Internal walls and partitions New-build and conversion For new-build and for new walls in material change of use (conversion), Building Regulations Approved Document E states that the following internal walls and partitions must meet the Rw 40 dB requirement: ● An internal wall between bedrooms ● An internal wall between a bathroom / WC and a habitable room ● An internal wall between bedrooms and any other room Where internal walls include a door, they are exempt from this requirement. Example systems GypWall CLASSIC Stud: Gypframe 70 S 50 ‘C’ Studs Centres: 600mm Maximum height: 3600mm Wall lining: 12.5mm Gyproc SoundBloc (each side) Rw 40 dB 30 minutes fire resistance Timber stud Stud: Non-loadbearing 63mm x 38mm timber Centres: 600mm Maximum height: 3600mm Wall lining: 15mm Gyproc SoundBloc (each side) Additional info: Timber noggings may be required for structural support Rw 40 dB 30 minutes fire resistance The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Stockist-03-02 1 DriLyner BASIC Wall construction: 100mm medium density concrete blocks (minimum 120kg / m2) Plasterboard fixing method: DriLyner BASIC using Gyproc Dri-Wall Adhesive Wall lining: 15mm Gyproc SoundBloc (each side) Rw 40 dB 30 minutes fire resistance (dependent on base wall performance) For partitions that do not fall into the above criteria, for example a wall that includes a door, there is no requirement to improve the acoustic insulation, therefore 12.5mm Gyproc WallBoard can be used to line either side of the partition. To upgrade the acoustic insulation of existing masonry partitions, Gyproc Soundcoat Plus can be used to seal air paths before using DriLyner BASIC to ‘dot and dab’ Gyproc SoundBloc to the walls. The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 2 Stockist-03-02 Internal floors New-build and conversion For new-build and new floors in material change of use (conversion), Building Regulations Approved Document E state that internal floors are required to meet Rw 40 dB. Fixing plasterboard directly into timber joists can result in nail or screw popping. Using Gypframe RB2 SureFix Bars in the construction of the ceiling can eliminate this problem, and help maintain the performance and the aesthetics of the ceiling. Example systems Solid timber joist (600mm centres) Flooring: 22mm tongue and groove chipboard flooring Joists: 195mm x 38mm solid joists at 600mm centres Ceiling lining: 12.5mm Gyproc SoundBloc Rw 42 dB 30 minutes fire resistance Solid timber joist (600mm centres) Flooring: 22mm tongue and groove chipboard flooring Joists: 195mm x 38mm solid joists at 600mm centres Ceiling lining: 15mm Gyproc WallBoard Rw 40 dB 30 minutes fire resistance The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Stockist-03-02 3 Solid timber joist (450mm centres) Flooring: 22mm tongue and groove chipboard flooring Joists: 195mm x 38mm solid joists at 450mm centres Ceiling fixing: Gypframe RB2 SureFix Bars Ceiling lining: 12.5mm Gyproc WallBoard Rw 41 dB 30 minutes fire resistance Intregral garage conversion When building an integral garage, the floor acts as a bridge between a heated and unheated space. Building Regulations require the floor and ceiling to meet 30 minutes fire resistance whilst also providing thermal insulation. The following system provides example guidance. Floor for integral garage Flooring: 22mm tongue and groove chipboard flooring Joists: 195mm x 38mm solid joists at 600mm centres Insulation: 200mm Isover Space Saver Roll Ceiling lining: 15mm Gyproc FireLine 30 minutes fire resistance U value 0.22 W / m2K The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 4 Stockist-03-02 Separating walls New-build When building new separating / party walls between dwellings Building Regulations Approved Document E states they are required to meet the 45 dB DnTw + Ctr requirement. Example systems Lightweight aggregate blockwork with wet plaster Wall construction: Lightweight aggregate cavity block wall (minimum 100mm blocks with a density between 1350 - 1600 kg / m3) Cavity: Minimum 75mm cavity between blockwork Wall lining: 13mm Thistle plaster - undercoat and finish coat (each side) Robust Detail E-WM-2 meets the 45 dB DnTw + Ctr requirement 60 minutes fire resistance (dependent on base wall