Ordering Information Disinfection Controllers WDIS400 Series WDIS410U voltage output sensor Webmaster ONE ® USB WebMasterONE is the most advanced online cooling tower and boiler controller in the water treatment industry. The flexible multi-I/O platform allows you to control multiple cooling towers, boilers, closed loops, and condensate lines with just one controller. An extensive assortment of integrated communications and data handling features are included that enable water treatment professional to provide more effective water management services to their customers. VOLTAGE 1=120 VAC, prewired w/ USA power cord & 6” pigtails 5=Hardwired, cable glands OUTPUT N=No data output 4=One (1) Isolated 4-20 mA output 2=Two (2) Isolated 4-20 mA outputs Metering Pumps The E-Class is the most innovative and comprehensive metering pump product line in the world. Over 50 years of pump experience and a commitment to superior mechanical design has led to development of many industry firsts, including 360 stroke-perminute technology, IP67 waterproof construction, and the world’s highest capacity solenoid metering pumps. SENSOR (consult factory for other sensor types & ranges) N= No sensor 1=Free chlorine/bromine sensor with flow cell & 20 ft. cable 2=Chlorine dioxide sensor with flow cell & 20 ft. cable 3=Ozone sensor with flow cell & 20 ft. cable 4=Peracetic acid sensor with flow cell & 20 ft. cable 5=Free chlorine/bromine sensor with flow manifold &5 ft. cable on panel 6=Chlorine dioxide sensor with flow manifold & 5 ft. cable on panel 7=Ozone sensor with flow manifold & 5 ft. cable on panel 8=Peracetic acid sensor with flow manifold & 5 ft. cable on panel A=Free chlorine/bromine sensor, extended pH range with flow cell & 20 ft. cable B=Free chlorine/bromine sensor, extended pH range with flow cell & 5 ft. cable on panel WIND WebMaster® Industrial Water Controllers Walchem’s WebMaster Industrial (WIND) Controller sets a new standard for Industrial Water Treatment Controllers. WIND has a flexible multi-I/O platform, a wide range of analytical sensor measurement capabilities, and an extensive assortment of integrated communications and data handling features. AGENCY CERTIFICATIONS Safety EMC UL 61010-1:2012 3rd Ed. CSA C22.2 No. 61010-1:2012 3rd Ed. IEC 61010-1:2010 3rd Ed. EN 61010-1:2010 3rd Ed. IEC 61326-1:2005 EN 61326-1:2006 Walchem’s WebAlert is the first stand alone remote monitoring device that can web enable your installed equipment without having to replace or upgrade it. Designed to be flexible and versatile, the WDIS Series controller is the ideal solution for disinfection applications in cooling towers, food & beverage, drinking water, wastewater and swimming pools. Integrated datalogging is available to validate system performance. A USB memory stick is all that’s needed to extract data and event logs that include disinfection sensor measurements and relay status. Summary of Key Benefits Versatility for a Broad Range of Applications Choose from four standard industrial grade sensors in one controller (chlorine/bromine, chlorine dioxide, ozone, peracetic acid) or configure the controller to use a variety of other disinfection sensors. Relays can be configured for Hi Alarm, Low Alarm, Out-of-Range Alarm, In-Range Output or Probe Wash, providing unmatched flexibility. ABOUT US Walchem integrates its advanced sensing, instrumentation, fluid pumping and communications technologies to deliver reliable and innovative solutions to the global water treatment market. Our in-house engineering is driven by quality, technology and innovation. For more information on the entire Walchem product line, visit: www.walchem.com Note: For EN61000-4-6 & EN61000-4-3 the controller met performance criteria B. Economical and Simple to Use WDIS controllers are economically priced and do not require any costly reagents. The rugged NEMA 4X enclosure and panel mounted flow assembly has only two process connections for quick and easy installation. Built-in Safety Features Programmable output limit timers prevent run-away chemical addition. Digital Interlock Input may be used from a flow switch or level input to prevent chemical addition based on a stagnant sample, or control of an empty batch tank. The alarm relay notifies plant personnel of alarm conditions as soon as they occur. Simple, Integrated Data Collection Download stored data from the controller to a USB stick. Use the data to simply and easily validate system performance, document compliance and reduce liability. The data and event logs show disinfection levels, as well as accumulated chemical feed and relay activation times. *Class A equipment: Equipment suitable for use in establishments other than domestic, and those directly connected to a low voltage (100-240 VAC) power supply network which supplies buildings used for domestic purposes. 