TKL - Precision

TKL
LED Prismatic Troffer Conversion Kit
Product Information
Project Name
Type
Catalog Number
Date
SPECIFICATIONS
Features
• Retrofits fluorescent prismatic troffers with
state-of-the-art Solid State Lighting technology.
• Output up to 6,400 lumens.
• Up to 127 lumens per watt.
• Rapid installation.
• Long-life, 60,000 hour LEDs at L80 (80% lumen maintenance)
reduces life cycle maintenance costs.
• Choice of four lumen packages and dimming option available.
• Low W/ft2 to meet the most restrictive lighting power density codes.
• Reduces job site waste by reusing existing fixture housing & prismatic lens.
• Color Rendering Index (CRI) > 80.
• Available in both 2x2 and 2x4 configurations.
• Made In USA. Meets ARRA & Buy American requirements.
Construction
•
•
•
•
•
Conversion kit includes pre-wired reflector LED assembly.
White aluminum reflector, 90-91% reflectivity.
Weight: 2x2 - 2 lbs. & 2x4 - 3 lbs.
(2) Mounting brackets.
(4) Tek screws.
Certifications
Electrical
•
•
•
•
•
•
•
•
•
•
•
•
Input Voltage Range: 100-277 VAC Nom. (90-305 V Min/Max)
Frequency: 50/60 Hz Nom. (47-63 Hz Min/Max)
Active Power Factor Correction
Power Factor: >0.90 @ full load, 100V through 277V
Inrush Current: 42 Amps max @ 220 VAC, cold start 25ºC
Harmonic Distortion: THD < 20% @ full load
Protection: Over-Voltage, Over-Temperature (110º) & Short Circuit with self-recovery
Compliant to FCC Part 15 requirements for EMI/RFI emissions
NEC/CEC compliant ballast disconnect is standard
Standard surge protection: ANSI Std. C62.41-2002 Category A (2.5 kV)
Optional surge protection: ANSI Std. C62.41-2002 Category C High (10kA and 10kV)
Optional emergency battery pack
•
•
•
•
•
•
•
UL listed 1598, 1598C and cUL for Canada.
Luminaires bear appropriate listing labels.
Emergency-equipped fixtures labeled UL 924.
Adheres to LM79, LM80 and TM21 industry standards.
Maintains insulation contact (IC) rating of existing fixture.
DesignLights Consortium® (DLC) qualified.
Please refer to the DLC website for specific product
qualifications at www.designlights.org.
• Please refer to the Lighting Facts website for specific product
qualifications at www.lightingfacts.com.
Application
• Ideal for Commercial Offices, Educational Facilities, Retail,
and Health Care Facilities.
• Suitable for use with most wired or wireless lighting control systems.
• Suitable for Dry or Damp Locations.
Warranty
• Five-year warranty. (Terms and Conditions Apply)
CERTIFICATION
ORDERING INFORMATION
–
MODEL
TKL LED
Prismatic
Troffer
Conversion
Kit
EXAMPLE TKL-2X4-LW-F-UL-35K
–
SIZE
2x2 2x2
Nominal
2x4 2x4
Nominal
–
LUMEN
OUTPUT
XL
LW
ML
HL
Extra Low
Low
Medium
High
(2x2 Only)
–
DRIVER
OUTPUT
F Fixed
DM 0-10v
Dimming1
UL
DRIVER
VOLTAGE
UL Universal
120-277 Volt
–
–
COLOR
TEMP
35K 3500
40K 4000
50K 5000
(Non DLC)
OTHER
LSP Lighting
Surge
Protector
EB Emergency
Battery
Backup2
JP Job Pack
FOOTNOTES
1. Must be used in conjunction with lighting controls. Contact factory for assistance.
2. Emergency Battery Backup: 8 Watt (2x2); 16 Watt (2x4). Lumen value with
emergency driver + battery pack: 2x2 = 692 lumens, 2x4 = 1200 lumens.
Page 1/3 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
TKL
LED Prismatic Troffer Conversion Kit
PHOTOMETRIC DATA
PHOTOMETRIC DATA: TKL-2X4-LW-DM-UL-35K
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab.