performance) Lightweight aggregate blockwork with render and plasterboard Wall construction: Lightweight aggregate cavity block wall (minimum 100mm blocks with a density between 1350 - 1600 kg / m3) Wall preparation: 6mm Gyproc Soundcoat Plus (each side) Plasterboard fixing method: DriLyner BASIC using Gyproc Dri-Wall Adhesive Wall lining: 12.5mm Gyproc WallBoard (each side) Robust Detail E-WM-4 meets the 45 dB DnTw + Ctr requirement 30 minutes fire resistance (dependent on base wall performance) For separating wall and floor constructions to be fully effective, care must be taken to correctly detail the junctions between the separating wall or floor and associated elements such as external walls, other separating elements and penetrations or door openings, etc. The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Stockist-03-02 5 Conversion For material change of use / conversion of separating walls, Building Regulations state that they are required to meet the 43 dB DnTw + Ctr requirement. Often upgrading existing separating walls can only be achieved from one side of the wall, therefore to reduce as much air leakage as possible, apply a 6-8mm coat of Gyproc Soundcoat Plus to the masonry wall prior to installation of a drylining system to increase its acoustic potential. Example systems Masonry wall with DriLyner SI Wall construction: Masonry wall such as brickwork (minimum 200kg / m2) Plasterboard fixing method: DriLyner SI using Gyproc Dri-Wall Adhesive with Gyproc Nailable Plugs Wall lining: 52mm Gyproc TriLine Additional info: Wall must be plastered on the other side 43 dB DnTw + Ctr 60 minutes fire resistance (dependent on base wall performance) This system is more suited to reducing mid-frequency sounds, such as speech. Masonry wall with GypLyner UNIVERSAL Wall construction: Masonry wall (such as brickwork) Cavity: Minimum 35mm cavity (created by GypLyner UNIVERSAL system) with 25mm Isover APR 1200 insulation Wall lining: 2 x 12.5mm Gyproc SoundBloc Additional info: Wall must be plastered on the other side 43 dB DnTw + Ctr 60 minutes fire resistance (dependent on base wall performance) This system will provide better acoustic insulation against hard to tackle low-frequency sounds, such as home cinema systems. For separating wall and floor constructions to be fully effective, care must be taken to correctly detail the junctions between the separating wall or floor and associated elements such as external walls, other separating elements and penetrations or door openings, etc. The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 6 Stockist-03-02 Separating floors New-build When building new separating floors between dwellings Building Regulations Approved Document E state they are required to meet the 45 dB DnTw + Ctr requirement. Example systems Solid timber joist with timber battens Flooring: 18mm tongue and groove chipboard flooring Under flooring layer: 19mm Gyproc Plank Battens: Resilient composite timber battens at 400mm centres Floor insulation: 65mm Isover APR 1200 Sub-deck: 15mm OSB Joists: Minimum 220mm solid timber joists at 400mm centres Ceiling fixing: Gypframe RB1 Resilient Bar at 400mm centres Joist cavity fill: 100mm Isover APR 1200 Ceiling lining: 19mm Gyproc Plank and 12.5mm Gyproc WallBoard Robust Detail E-FT-2 meets the 45 dB DnTw + Ctr requirement 60 minutes fire resistance For separating wall and floor constructions to be fully effective, care must be taken to correctly detail the junctions between the separating wall or floor and associated elements such as external walls, other separating elements and penetrations or door openings, etc. The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Stockist-03-02 7 Solid timber joist with Gypframe Steel Battens Flooring: 22mm tongue and groove chipboard flooring Under flooring layer: 19mm Gyproc Plank Battens: 70mm Gypframe 70 SB 65 Steel Battens at 400mm centres Floor insulation: 50mm Isover APR 1200 Sub-deck: 15mm OSB Joists: Minimum 240mm solid timber joists at 400mm centres Ceiling fixing: Gypframe RB1 Resilient Bar at 450mm centres Joist cavity fill: 100mm Isover APR 1200 Ceiling lining: 2 x 15mm Gyproc SoundBloc Additional info: Where a cavity is required between the ceiling and the joists, Gypframe Resilient Bars