin
1
3
4
è Internet: www.festo.com/catalogue/...
N/C contact
Wire colour Allocation
Pin
Wire colour Allocation
Brown
Blue
Black
1
3
2
Brown
Blue
White
+
–
Output
+
–
Output
Subject to change – 2017/05
Proximity sensors SIEH-…-CR, inductive
Technical data – Increased switching distance
Download CAD data è www.festo.com
Dimensions – M12
Cable
Plug
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status display,
yellow
Type
B1
D1
D2

D2
D3

L1
L4
L5
L6
ß1
SIEH-M12B-…-S-K-L-CR
SIEH-M12B-…-S-S-L-CR
4
4
M12x1
M12x1
5
–
–
M12x1
–
10.5
50
60
–
19
–
11
–
8
17
17
Download CAD data è www.festo.com
Dimensions – M18
Cable
Plug
1 3-core cable, 2.5 m
2 Active surface
3 1 switching status display,
yellow
4 4 switching status display,
yellow
Type
B1
D1
D2

D2
D3

L1
L4
L5
L6
L7
ß1
SIEH-M18B-…-S-K-L-CR
SIEH-M18B-…-S-S-L-CR
4
4
M18x1
M18x1
5
–
–
M12x1
–
16
50
63.5
–
13
–
11
–
8
–
8
24
24
2017/05 – Subject to change
è Internet: www.festo.com/catalogue/...
37
Proximity sensors SIEH-…-CR, inductive
Technical data – Increased switching distance
Fitting instructions
Flush fitting
Size
B1
B2
H
M12
M18
12
25
40
60
18
30
2 Active surface
5 Metal-free zone
Ordering data
Size
Sn1)
Mounting
type
Switching
output
[mm]
Switching
Electrical connection
element function Cable
Part No.
Type
Plug
Part No.
Type
M12
6.0
Flush
PNP
NPN
N/O contact
N/O contact
538252
538254
SIEH-M12B-PS-K-L-CR
SIEH-M12B-NS-K-L-CR
538251
538253
SIEH-M12B-PS-S-L-CR
SIEH-M12B-NS-S-L-CR
10.0
Flush
PNP
NPN
N/O contact
N/O contact
538256
538258
SIEH-M18B-PS-K-L-CR
SIEH-M18B-NS-K-L-CR
538255
538257
SIEH-M18B-PS-S-L-CR
SIEH-M18B-NS-S-L-CR
M18
1)
38
Sn Rated operating distance [mm]
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEA, inductive
Technical data – Analogue output
Analogue output
For DC voltage
Round design
Function1)
1)
e.g. with analogue output for current and
voltage
General technical data
Design
Certification
CE mark (see declaration of conformity)
Note on materials
1)
Round
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
Free of copper and PTFE
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp è Certificates.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
Input signal/measuring element
Size
Ambient temperature
Position measuring range
Distance resolution
Temperature drift of real switching
distance
M8
[°C]
[mm]
[mm]
[%]
[%]
Output, general
Size
Repetition accuracy
Repetition accuracy under constant
conditions
M8
[mm]
[mm]
Switching output
Size
Analogue output
Output voltage at 23 °C
Output current at 23 °C
Reduction factors
Aluminium
Stainless steel St 18/8
Copper
Brass
Steel St 37
2017/05 – Subject to change
–25 … +70
0…4
0.001
 ±10 (–25 … 0 °C)
 ±5 (0 … 70 °C)
[V]
[mA]
[V]
[V]
[V]
[mA]
[mA]
M12
0…6
M12
0.3
±0.01
M18
M30
–25 … +70
0 … 10
0.002
 ±10
0 … 20
0.005
M18
M30
0.3
±0.02
±0.05
M8
M12
M18
M30
0 … 10
–
+10/±0.4 (s = 4 mm)
+5.2/±0.4 (s = 2 mm)
0/–0 +0.4 (s = 0 mm)
–
0 … 10
4 … 20
+10/±0.4 (s = 6 mm)
+5.2/±0.4 (s = 3 mm)
0/–0 +0.4 (s = 0 mm)
20/±0.8 (s = 6 mm)
4/±0.8 (s = 0 mm)
0 … 10
4 … 20
+10/±0.4 (s = 10 mm)
+5.2/±0.4 (s = 5 mm)
0/–0 +0.4 (s = 0 mm)
20/±0.8 (s = 10 mm)
4/±0.8 (s = 0 mm)
0 … 10
4 … 20
+10/±0.4 (s = 20 mm)
+5.2/±0.4 (s = 10 mm)
0/–0 +0.4 (s = 0 mm)
20/±0.8 (s = 20 mm)
4/±0.8 (s = 0 mm)
0.28
0.68
0.25
0.4
1.0
0.28
0.47
0.2
0.35
1.0
0.18
0.6
0.15
0.28
1.0
0.2
0.65
0.17
0.3
1.0
è Internet: www.festo.com/catalogue/...
