USER MANUAL POWERPACK PRIME SERIES 1 - 3 KVA UDD-SD-113/ Release Date: 26.12.2014/Rev No: 0/Rev. Date: 1 USER MANUAL POWERPACK PRIME SERIES 1 - 3 KVA UDD-SD-113 About The Manual This manual is prepared for the users of Powerpack Prime Series 1-3 kVA. Companion Manuals For further information about this device and its options, please visit www.makelsan.com.tr Updates Please visit www.makelsan.com.tr for updates. Always use the latest manuals. UDD-SD-113/ Release Date: 26.12.2014/Rev No: 0/Rev. Date: 2 POWERPACK PRIME SERIES 1-3 kVA CONTENTS CONTENTS 1 PRODUCT INTRODUCTION ........................................................................................................................................5 1.1 Function description .............................................................................................................................................5 1.2 Front Panel................................................................................................................................................................6 1.2.1 Front View .............................................................................................................................................................6 1.2.2 LCD and LED Display.........................................................................................................................................6 1.2.3 Button ......................................................................................................................................................................7 1.3 Rear panel .................................................................................................................................................................8 1.4 Mode description....................................................................................................................................................9 1.5 Product Specification ......................................................................................................................................... 11 1.5.1 Model description........................................................................................................................................... 11 1.5.2 Environment Specification ......................................................................................................................... 12 1.5.3 Mechanical Specification ............................................................................................................................. 12 1.5.4 Electrical Specification ................................................................................................................................. 13 1.6 Communication Port ......................................................................................................................................... 14 1.6.1 RS232................................................................................................................................................................... 14 1.6.2 Intelligent Card ................................................................................................................................................ 14 2 INSTALLATION............................................................................................................................................................. 15 2.1 Safety Instructions for Installation .............................................................................................................. 15 2.2 Unpacking and Inspection ............................................................................................................................... 16 2.3 Installation Steps for Standard Model ........................................................................................................ 16 2.4 Installation for Communication Software (Optional) .......................................................................... 16 3 OPERATION ................................................................................................................................................................... 17 3.1 Operation Safety Instructions ........................................................................................................................ 17 3.2 Start the UPS with mains (AC source) ........................................................................................................ 18 3.3 Start the UPS with battery (DC source) only............................................................................................ 18 3.4 Connect loads to UPS ......................................................................................................................................... 19 3.5 Charge the batteries ........................................................................................................................................... 20 3.6 Discharge the batteries ..................................................................................................................................... 20 3.7 Test the batteries................................................................................................................................................. 20 3.8 Turn off the UPS with mains (AC source).................................................................................................. 20 3.9 Turn off the UPS with battery (DC) only.................................................................................................... 21 UDD-SD-113/ Release Date: 26.12.2014/Rev No: 0/Rev. Date: 3 POWERPACK PRIME SERIES 1-3 kVA CONTENTS 4 MAINTENANCE ............................................................................................................................................................ 