can be replaced with the CasoLine MF ceiling, to give a 287mm cavity 45 dB DnTw + Ctr 60 minutes fire resistance Engineered timber ‘I’ joist with timber battens Flooring: 22mm tongue and groove chipboard flooring Under flooring layer: 19mm Gyproc Plank Battens: Resilient composite timber battens at 400mm centres Floor insulation: 50mm Isover APR 1200 Sub-deck: 15mm OSB Joists: Minimum 240mm engineered timber ‘I’ joists at 400mm centres Ceiling fixing: Gypframe RB1 Resilient Bar at 400mm centres Joist cavity fill: 100mm Isover APR 1200 Ceiling lining: 19mm Gyproc Plank and 12.5mm Gyproc SoundBloc Robust Detail E-FT-1 meets the 45 dB DnTw + Ctr requirement 60 minutes fire resistance For separating wall and floor constructions to be fully effective, care must be taken to correctly detail the junctions between the separating wall or floor and associated elements such as external walls, other separating elements and penetrations or door openings, etc. The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 8 Stockist-03-02 Conversion For material change of use / conversion of separating walls, Building Regulations Approved Document E state they are required to meet the 43 dB DnTw + Ctr requirement. Example systems Solid timber joist with GypFloor SILENT and CasoLine MF ceiling Flooring: 21mm tongue and groove chipboard flooring Under flooring layer: 19mm Gyproc Plank Joist channels: Gypframe SIF Floor Channels Joists: Solid timber joists Cavity fill: 100mm Isover APR 1200 Ceiling system: CasoLine MF suspended ceiling to give a 277mm cavity Ceiling lining: 2 x 15mm Gyproc SoundBloc Floor depth: From top of joist approximately 30mm Overall floor / ceiling depth: Approximately 340mm 43 dB DnTw + Ctr 60 minutes fire resistance For separating wall and floor constructions to be fully effective, care must be taken to correctly detail the junctions between the separating wall or floor and associated elements such as external walls, other separating elements and penetrations or door openings, etc. The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Stockist-03-02 9 Solid timber joist with GypFloor SILENT Flooring: 21mm tongue and groove chipboard flooring Joist channels: Gypframe SIF Floor Channels Joists: Solid timber joists at 450mm or 600mm centres Cavity fill: 100mm Isover APR 1200 Ceiling system: Gypframe RB1 Resilient Bar at 450mm centres Ceiling lining: Inner layer 19mm Gyproc Plank Outer layer 12.5mm Gyproc SoundBloc Floor depth: Approximately 30mm Ceiling depth: Approximately 50mm Additional info: Where a cavity is required between the ceiling and the joists, Gypframe Resilient Bars can be replaced with the CasoLine MF ceiling, to give a 287mm cavity 43 dB DnTw + Ctr 60 minutes fire resistance Solid timber joist with GypFloor SILENT and retained ceiling Flooring: 21mm tongue and groove chipboard flooring Under flooring layer: 19mm Gyproc Plank Joist channels: Gypframe SIF Floor Channels Joists: Solid timber joists (minimum 50mm width) Fire protection: Cavity bridged between joists by 12.5mm Glasroc F MULTIBOARD, resting on 12.5mm Glasroc F MULTIBOARD strips, screw fixed to each joist (fixed flush) Cavity fill: 100mm Isover APR 1200 Ceiling lining: Original lath and plaster ceiling Floor depth: Approximately 30mm Ceiling depth: None Test and declare1 60 minutes fire resistance 1 Where the original ceiling needs to be retained, for example an ornate lath and plaster ceiling in an historic building, it may not be possible to achieve the regulatory standards. It may therefore be permitted to test on site and declare the performance achieved subject to Building Control acceptance. For separating wall and floor constructions to be fully effective, care must be taken to correctly detail the junctions between the separating wall or floor and associated elements such as external walls, other separating elements and penetrations or door openings, etc. The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 10 Stockist-03-02 External walls New-build Building Regulations Approved Document L1A stipulates that compliance is based on the carbon performance of the whole dwelling and a whole building measure is given through the use of a SAP calculation. There are many factors that influence the SAP calculation