YOUR REF 來函檔號: BD/GR/1-50/76(III) OUR REF 本署檔號: FAX 圖文傳真: 2626 1762 2398 3107 TEL 電話: www.bd.gov.hk 26 August 2016 To All Authorized Persons Registered Structural Engineers Registered Geotechnical Engineers Registered Inspectors Registered General Building Contractors Registered Specialist Contractors Registered Minor Works Contractors Dear Sir/Madam, Code of Practice for Structural Use of Concrete 2013 Construction Standard CS2:2012 – Steel Reinforcing Bars for the Reinforcement of Concrete The Standing Committee on Concrete Technology (SCCT) has recently issued a Technical Note No. 3 on the captioned Construction Standard CS2:2012 with regard to the nitrogen contents and nitrogen binding elements in steel reinforcing bars. Note b of Table 4 of CS2:2012 permits a higher nitrogen content in chemical composition of steel reinforcing bars if it can be demonstrated that there are sufficient quantities of nitrogen binding elements to combine with the nitrogen. In this connection, SCCT Technical Note No. 3 provides guidance on the demonstration of the sufficiency of nitrogen binding elements in steel reinforcing bars. Details of the above are available in the website of the Civil Engineering and Development Department at http://www.cedd.gov.hk under the “Standing Committee on Concrete Technical (SCCT) Publications” page of “Publications” section. Yours faithfully, ( LEE Yun-choi ) Assistant Director / New Buildings 2 for Building Authority 12/F-18/F Pioneer Centre, 750 Nathan Road, Mongkok, Kowloon, Hong Kong. 香港九龍旺角彌敦道 750 號始創中心 12 樓至 18 樓