22 4.1 Maintenance Safety Instructions .................................................................................................................. 22 4.2 Typical Troubleshooting .................................................................................................................................. 24 4.3 Battery Maintenance .......................................................................................................................................... 25 4.4 Contact the service centre ............................................................................................................................... 26 5 TRAMSPORT and STORAGE .................................................................................................................................... 26 6 STANDARDS .................................................................................................................................................................. 26 7 GUARANTEE .................................................................................................................................................................. 27 7.1 Terms of Guarantee ............................................................................................................................................ 27 7.2 Cases Not Covered by the Guarantee .......................................................................................................... 28 8 CONTACT INFORMATION........................................................................................................................................ 32 UDD-SD-113/ Release Date: 26.12.2014/Rev No: 0/Rev. Date: 4 POWER RPACK PRIME SERIES 1--3 kVA 1 PR RODUC CT INT TRODU UCTION N 1.1 Fun nction description This product is a true onlline double-conversion n UPS (Unin nterruptiblee Power Su upply). It provides perfectt protection for critical load such as computer system. It ccan eliminatte almost all mains m power disturbances. The inpu ut AC curren nt can be corrected to a wave follow wing the main ns voltage, so it is a high h power facctor system. Through th he PWM con ntrol technology, the outpu ut voltage caan be a puree & stable sine wave AC C voltage. When n the mainss input beco ome abnorm mal, the con ntroller willl stop the A AC/DC and start s the DC/D DC section im mmediately y to make su ure the DC/A AC (inverterr) section caan continue to work. Afterr the mains input come back to norrmal range, the DC/DC will be stop pped and th he AC/DC work ks again. So the load is always pow wer-supplied d through in nverter with hout any intterrupt if the UPS U is turned d on. The UPS U also pro ovides an intternal bypasss path so th hat the load can be pow wered by maiins input direcctly when the UPS is off or failed. The UPS U is equip pped with an a internal charger c for batteries b wh hich chargess the batteriies when the mains m are wiithin a reaso onable rangee under “byp pass mode” or “line mod de”. 5 POWERPACK PRIME SERIES 1-3 kVA 1.2 Front Panel 1.2.1 Front View 1K 2K/3K 1.2.2 LCD and LED Display 6 POWERPACK PRIME SERIES 1-3 kVA LED definition There are total 4 LEDs to indicate the status of UPS. Name Colour Bypass LED Orange Line LED Green Inverter LED Green Battery LED Orange Function To indicate that the UPS is in bypass mode, and the load current is directly from the mains power. To indicate that the mains input is normal. To indicate that the load current is supplied from the mains power or battery via the inverter. To indicate that the UPS is in battery mode, and the load current is from battery via the inverter. 1.2.3 Button (1) ON/OFF button Turn on UPS Turn off UPS Clear fault status Press ON/OFF button for 1 second to turn on UPS. UPS would send a beep to indicate the power-on status Press ON/OFF button for 1 second to turn off UPS when UPS is in line mode or battery mode. Press ON/OFF button for 3 seconds to clear the fault status of UPS. (2) Test button Battery test Mute in battery mode Mute in all mode Page up/down In line mode, press test button for 2 seconds to test the battery. Press test button for 2 seconds in battery mode, UPS would be muted. To resume the alarm, press test button again for 2 seconds. Press test button for 10 seconds, UPS would be muted. To resume the alarm, press test button again for 10 seconds. The key tone and battery voltage under alarm (every second buzzer beep twice) cannot be muted. Press test button for 0.5 seconds, UPS would turn from main menu to sub-menu in sequence 7 POWERPACK PRIME SERIES 1-3 kVA 1.3 Rear panel 8 POWERPACK PRIME SERIES 1-3 kVA 1 2 3 4 Communication port (RS232) Intelligent card slot Fan Output socket 5 Mains input protection 6 7 Mains input power cord Output terminal block 1.4 Mode description Line mode Line mode means that the mains input is rectified/converted by the AC/DC section and then inverted to stable output by DC/AC section. In line mode, the output is well-regulated and good to the loads. If the mains get abnormal, the UPS will transfer to battery mode without interruption. In line mode, Line LED and Inverter LED are turned on constantly. Line mode 9 POWERPACK PRIME SERIES 1-3 kVA 1. If Line LED flashes, it means that the input may have something wrong, such as input L and N line reversed or the grounding wire is not connected properly. 2. If the load level is higher than 100%, the buzzer will beep once every 0.5 second as a warning for the over-loading condition. The user should remove unnecessary loads one by one, until the load level become lower than 100%. 