NMEA0183 Tester V141224

NMEA0183 TESTER
Operation Manual
SIM183
Document: NLT-SIM183-SSEN
Version:
V141225
Contents
Introduction................................................................................................. 1
FEATURES ....................................................................................................... 1
FUNCTIONS ..................................................................................................... 1
PACKING ......................................................................................................... 1
BUTTON DESCRIPTION .................................................................................... 2
Operation ..................................................................................................... 3
CHARGE .......................................................................................................... 3
LANGUAGE SELECTION ................................................................................... 3
MENU .............................................................................................................. 3
NMEA RECEIVER ............................................................................................. 4
NMEA SENDER ................................................................................................ 5
SEND BAUD SET ............................................................................................. 7
Common Sentence Format....................................................................... 8
Connection And Specification ................................................................. 9
CONNECTION TO ECHO SOUNDER .................................................................. 9
CONNECTION TO NMEA0183 PORTS OF OTHER DEVICES ............................. 9
SPECIFICATION ............................................................................................... 9
Introduction
NMEA0183 tester SIM183 is a handheld portable tester for testing transmit-received
NMEA0183 signals, with lithium battery for 9-hour continuous working. SIM183 can
receive and display NMEA0183 signal from an external device, and test baud rate and
peak value of the received signal. It also can send the selected NMEA0183 sentence
(optional 142 kind of NMEA0183 sentences) and the baud rate of the transmitted
signal can be set. In practical operation, NMEA0183 tester SIM183 can be applied for
the installation, debugging and trouble removal.
Features
 Built-in rechargeable battery, with portable and well-adapted
 Real-time read and display NMEA0183 sentences
 Test the peak value of received signals
 Auto test baud rate of received signals
 Send optional 142 kind of standard NMEA0183 sentences
 Customizable parameters in common NMEA0183 sentences for sounder and
speedlog
 Big screen green with black words on LCD display
Functions
NMEA0183Receiver:Read and test the received NMEA0183 signals. Real-time
display the received NMEA0183 sentence and test the peak value and baud rate.
NMEA0183 Sender:Send the standard NMEA0183 sentences (optional 142 kinds) to
an external device. According to INITIAL or COMMON DEVICE, select the relevant
sentences. In addition, users can set the information of DPT sentence used in echo
sounder, and VBW and VLW sentences used in speedlog.
Send Baud Set:Set baud rate of NMEA0183 signal sending to an external device.
Packing
Battery charger(110/220V)
12.6V/350mA ,charge build-in battery
1
1
Introduction
Button Description
LED indicators
Menu
navigation
buttons
Power on/off
Signal transceiver interface
Charging port
LED Indicators:
Yellow light will flash when transmitting NMEA0183 signals.
Red light will flash when receiving NMEA0183 signals.
Menu Navigation Buttons:
Flashing cursor key to change the location of flashing cursor
Increase/decrease key to increase/decrease parameter value
Start/pause key to start/pause simulation
ESC key to return to the previous menu
Enter key to enter into the selected menu
Signal transceiver interface: connector to connect with the external device.
Charging port:Battery charger(110/220V)12.6V/350mA
2
Operation
In the operation manual, take NLT 10’’ inch navigation sounder DS2008 as examples
to describe the operation of NMEA0183 tester SIM183. Practically, SIM183 can as
well transmit and receive the NMEA0183 signals with other devices.
Charge
Please charge when the battery is too low for extend the battery's life.
Language Selection
After the power-on, display the product's software version number and welcome
words first, and then enter the main menu.
For the change language, Press
before you enter the main menu, then the
language selection screen will appear, press
flashing cursor, and press
or
to change the location of the
to enter the selected language's main menu.
