CG 4D (12V180Ah)

CG 4D (12V180Ah)
1.Features:
*
*
*
*
Gelled-electrolyte
Reliable
Maintenance-free power for renewable engery
Deep cycle
2. Applications:
*
Water pumping
*
Aids to navigation
*
Wind generation
*
Signalling and lighting
*
Solar, Wind Power-Aviation & Marine
*
UPS & communications
3. Specifications:
Nominal Voltage
V
12
Capacity ( 20 hour rate)
Ah
180
Height Max.
mm
219
Height
mm
214
Dimensions
Length
mm
530
Width
mm
209
Weight
Approx. Kg
53
Internal Resistance
6
mΩ
Charge
Float
V / Cell
13.6 ~ 13.8
Voltage
Equalization
V/ Cell
14.2 ~ 14.4
(At 25℃)
and Cycle
4. Discharge Current VS. Discharge Voltage:
Final
1.75V/cell
1.70V/cell
Discharge
Voltage
Discharge
0.2C < (A) < 1.0C
(A) ≤ 0.2C
Current (A)
1.60V/cell
(A) ≥ 1.0C
5. Charging Method (At 25℃):
Constant Voltage
-0.2C x 2h + 2.4 ~ 2.45V/cell x 24h, Max.
Constant Current
-0.2C x 2h + 0.1CA x 12h
Fast
-0.2C x 2h + 0.3CA x 4.0h
6. Constant Current Discharge Table (At 25℃):
Discharge
Time
5 min
10 min
15 min
30 min
1 hr
2 hr
3 hr
4 hr
5 hr
8 hr
10 hr
20 hr
Discharge End Voltage (V)
AMPS
1.67
552.51
387.06
289.91
182.73
104.53
59.5
42.01
34.74
29.22
20.12
16.99
8.91
1.70
520.63
373.4
285.36
181.12
103.57
59.05
41.69
34.58
29.04
19.95
16.82
8.74
WATT
1.75
467.51
344.56
271.7
176.59
102.6
58.6
41.52
34.25
28.7
19.79
16.66
8.58
1.80
421.97
314.2
250.45
168.84
100.17
57.55
40.39
33.45
28.18
19.46
16.49
8.41
1.67
5296.2
3776.2
2850.5
2070.7
1195.3
686.98
485.67
402.3
338.15
234.39
190.87
100.88
1.70
4999.5
3650.4
2811.8
2046.4
1186.6
680.67
482.77
400.37
337.11
232.41
189.89
98.89
1.75
4502
3373.1
2681.2
1999.9
1174.9
674.36
479.86
397.46
334
230.43
187.91
98.9
1.80
4049.6
3062.6
2463.5
1908.8
1145.8
664.44
468.22
386.79
328.81
225.49
185.93
97.91
SZG0010V1
CG 4D (12V180Ah)
6. Life Characteristics of Cyclic Use
7. Charge Characteristic Curve for standby use
8. Storage Characteristic
Supplementary charge required (Carry
out supplementarty charge before use if
100% capacity is requires)
Supplementary charge required before
use. This supplementary charge will help
recovering the capacity and should be
made as early as possible.
Supplementary charge may often fail to
recover the capacity. The battery should
never be left standing till this state is
reached.
Supplementary charge and storage
guidelines.
9. Discharge Characteristic Curve
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty
with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice.
Contact us at www.citibat.com for the latest information.
SZG0010V1