3. If the Battery LED flashes, it means that the battery is not connected or the battery level is too low. In this case please check the connection of battery and press test button for 2 seconds to test the battery. If the connection is normal, it’s possible the battery is failed or aged. Please refer to the common troubleshooting table in chapter Connecting AC Generator as Input Remove the loads connected to UPS first. Activate the generator and connect the output of generator with the input of UPS until the generator operates stably, then turn on the UPS and add the loads one by one. Please choose the generator with output capacity which is twice larger than the UPS capacity. Battery mode Battery mode means that the battery power goes through the DC/DC section to the inverter (DC/AC) and output a stable backup power when the mains are failed. If the mains recovered, the UPS will transfer to line mode without interruption. In battery mode, Battery LED and Inverter LED are turned on constantly. If Line LED flashes at the same time, it means that the input mains are abnormal. Battery mode 1. In battery mode, Buzzer beeps once every 4 seconds. Press test button for 2 seconds in battery mode, UPS would be muted. To resume the alarm, press test button again for 2 seconds. 2. When the voltage of battery decline to the lower limit, buzzer beeps once every second to warn the low battery status and remind user to turn off the loads. 3. User may check the backup function by turning on the UPS without connecting the mains input. 10 POWER RPACK PRIME SERIES 1--3 kVA Bypa ass mode Bypass mode mean ns that the UPS U providees the power through th he internal bypass path h to load y regulation n. If the controller detectts the mainss is abnormaal, it will shu ut off the directly without any output to protect the load. The T bypass voltage/freequency ran nge and deefault outpu ut status (on/off)) could be seet by software tool. In bypasss mode, Lin ne LED and Bypass LED D are turned d on constan ntly. Buzzerr beeps oncee every 2 minutess. B Bypass mod de 1. If Lin ne LED flash hes, it meanss that the in nput may haave somethin ng wrong, su uch as inputt L and N line reversed or o the groun nding wire iss not conneccted properlly. 2. The description d of other LED Ds is the sam me as line mode. m 3. UPS’ss backup fun nction is nott enabled un nder bypass mode. 1.5 Pro oduct Speccification 1.5.1 Model M desccription Thiss manual is applicable a to o the follow wing models:: Mo odel name 1K 2K 3K VA/1600W 3000VA/24 400W Pow wer rating 1000VA/800W 2000V 11 POWERPACK PRIME SERIES 1-3 kVA 1.5.2 Environment Specification Model Operating Temperature Storage Temperature 1K Noise Level 3K 0-40°C -25-55°C <1000m @ full load <2000m @ 91%load <3000m @ 82%load <4000m @ 74%load Altitude Relative Humidity 2K 20%-90% <45dB @ 1 meter from front panel <50dB @ 1 meter from front panel 1.5.3 Mechanical Specification Model Dimension (W×H×D) (mm) Weight (Kg) 1K 2K 3K 144×229×345 190×328×393 190×328×393 9.2 17.2 22.6 12 POWERPACK PRIME SERIES 1-3 kVA 1.5.4 Electrical Specification Model 1K 2K 1000VA/800W Power 3K 2000VA/1600 3000VA/2400 W W Input Current (Max.) Voltage Range 5A 14.3A 80VAC-285VAC(Default 180-264VAC) Frequency Range Input Factor 10A 40-70Hz Power ≧0.98 @ full load Output Voltage Frequency 200*/208*/220/230/240VAC (sine-wave) Synchronizing mains input @ line mode 50/60Hz ± 0.05 Hz @ battery mode Voltage Regulation Overload Capacity ± 2% 47s~25s linear @ 105%~150%; 25s~300ms linear @150%~200%; >200% : 200ms Efficiency Line Mode 89% 90% 90% Battery Mode 83% 83% 83% Battery & Charger @ 25C Total battery 24Vdc 48Vdc 72Vdc rating voltage Backup Time (Full >4.5min >4.5min >4.5min Load) Recharge Time (to <7Hours <7Hours <7Hours 90%) Charging Current 1A 1A 1A (Max.) Discharging 53A 53A 53A Current (Max.) Rated Charging 27Vdc54Vdc81VdcVoltage 27.6Vdc 55.2Vdc 82.2Vdc *: If the rating output voltage is 200/208VAC, the rating power will be decreased to 90%. *. Can’t support half wave load. 13 POWERPACK PRIME SERIES 1-3 kVA 1.6 Communication Port 1.6.1 RS232 The communication port (RS232) is for the connection with PC which is installed with monitoring software. Pin assignment of the DB-9 connector is shown below: Pin# Definition 2 TXD (output) 3 RXD (input) 5 GND 1.6.2 Intelligent Card Intelligent card - AS400 card, NMC card and CMC card are optional. The intelligent card is inserted into intelligent card slot. a- AS400 card: Monitor the UPS by using the AS400 management function if the system has AS400 interface. b- NMC card: Communication with the PC via internet for remote monitoring and control of the UPS. c- CMC card: a centralized-control card for remote monitoring NOTE Please contact with distributor or service center for detail information about intelligent cards. 14 POWER RPACK PRIME SERIES 1--3 kVA 2 INSTALL LATION N 2.1 Safe fety Instructions for Installatio on Please read the following f safety instru uctions beffore installa ation! Insta allation Perrsonnel Th his product must be insstalled only by qualified or professional pe ersonnel acccord to safetty instructio ons! allation Env vironment Insta Do not installl and operaate the UPS if there is water D w condeensation which may occcur if the UPS is moved m suddeenly from a cold environment to a warm one. The T UPS mu ust be absolu utely dry before being b installed and opeerated. Pleaase allow an n acclimatizzation time of at least 2 hours. Otherwiise hazard of o electric sh hock may exiist! Do not installl the UPS in D n the environ nment wherre it is damp p or would b be exposed to direct sunlightt or heat. En nsure the UP PS is far away from wateer, inflammaable gas and d corrosive agents. a Do not block D k the air ven nts on the ho ousing of UP PS. The UPSS must be in nstalled in a location with goo od ventilatio on. Ensure enough e spacce on each siide for ventiilation. Wiring & Groun nding In nstallation and a Wiring must be peerformed in n accordance with the local electriical laws and regu ulations. T UPS mu The ust be securrely grounded. If there are externaal UPS battery cabinets, please make su ure the batteery cabinetss have the eq quipotentiall earth bond ding to the U UPS main cab binet. D not conneect Input N wire Do w and outtput N wire together. An approprriate switch device as backup pro A otection forr over-curreent or shorrt-circuit should be b provided in the inputt mains. 