Press
Menu
SHOW MESSAGES
NMEA
SIGNAL
RECEIVER
TEST
INITIAL
Baud: bps(Range:2400,4800,9600,19200,38400)
Peak: V
Normal Range:2.0~15.0V
A B C D E F G H I J K L M N
O P Q R S T U V W X Y Z
GYRO
NMEA
SENDER
COMMON
DEVICE
ECHO
SOUNDER
Set the information in DPT sentences
SPEEDLOG
Set the information in VBW and VLW sentences
ANEMOMETER
GPS
3
ECDIS
RADAR
SEND BAUD SET
Optional:4800, 9600, 19200, 38400. Default 4800
Operation
NMEA RECEIVER
Properly connect the RX interface of the tester SIM183 to the NMEA0183output port
of an external device. If NMEA0183output port of an external device works normally,
the red light will flash; If the NMEA0183 output wires of an external device are
inversely connected, the red light will be normally on and users should connect the
wires inversely; If no matter normally or inversely connect the NMEA0183 output
wires of an external device, the red light will not work, which means the NMEA output
ports of an external device are abnormal. There is no NMEA0183 signal output or
output voltage is too low. Users can select SIGNAL TEST item of SIM183 to further
test the received NMEA0183 signal.
1. SHOW MESSAGES
Show the NMEA0183 output sentences from the external device.
In the main menu, press
and then press
to move the cursor and select ‘1. NMEA RECEIVER’,
to enter the secondary menu. Select ‘1. SHOW MESSAGES’ to
start show the received signal. And press
to pause receiving signals for a complete
sentence display.
①. Properly connect with
an
external
device's
NMEA signal port, and
then open the device.
Connect with only one
port at a time.
②.Select 1. SHOW
MESSAGES, and
press
to read
the sentences.
③.Select 2. SIGNAL
TEST, and press
to test the signal.
4
Operation
2. SIGNAL TEST
Test the baud rate and peak value of the received signal
In the main menu, press
and then press
to move the cursor and select ‘1. NMEA RECEIVER’,
to enter the secondary menu. Select ‘2. SIGNAL TEST’ to
measure and display the baud rate and peak value of the received signal. The range
of testing Baud rate is 2400, 4800, 9600, 19200 and 38400 bps and the range of peak
value is 0~15V. In additionally, the tester SIM183 provides the normal range of peak
value for user reference. And press
to return to the previous menu.
NMEA SENDER
Transmit the NMEA0183 signals to an external device (the yellow will be flashing).
Users can select the NMEA0183 sentences to send to an external device. The data in
the sentence can be set as 123456789, such as 12.3kn, 123.4m. The optional 142
kind of NMEA0183 sentences are bellow.
AAM
BPI
FSI
GOa
HCD
MDA
RMB
SCD
SYS
VBW
VWT
YWS
ACK
DBT
GBS
GXa
HDM
MHU
RMC
SDB
TLB
VDR
WCV
ZDA
ALM
DCN
GGA
GTD
HVD
MMB
ROT
SGD
TLL
VHW
WNC
ZDL
ALR
DPT
GLC
GXA
HVM
MTA
RPM
SGR
TTM
VLW
WPL
ZFO
In the main menu, press
then press
APB
DSC
GLL
HDG
IMA
MWH
RSA
SIU
TXT
VPW
WDC
ZTG
APA
DSE
GNS
HDT
LCD
MWS
RSD
SLC
TEC
VTG
WDR
Zaa
BEC
DSI
GRS
HMR
MLA
OSD
RTE
SNC
TEP
VCD
WFM
ZCD
BOD
DSR
GSA
HMS
MSK
OLN
Rnn
SNU
TGA
VPE
WNR
ZEV
BWC
DTM
GST
HSC
MSS
OLW
SFI
SPS
TIF
VTA
XDR
ZLZ
BWR
DBK
GSV
HTC
MTW
OMP
STN
SSF
TRF
VTI
XTE
ZZU
BWW
DBS
GDa
HTD
MWD
ONZ
SBK
STC
TRP
VWE
XTR
BER
DRU
GLa
HCC
MWV
RMA
SCY
STR
TRS
VWR
YWP
to move the cursor and select ‘2. NMEA SENDER’, and
to enter the secondary menu. There are two kind of NMEA selection
type.