and the U-value of the external envelope (external walls) is only one part of this. Therefore the following example systems detail different U-values that can be achieved by using alternate Gyproc ThermaLine laminates; this should help give the flexibility required when designing a new property. In Scotland, Building Regulations Section 6 stipulates minimum performances and these can vary depending on the type of heating system. Example systems Full-fill cavity wall with medium density blocks External leaf: 103mm brick skin Cavity: 75mm cavity full-filled with Isover Hi-Cav Internal leaf: 100mm medium dense block (0.61 W/m2K) Plasterboard fixing method: Wall lining: DriLyner BASIC with Gyproc Dri-Wall Adhesive or DriLyner TL using Gyproc Dri-Wall Adhesive and Gyproc Nailable Plugs Gyproc WallBoard or Gyproc ThermaLine laminate (see below) U-value Gyproc ThermaLine laminate Wall thickness (mm) 0.17 70mm Gyproc ThermaLine SUPER 358 0.18 60mm Gyproc ThermaLine SUPER 348 0.20 50mm Gyproc ThermaLine SUPER 338 0.25 40mm Gyproc ThermaLine PLUS 328 0.26 35mm Gyproc ThermaLine PLUS 323 0.34 12.5mm Gyproc WallBoard 301 The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Stockist-03-02 11 Full-fill cavity wall with aircrete blocks External leaf: 103mm brick skin Cavity: 75mm cavity full-filled with Isover Hi-Cav insulation Internal leaf: 100mm aircrete block (0.11 W/m2K) Plasterboard fixing method: DriLyner BASIC with Gyproc Dri-Wall Adhesive or DriLyner TL using Gyproc Dri-Wall Adhesive and Gyproc Nailable Plugs Wall lining: Gyproc WallBoard or Gyproc ThermaLine laminate (see below) U-value Gyproc ThermaLine laminate Wall thickness (mm) 0.18 50mm Gyproc ThermaLine SUPER 338 0.22 40mm Gyproc ThermaLine SUPER 328 0.23 35mm Gyproc ThermaLine PLUS 323 0.24 27mm Gyproc ThermaLine PLUS 315 0.26 22mm Gyproc ThermaLine BASIC1 310 0.28 12.5mm Gyproc WallBoard 301 1 Two coats of Gyproc Drywall Sealer are required to provide a vapour control layer. Conversion Building Regulations Approved Document L1B includes extensions, creating new dwellings through a change of use, or alterations to existing dwellings. The thermal element, i.e. the wall, roof or floor that separates a heated space from an unheated space, must achieve set U-values and these vary depending on whether the thermal element is in an extension or renovation of an existing element. The following table highlights the U-value required, and these values can then be selected from the following example systems. L1B New element (e.g. extensions) Renovations Wall Cavity wall 0.30 0.30 0.35 (0.70)1 0.55 (0.70)1 1 If the current element is worse than the U-value quoted in brackets, then they should be upgraded to the adjacent U-value. In Scotland, Building Regulations Section 6 stipulates minimum performances. For walls, typically 0.27 W/m2K is required. The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 12 Stockist-03-02 Example systems Clear cavity wall with medium density blocks External leaf: 103mm brick skin Cavity: Minimum 50mm clear cavity Internal leaf: 100mm medium dense block (0.61 W/m2K) Plasterboard fixing method: DriLyner TL using Gyproc Dri-Wall Adhesive and Gyproc Nailable Plugs Wall lining: Gyproc ThermaLine laminate (see below) U-value Gyproc ThermaLine laminate Wall thickness (mm) 0.21 90mm Gyproc ThermaLine SUPER 353 0.26 70mm Gyproc ThermaLine SUPER 333 0.30 60mm Gyproc ThermaLine SUPER 323 Clear cavity wall with aircrete blocks External leaf: 103mm brick skin Cavity: Minimum 50mm clear cavity Internal leaf: 100mm aircrete block (0.11 W/m2K) Plasterboard fixing method: DriLyner TL using Gyproc Dri-Wall Adhesive and Gyproc Nailable Plugs Wall lining: Gyproc ThermaLine laminate (see below) U-value Gyproc ThermaLine laminate Wall thickness (mm) 0.19 90mm Gyproc ThermaLine SUPER 353 0.20 80mm Gyproc ThermaLine SUPER 343 0.23 70mm Gyproc ThermaLine SUPER 333 0.26 60mm Gyproc ThermaLine SUPER 323 0.31 50mm Gyproc ThermaLine SUPER 313 0.54 30mm Gyproc ThermaLine BASIC1 293 1 Two coats of Gyproc Drywall Sealer are required to provide a vapour control layer. The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Stockist-03-02 13 Brick and brick clear cavity wall External leaf: 103mm brick skin Cavity: Minimum 50mm clear cavity Internal