15 POWER RPACK PRIME SERIES 1--3 kVA B Battery SStrictly follow w the princciple of “sam me voltage, same s type” when connecting multi battery packs in n parallel. D breaker or DC o fuse mustt be used as a protection n device bettween the exxternal batttery pack and the UPS. The sp pecification of o protections must match the UPS’s specificattion. packing an nd Inspectiion 2.2 Unp 1. Unpaack the pack kage and cheeck the contents. The sh hipped packaage containss: 1 UPS 1 user manu ual 2. Inspeect the appeearance of th he UPS to seee if there iss any damagge during traansportation n. Do not turn on the unit and d notify the dealer immediately if th here is any damage d or laack of somee parts. eps for Stan ndard Mode el 2.3 Insttallation Ste 1. Makee sure the wire w / circu uit breaker / socket are enough fo or the curreent rating of o UPS to avoid d the hazard ds of electricc shock and fire. 2. Makee sure the mains m switch h in the build ding is switcched off. 3. Makee sure the UPS is not turrned on befo ore wiring operation. o 4. Turn off all loads firstly beforre connectingg to the UPS.. 5. Makee sure the prrotective earth ground is correctly connected. 6. Conn nect the load ds to the UPSS through th he outlet socckets. 7. Conn nect the inpu ut power corrd of UPS to o mains. 2.4 Insttallation forr Communiication Softtware (Optiional) 1. Conn nect the com mmunication n cable betw ween UPS and d PC. 2. Pleasse refer to th he guide maanual of softtware or con ntact the serrvice centerr for installaation and operaation of man nagement (m monitoring)) software. 16 POWER RPACK PRIME SERIES 1--3 kVA 3 OP PERAT TION 3.1 Ope eration Sa afety Instru uctions Please e read the following f safety instru uctions beffore operatiion! Operration personnel Th he product is designed to t be operated by gene eral users. Operration warn ning Do not disco D onnect the earth e wire on o the UPS or o the wirin ng terminalss of groundiing point at any timee since this would resu ult in the vo oid of proteective earth for the UPS S and all connected loads. l Do not try to disasssemble the original part p of the UPS beforre turning off and disconnectiing it from th he mains po ower & exterrnal battery y. The UPS ou utput sockett may be eleectrically liveed even if th he UPS systeem is not co onnected to the mains power sou urce. Make sure no liquid orr foreign objects enter th he UPS. Turn off th he mains inp put switch and external battery swiitch immediiately in the event of electric sho ock or fire closed c to thee UPS. 17 POWERPACK PRIME SERIES 1-3 kVA 3.2 Start the UPS with mains (AC source) 1. Press the on/off button of the UPS front panel continuously for more than 1 second. The buzzer will beep once, the numeric area of LCD display will be lighted in sequence, after a few seconds of self-diagnosis, the UPS will be turned on in normal mode (line mode) and feed the output power with constant AC voltage, if the mains abnormal, UPS will shift into battery mode after self-diagnosis. 2. When the UPS enters line mode normally, the Inverter LED will be on, the Bypass LED and Battery LED will be off. There will be no beep from buzzer. 3. Press the battery test button for 0.5 second, UPS will show the information on LCD display as followings in a circular order. 3.3 Start the UPS with battery (DC source) only 1. This UPS can be started directly with DC source (battery), without AC source. 2. Press the on/off button of the UPS front panel continuously for more than 1 second. The buzzer will beep once, the numeric area of LCD display will be lighted in sequence, after a few seconds of self-diagnosis, the UPS will be turned to the battery mode and feed the output power with constant AC voltage. 18 POWERPACK PRIME SERIES 1-3 kVA 3. When the UPS enters battery mode normally, the Inverter LED, and Battery LED will be on, the Bypass LED will off. 4. Press the battery test button for 0.5 second, UPS will show the information on LCD display as followings in a circular order. 5. To remind, UPS is under battery mode, it would send out beep once per 4 seconds, and user can enable/disable the buzzer by pressing battery test button for 2 seconds. Note: If the UPS shuts down in battery mode automatically, it will resume to line mode automatically when the mains power is recovered. 3.4 Connect loads to UPS After turning the UPS on, the loads can be switched on, and it is recommended to switch on the loads one by one. 1. If it is necessary to connect the inductive load such as a printer to the UPS, the start-up power should be considered for determining the capacity of the UPS because the power consumption for inductive load during start-up could be large. 2. If the UPS is overloaded, the buzzer will beep twice every second as warning. 3. If the UPS is overloaded, some loads must be switched off or decreased immediately. It is recommended that the total loads connected to the UPS be less than 80% of UPS’s nominal output power rating to prevent the overloading during transient time and make the system more satiable. 4. If the overloading time is too long in line mode, the UPS will transfer to bypass mode. After the overloading disappeared, it will return to line mode. If the overloading time is too long in battery mode, the UPS will cut off the output and then shutdown according battery level 19 POWERPACK PRIME SERIES 1-3 kVA 3.5 Charge the batteries 1. When the UPS is connected to normal mains, the charger will start to work and charge the batteries automatically. 2. It is suggested to charge the batteries for 10 hours at least before the UPS performs battery mode. Otherwise the backup time may be less than the expected value. 