Testing the stability of fundamental constants with atomic clocks Paris, France ❏ Bureau National de Métrologie – SYstèmes de Référence Temps-Espace H. Marion, F. Pereira Dos Santos, M. Abgrall, S. Zhang, Y. Sortais, S. Bize, I. Maksimovic, D. Calonico, J. Grünert, C. Mandache, P. Lemonde, G. Santarelli, Ph. Laurent, A. Clairon and C. Salomon (LKB) Boulder, Colorado, USA ❏ National Institute of Standards and Technology S. Bize, S.A. Diddams, U. Tanaka, C.E. Tanner, W.H. Oskay, R.E. Drullinger, T.E. Parker, T.P. Heavner, S.R. Jefferts, L. Hollberg, W.M. Itano and J.C. Bergquist 1 Testing the stability of the fine structure constant with atomic clocks - Motivations ❏ Theoretical predictions – Unified theories allow a variation of fundamental constants with time and space T. Damour et al., Nucl. Phys. B 423, 532 (94) – Recent prediction : the present drift rate of a could be as high as 10-16 yr-1 T. Damour et al., Phys. Rev. Lett 89, 081601 (02) ❏ Recent experiments – based on the observation of the spectrum of quasars – measure a change of a on cosmological time scale (at the 4σ level) z = 2 ⇔ T ~ 10 Gyr ∆α = − (0.72 ± 0.18 )× 10 −5 ; 0.5 < z < 3.5 α Webb et al., Phys. Rev. Lett. 87, 091301 (01) ❏ Interesting range for new laboratory experiments α& ≤ 10 −15 yr −1 α 2 Testing the stability of the fine structure constant with atomic clocks - Method ❏ Frequency of electronic transitions in atoms and ions ν i ≈ R y × f i (α ) – fi(a) includes relativistic effects, many-body effects, spin-orbit coupling • Dzuba et al., PRA 59, 230 (99) æ ν ö æ α ∂f 2 α ∂f1 ö δα ÷÷ × δ lnçç 2 ÷÷ = çç − è ν 1 ø è f 2 ∂α f1 ∂α ø α ❏ Frequency of the ground hyperfine transition in alkali-like atoms and ions ν HFS me 2 ≈ Ry × g I α × F (Z , α ) mp ❏ Atomic frequency comparisons – Optical vs optical: (ν2/ ν1)~ f2(a)/ f1(a) Þ a – Hyperfine vs optical: (ν2/ ν1)~ g2(me/mp)a2 F(Z2, a)/f1(a) – Hyperfine vs hyperfine (ν2/ ν1)~ g2F(Z2, a)/ g1F(Z1, a) 3 Sensitivity to a variations: coefficients ❏ Electronic transitions ν i ≈ R y × f i (α ) ❏ Hyperfine transitions ν HFS ≈ Ry × g I me 2 α × F (Z , α ) mp ❏ Mercury 199Hg+ and neutral 40Ca optical clocks α ∂f Hg + α ∂f Ca ≈ −3.2 ; ≈ +3.0 × 10 − 2 f Hg + ∂α f Ca ∂α – – 199Hg+: strong sensitivity to a; negative sign 87Sr should be calculated ❏ Rubidium 87Rb, cesium 133Cs and mercury 199Hg+ microwave clocks α ∂FHg + α ∂FCs α ∂FRb ≈ +0.74; ≈ +2.2 ≈ +0.30; FRb ∂α FCs ∂α FHg + ∂α ❏ Sensitivity to a variations: – – – 199Hg+(optical) vs Cs(hfs): -6.0 87Rb(hfs) vs 133Cs(hfs) : -0.44 199Hg+(hfs) vs H : +2.2 4 Experiment at NIST: 199Hg+(optical) vs Cs(hfs) ❏ 199Hg+ ion: energy levels: ❏ Clock transition: – 282 nm ⇔ 1.06×1015 Hz – Electric quadrupole transition – Natural linewidth: ~ 2 Hz – Qat ~ 5×1014 ❏ Laser cooling and detection: – 194 nm – Lifetime excited state: ~2 ns – Doppler cooling limit: 1.7 mK 5 The cryogenic spherical quadrupole trap ❏ Ring inner diameter: 0.8 mm ❏ Radial secular frequency: νr ~1.2 MHz ❏ High collection efficiency ❏ T=4 K ❏ Lifetime of a single ion in the trap: >3 months 6 Laser stabilization scheme at 563 nm ❏ Frequency fluctuations of the dye laser are corrected with high bandwidth (~2 MHz) ❏ The reference cavity has high finesse (F ~ 200000) and high stability ❏ The long term drift of the reference cavity (40 mHz.s-1 to several 100 mHz.s-1) is compensated 7 Spectroscopy of the clock transition ❏ Beatnote between 2 stable light sources – σy(τ)=3×10-16 for τ=1 to 30 s – below the quantum projection noise limited stability of the 199Hg+ clock ❏ Spectroscopy of the recoiless clock transition – Atomic quality factor exceeding 1014 ~ 6.5 Hz Tprobe = 120 ms 8 Systematic frequency shifts in the 199Hg+ optical clock ❏ Uncertainties (preliminary) – Corrections and 1s uncertainties in Hz at 1.06×1015 Hz (282 nm) Effect Second order Zeeman effect @ B=2.7 G Black Body radiation shift @ T=300K Black Body radiation shift @ T=4K Second order Doppler secular motion Second order Doppler micromotion 4 Background collisions ( He) Quadrupole shift -2 @ ∇E=10 V.mm Correction Uncertainty +1 386 3.4 +0.079 <0.01 0 0 <0.003 0.003 <0.1 0.1 0 0 <1 <1 Quadratic sum NIST F1+ Maser ensemble 3.7 4 ❏ Accuracy (preliminary) – 10 Hz at 282 nm ⇔ 10-14 ❏ Improvements Þ accuracy < 10-16 9 Phase-coherent RF to optical frequency measurement - All optical clock ❏ For absolute optical frequency measurements – Precision RF sources and frequency counter are referenced to a primary standard (NIST maser ensemble + NIST-F1) ❏ All optical clock – fb and f0 are referenced to fr – The clock output is fr=fHg+/m (m~106) 10 Measurements of the 199Hg+ clock frequency ❏ Stability of the maser: σy(τ =1s)=2×10-13 ❏ Contribution of the comb: σy(τ =1s)~2×10-14 ❏ Stability of the Hg+ clock: σy(τ)=7×10-15 τ -1/2 νHg+ = 1 064 721 609 899 143.7 Hz ❏ Stability of νHg+/νCs : d æ ν Hg + ö ÷÷ < 7 × 10−15 yr −1 lnçç dt è ν Cs ø Th. Udem et al. PRL 86, 4996 (2001) S.A. Diddams et al. Science 293, 825 (2001) 11 Experiment at BNM-SYRTE: 87Rb(hfs) vs 133Cs(hfs) ❏ 87Rb atom: energy levels ❏ 133Cs energy levels: – Similar – The frequency of the hyperfine splitting of 133Cs is conventionally set to 9 192 631 770 Hz to define the SI unit of time 12 Principle of operation of a cold atom fountain ❏ Nat~2×109 ❏ σr~1.5−3mm ❏ T~1µK ❏ V~4m.s-1 ❏ H~1m ❏ T~500ms ❏ Tc~0.8-2s 13 87Rb cold atom fountain 14 Spectroscopy of the clock transition: Ramsey fringes 1.0 1.0 0.8 0.6 0.4 0.8 0.94 Hz 0.2 0.0 -1.0 -0.5 0.0 0.5 1.0 0.6 0.4 0.2 0.0 -100 -50 0 50 100 detuning (Hz) ❏ Teff=534 ms ❏ Linewidth : 0.94 Hz ❏ Atomic quality factor : Qat=9.82×109 ❏ No averaging, one measurement of P per point ❏ Noise on the measurement of P: σδP=3.3 ×10-4 ❏ Signal to noise ratio : 1/σδP=3000 15 Systematic frequency shifts in atomic fountains ❏ Fractional corrections and uncertainties (×1015) Effect Second order Zeeman Black Body radiation shift Cold collisions Cavity pulling Recoil Residual First order Doppler Background collisions Ramsey and Rabi pulling Microwave leakage Correction Uncertainty -177 0.5 +173 0.2 +9.5 0.5 0 0 0 0 0 Quadratic sum 0.1 0.4 0.1 0.1 0.1 0.9 ❏ Typical accuracy of a fountain frequency standard: 1 part in 1015 ❏ Typical systematic uncertainty in the Rb vs Cs frequency comparison: 1.4 part in 1015 ❏ Improvements Þ accuracy of a few parts in 1016 16 Fountain ensemble at BNM-SYRTE 17 Rb vs Cs frequency comparisons -14 Maser Frequency (10 ) ❏ Stability of a fountain vs the H-maser: σy(τ)~1.2×10-13 τ -1/2 ❏ Frequency resolution between two fountains: σy(τ =1day)~1.1×10-15 ❏ Additional contributions from H-maser in case of imperfect overlap Pharao 15 FO1 Rb 10 5 2/27/00 3/28/00 4/27/00 ❏ Results: νRb = 6 834 682 610.904 324 (10) Hz d æ ν Rb ö ÷÷ = (0.2 ± 7.0) × 10−16 yr −1 lnçç dt è ν Cs ø 18 Summary ❏ 199Hg+(optical) vs 133Cs(hfs) at NIST: d æ ν Hg + ö ÷÷ < 7 ×10 −15 yr −1 lnçç dt è ν Cs ø me 6.0 ö÷ d æç ln g Cs α < 7 × 10 −15 yr −1 ÷ dt çè mp ø ArXiv:physics/0212109 Accepted for publication in Phys. Rev. Lett. ❏ 87Rb(hfs) vs 133Cs(hfs) at BNM-SYRTE: d æ ν Rb ö ÷÷ = (0.2 ± 7.0) ×10 −16 yr −1 lnçç dt è ν Cs ø d æ g Cs 0.44 ö lnçç α ÷÷ = (0.2 ± 7.0) × 10 −16 yr −1 dt è g Rb ø ArXiv:physics/0212112 Accepted for publication in Phys. Rev. Lett. ❏ Under the assumption that a alone is changing, these results can be compared to previous work: – Prestage et al., Phys. Rev. Lett 74, 3511 (95): • 199Hg+(hfs) vs H(hfs) d ln (α ) < 3.7 × 10 −14 yr −1 dt – This work: improvement by a factor ~25-30 d ln (α ) < 1.4 × 10 −15 yr −1 dt 19 Prospects ❏ Improvements of the 199Hg+ clock – the magnetic field will be reduced – the electric-quadrupole shift will be measured – A second 199Hg+ clock has been constructed to perform measurements with σy(τ)<10-14 τ -1/2 – Accuracy below 1 part in 1016 should be possible ❏ Improvements of cold atom fountains – Improved method to continously measure the cold collision shift – Use of SCO as interrogation oscillator to perform measurements with σy(τ) ~ 10-14 τ -1/2 – Accuracy of a few parts in 1016 should be possible ❏ New tests with other clocks using the powerful femtosecond laser based method for optical frequency comparisons – Neutral 40Ca at NIST – Neutral 87Sr at BNM-SYRTE 20
© Copyright 2026 Paperzz