39
Proximity sensors SIEA, inductive
Technical data – Analogue output
Switching output
Size
M8
M12
M18
M30
[Ω]
1,600
1,600
(–3 dB at s = 2 mm)
–
1,000
1,000
(–3 dB at s = 3 mm)
500
500
500
(–3 dB at s = 5 mm)
500
200
200
(–3 dB at s = 10 mm)
500
[mA]
10
10
10
10
[%]
120
120
120
120
M18
M30
Max. switching frequency DC
Bandwidth
[Hz]
[Hz]
Max. load at analogue current
output
Max. load current at analogue
voltage output
Max. current/voltage output value
without object
Output, additional data
Protection against short circuit
Protection against overloading
Pulsed
Yes
Electronic components
Operating voltage range
Residual ripple
Idle current
Reverse polarity protection
[V DC]
[%]
[mA]
15 … 30
20
 10
For operating voltage
Electromechanical components
Size
M8
M12
Electrical connection
Plug, M8x1, 3-pin
Plug, M12x1, 4-pin
Mechanical components
Size
M8
M12
M18
M30
Attachment type
Mounting type
Tightening torque
Product weight
Housing material
Via lock nut
Flush
4
25
Chrome-plated brass
10
33
25
55
70
155
[Nm]
[g]
Immissions/emissions
Protection class
Corrosion resistance class CRC1)
1)
IP67
2
Corrosion resistance class CRC 2 to Festo standard FN 940070
Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­
sphere typical for industrial applications.
Pin allocation
M8x1, 3-pin
40
M12x1, 4-pin
Pin
Wire colour
Allocation
Pin
Wire colour
Allocation
1
3
4
Brown
Blue
Black
+
–
Voltage
1
2
3
4
Brown
White
Blue
Black
+
Current
–
Voltage
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEA, inductive
Technical data – Analogue output
Download CAD data è www.festo.com
Dimensions
M8
M12
2 Active surface
Type
B1
D1
D2

D2
D3

L1
L4
L6
L7
ß1
SIEA-M8B-PU-S
SIEA-M12B-UI-S
4
4
M8x1
M12x1
–
–
M8x1
M12x1
6.5
10.5
60
60
–
16
6
8
8.5
–
13
17
M18
M30
2 Active surface
Type
B1
D1
D2
D3

L1
L4
L6
L7
ß1
SIEA-M18B-UI-S
SIEA-M30B-UI-S
4
5
M18x1
M30x1.5
M12x1
M12x1
16
27.5
63.5
73.5
12.5
12.5
8
8
9
9
24
36
2017/05 – Subject to change
è Internet: www.festo.com/catalogue/...
41
Proximity sensors SIEA, inductive
Technical data – Analogue output
Fitting instructions
Flush fitting
Size
B1
B2
H1
H2
M8
M12
M18
M30
8
12
19
35
20
30
44
80
1
2
4
6
12
18
30
60
2 Active surface
5 Metal-free zone
Ordering data
Size
S1)
Mounting type
Analogue output
Electrical connection
Plug
Part No.
