CG 4D (12V180Ah) 1.Features: * * * * Gelled-electrolyte Reliable Maintenance-free power for renewable engery Deep cycle 2. Applications: * Water pumping * Aids to navigation * Wind generation * Signalling and lighting * Solar, Wind Power-Aviation & Marine * UPS & communications 3. Specifications: Nominal Voltage V 12 Capacity ( 20 hour rate) Ah 180 Height Max. mm 219 Height mm 214 Dimensions Length mm 530 Width mm 209 Weight Approx. Kg 53 Internal Resistance 6 mΩ Charge Float V / Cell 13.6 ~ 13.8 Voltage Equalization V/ Cell 14.2 ~ 14.4 (At 25℃) and Cycle 4. Discharge Current VS. Discharge Voltage: Final 1.75V/cell 1.70V/cell Discharge Voltage Discharge 0.2C < (A) < 1.0C (A) ≤ 0.2C Current (A) 1.60V/cell (A) ≥ 1.0C 5. Charging Method (At 25℃): Constant Voltage -0.2C x 2h + 2.4 ~ 2.45V/cell x 24h, Max. Constant Current -0.2C x 2h + 0.1CA x 12h Fast -0.2C x 2h + 0.3CA x 4.0h 6. Constant Current Discharge Table (At 25℃): Discharge Time 5 min 10 min 15 min 30 min 1 hr 2 hr 3 hr 4 hr 5 hr 8 hr 10 hr 20 hr Discharge End Voltage (V) AMPS 1.67 552.51 387.06 289.91 182.73 104.53 59.5 42.01 34.74 29.22 20.12 16.99 8.91 1.70 520.63 373.4 285.36 181.12 103.57 59.05 41.69 34.58 29.04 19.95 16.82 8.74 WATT 1.75 467.51 344.56 271.7 176.59 102.6 58.6 41.52 34.25 28.7 19.79 16.66 8.58 1.80 421.97 314.2 250.45 168.84 100.17 57.55 40.39 33.45 28.18 19.46 16.49 8.41 1.67 5296.2 3776.2 2850.5 2070.7 1195.3 686.98 485.67 402.3 338.15 234.39 190.87 100.88 1.70 4999.5 3650.4 2811.8 2046.4 1186.6 680.67 482.77 400.37 337.11 232.41 189.89 98.89 1.75 4502 3373.1 2681.2 1999.9 1174.9 674.36 479.86 397.46 334 230.43 187.91 98.9 1.80 4049.6 3062.6 2463.5 1908.8 1145.8 664.44 468.22 386.79 328.81 225.49 185.93 97.91 SZG0010V1 CG 4D (12V180Ah) 6. Life Characteristics of Cyclic Use 7. Charge Characteristic Curve for standby use 8. Storage Characteristic Supplementary charge required (Carry out supplementarty charge before use if 100% capacity is requires) Supplementary charge required before use. This supplementary charge will help recovering the capacity and should be made as early as possible. Supplementary charge may often fail to recover the capacity. The battery should never be left standing till this state is reached. Supplementary charge and storage guidelines. 9. Discharge Characteristic Curve This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact us at www.citibat.com for the latest information. SZG0010V1
© Copyright 2026 Paperzz