3.6 Discharge the batteries 1. When the UPS is in battery mode, the buzzer will start beep according to different battery level. If the battery voltage drops to the alarming level, the buzzer will start beep rapidly (once every sec) to remind the user that the capacity of battery is too low and the UPS will be shutdown automatically soon. The user may switch off some non-critical loads to avoid the shutdown alarming and prolong the backup time. If no more non-critical loads can be switched off at that time, it’s better to shut down rest loads as soon as possible to protect the important loads or save data. Otherwise there might be a risk of data loss or damage loads by power interrupted after batteries discharged. 2. If the user found the buzzer is noisy under battery mode, the beep could be muted by pressing the test button for 2 seconds. 3. The backup time may vary from different environmental temperature and load type. 3.7 Test the batteries 1. The user may check the battery level or aging status when the UPS is under normal mode (line mode) by pressing test button for 2 seconds to enter battery test mode. 2. To make the system more reliable, the UPS will automatically perform battery test on regular basis. The default period is once per 90 days. 3. The battery test could be performed by sending command from monitoring software through the communication port. 4. If the UPS enters the battery test mode, the buzzer will beep once, and Line/Bypass/Inverter/Batter LEDs will be on and off one by one, which allows the user to check the battery level in this mode. 3.8 Turn off the UPS with mains (AC source) 1. To turn off the UPS, please press the ON/OFF button continuously for more than 1 second. 2. After pressing the button, UPS will have no output. If the mains power is normal, the Line LED will turn on. If there is no mains power, 10 seconds later, the numeric area of LCD display will be lighted in sequence, finally all the LCD and LED will be blackout, and UPS shutdown completely. Note 1: If the UPS’s bypass mode is enabled, the output socket will still have voltage directly from mains power after switching the UPS off. Note 2: There is a risk of power interruption for the loads if the UPS works in bypass mode. 3. To turn off the output of UPS and shut down the UPS completely, it is recommended the mains power of UPS shall be disconnected. Note: please make sure all the loads are prepared or turned off before shutting down the UPS. 20 POWERPACK PRIME SERIES 1-3 kVA 3.9 Turn off the UPS with battery (DC) only 1. To turn off the UPS in battery mode, please press the ON/OFF button continuously for more than 1 second. 2. After pressing the ON/OFF button, the buzzer will sound beep once. The numeric area of LCD display will be lighted in sequence, finally all the LCD and LED will be blackuot, and UPS shutdown completely Note: please make sure all the loads are prepared or turned off before shutting down the UPS. 21 POWER RPACK PRIME SERIES 1--3 kVA 4 MA AINTENANCE E 4.1 Maintenance e Safety Insstructions Please e read the following f sa afety instru uctions befo ore mainten nance! ntenance Pe ersonnel Main This product p mu ust be main ntained onlly by qualiffied professsional perssonnel acco ord to safety y instruction ns! k of electric shock Risk d to the maains power or not, thee output may m have No matter the UPS iss connected T parts (b battery, capaacitor) insid de the unit may m still havve hazardouss voltage electricity. The after turnin ng off the UP PS. Make sure to disconneect the batteeries beforee carrying out o any kind d of mainten nance or repair. The battery may y result in ellectrical sho ock. Verify that no voltage between th he battery teerminals an nd the groun nd is presen nt before maintenancce or repair. In this pro oduct, the baattery circuiit is not isollated from the t input voltage. Hazzardous volttages may occur o betweeen the batteery terminals and the grround. Verify thaat no hazarrdous voltaage exists in the eneergy storagge capacitorr before maintenance or repairr. Remove alll jewellery y, wristwatcches, rings and other metal perssonal goodss before maintenancce or repair. Only use tools with insu ulated gripss and handlees when maiintaining or repairing. 22 POWER RPACK PRIME SERIES 1--3 kVA Batte ery CAUTIION: Only qualified q personnel can replace r the batteries! b A batttery can pre esent a risk of electrica al shock and d high shorrt circuit currrent. The following f precau utions should be observe ed when working on battteries. a) b) c) d) e) f) Remove watches, w rings or other metal m objects. Use tools with w insulate ed handles. Wear rubb ber gloves an nd boots. Do not lay tools or mettal parts on top of batterries. Disconnecct the chargin ng source prrior to conne ecting or dissconnecting b battery term minals. Determine e if battery y is inadverrtently grou unded. If in nadvertently y grounded, remove source fro om ground. Contact C with h any part off a grounded d battery ca an result in electrical e shock. The e likelihood of such sho ock can be re educed if su uch grounds are remove ed during installation and mainttenance (applicable to equipment e a and remote battery supplies not pply circuit). having a grrounded sup ositive and negative n of the t battery electrode. B Batteries hav ve a high Do not short the po nt and may cause a risk k of serious shock s or firee. short-circuit curren c th he batteries,, replace them with the same quaantity and the t same When changing type of batteries. d the batteries by y burning th hem as it could cause exxplosion. Do not attempt to dispose d according to lo ocal regulatio on. The battteries mustt be rightly deposed Do not open o or desttroy the battteries. Effluent electrollyte can cause injury to the skin and eyess and may be toxic to th he environm ment. Do not dispose d of baatteries in a fire. The batteries may explode. Fuse e Please rep place the fuse only with h a fuse of the same typ pe and of the same amp perage in order to avoid a fire haazards. 