180374.O May 2014 The WDIS Series controller takes the guesswork out of your disinfection process. The chemical concentration is continuously monitored and controlled to the precise range required for proper system control and regulatory compliance. WebAlert® Remote Monitor USB FEATURES U=Integrated datalogging, event/reset logging, and configuration file import/export Note: Refer to the Disinfection Sensor brochure for additional sensor options. Order the WDIS controller with sensor option “N” then order the appropriate sensor separately. Walchem’s WDIS Series controller will reliably and economically control your water treatment disinfection process. The controller includes four standard sensor input options (free chlorine/bromine, chlorine dioxide, ozone, peracetic acid) or can be configured to use a variety of other types or ranges of Walchem disinfection sensors, such as hydrogen peroxide or total chlorine. Walchem, Iwaki America Inc. Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA Phone: 508-429-1110 www.walchem.com Features Specifications Versatile relay configuration • Control outputs can be set as high or low set points via keypad. Auxiliary outputs can be set as: • High alarm • Low alarm • In-range output • Probe wash • Out of range alarm Probe wash feature • For applications that require frequent electrode cleaning, automatic probe wash extends the time between maintenance interruptions Programmable access code • Secures set point parameters and prevents un- authorized use. Program any four digit access number or disable the code requirement. Display status at a glance • Look at any set point without interrupting control or entering an access code. Top level view: • Analog graph relative to set point • Disinfection sensor values • Status of alarms, outputs 19” Disinfection Controlle r 8.25” Self diagnostics • Software and electronics are constantly monitored without having to take the controller off-line. Any error messages are clearly displayed. A fifth relay is activated by any diagnostics failures. USB Flashstick Support • Standard for data logs, event/relay and reset logs, and user configuration file import/export Relatively insensitive to changes in sample flow rate Large openings in flow cell prevent clogging Integrated temperature compensation Excellent long-term stability Free Chlorine /Bromine Chlorine and Bromine are the most common disinfectants used in water treatment. They’re readily available, inexpensive, and typically used in drinking water, swimming pools, cooling towers and process water applications. Peracetic Acid Peracetic acid has been used for decades as a disinfectant in the food & beverage industry. Its use has grown to many other applications including bottling, CIP (Clean In Place), laundry, pulp & paper, and agriculture. Chlorine Dioxide Chlorine dioxide is a very strong oxidant that is often used for disinfection in drinking water, food & beverage, and cooling tower applications. It’s preferred for some uses since it doesn’t affect the taste and odor of the water being treated. Ozone Ozone is the strongest oxidant used in water treatment. it is commonly used in drinking water (disinfection, oxidation, taste and odor control), food & beverage, swimming pools (therapy pools), zoos and aquariums. USB Features Integrated datalogging collects analytical measurements at 10 minute intervals and captures all relay activations. Download Stored Data Copy user-defined settings Easily create charts and graphs that demonstrate system performance Programming a new controller is complete in seconds! Use stored data to validate system performance EXI T www.walchem.com 24” 19” 3.5” Mechanical (controller) Enclosure Polycarbonate NEMA Rating NEMA 4X (IP65) 2 x 16 character backlit liquid crystal Display Ambient Temperature 32 to 122°F (0 to 50°C) Shipping weight 26 lbs (11.8 kg) (approximately) 8” Inputs Sensor Specifications Input Power: 100-240 VAC, 50/60 