Type
0…4
Flush
0 … 10 V
–
538291
SIEA-M8B-PU-S
0…6
Flush
0 … 10 V
4 … 20 mA
538292
SIEA-M12B-UI-S
0 … 10
Flush
0 … 10 V
4 … 20 mA
538293
SIEA-M18B-UI-S
0 … 20
Flush
0 … 10 V
4 … 20 mA
538294
SIEA-M30B-UI-S
[mm]
M8
M12
M18
M30
1)
42
S
Position measuring range [mm]
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEF, inductive
Technical data – Increased switching distance, reduction factor 1, welding field immune
Function1)
1)
Standard switching distance
Reduction factor 1 for all metals
For DC voltage
Round design
e.g. N/O contact with PNP output and cable
General technical data
Mounting type
Size
Flush
M8
Design
Round
Round
Conforms to
Certification
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
Free of copper and PTFE
RoHS-compliant
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
Free of copper and PTFE
–
CE mark (see declaration of conformity)
Note on materials
1)
M12
M18
M30
Partially flush
M8
M12
M18
M30
Q40
Blockshaped
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp è Certificates.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
Input signal/measuring element
Mounting type
Electrical connection
Ambient temperature
[°C]
Output, general
Mounting type
Size
Repetition accuracy
[mm]
Switching output
Mounting type
Size
Switching output
Switching element function
Rated operating distance
Assured switching distance
[mm]
[mm]
Reduction factors
Aluminium
Stainless steel St 18/8
Copper
Brass
Steel St 37
Hysteresis
Max. switching frequency DC
Max. output current
Voltage drop
2017/05 – Subject to change
Flush
Cable
Plug
Partially flush
Cable
–30 … +70
–30 … +85
–30 … +85
Flush
M8
M12
M18
M30
Partially flush
M8
M12
M18
M30
Q40
0.08
0.16
0.28
0.55
0.08
0.16
0.24
0.4
0.7
Flush
M8
M12
M18
M30
Partially flush
M8
M12
M18
M30
Q40
10
–
PNP
NPN
N/O contact
4
8
3.24
6.48
12
9.72
20
16.2
Antivalent
35
28.35
0.36…1.8
2,000
0.36…1.8
1,500
1.05…5.25
250
PNP
NPN
N/O contact
1.5
3
–
–
5
–
–
[mm]
[Hz]
[mA]
[V]
Plug
–
2,000
150
–
1.0
1.0
1.0
1.0
1.0
3,000
200
2,500
2,000
0.12…0.6
2,000
150
 1.8
0.24…1.2
2,000
200
è Internet: www.festo.com/catalogue/...
43
Proximity sensors SIEF, inductive
Technical data – Increased switching distance, reduction factor 1, welding field immune
Output, additional data
Protection against short circuit
Pulsed
Electronic components
Mounting type
Size
Flush
M8
Operating voltage range
Residual ripple
Idle current
Reverse polarity protection
[V DC]
[%]
[mA]
Electromechanical components
Mounting type
Size
Cable
Electrical connection
Cable length
Cable sheath material
Insulating sheath material
Plug
Electrical connection
M12
10 … 30
10
 15
For all electrical connections
M30
Partially flush
M8
M12
M18
Q40
10 … 65
10
 15
M30
Q40
Plug,
M8x1,
3-pin
Plug,
M12x1,
4-pin,
Fixcon
Plug,
M12x1,
3-pin
Plug
61.4
12
High-alloy stainless
steel
PA
PP
–
Mechanical components
Mounting type
Size
Electrical connection
Partially flush
M8
Cable
Plug
Attachment type
Via lock nut
44
M30
Plug,
M8x1,
3-pin
Flush
M8
Cable
[Nm]
[g]
M18
–
Mechanical components
Mounting type
Size
Electrical connection
Tightening torque
Product weight
Housing material
M18
Partially flush
M8
M12
Cable, 3-wire
2.5
TPE-U (PUR)
PVC
Chrome-plated brass
[g]
M30
Cable, 3-wire
2.5
TPE-U (PUR)
PVC
Plug housing material
Product weight
Housing material
M18
10 … 30
–
–
For all electrical connections
Flush
M8
[m]
M12
10
10
77
19
High-alloy stainless
steel
PA
Plug,
M12x1,
3-pin,
Fixcon
Chrome-plated brass
M12
Cable
Plug
M18
Cable
Plug
M30
Cable
Plug
Q40
Plug
105
24
Chrome-plated brass
124
41
Chrome-plated brass
191
100
Chrome-plated brass
LCP-reinforced
TPE-O
–
LCP-reinforced
TPE-O
–
LCP-reinforced
TPE-O
–
156
PBTreinforced
PA
–
M12
Cable
M18
Cable
M30
Cable
Q40
Plug
Plug
Plug
Plug
10
10
120
22
Chrome-plated brass
25
25
141
38
Chrome-plated brass
75
75
194
90
Chrome-plated brass
PBT
PBT
PBT
è Internet: www.festo.com/catalogue/...
