19 CP-1475 - Add patient defined term for Ultrasound Acquisition Geometry 1 Status Sep 2015 Votinng Packet 2 Date of Last Update 2015/06/19 3 Person Assigned David Clunie 4 5 Page 1 mailto:[email protected] Submitter Name 6 David Clunie mailto:[email protected] 7 Submission Date 8 Correction Number CP-1475 9 Log Summary: Add patient defined term for Ultrasound Acquisition Geometry 10 Name of Standard 11 PS3.3 12 Rationale for Correction: 13 14 The Enhanced US Volume object added an Ultrasound Frame Of Reference Module with a descriptive term describing the characteristic of the ultrasound acquisition geometry. 15 16 It is useful to be able to identify when the geometry is patient relative, to signal that the geometry is the same as the patient-relative coordinate system. 17 Correction Wording: 18 2015/02/27 - Sep 2015 Votinng Packet - 57 CP-1475 - Add patient defined term for Ultrasound Acquisition Geometry 1 Amend DICOM PS3.3 as follows (changes to existing text are bold and underlined for additions and struckthrough for removals): 2 C.8.24.2 Ultrasound Frame of Reference Module 3 Table C.8.24.2-1 specifies the attributes of the Ultrasound Frame Of Reference Module. See ???. Table C.8.24.2-1. Ultrasound Frame of Reference Module Attributes 4 5 Page 2 Attribute Name Tag Type Attribute Description 6 7 Volume Frame of Reference UID (0020,9312) 1 Uniquely identifies this Volume Frame of Reference. 8 21 9 Ultrasound Acquisition Geometry (0020,9307) 1 Characteristic of the ultrasound acquisition geometry. Defined Terms: 10 11 12 13 14 APEX PATIENT there exists an apex of the scan lines from which the volume data was acquired. the ultrasound acquisition geometry is patient relative 15 Note 16 17 18 19 20 When the value is PATIENT, the Plane Position (Patient) and Plane Orientation (Patient) functional group macros will be present, and will contain attributes with identical values to the corresponding attributes in the Plane Position (Volume) and Plane Orientation (Volume) functional group macros. 22 23 24 25 26 Apex Position (0020,9308) 1C 27 28 55 29 Position of the apex (or phase center) of the acquisition geometry, encoded as xA, yA, and zA in mm units in the Volume Frame of Reference. The apex (xA, yA, zA) may be located in the volume or exterior to it. Required if value of Ultrasound Acquisition Geometry (0020,9307) is APEX. Volume to Transducer Relationship (0020,930B) 1C Relationship between the transducer and the acquired volume. Enumerated Values: 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 FIXED 53 54 Required if the transducer position and/or orientation relative to the volume is not constant. May be present otherwise. 56 The transducer position and orientation relative to the volume is constant and specified by Volume to Transducer Mapping Matrix (0020,9309). POSITION_VAR The transducer position relative to the volume varies during acquisition and the position specified by Volume to Transducer Mapping Matrix (0020,9309) is a nominal value. The transducer orientation relative to the volume is constant and specified by Volume to Transducer Mapping Matrix (0020,9309). ORIENTATION_VAR The transducer orientation relative to the volume varies during acquisition and the orientation specified by Volume to Transducer Mapping Matrix (0020,9309) is a nominal value. The transducer position relative to the volume is constant and specified by Volume to Transducer Mapping Matrix (0020,9309). VARIABLE The transducer position and orientation relative to the volume varies during acquisition and the position and orientation specified by Volume to Transducer Mapping Matrix (0020,9309) are nominal. - Sep 2015 Votinng Packet - 32 CP-1475 - Add patient defined term for Ultrasound Acquisition Geometry Page 3 1 Attribute Name Tag Type Attribute Description 2 3 4 5 6 7 Volume to Transducer Mapping Matrix (0020,9309) 1 A 4x4 rigid transformation matrix that maps the Volume Frame of Reference homogeneous coordinate system (XV, YV, ZV) to the Transducer Frame of Reference homogeneous coordinate system (XX,YX, ZX). Matrix elements shall be listed in row-major order. See ??? for details. 8 9 Patient Frame of Reference Source (0020,930C) 1C Indicates how the supplied Image Position (Patient) (0020,0032) and Image Orientation (Patient) (0020,0037) values are obtained. 10 Enumerated Values: 11 12 13 14 15 16 17 18 TABLE 19 20 Required if either Image Position (Patient) (0020,0032) or Image Orientation (Patient) (0020,0037) is present. A positioning device, such as a gantry, was used to generate these values. ESTIMATED Estimated patient position / orientation (e.g., estimated by the user), or if reliable information is not available. REGISTRATION Acquisition has been spatially registered to a prior image set. 21 23 22 Table Frame of Reference UID 24 25 26 27 28 29 Volume to Table Mapping Matrix 30 31 (0020,9313) 1C Uniquely identifies this Table Frame of Reference. Required if Patient Frame of Reference Source (0020,930C) is TABLE. (0020,930A) 1C A 4x4 rigid transformation matrix that maps the Volume Frame of Reference homogeneous coordinate system (XV,YV, ZV) to the Table Frame of Reference homogeneous coordinate system (XT,YT, ZT). Matrix elements shall be listed in row-major order. See ??? for details. Required if Patient Frame of Reference Source (0020,930C) is TABLE. - Sep 2015 Votinng Packet -
© Copyright 2026 Paperzz