leaf: 103mm brick Plasterboard fixing method: DriLyner TL using Gyproc Dri-Wall Adhesive and Gyproc Nailable Plugs Wall lining: Gyproc ThermaLine laminate (see below) U-value Gyproc ThermaLine laminate Wall thickness (mm) 0.21 90mm Gyproc ThermaLine SUPER 356 0.23 80mm Gyproc ThermaLine SUPER 346 0.26 70mm Gyproc ThermaLine SUPER 336 0.30 60mm Gyproc ThermaLine SUPER 326 0.37 50mm Gyproc ThermaLine SUPER 316 0.55 40mm Gyproc ThermaLine PLUS 306 Solid brick wall Wall construction: 215mm solid brick wall Plasterboard fixing method: GypLyner UNIVERSAL (or DriLyner RF using Gyproc Sealant, where stated) Wall lining: Gyproc ThermaLine laminate (see below) U-value Gyproc ThermaLine laminate Wall thickness (mm) 0.24 70mm Gyproc ThermaLine SUPER and 50mm Isover APR 1200 335 0.25 80mm Gyproc ThermaLine SUPER (no insulation and 25mm cavity) 320 0.27 70mm Gyproc ThermaLine SUPER and 25mm Isover APR 1200 310 0.33 60mm Gyproc ThermaLine SUPER using DriLyner RF (brickwork plastered internally) 291 (minimum) The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 14 Stockist-03-02 Solid stone wall External leaf: 300mm solid stone wall Plasterboard fixing method: GypLyner UNIVERSAL Wall lining: Gyproc ThermaLine laminate (see below) U-value Gyproc ThermaLine laminate Wall thickness (mm) 0.23 90mm Gyproc ThermaLine SUPER 415 0.25 70mm Gyproc ThermaLine SUPER and 50mm Isover APR 1200 420 0.26 80mm Gyproc ThermaLine SUPER 405 0.28 60mm Gyproc ThermaLine SUPER and 50mm Isover APR 1200 410 0.28 70mm Gyproc ThermaLine SUPER and 25mm Isover APR 1200 395 0.32 60mm Gyproc ThermaLine SUPER and 25mm Isover APR 1200 385 Render and block wall Wall construction: 16mm external render, 190mm medium density block (0.61 W/m2K) Plasterboard fixing method: GypLyner UNIVERSAL (or DriLyner RF using Gyproc Sealant, where stated) Wall lining: Gyproc ThermaLine laminate (see below) U-value Gyproc ThermaLine laminate Wall thickness (mm) 0.24 80mm Gyproc ThermaLine SUPER using DriLyner RF (blockwork plastered internally) 302 0.24 70mm Gyproc ThermaLine SUPER and 50mm Isover APR 1200 326 0.26 70mm Gyproc ThermaLine SUPER and 25mm Isover APR 1200 307 0.32 60mm Gyproc ThermaLine SUPER using DriLyner RF (blockwork plastered internally) 282 Window reveals Window reveals can often be a weak point in the thermal insulation as space is restricted for fitting Gyproc ThermaLine laminates. 27mm Gyproc ThermaLine PLUS is a thin laminate that can be used around window reveals and where space is tight. Ensuring all surfaces of external walls are covered with some insulation will improve the overall insulation of the space. The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Stockist-03-02 15 Basements and cellars Rooms beneath the ground can be difficult to treat as moisture can travel through the ground. Basements and cellars can have a tanking treatment to reduce this occurrence, however this can cause condensation to form on the inside of the room. The GypLyner IWL (Independent Wall Lining) system builds away from existing walls, fixing to floors, ceilings and adjacent walls to support the framework to reduce the contact with any tanking. Gyproc ThermaLine PLUS has a high level of thermal insulation as well as a vapour control barrier to reduce condensation forming behind the lining. Seek advice Some tanking methods will be downgraded if there is any penetration in the tanking seal. BS5250:2002 contains some limited guidance. However, we would advise you to seek the guidance of a specialist in the field of Hygrothermal performance and properties for structures below ground to determine whether there is any risk of interstitial condensation within the construction. The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 16 Stockist-03-02 Room-in-the-roof and loft spaces New-build Building Regulations Approved Document L stipulates that the external fabric (e.g. gable walls) meet minimum requirements to comply with thermal performances. Example constructions for wall and roof linings are shown below. In Scotland, Building Regulations Section 6 stipulates minimum performances which can vary depending on the type of heating system, typically 0.27 W/m2K for walls, 0.20 W/m2K for pitched roofs with insulation between the rafters (room-in-the-roof) and 