5
Operation
1. INITIAL
Press
to enter INITIAL type and then press
select the initial of the sentence. Press
to move the cursor and
to enter the window of all sentences with
the selected initial.
2. COMMON DEVICE
Press
to enter COMMON DEVICE type and then press
to select the device
type simulated output by the tester SIM183. The device types are gyro, echo sounder,
speedlog, anemometer, GPS, ECDIS and radar. Press
to enter the window of all
sentences used for the selected device.
Then press
to move the cursor and select the sentence. Press
or
to
select ‘1’ or ‘0’, where ‘1’ means the sentence is selected to send and ‘0’ means the
sentence is not selected. After selecting one sentence, press
to send the sentence
and the yellow light will be flashing. The NMEA type will be also shown on the screen.
Press
to cancel the transmitting and return to the previous menu. And the yellow
light will be off and the selection will be saved.
② . Select 1.
INITIAL to choose
the sentence, and
press
to send
the sentence.
③ . Select 2. COMMON
DEVICE to choose the
sentence, and press
to
send the sentence.
①. Properly connect with
an
external
device's
NMEA signal port, and
then open the device.
Connect with only one
port at a time.
6
Operation
Especially, users can set the data parameters in DPT sentence for echo sounder, and
VBW and VLW sentence for speedlog as needed.
For example, the test is sending the VLW sentence to external speedlog repeater
IR861. Select ‘c. SPEED LOG’ and press
to enter the window of speedlog
sentences. Move the cursor to select VLW sentence. Press
sentence set. Press
to move the cursor and select the data location. Press
to set the data parameter and press
menu. Then, press
to enter the VLW
to save the settings and return to the previous
to start to send the set sentence. The speedlog repeater IR861
will receive this VLW sentence and display the setting voyage data. The settings of
the tester SIM183 are shown bellow. The total cumulative distance is 12345.67
nautical mile and the current voyage is 123.45 nautical mile. Users can change the
settings as needed.
SEND BAUD SET
Optional baud rate of the transmitting signal is 4800, 9600, 19200, 38400bps.
In the main menu, press
and then press
to move the cursor and select ‘3. SEND BAUD SET’,
to enter the secondary menu. Select the baud rate of the
transmitting signal press
to save and return to the main menu.
7
Common sentence format
DPT——Depth
$--DPT,x.x,x.x,x.x*hh<CR><LF>
Maximum range scale in use
Offset from transducer, in meters
Water depth relative to the transducer, in meters
VBW – Dual ground/water speed
$--VBW, x.x, x.x, A, x.x, x.x, A, x.x, A, x.x, A*hh<CR><LF>
Status: stern ground speed,
A = data valid, V = data invalid
Stern transverse ground speed, knots
Status: stern water speed,
A = data valid, V = data invalid
Stern transverse water speed, knots
Status, ground speed, A = data valid, V = data invalid
Transverse ground speed, knots
Longitudinal ground speed, knots
Status: water speed, A = data valid, V = data invalid
Transverse water speed, knots
Longitudinal water speed, knots
VLW——Distance travelled through the water
$--VLW,x.x,N,x.x,N*hh<CR><LF>
Distance since reset, nautical miles
Total cumulative distance, nautical miles
8
Connection and Specification
Connection to Echo Sounder
※ Sim183 is connected to NLT navigation echo sounder DS2008.
Invalid
Connection to NMEA0183 ports of other devices
NMEA0183
NMEA0183
signal output signal input
According to the identity on SIM183, one end of the wire connects to the RX or TX
interface of SIM183 and the other end connects to NMEA0183 signal output or input
interface of an external device (NMEA A to SIG - A, NMEA B to SIG – B).
Specification
Display
128×64 dot-matrix LCD
Dimension
235mm×135mm×55mm
Weight(battery included)
0.6kg
Recharge lithium battery
12.6VDC 1500mAh
Battery charger
12.6V / 350mA
Working Temperature
-15℃ ~ +55℃
Waterproof
IP23
9