Via
throughhole
–
156
PBTreinforced
PA
Subject to change – 2017/05
Proximity sensors SIEF, inductive
Technical data – Increased switching distance, reduction factor 1, welding field immune
Display/operation
Mounting type
Size
Flush
M8
Ready status display
Switching status display
–
Yellow LED
Immissions/emissions
Electrical connection
Size
Cable
M8
Flush
Ambient temperature with flexible
[°C]
cable installation
Protection class
Resistance to interference from magnetic
fields
Surge resistance
[kV]
Corrosion resistance class CRC1)
Degree of contamination
Partially flush
Ambient temperature with flexible
[°C]
cable installation
Protection class
Resistance to interference from magnetic
fields
Surge resistance
[kV]
Corrosion resistance class CRC1)
Degree of contamination
1)
M12
M18
M30
Partially flush
M8
M12
M18
M30
–
Yellow LED
M12
M18
M30
Plug
M8
Green LED
Yellow LED
M12
M18
–5 … +70
–
IP68
Magnetic direct and alternating field
IP68
Magnetic direct and alternating field
0.8
2
3
0.8
2
3
0 … 80
–
IP67
Magnetic direct and alternating field
IP67
Magnetic direct and alternating field
–
4
–
–
4
–
2
Q40S
M30
Q40
–
2
–
Corrosion resistance class CRC 2 to Festo standard FN 940070
Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo­
sphere typical for industrial applications.
Corrosion resistance class CRC 4 to Festo standard FN 940070
Particularly high corrosion stress. Outdoor exposure under extreme corrosive conditions. Parts exposed to aggressive media, for instance in the chemical or food industries. These applications may need to be suppor­
ted by special tests (è also FN 940082) using appropriate media.
Pin allocation to EN 60947-5-2
M8x1, 3-pin
N/O contact
Pin
M12x1, 3-pin
N/O contact
Wire colour
Allocation
Pin
Wire colour
Allocation
1
3
4
Brown
Blue
Black
+
–
Output
1
3
4
Brown
Blue
Black
+
–
Output
Pin
Wire colour
Allocation
Pin
Wire colour
Allocation
1
2
3
4
Brown
White
Blue
Black
+
N/O contact
–
N/C contact
1
2
3
4
Brown
White
Blue
Black
+
N/C contact
–
N/O contact
M12x1, 4-pin
NPN, antivalent
PNP, antivalent
2017/05 – Subject to change
è Internet: www.festo.com/catalogue/...
45
Proximity sensors SIEF, inductive
Technical data – Increased switching distance, reduction factor 1, welding field immune
Dimensions
M8 – Flush fitting
Cable
Download CAD data è www.festo.com
Plug
M8 – Partially flush fitting
Cable
Plug
M12 – Flush fitting
Cable
Plug
M12 – Partially flush fitting
Cable
Plug
M18 – Flush fitting
Cable
Plug
M18 – Partially flush fitting
Cable
Plug
Mounting type
M8
Flush
Partially flush
M12
Flush
Partially flush
M18
Flush
Partially flush
46
D1
D2
L1
ß
Cable
Plug
Cable
Plug
M8x1
4
M8x1
4
M8x1
41.6
49
41.6
52
13
Cable
Plug
Cable
Plug
M12x1
5.2
M12x1
5
M12x1
50
52
50
52
17
Cable
Plug
Cable
Plug
M18x1
5.2
M12x1
5.2
M12x1
50
52
50
52
24
Electrical
connection
M8x1
M12x1
M18x1
è Internet: www.festo.com/catalogue/...
