NMEA0183 TESTER Operation Manual SIM183 Document: NLT-SIM183-SSEN Version: V141225 Contents Introduction................................................................................................. 1 FEATURES ....................................................................................................... 1 FUNCTIONS ..................................................................................................... 1 PACKING ......................................................................................................... 1 BUTTON DESCRIPTION .................................................................................... 2 Operation ..................................................................................................... 3 CHARGE .......................................................................................................... 3 LANGUAGE SELECTION ................................................................................... 3 MENU .............................................................................................................. 3 NMEA RECEIVER ............................................................................................. 4 NMEA SENDER ................................................................................................ 5 SEND BAUD SET ............................................................................................. 7 Common Sentence Format....................................................................... 8 Connection And Specification ................................................................. 9 CONNECTION TO ECHO SOUNDER .................................................................. 9 CONNECTION TO NMEA0183 PORTS OF OTHER DEVICES ............................. 9 SPECIFICATION ............................................................................................... 9 Introduction NMEA0183 tester SIM183 is a handheld portable tester for testing transmit-received NMEA0183 signals, with lithium battery for 9-hour continuous working. SIM183 can receive and display NMEA0183 signal from an external device, and test baud rate and peak value of the received signal. It also can send the selected NMEA0183 sentence (optional 142 kind of NMEA0183 sentences) and the baud rate of the transmitted signal can be set. In practical operation, NMEA0183 tester SIM183 can be applied for the installation, debugging and trouble removal. Features Built-in rechargeable battery, with portable and well-adapted Real-time read and display NMEA0183 sentences Test the peak value of received signals Auto test baud rate of received signals Send optional 142 kind of standard NMEA0183 sentences Customizable parameters in common NMEA0183 sentences for sounder and speedlog Big screen green with black words on LCD display Functions NMEA0183Receiver:Read and test the received NMEA0183 signals. Real-time display the received NMEA0183 sentence and test the peak value and baud rate. NMEA0183 Sender:Send the standard NMEA0183 sentences (optional 142 kinds) to an external device. According to INITIAL or COMMON DEVICE, select the relevant sentences. In addition, users can set the information of DPT sentence used in echo sounder, and VBW and VLW sentences used in speedlog. Send Baud Set:Set baud rate of NMEA0183 signal sending to an external device. Packing Battery charger(110/220V) 12.6V/350mA ,charge build-in battery 1 1 Introduction Button Description LED indicators Menu navigation buttons Power on/off Signal transceiver interface Charging port LED Indicators: Yellow light will flash when transmitting NMEA0183 signals. Red light will flash when receiving NMEA0183 signals. Menu Navigation Buttons: Flashing cursor key to change the location of flashing cursor Increase/decrease key to increase/decrease parameter value Start/pause key to start/pause simulation ESC key to return to the previous menu Enter key to enter into the selected menu Signal transceiver interface: connector to connect with the external device. Charging port:Battery charger(110/220V)12.6V/350mA 2 Operation In the operation manual, take NLT 10’’ inch navigation sounder DS2008 as examples to describe the operation of NMEA0183 tester SIM183. Practically, SIM183 can as well transmit and receive the NMEA0183 signals with other devices. Charge Please charge when the battery is too low for extend the battery's life. Language Selection After the power-on, display the product's software version number and welcome words first, and then enter the main menu. For the change language, Press before you enter the main menu, then the language selection screen will appear, press flashing cursor, and press or to change the location of the to enter the selected language's main menu. Press Menu SHOW MESSAGES NMEA SIGNAL RECEIVER TEST INITIAL Baud: bps(Range:2400,4800,9600,19200,38400) Peak: V Normal Range:2.0~15.0V A B C D E F G H I J K L M N O P Q R S T U V W X Y Z GYRO NMEA SENDER COMMON DEVICE ECHO SOUNDER Set the information in DPT sentences SPEEDLOG Set the information in VBW and VLW sentences ANEMOMETER GPS 3 ECDIS RADAR SEND BAUD SET Optional:4800, 9600, 19200, 38400. Default 4800 Operation NMEA RECEIVER Properly connect the RX interface of the tester SIM183 to the NMEA0183output port of an external device. If NMEA0183output port of an external device works normally, the red light will flash; If the NMEA0183 output wires of an external device are inversely connected, the red light will be normally on and users should connect the wires inversely; If no matter normally or inversely connect the NMEA0183 output wires of an external device, the red light will not work, which means the NMEA output ports of an external device are abnormal. There is no NMEA0183 signal output or output voltage is too low. Users can select SIGNAL TEST item of SIM183 to further test the received NMEA0183 signal. 