23 POWERPACK PRIME SERIES 1-3 kVA 4.2 Typical Troubleshooting If the LCD display shows any abnormal code, and the buzzer is alarming, that means UPS is running under abnormal status; please firstly analyze and resolve the problem by using ”The common troubleshooting table”, if the problem can’t be solved, please contact with distributor or service center. The abnormal codes include warning codes and fault codes: A: Fault code shown as right picture below for example. All the Fault codes begin with capital ‘F’ character. B: Warning code shown as left picture below for example. All the warning codes begin with capital ‘A’ character. The common troubleshooting table: Warning/f Buzzer alarm Signification ault code Decide by other A04 Line abnormal warning Beep every 2 L/N connection A07 minute reverse Decide by other A08 Bypass abnormal warning Beep every 1 Battery abnormal A10 second or disconnect A11 A12 A15 A16 A18 F01 F02 Correction method Input line abnormal, wait for line resume Please check L/N and the ground connection is OK Input line abnormal, wait for line resume Please check battery connection is OK Beep every 1 second Battery voltage low Please re-charger battery before use, if battery damaged, please contact to service people Continuously beep Beep every 1 second Beep every 1 second Continuously beep Continuously beep Continuously beep Battery voltage over charged Belong to UPS normal protection behavior Overload warning Fan abnormal Please check the power connected to UPS, and load off the unnecessary device Please contact the distributor or service center Charger abnormal Bus Soft Start up fail Bus voltage too high Please contact the distributor or service center 24 POWERPACK PRIME SERIES 1-3 kVA F03 F05 F06 F07 F08 F10 Continuously beep Continuously beep Continuously beep Continuously beep Continuously beep Continuously beep Bus voltage to low Bus short Inverter Soft Start up fail Inverter voltage too high Inverter voltage too low Output short F22 Continuously beep Overload fault F23 Continuously beep Over temp fault F29 F55 F57 F59 F62 Continuously beep Continuously beep Continuously beep Continuously beep Continuously beep Load off the unnecessary device, make sure the load power lower than the rating power Please make sure the intake wasn’t blocked, and the indoor temp wasn’t to high Converter fail NTC open Battery damaged Please contact the distributor or service center Battery over charged Inverter capacitor open 4.3 Battery Maintenance 1. The battery used for standard models are valve regulated sealed lead-acid maintenance free battery. It shall be charged regularly in order to maximize the expected life for the battery. When being connected to the mains power, whenever the UPS is turned on or not, the UPS keeps charging the batteries and also offers the protective function of overcharging and overdischarging. 2. The UPS shall be recharged once every 4 to 6 months if it is not going to be used for a long time. 3. In the regions with hot climates, the battery should be recharged/ discharged every 2 months. The recharging time should be >12 hours. 4. In normal conditions, the battery life lasts 3 to 5 years. If the battery is found in bad condition, earlier replacement is recommended. 5. Do not replace the battery individually. All batteries must be replaced at the same time following the instructions of the supplier. 25 POWERPACK PRIME SERIES 1-3 kVA 4.4 Contact the service centre When contact with distributor or service center for troubleshooting, please provide the following information: 1. Model name of product 2. Serial number of product 3. The date when the problem found 4. LCD display status 5. Buzzer alarm status 6. Mains power condition 7. Load type and capacity 8. Environment temperature, ventilation status 9. Other information for complete description of the problem 5 TRAMSPORT and STORAGE Please transport the UPS only in the original packaging. The UPS must be stored in the room where it is ventilated and dry. 6 STANDARDS * Safety EN 62040-1 * EMI Conducted Emission..........................:EN 62040-2 Category C2 Radiated Emission.............................:EN 62040-2 Category C2 Harmonic Current...............................:EN 61000-3-2 Voltage Fluctuation and Flicker..........:EN 61000-3-3 *EMS ESD...................................................:EN 61000-4-2 Level 4 RS.....................................................:EN 61000-4-3 Level 3 EFT....................................................:EN 61000-4-4 Level 4 SURGE..............................................:EN 61000-4-5 Level 3 CS…………………………………..…..:EN 61000-4-6 Level 3 MS………………………………….….. EN 61000-4-8 Level 3 Voltage Dips………………………..…: EN 61000-4-11 Low Frequency Signals.....................:EN 61000-2-2 26 POWERPACK PRIME SERIES 1-3 kVA 7 GUARANTEE 7.1 Terms of Guarantee Our products are under a two-year guarantee starting from the date of delivery against malfunctions resulting from production, material and workmanship faults. Malfunctions due to such type of faults will be removed without claiming any price of workmanship or spare parts to be replaced. Whether aforementioned malfunctions originate from usage faults or not are determined with a report to be issued by service stations, if there exists no service stations, by one of seller, dealer, agency, representative, importer or manufacturer or producer of those products respectively. Repair time of defective products is twenty business days at most. This period starts from the date when products are delivered to one of seller, dealer, agency, representative, importer or one of manufacturer or producer. Provided that products break down within the period of guarantee, the time passing during the