1 Connecting cable
2 Active surface
3 LED
13
17
13
24
Subject to change – 2017/05
Proximity sensors SIEF, inductive
Technical data – Increased switching distance, reduction factor 1, welding field immune
Download CAD data è www.festo.com
Dimensions
M30 – Flush fitting
Cable
Mounting type
M30
Flush
Partially flush
M30 – Partially flush fitting
Cable
Plug
D1
D2
L1
ß
M30x1.5
5.2
M12x1
5.2
M12x1
60
62
60
62
36
Electrical
connection
Cable
Plug
Cable
Plug
Plug
M30x1.5
1 Connecting cable
2 Active surface
3 LED
36
Download CAD data è www.festo.com
Dimensions – 40x40x65 mm
Partially flush fitting
2 Active surface
3 LED
Mounting type
40x40x65 mm
Partially flush
Electrical
connection
B1
B2
B3
B4
D1
D2
H1
H2
L1
L2
L3
L4
Plug
40
30
20
5.3
M12x1
5.3
40
34
65
60
46
7.3
Fitting instructions
Flush fitting
Partially flush fitting
2 Active surface
5 Metal-free zone
2 Active surface
5 Metal-free zone
Size
B1
B2
H
M8
M12
M18
M30
12
18
27
45
16
24
36
60
4.5
12
15
30
2017/05 – Subject to change
Size
B1
B2
H1
H2
M8
M12
M18
M30
40x40x65 mm
12
18
27
45
60
32
48
54
90
120
8
16
24
30
30
12
24
36
60
105
è Internet: www.festo.com/catalogue/...
47
Proximity sensors SIEF, inductive
Technical data – Increased switching distance, reduction factor 1, welding field immune
Ordering data
Size
Sn1)
Mounting
type
[mm]
Switching
element
function
Switching
output
Electrical connection
Cable
Part No.
Type
Plug
Part No.
Type
N/O contact
PNP
NPN
PNP
NPN
553538
553540
538308
538310
SIEF-M8B-PS-K-L
SIEF-M8B-NS-K-L
SIEF-M8NB-PS-K-L
SIEF-M8NB-NS-K-L
553537
553539
538307
538309
SIEF-M8B-PS-S-L
SIEF-M8B-NS-S-L
SIEF-M8NB-PS-S-L
SIEF-M8NB-NS-S-L
N/O contact
PNP
NPN
PNP
NPN
553542
553544
538312
538314
SIEF-M12B-PS-K-L
SIEF-M12B-NS-K-L
SIEF-M12NB-PS-K-L
SIEF-M12NB-NS-K-L
553541
553543
538311
538313
SIEF-M12B-PS-S-L
SIEF-M12B-NS-S-L
SIEF-M12NB-PS-S-L
SIEF-M12NB-NS-S-L
N/O contact
PNP
NPN
PNP
NPN
553546
553548
538316
538318
SIEF-M18B-PS-K-L
SIEF-M18B-NS-K-L
SIEF-M18NB-PS-K-L
SIEF-M18NB-NS-K-L
553545
553547
538315
538317
SIEF-M18B-PS-S-L
SIEF-M18B-NS-S-L
SIEF-M18NB-PS-S-L
SIEF-M18NB-NS-S-L
N/O contact
PNP
NPN
PNP
NPN
553550
553552
538320
538322
SIEF-M30B-PS-K-L
SIEF-M30B-NS-K-L
SIEF-M30NB-PS-K-L
SIEF-M30NB-NS-K-L
553549
553551
538319
538321
SIEF-M30B-PS-S-L
SIEF-M30B-NS-S-L
SIEF-M30NB-PS-S-L
SIEF-M30NB-NS-S-L
PNP
NPN
–
538341
538342
SIEF-Q40S-PA-S-2L
SIEF-Q40S-NA-S-2L
M8
1.5
Flush
4.0
Partially
flush
3.0
Flush
8.0
Partially flush
5.0
Flush
12.0
Partially flush
10.0
Flush
20.0
Partially flush
35.0
Partially flush Antivalent
M12
M18
M30
40x40x65 mm
1)
48
Sn Rated operating distance [mm]
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEF-…-WA, inductive
Technical data – Increased switching distance, reduction factor 1, welding field immune
Function1)
1)
Standard switching distance
Reduction factor 1 for all metals
Welding field immune
For DC voltage
Round design
e.g. N/O contact with PNP output and cable
General technical data
Design
Conforms to
Certification
CE mark (see declaration of conformity)
1)
Round
EN 60947-5-2
cULus listed (OL)
RCM trademark
To EU EMC Directive1)
For information about the applicability of the component see the manufacturer’s EC declaration of conformity at: www.festo.com/sp è Certificates.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.