LUMINAIRE DATA
Luminaire
Ballast
Ballast Factor
Lamp
Fixture Lumens
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous Opening
in feet
INDOOR CANDELA PLOT
ZONAL LUMEN SUMMARY
90
TKL-2X4-LW-DM-UL-35K,
LED Prismatic Troffer
Conversion Kit
LED40W-036-C1100-D
1.00
LED
4023
35
Recessed
N/A
0° = 1.24 90° = 1.20
Length: 3.82
Width: 1.81
Height: 0.00
Test: L091407902
Test Date: 09/25/14
80
443
70
Zone
Lumens
%Lamp
%Fixt
0-20
0-30
0-40
0-60
0-80
0-90
647
1364
2180
3427
3939
4023
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
16
34
54
85
98
100
886
60
1328
50
1771
0
10
20
30
40
AVG. LUMINANCE (Candela/Sq. M.)
0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _
COEFFICIENTS OF UTILIZATION (%)
80
70
119
110
101
93
86
79
73
68
64
60
56
50
119
105
93
83
74
67
61
56
51
47
44
70
30
119
101
87
75
66
59
53
47
43
39
36
10
119
98
82
69
60
53
46
42
37
34
31
70
116
107
98
90
83
77
72
67
62
58
55
50
116
103
91
81
73
66
60
55
50
46
43
50
30
116
99
86
74
65
58
52
47
43
39
36
10
116
96
81
69
60
52
46
41
37
34
31
50
111
99
88
79
71
64
58
53
49
45
42
30
111
96
83
73
64
57
51
46
42
38
35
0
10
111
93
79
68
59
52
46
41
37
34
31
Average Luminance Angle
RCR
RC
RW
0
1
2
3
4
5
6
7
8
9
10
0
100
86
73
63
55
49
43
39
35
32
29
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
0.0
22.5
45.0
67.5
90.0
1771
1757
1736
1700
1647
1573
1470
1335
1166
966
771
601
471
353
261
197
148
80
1771
1762
1740
1704
1649
1573
1467
1328
1157
966
774
584
435
311
233
179
126
73
1771
1763
1741
1702
1644
1562
1452
1313
1142
959
773
570
412
275
187
152
127
75
1771
1765
1741
1699
1635
1546
1434
1295
1127
936
725
528
404
312
252
203
152
97
1771
1764
1739
1695
1629
1540
1429
1293
1127
931
712
527
416
325
262
220
174
100
LUMEN PACKAGE OPTIONS
4000K DETAILS
3500K DETAILS
Proposed
System
TKL-2X2-XL
TKL-2X2-LW
TKL-2X2-ML
TKL-2X2-HL
TKL-2X4-XL
TKL-2X4-LW
TKL-2X4-ML
Light Source
Quantity & Type
1
1
1
1
1
1
1
TKL XL Engine
TKL LWEngine
TKL ML Engine
TKL HL Engine
TKL XL Engine
TKL LWEngine
TKL ML Engine
CRI
CCT
Lumens
Per Fixture
>80
>80
>80
>80
>80
>80
>80
3500K
3500K
3500K
3500K
3500K
3500K
3500K
2200
2803
3186
4695
2854
4023
5138
Input
Watts
Lumens
Per Watt
23
30
35
52
25
35
48
97
94
91
91
114
116
108
CCT
Lumens
Per Fixture
Input
Watts
Lumens
Per Watt
4000K
4000K
4000K
4000K
4000K
4000K
4000K
2356
3048
3355
4832
3212
4445
5537
23
30
35
52
25
37
48
104
102
95
93
127
121
115
*Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards.
Page 2/3 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
TKL
LED Prismatic Troffer Conversion Kit
MINIMUM DIMENSIONS OF EXISTING FIXTURE OPENING
2X2 TKL CROSS SECTION & SIDE VIEW
13.81"
2.07"
23.00" Minimum Required Opening in Existing Fixture
2X4 TKL CROSS SECTION & SIDE VIEW
13.81"
2.08"
46.69" Minimum Required Opening in Existing Fixture
*Drawings N.T.S.
FIT AND FUNCTION
Minimum dimensional requirements are above but Precision-Paragon[P2] recommends
a trial installation prior to ordering project quantities. TKL Coversion Kits are designed
to fit into most lensed-recessed prismatic troffers mounted in T-grid installation.
Page 3/3 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com