repair process is added to the guarantee time. Provided that faults of products cannot be removed within ten business days, manufacturer-producer or importer is obliged to assign another product having similar features for the use of consumers until the faulty product has been repaired. Even though consumers exercise their repair rights, they can claim free replacement of products, refund or price discount at the rate of faultin the events; That, besides, the product,as of the date when the product is delivered to the consumer, breaks down four times a year or six times within the guarantee period to be determined by the manufacturer-producer and/or importer at least, on the condition of being in guarantee period, such malfunctions perpetuate passing over; That maximum time required for the repair of products is exceeded; That repair of the malfunction is determined as impossible through a report to be issued by service station, if there exists no service station, one of seller, dealer, agency, representative, importer or manufacturer or producer of the company respectively. The consumer is, on demand, obliged to submit guarantee certificate in terms of repairs or replacements within the scope of guarantee. It is essential that you definitely perform damage control over external packaging before receiving the products to be sent through freight. In the event of any damage, delivery person must be made to prepare a “damage determination record”. (For example; duringthe delivery process, the product has been checked and seen that is damaged.) 27 POWERPACK PRIME SERIES 1-3 kVA After the damage determination record has been issued, we request you to inform the MAKELSAN head office of the case. Products to be received from freight by signature means that products have been received completely and without no damage. Repairs of plug-and-play products in the places where no service point is around are performed in the factory of MAKELSAN or the nearest service point according to the direction to be made by the MAKELSAN head office. Defective product is delivered by hand to the nearest service point or to the contracted freight company in its original packaging to be sent to the factory of MAKELSAN according to the direction to be made by the MAKELSAN head office. For malfunctions in the scope of guarantee, shipment fees are under the responsibility of MAKELSAN on the condition that products are delivered to the contracted freight company. The device must be sent as packed in its original packaging as long as it is not desired by the service. Original packaging of devices should be preserved in order to use them for shipment of devices in terms of repairs to occur. Otherwise, no responsibility is assumed with regards to any troubles to be experienced. All defective products to be delivered by hand or through freight are to meet the necessary shipment requirements. (Anti-static protective, bubble wrap or box etc.)It is essential that legible barcode serial number belonging to the product be on the product. Otherwise, it is not covered in the scope of the guarantee. It is essential that products to be sent through freight definitely be together with delivery note, and that serial/model/malfunction details be written on delivery note to be sent (for example, breakdown report form), and that packaging content match with the products specified in the delivery note. Otherwise, freight is not accepted. The use of theGuarantee Certificate, submitted together with products with MAKELSAN trademark,is permitted by the T.R. Ministry of Industry and Commerce and General Directorate of Protection of Competition with no……. in accordance with the law, with no. 4077, and the notification, with no. TRKGM-95/116-117, issued basing the aforementioned law. MAKELSAN acknowledges and undertakes to obey the liabilities determined by the laws and legislations. 7.2 Cases Not Covered by the Guarantee Breakdowns resulting from the use of products contrary to the issues or the environment conditions (temperature, humidity etc.) specified in the user manual are not covered in the scope of guarantee. Damages and breakdowns resulting from the use of software, hardware, interface, accessories or consumables apart from those used together with products or recommended ones; changing place, wrong and insufficient maintenance, calibration or use; its operation contrary to environment specifications published for products; insufficiency of air installation; use of products in ambient having excessive humid or temperature; its operation in environment harmful for electrical circuits and abrasive; 28 POWERPACK PRIME SERIES 1-3 kVA and accidents, impacts, electric, shipment, natural disasters, not limited to the ones listed above, are not covered in the scope of product guarantee. In the general examination performed during the breakdown acceptance process, certain troubles causing products not to be covered in the scope of guarantee might not be understood. Provided that such faults come up in the detailed examination to be performed via technical service equipment, products are returned to customers. Products not covered in the scope of guarantee can, on demand of customer, be treated in a fee-paying way within the bounds of possibilities of the authorized service. Products out of the scope of guarantee, repairs of which are not possible are returned to customers. Damages and breakdowns resulting from treatments, internally or externally tampering, efforts to repair and spare part replacement of products, without approval of MAKELSAN, and those resulting from treatment of unauthorized service/dealer/person/establishment, are not covered in the scope of guarantee. Breakdown, cracks, scratches and wear, corrosion and dust to occur in time and by use in the outer surfaces of products (cabinet, cover, and front panel) are not covered in the scope of guarantee. In the event that original serial numbers, guarantee labels and stamps on products are removed or distorted, products are not covered in the scope of guarantee. No guarantee is issued against the use of products for any other purpose, apart from those specified in introduction or manual of products. Shelf lives of VRLA batteries are 6 months under the ambient temperature of 15 °C and 3 months under the ambient temperature of 25 °C. It is compulsory that systems to be purchased be commissioned within 3 months. 