Input signal/measuring element
Ambient temperature
[°C]
Output, general
Mounting type
Size
Repetition accuracy
[mm]
Switching output
Mounting type
Size
Switching output
Switching element function
Rated operating distance
Assured switching distance
[mm]
[mm]
Reduction factors
Aluminium
Stainless steel St 18/8
Copper
Brass
Steel St 37
Hysteresis
Max. switching frequency DC
Max. output current
Voltage drop
–30 … +85
Flush
M12
M18
M30
Partially flush
M12
M18
M30
0.06
0.1
0.2
0.16
0.24
0.4
Flush
M12
M18
M30
Partially flush
M12
M18
M30
PNP
NPN
N/O contact
3
2.43
5
4.05
10
16.2
8
6.48
12
9.72
20
16.2
0.15 … 0.75
2,500
0.36 … 1.8
1,500
0.24 … 1.2
2,000
0.36 … 1.8
2,000
0.36 … 1.8
1,500
1.0
1.0
1.0
1.0
1.0
[mm]
[Hz]
[mA]
[V]
0.24 … 1.2
3,000
200
 1.8
Output, additional data
Protection against short circuit
2017/05 – Subject to change
Pulsed
è Internet: www.festo.com/catalogue/...
49
Proximity sensors SIEF-…-WA, inductive
Technical data – Increased switching distance, reduction factor 1, welding field immune
Electronic components
Operating voltage range
Residual ripple
Idle current
Reverse polarity protection
[V DC]
[%]
[mA]
10 … 30
10
 15
For all electrical connections
Electromechanical components
Electrical connection
Plug housing material
Plug, M12x1, 3-pin, Fixcon
PTFE-coated brass
Mechanical components
Size
Mounting type
M12
Flush
Switching output
PNP/NPN
Attachment type
Tightening torque
Product weight
Housing material
Via lock nut
7
26
PTFE-coated brass
PBT
[Nm]
[g]
Partially
flush
PNP/NPN
M18
Flush
PNP/NPN
15
48
Partially
flush
PNP/NPN
M30
Flush
Partially flush
PNP
NPN
PNP
NPN
75
373
75
464
919
1,010
Display/operation
Switching status display
Yellow LED
Immissions/emissions
Protection class
Resistance to interference from magnetic
fields
IP67
Magnetic direct and alternating field
Pin allocation to EN 60947-5-2
M12x1, 3-pin
N/O contact
50
Pin
Wire colour
Allocation
1
3
4
Brown
Blue
Black
+
–
Output
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIEF-…-WA, inductive
Technical data – Increased switching distance, reduction factor 1, welding field immune
Download CAD data è www.festo.com
Dimensions
M12
Flush fitting
Partially flush fitting
M30
Flush fitting
Partially flush fitting
Mounting type
Electrical
connection
M18
Flush fitting
Partially flush fitting
D1
D2
L1
ß
M12
Flush
Partially flush
Plug
M12x1
M12x1
52
17
13
M18
Flush
Partially flush
Plug
M18x1
M12x1
52
24
M30
Flush
Partially flush
Plug
M30x1.5
M12x1
62
36
Fitting instructions
Flush fitting
2 Active surface
3 LED
Partially flush fitting
2 Active surface
5 Metal-free zone
2 Active surface
5 Metal-free zone
Size
B1
B2
H
Size
B1
B2
H1
H2
M12
M18
M30
18
27
45
24
36
60
9
15
30
M12
M18
M30
18
27
45
48
54
90
16
24
40
24
36
60
2017/05 – Subject to change
è Internet: www.festo.com/catalogue/...