Hz, 8A Fuse: 1.0 ampere, 5 x 20 mm Mechanical Operating Temperature Chlorine Dioxide, Ozone: 5 to 50°C (41 to 122°F) Chlorine/Bromine, Peracetic Acid: Input Signals: 5 to 45°C (41 to 113°F) Sensor ±2000 mV Operating pressure 0 to 1 atm (0 to 14.7 psi) Interlock (Optional) Isolated, dry contact closure required(i.e. flow, level) Storage Sensor: Frost-protected, dry and without electrolyte no limit at >5 to <40°C ( >41 to <104 °F) Membrane cap: Used membrane caps can not be stored! Electrolyte: in original bottle protected from sunlight min. 1 year at >5 to <25°C (>41 to <77°F) Outputs Control 1, Control 2 (On/Off): Two internally powered relays, 6A (resistive), 1/8 HP All relays are fused together as one group, total current for this group must not exceed 6A Flow cell inlet Flow cell outlet 4-20 mA 1 or 2: (optional) Sensor Power: Electrical Power requirements ±5 VDC, 5 mA maximum 0 to -2000 mVDC Signal Max cable length 305 m (1000 ft) Cable required 2 twisted pair, 24 AWG shielded, ±5VDC, 5 mA Cross sensivity Chlorine Dioxide Peracetic Acid Ozone Free Chlorine/ Bromine Free Chlorine/Bromine Extended pH Range 0-16.75 mg/l 0-1675 mg/l 0-16.75 mg/l 0-13.25 mg/l 0-12.50 mg/l 0.01 mg/l 1 mg/l 0.01 mg/l 0.01 mg/l 0.01 mg/l Free chlorine (5%) Ozone, ClO2 Ozone, ClO2 Free chlorine (5%), Ozone Flow rate of sample pH range of sample 30 to 100 liters/hr (7.9 to 26.4 gallons/hr 1.0 to 11.0 Conductivity range of sample Response time Sensor Body PVC, Polycarbonate,Silicone Rubber, PTFE, PEEK Flow cell bodyIsoplast O-ringFKM Internally powered, Fully isolated 600 Ohm max resistive load Resolution .001% of span Accuracy ± 1% of reading Resolution 1/4” NPTF 3/4” NPTF Materials of Construction Control 3, Control 4, Alarm: Dry contact relays, 6A (resistive), 1/8 HP Range Identify system upsets faster by knowing exactly what happened and when NEXT W A L C H E M Standard Disinfection Sensors | Free Chlorine/Bromine • Chlorine Dioxide • Peracetic Acid • Ozone Long-lasting amperometric electrode with rugged membrane PREV ENTER 1.0 to 7.0 2.0 to 11.0 50 to 10,000 µS/cm 30 seconds 3 minutes 30 seconds 6.8 to 8.0 4.0 to 12.0 Up to 4% NaCl 50 to 10,000 µS/cm 30 seconds 2 minutes Features Specifications Versatile relay configuration • Control outputs can be set as high or low set points via keypad. Auxiliary outputs can be set as: • High alarm • Low alarm • In-range output • Probe wash • Out of range alarm Probe wash feature • For applications that require frequent electrode cleaning, automatic probe wash extends the time between maintenance interruptions Programmable access code • Secures set point parameters and prevents un- authorized use. Program any four digit access number or disable the code requirement. Display status at a glance • Look at any set point without interrupting control or entering an access code. Top level view: • Analog graph relative to set point • Disinfection sensor values • Status of alarms, outputs 19” Disinfection Controlle r 8.25” Self diagnostics • Software and electronics are constantly monitored without having to take the controller off-line. Any error messages are clearly displayed. A fifth relay is activated by any diagnostics failures. USB Flashstick Support • Standard for data logs, event/relay and reset logs, and user configuration file import/export Relatively insensitive to changes in sample flow rate Large openings in flow cell prevent clogging Integrated temperature compensation Excellent long-term stability Free Chlorine /Bromine Chlorine and Bromine are the most common disinfectants used in water treatment. They’re readily available, inexpensive, and typically used in drinking water, swimming pools, cooling towers and process water applications. Peracetic Acid Peracetic acid has been used for decades as a disinfectant in the food & beverage industry. Its use has grown to many other applications including bottling, CIP (Clean In Place), laundry, pulp & paper, and agriculture. Chlorine Dioxide Chlorine dioxide is a very strong oxidant that is often used for disinfection in drinking water, food & beverage, and cooling tower applications. It’s preferred for some uses since it doesn’t affect the taste and odor of the water being treated. Ozone Ozone is the strongest oxidant used in water treatment. it is commonly used in drinking water (disinfection, oxidation, taste and odor control), food & beverage, swimming pools (therapy pools), zoos and aquariums. USB Features Integrated datalogging collects analytical measurements at 10 minute intervals and captures all relay activations. Download Stored Data Copy user-defined settings Easily create charts and graphs that demonstrate system performance Programming a new controller is complete in seconds! Use stored data to validate system performance EXI T www.walchem.com 24” 19” 3.5” Mechanical (controller) Enclosure Polycarbonate NEMA Rating NEMA 4X (IP65) 2 x 16 character backlit liquid crystal Display Ambient Temperature 32 to 122°F (0 to 50°C) Shipping weight 26 lbs (11.8 kg) (approximately) 8” Inputs Sensor Specifications Input Power: 100-240 VAC, 50/60 Hz, 8A Fuse: 1.0 ampere, 5 x 20 mm Mechanical Operating Temperature Chlorine Dioxide, Ozone: 5 to 50°C (41 to 122°F) Chlorine/Bromine, Peracetic Acid: Input Signals: 5 to 45°C (41 to 113°F) Sensor ±2000 mV 0 to 1 atm (0 to 14.7 psi) Operating pressure Interlock (Optional) Isolated, dry contact closure required(i.e. flow, level) Storage Sensor: Frost-protected, dry and without electrolyte no limit at >5 to <40°C ( >41 to <104 °F) Membrane cap: Used membrane caps can not be stored! Electrolyte: in original bottle protected from sunlight min. 1 year at >5 to <25°C (>41 to <77°F) Outputs Control 1, Control 2 (On/Off): Two internally powered relays, 6A (resistive), 1/8 HP All relays are fused together as one group, total current for this group must not exceed 6A Flow cell inlet Flow cell outlet 4-20 mA 1 or 2: (optional) Sensor Power: Electrical Power requirements ±5 VDC, 5 mA maximum 0 to -2000 mVDC Signal Max cable length 305 m (1000 ft) Cable required 2 twisted pair, 24 AWG shielded, ±5VDC, 5 mA Cross sensivity Chlorine Dioxide Peracetic Acid Ozone Free Chlorine/ Bromine Free Chlorine/Bromine Extended pH Range 0-16.75 mg/l 0-1675 mg/l 0-16.75 mg/l 0-13.25 mg/l 0-12.50 mg/l 0.01 mg/l 1 mg/l 0.01 mg/l 0.01 mg/l 0.01 mg/l Free chlorine (5%) Ozone, ClO2 Ozone, ClO2 Free chlorine (5%), Ozone Flow rate of sample pH range of sample 30 to 100 liters/hr (7.9 to 26.4 gallons/hr 1.0 to 11.0 Conductivity range of sample Response time Sensor Body PVC, Polycarbonate,Silicone Rubber, PTFE, SS, PEEK Flow cell bodyIsoplast O-ringFKM Internally powered, Fully isolated 600 Ohm max resistive load Resolution .001% of span Accuracy ± 1% of reading Resolution 1/4” NPTF 3/4” NPTF Materials of Construction Control 3, Control 4, Alarm: Dry contact relays, 6A (resistive), 1/8 HP Range Identify system upsets faster by knowing exactly what happened and when NEXT W A L C H E M Standard Disinfection Sensors | Free Chlorine/Bromine • Chlorine Dioxide • Peracetic Acid • Ozone Long-lasting amperometric electrode with rugged membrane PREV ENTER 1.0 to 7.0 2.0 to 11.0 50 to 10,000 µS/cm 30 seconds 3 minutes 30 seconds 6.8 to 8.0 4.0 to 12.0 Up to 4% NaCl 50 to 10,000 µS/cm 30 seconds 2 minutes Ordering Information Disinfection Controllers WDIS400 Series WDIS410U voltage output sensor Webmaster ONE ® USB WebMasterONE is the most advanced online cooling tower and boiler controller in the water treatment industry. The flexible multi-I/O platform allows you to control multiple cooling towers, boilers, closed loops, and condensate lines with just one controller. An extensive assortment of integrated communications and data handling features are included that enable water treatment professional to provide more effective water management services to their customers. VOLTAGE 1=120 VAC, prewired w/ USA power cord & 6” pigtails 5=Hardwired, cable glands OUTPUT N=No data output 4=One (1) Isolated 4-20 mA output 2=Two (2) Isolated 4-20 mA outputs Metering Pumps The E-Class is the most innovative and comprehensive metering pump product line in the world. Over 50 years of pump experience and a commitment to superior mechanical design has led to development of many industry firsts, including 360 stroke-perminute technology, IP67 waterproof construction, and the world’s highest capacity solenoid metering pumps. SENSOR (consult factory for other sensor types & ranges) N= No sensor 1=Free chlorine/bromine sensor with flow cell & 20 ft. cable 2=Chlorine dioxide sensor with flow cell & 20 ft. cable 3=Ozone sensor with flow cell & 20 ft. cable 4=Peracetic acid sensor with flow cell & 20 ft. cable 5=Free chlorine/bromine sensor with flow manifold &5 ft. cable on panel 6=Chlorine dioxide sensor with flow