29 POWERPACK PRIME SERIES 1-3 kVA CERTIFICATE OF GUARANTEE Certificate Approval Date Certificate No MANUFACTURER COMPANY : --/--/---: TITLE ADDRESS : : MAKELSAN MAKİNE KİMYA ELEKTRİK SAN. TİC. A.Ş. Deri Organize SanayiBölgesi 2.Yol I-5 Parsel P.K. 34957 TELEPHONE : 0216 – 428 65 80 FAX : 0216 – 327 51 64 TYPE : _______________________________________________ TRADEMARK : _______________________________________________ MODEL : _______________________________________________ SERIAL NO / BANDEROLE : _______________________________________________ DELIVERY DATE AND PLACE : _______________________________________________ MAXIMUM REPAIR PERIOD : 20 business days GUARANTEE PERIOD : _______________________________________________ TITLE : _______________________________________________ ADDRESS : _______________________________________________ TELEPHONE : _______________________________________________ FAX : _______________________________________________ INVOICE DATE / NO : _______________________________________________ DATE / SIGNATURE AND STAMP : _______________________________________________ SIGNATURE AND STAMP OF COMPANY AUTHORITY OF THE PRODUCT VENDOR CUSTOMER TITLE / NAME : _______________________________________________ ADDRESS : _______________________________________________ SIGNATURE : _______________________________________________ UPS AUTHORIZED SERVICES İstanbulDeri Organize SanayiBölgesi 2. Yol I-5 Parsel 34956 Tuzla/İstanbul Tel: 0216 428 65 80 Fax: 0216 327 51 64 [email protected] www.makelsan.com.tr PZ-FR-07 (R2) Revision Date: 19.03.2014 30 CERTIFICATE OF GUARANTEE 1 – Guarantee period starts from the delivery date of the product and lasts………..years. 2 – The whole product, including all its parts are under the guarantee of our company. 3 – Provided that the product breaks down within the period of guarantee, the time passing during the repair process is added to the guarantee time. Repair time of the product is ……. business days at most. This period starts from the date when the malfunction related to the product is informed to the service station, if there exists no service station, to one of seller, dealer, agency, representative, importer or one of manufacturer. Provided that the fault of industrial product cannot be removed within 10 business days, manufacturer or importer is obliged to assign another industrial product having similar features for the use of the consumer until the faulty product has been repaired. 4 – Provided that the product breaks down due to materials and workmanship or assembly faults within the period of guarantee, the product is repaired without claiming any charge for workmanship, any price for spare part replacement or any fee under any name. 5 – The product will be replaced without any charge in the events; - - That passing over the product perpetuates due to the fact that the product repeats the same malfunction more than twice or different malfunctions occur more than four times in a year starting from the delivery date, on the condition of being in guarantee period; That maximum time required for the repairment of the product is exceeded; That, if there exists no service station, the repair of the malfunction is determined as impossible through a report to be issued one of seller, dealer, agency, representative, importer or manufacturer of the product respectively. 6 - Malfunctions resulting from the use of the product contrary to the issues specified in the user manual of the product are not covered in the scope of guarantee. 7 –For any trouble that may come up in terms of the Certificate of Guarantee, the Ministry of Industry and Commerce, General Directorate of Protection of Consumer and Competition can be applied. NOTICE 8 – Under no circumstances shall the customer treat the product with the aim of repair, apart from MAKELSAN authorized service personnel. 9 – Damages and results originating from the violation of the 8th Article shall be invoiced to the customer. The use of herein the certificate is permitted by the T.R. Ministry of Industry and Commerce and General Directorate of Protection of Consumers and Competition in accrordance with the Law on the Protection of Consumers, with no. 4077, and the Notification Concerning the Application Principles of Guarantee Certificate, issued basing the aforementioned law. POWERPACK PRIME SERIES 1-3 kVA CONTACT INFORMATION 8 CONTACT INFORMATION www.makelsan.com.tr Headquarter: İstanbul Deri Organize Sanayi Bölgesi 2. Yol I -5 Parsel 34956 Tuzla/ İstanbul Tel : 0216 428 65 80 Fax : 0216 327 51 64 E-mail : [email protected] İzmir Office : Halkapınar Mah. 1348 Sok. 2AE Keremoğlu İş Merkezi Yenişehir – İzmir Tel : 0232 469 47 00 Fax : 0232 449 47 00 E-mail : [email protected] Ankara Office : Mustafa Kemal Mah. 2157 Sok. No:4/6 Çankaya-Ankara Tel : 0312 219 82 35/37 Fax : 0312 219 82 36 E-mail : [email protected] www.makelsan.com.tr Headquarter: İstanbul Deri Organize Sanayi Bölgesi 2. Yol I -5 Parsel 34956 Tuzla/ İstanbul Tel : 0216 428 65 80 Fax : 0216 327 51 64 E-mail : [email protected] İzmir Office : Halkapınar Mah. 1348 Sok. 2AE Keremoğlu İş Merkezi Yenişehir – İzmir Tel : 0232 469 47 00 Fax : 0232 449 47 00 E-mail : [email protected] Ankara Office : Mustafa Kemal Mah. 2157 Sok. No:4/6 Çankaya-Ankara Tel : 0312 219 82 35/37 Fax : 0312 219 82 36 E-mail : [email protected]
© Copyright 2026 Paperzz