51
Proximity sensors SIEF-…-WA, inductive
Technical data – Increased switching distance, reduction factor 1, welding field immune
Ordering data
Size
Sn1)
Mounting type
Switching element
function
Switching output
Electrical connection
Plug
Part No.
Type
3.0
Flush
N/O contact
8.0
Partially flush
PNP
NPN
PNP
NPN
538297
538298
538295
538296
SIEF-M12B-PS-S-L-WA
SIEF-M12B-NS-S-L-WA
SIEF-M12NB-PS-S-L-WA
SIEF-M12NB-NS-S-L-WA
5.0
Flush
N/O contact
12.0
Partially flush
PNP
NPN
PNP
NPN
538301
538302
538299
538300
SIEF-M18B-PS-S-L-WA
SIEF-M18B-NS-S-L-WA
SIEF-M18NB-PS-S-L-WA
SIEF-M18NB-NS-S-L-WA
10.0
Flush
N/O contact
20.0
Partially flush
PNP
NPN
PNP
NPN
538305
538306
538303
538304
SIEF-M30B-PS-S-L-WA
SIEF-M30B-NS-S-L-WA
SIEF-M30NB-PS-S-L-WA
SIEF-M30NB-NS-S-L-WA
[mm]
M12
M18
M30
1)
52
Sn Rated operating distance [mm]
è Internet: www.festo.com/catalogue/...
Subject to change – 2017/05
Proximity sensors SIE…, inductive
Accessories
Ordering data – Connecting cables M8x1
Number Cable
of wires length [m]
Straight socket
3
2.5
5
Ordering data – Connecting cables M12x1
Technical data è Internet: nebu
Part No.
Type
q541333
q541334
NEBU-M8G3-K-2.5-LE3
NEBU-M8G3-K-5-LE3
Number Cable
of wires length [m]
Straight socket
3
4
Angled socket
3
2.5
5
Straight socket, straight plug
4
2.5
1)
q541338
q541341
554037
NEBU-M8W3-K-2.5-LE3
NEBU-M8W3-K-5-LE3
Angled socket
3
NEBU-M8G3-K-2.5-M8G41)
For connecting proximity sensor SIEA-M8B to signal converter SVE4-US.
4
Ordering data – Mounting attachments
For size
Part No.
Sensor bracket with stop for flush fitting
M8
538346
Technical data è Internet: nebu
Type
2.5
5
2.5
5
q541363
q541364
q550326
q541328
NEBU-M12G5-K-2.5-LE3
NEBU-M12G5-K-5-LE3
NEBU-M12G5-K-2.5-LE41)
NEBU-M12G5-K-5-LE41)
2.5
5
2.5
5
541367
541370
550325
541329
NEBU-M12W5-K-2.5-LE3
NEBU-M12W5-K-5-LE3
NEBU-M12W5-K-2.5-LE41)
NEBU-M12W5-K-5-LE41)
554036
NEBU-M12G5-K-2.5-M8G4 2)
Straight socket, straight plug
4
2.5
1)
2)
Part No.
For connecting proximity sensor SIE…-M12/M18/M30 in N/C contact version with plug.
For connecting proximity sensor SIEA-M…B to signal converter SVE4.
Type
Ordering data – Mounting attachments
For size
Part No.
Type
SIEZ-B-8
Foot mounting
M12
5123
HBN-8/10x1
M12
M18
M30
538348
538350
538352
SIEZ-B-12
SIEZ-B-18
SIEZ-B-30
Flange mounting
M30
195855
FBN-32
Sensor bracket without stop
4
6.5
M8
538343
538344
538345
SIEZ-NB-4
SIEZ-NB-6,5
SIEZ-NB-8
Mounting bracket
SIES-V3B
9634
HV-M5
M12
M18
M30
538347
538349
538351
SIEZ-NB-12
SIEZ-NB-18
SIEZ-NB-30
M12, M18
538354
SIEZ-UH
M8
11542
SDA-8x1-B
M12
11541
SDA-12x1-B
Stop
Festo core product range
2017/05 – Subject to change
qReady for dispatch from the Festo factory in 24 hours
wReady for dispatch in 5 days maximum from stock
è Internet: www.festo.com/catalogue/...
53