manifold & 5 ft. cable on panel 7=Ozone sensor with flow manifold & 5 ft. cable on panel 8=Peracetic acid sensor with flow manifold & 5 ft. cable on panel A=Free chlorine/bromine sensor, extended pH range with flow cell & 20 ft. cable B=Free chlorine/bromine sensor, extended pH range with flow cell & 5 ft. cable on panel WIND WebMaster® Industrial Water Controllers Walchem’s WebMaster Industrial (WIND) Controller sets a new standard for Industrial Water Treatment Controllers. WIND has a flexible multi-I/O platform, a wide range of analytical sensor measurement capabilities, and an extensive assortment of integrated communications and data handling features. AGENCY CERTIFICATIONS Safety EMC UL 61010-1:2012 3rd Ed. CSA C22.2 No. 61010-1:2012 3rd Ed. IEC 61010-1:2010 3rd Ed. EN 61010-1:2010 3rd Ed. IEC 61326-1:2005 EN 61326-1:2006 Walchem’s WebAlert is the first stand alone remote monitoring device that can web enable your installed equipment without having to replace or upgrade it. Designed to be flexible and versatile, the WDIS Series controller is the ideal solution for disinfection applications in cooling towers, food & beverage, drinking water, wastewater and swimming pools. Integrated datalogging is available to validate system performance. A USB memory stick is all that’s needed to extract data and event logs that include disinfection sensor measurements and relay status. Summary of Key Benefits Versatility for a Broad Range of Applications Choose from four standard industrial grade sensors in one controller (chlorine/bromine, chlorine dioxide, ozone, peracetic acid) or configure the controller to use a variety of other disinfection sensors. Relays can be configured for Hi Alarm, Low Alarm, Out-of-Range Alarm, In-Range Output or Probe Wash, providing unmatched flexibility. ABOUT US Walchem integrates its advanced sensing, instrumentation, fluid pumping and communications technologies to deliver reliable and innovative solutions to the global water treatment market. Our in-house engineering is driven by quality, technology and innovation. For more information on the entire Walchem product line, visit: www.walchem.com Note: For EN61000-4-6 & EN61000-4-3 the controller met performance criteria B. Economical and Simple to Use WDIS controllers are economically priced and do not require any costly reagents. The rugged NEMA 4X enclosure and panel mounted flow assembly has only two process connections for quick and easy installation. Built-in Safety Features Programmable output limit timers prevent run-away chemical addition. Digital Interlock Input may be used from a flow switch or level input to prevent chemical addition based on a stagnant sample, or control of an empty batch tank. The alarm relay notifies plant personnel of alarm conditions as soon as they occur. Simple, Integrated Data Collection Download stored data from the controller to a USB stick. Use the data to simply and easily validate system performance, document compliance and reduce liability. The data and event logs show disinfection levels, as well as accumulated chemical feed and relay activation times. *Class A equipment: Equipment suitable for use in establishments other than domestic, and those directly connected to a low voltage (100-240 VAC) power supply network which supplies buildings used for domestic purposes. 180374.P June 2014 The WDIS Series controller takes the guesswork out of your disinfection process. The chemical concentration is continuously monitored and controlled to the precise range required for proper system control and regulatory compliance. WebAlert® Remote Monitor USB FEATURES U=Integrated datalogging, event/reset logging, and configuration file import/export Note: Refer to the Disinfection Sensor brochure for additional sensor options. Order the WDIS controller with sensor option “N” then order the appropriate sensor separately. Walchem’s WDIS Series controller will reliably and economically control your water treatment disinfection process. The controller includes four standard sensor input options (free chlorine/bromine, chlorine dioxide, ozone, peracetic acid) or can be configured to use a variety of other types or ranges of Walchem disinfection sensors, such as hydrogen peroxide or total chlorine. Walchem, Iwaki America Inc. Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA Phone: 508-429-1110 www.walchem.com
© Copyright 2026 Paperzz