1. SHOW MESSAGES Show the NMEA0183 output sentences from the external device. In the main menu, press and then press to move the cursor and select ‘1. NMEA RECEIVER’, to enter the secondary menu. Select ‘1. SHOW MESSAGES’ to start show the received signal. And press to pause receiving signals for a complete sentence display. ①. Properly connect with an external device's NMEA signal port, and then open the device. Connect with only one port at a time. ②.Select 1. SHOW MESSAGES, and press to read the sentences. ③.Select 2. SIGNAL TEST, and press to test the signal. 4 Operation 2. SIGNAL TEST Test the baud rate and peak value of the received signal In the main menu, press and then press to move the cursor and select ‘1. NMEA RECEIVER’, to enter the secondary menu. Select ‘2. SIGNAL TEST’ to measure and display the baud rate and peak value of the received signal. The range of testing Baud rate is 2400, 4800, 9600, 19200 and 38400 bps and the range of peak value is 0~15V. In additionally, the tester SIM183 provides the normal range of peak value for user reference. And press to return to the previous menu. NMEA SENDER Transmit the NMEA0183 signals to an external device (the yellow will be flashing). Users can select the NMEA0183 sentences to send to an external device. The data in the sentence can be set as 123456789, such as 12.3kn, 123.4m. The optional 142 kind of NMEA0183 sentences are bellow. AAM BPI FSI GOa HCD MDA RMB SCD SYS VBW VWT YWS ACK DBT GBS GXa HDM MHU RMC SDB TLB VDR WCV ZDA ALM DCN GGA GTD HVD MMB ROT SGD TLL VHW WNC ZDL ALR DPT GLC GXA HVM MTA RPM SGR TTM VLW WPL ZFO In the main menu, press then press APB DSC GLL HDG IMA MWH RSA SIU TXT VPW WDC ZTG APA DSE GNS HDT LCD MWS RSD SLC TEC VTG WDR Zaa BEC DSI GRS HMR MLA OSD RTE SNC TEP VCD WFM ZCD BOD DSR GSA HMS MSK OLN Rnn SNU TGA VPE WNR ZEV BWC DTM GST HSC MSS OLW SFI SPS TIF VTA XDR ZLZ BWR DBK GSV HTC MTW OMP STN SSF TRF VTI XTE ZZU BWW DBS GDa HTD MWD ONZ SBK STC TRP VWE XTR BER DRU GLa HCC MWV RMA SCY STR TRS VWR YWP to move the cursor and select ‘2. NMEA SENDER’, and to enter the secondary menu. There are two kind of NMEA selection type. 5 Operation 1. INITIAL Press to enter INITIAL type and then press select the initial of the sentence. Press to move the cursor and to enter the window of all sentences with the selected initial. 2. COMMON DEVICE Press to enter COMMON DEVICE type and then press to select the device type simulated output by the tester SIM183. The device types are gyro, echo sounder, speedlog, anemometer, GPS, ECDIS and radar. Press to enter the window of all sentences used for the selected device. Then press to move the cursor and select the sentence. Press or to select ‘1’ or ‘0’, where ‘1’ means the sentence is selected to send and ‘0’ means the sentence is not selected. After selecting one sentence, press to send the sentence and the yellow light will be flashing. The NMEA type will be also shown on the screen. Press to cancel the transmitting and return to the previous menu. And the yellow light will be off and the selection will be saved. ② . Select 1. INITIAL to choose the sentence, and press to send the sentence. ③ . Select 2. COMMON DEVICE to choose the sentence, and press to send the sentence. ①. Properly connect with an external device's NMEA signal port, and then open the device. Connect with only one port at a time. 6 Operation Especially, users can set the data parameters in DPT sentence for echo sounder, and VBW and VLW sentence for speedlog as needed. For example, the test is sending the VLW sentence to external speedlog repeater IR861. Select ‘c. SPEED LOG’ and press to enter the window of speedlog sentences. Move the cursor to select VLW sentence. Press sentence set. Press to move the cursor and select the data location. Press to set the data parameter and press menu. Then, press to enter the VLW to save the settings and return to the previous to start to send the set sentence. The speedlog repeater IR861 will receive this VLW sentence and display the setting voyage data. The settings of the tester SIM183 are shown bellow. The total cumulative distance is 12345.67 nautical mile and the current voyage is 123.45 nautical mile. Users can change the settings as needed. SEND BAUD SET Optional baud rate of the transmitting signal is 4800, 9600, 19200, 38400bps. In the main menu, press and then press to move the cursor and select ‘3. SEND BAUD SET’, to enter the secondary menu. Select the baud rate of the transmitting signal press to save and return to the main menu. 7 Common sentence format DPT——Depth $--DPT,x.x,x.x,x.x*hh<CR><LF> Maximum range scale in use Offset from transducer, in meters Water depth relative to the transducer, in meters VBW – Dual ground/water speed $--VBW, x.x, x.x, A, x.x, x.x, A, x.x, A, x.x, A*hh<CR><LF> Status: stern ground speed, A = data valid, V = data invalid Stern transverse ground speed, knots Status: stern water speed, A = data valid, V = data invalid Stern transverse water speed, knots Status, ground speed, A = data valid, V = data invalid Transverse ground speed, knots Longitudinal ground speed, knots Status: water speed, A = data valid, V = data invalid Transverse water speed, knots Longitudinal water speed, knots VLW——Distance travelled through the water $--VLW,x.x,N,x.x,N*hh<CR><LF> Distance since reset, nautical miles Total cumulative distance, nautical miles 8 Connection and Specification Connection to Echo Sounder ※ Sim183 is connected to NLT navigation echo sounder DS2008. Invalid Connection to NMEA0183 ports of other devices NMEA0183 NMEA0183 signal output signal input According to the identity on SIM183, one end of the wire connects to the RX or TX interface of SIM183 and the other end connects to NMEA0183 signal output or input interface of an external device (NMEA A to SIG - A, NMEA B to SIG – B). Specification Display 128×64 dot-matrix LCD Dimension 235mm×135mm×55mm Weight(battery included) 0.6kg Recharge lithium battery 12.6VDC 1500mAh Battery charger 12.6V / 350mA Working Temperature -15℃ ~ +55℃ Waterproof IP23 9
© Copyright 2025 Paperzz