0.16 W/m2K for pitched roofs with insulation between ceiling joists (loft spaces). Example systems Wall linings Studs: Timber studs at 600mm centres Insulation: Installed between the studs (see below) Timber fraction: 15% Wall lining: Gyproc ThermaLine laminate or plasterboard (see below) U-value Insulation Gyproc ThermaLine laminate / plasterboard 0.24 140mm Isover Frame Batt 35 40mm Gyproc ThermaLine PLUS 0.25 140mm Isover Frame Batt 34 40mm Gyproc ThermaLine BASIC1 0.30 100mm Isover Frame Batt 35 35mm Gyproc ThermaLine PLUS 0.30 140mm Isover Frame Batt 34 12.5mm Gyproc WallBoard DUPLEX 1 Two coats of Gyproc Drywall Sealer are required to provide a vapour control layer. Roof lining Roof construction: Tiled or slated roof on tiling battens on breather membrane. Softwood rafters at 600mm centres Insulation: Installed between the rafters (see below) Timber fraction: 8.3% Roof lining: Gyproc ThermaLine laminate (see below) U-value Insulation Gyproc ThermaLine laminate 0.13 200mm (4 x) 50mm Isover Frame Batt 32 70mm Gyproc ThermaLine SUPER 0.13 200mm (2 x) 100mm Isover Frame Batt 35 70mm Gyproc ThermaLine SUPER 0.16 140mm Isover Frame Batt 34 70mm Gyproc ThermaLine SUPER 0.19 100mm Isover Frame Batt 35 70mm Gyproc ThermaLine SUPER The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Stockist-03-02 17 Conversion Whether insulating a loft space to meet Building Regulations Approved Document L or transforming it to a liveable room-in-the-roof, the following U-value requirements should be met. L1B Wall Pitched roof with insulation between the rafters (room-in-the-roof) Pitched roof with insulation between ceiling joists (loft space) Extensions 0.30 Renovations 0.35 (0.70)1 0.20 0.20 (0.35)1 0.16 0.16 (0.35)1 1 If the current element is worse than the U-value quoted in brackets, then they should be upgraded to the adjacent U-value. Cavity walls can be upgraded to just 0.55. In Scotland, Building Regulations Section 6 stipulates minimum performances typically 0.27 W/m2K for walls, 0.20 W/m2K for pitched roofs with insulation between the rafters (room-in-the-roof) and 0.16 W/m2K for pitched roofs with insulation between ceiling joists (loft spaces). Details on suitable external wall linings can be found earlier in this guide. Care should be taken to ensure any work is carried out in accordance with local planning rules, specifically where there are changes to the ridge or shape of the roof and the type of area the dwelling is located. Example systems Insulation at the ceiling (loft space) Insulation between rafters: 170mm Isover Space Saver Roll Timber fraction: 6.3% Ceiling lining: Gyproc ThermaLine laminate (see below) U-value Gyproc ThermaLine laminate 0.16 70mm Gyproc ThermaLine SUPER The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. 18 Stockist-03-02 Wall linings Studs: Timber studs at 600mm centres Insulation: Installed between the studs (see below) Timber fraction: 15% Wall lining: Gyproc ThermaLine laminate or plasterboard (see below) U-value Insulation Gyproc ThermaLine laminate / plasterboard 0.24 No insulation 90mm Gyproc ThermaLine SUPER 0.24 140mm Isover Frame Batt 35 40mm Gyproc ThermaLine PLUS 0.27 No insulation 80mm Gyproc ThermaLine SUPER 0.27 140mm Isover Frame Batt 35 27mm Gyproc ThermaLine PLUS 0.30 100mm Isover Frame Batt 35 35mm Gyproc ThermaLine PLUS 0.30 140mm Isover Frame Batt 34 12.5mm Gyproc WallBoard DUPLEX Roof lining Roof construction: Tiled or slated roof on tiling battens on sarking felt with a 50mm ventilated cavity. Softwood rafters at 600mm centres (see below) Insulation: Installed between the rafters (see below) Timber fraction: 8.3% Roof lining: Gyproc ThermaLine laminate or plasterboard (see below) U-value Insulation Gyproc ThermaLine laminate 0.19 150mm rafters with 100mm Isover Frame Batt 35 70mm Gyproc ThermaLine SUPER 0.20 125mm rafters with 75mm phenolic foam 60mm Gyproc ThermaLine SUPER 0.20 150mm rafters with 100mm phenolic foam 50mm Gyproc ThermaLine SUPER The fire resistance and sound insulation performances are for imperforate (e.g. sealed and airtight) partitions, walls and ceilings incorporating boards with all joints taped and filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum. Stockist-03-02 19 20 Stockist-03-02
© Copyright 2026 Paperzz