Milestone Event Notification in FLIR A310 PT

Application Note
Milestone Event Notification in FLIR
A310 PT
Prepared for:
Prepared by:
Approved:
Authorization:
FLIR Systems
FNS Applications Team
Project Manager
Project Manager
Document Code:
Revision:
Date:
EN4009/2014v1.0
1.0
4/04/2014
FLIR Networked Systems
Av. Bruselas, 15 – Tercero
28108 Alcobendas (Madrid) - Spain
Tel: +34 (91) 490 40 60
Fax: +34 (91) 662 97 48
© FLIR Networked Systems, 2014
This document may only be reproduced partially or completely, archived, photocopied or transmitted in any way through
electronic media with previous written permission from FLIR Networked Systems. It shall also be referenced when used
as a source of information.
Genetec Driver Setup
DOCUMENT STATUS
Version
Date
0.0
1.0
31/03/2014
04/04/2014
Nexus VMS Drivers
Pages
Change(s)
Revised
Draft for revision
Manager revision
Page 2 of 12
EN4009/2014v0.0
Genetec Driver Setup
TABLE OF CONTENTS
1. INTRODUCTION ........................................................................................... 4 2. ITEMS REQUIRED ........................................................................................ 4 3. FLIR CAMERA SETUP ................................................................................. 5 8 3.1 Alarm ID
4. MILESTONE XPROTECT CORPORATE SETUP ........................................ 9 Nexus VMS Drivers
Page 3 of 12
EN4009/2014v0.0
Genetec Driver Setup
1. Introduction FLIR A310 PT offers the possibility to integrate Event Notification in Milestone software. This feature is available for Milestone Corporate XProtect 6.0a and Milestone Enterprise XProtect 8.1a and 8.5b. Other Milestone builds are not certified to use this feature with FLIR cameras and a correct behavior is not guaranteed. This guide explains step by step how to receive the radiometry alarm notification from a FLIR A310PT in Milestone Corporate XProtect 6.0a. 2. Items Required The following firmware combination is needed in order to complete the procedure described in this document. Note IP addresses shall be configured according to each network configuration: 

FLIR A310 PT camera o Nexus Server version 2.5.16.0 o Firmware version: WW1.4.2 + Millestone Messaging Patch o Known static IP: 10.22.1.230 Computer running Milestone Corporate XProtect built 6.0a: o Milestone XProtect Management Client - Known static IP: 10.22.1.156 (set IP according to network configuration) o Milestone XProtect Smart Client 6.0a - Known static IP: 10.22.1.156 Nexus VMS Drivers
Page 4 of 12
EN4009/2014v0.0
Genetec Driver Setup
3. FLIR Camera Setup This section describes how to configure the FLIR A310PT camera in order to make the alarm event notifications available in Milestone Corporate XProtect Corporate. Refer to FNS App Note PT, D, F‐Series and A310PT Milestone Corporate XProtect 6.0a Setup to learn how to bring A310PT into Milestone software. Once the A310PT has already been added and can be managed from Milestone Software, follow the steps below to make the radiometry alarm event notifications available on this VMS. 1. Type the camera´s IP address on your web browser address bar to access the camera’s Web Configuration Interface. 2. Go to Maintenance  Sensor  Modules  Alarm Manager. 3. Configure the Alarm Manager Modules according to the configuration below. When multiple measurement items are configured there should be a rule per item (spot/box). If the user does not want to make a difference between the alarms of the different items, only one rule is necessary. Note all the settings have to be configured as the screenshot below shows. The user can adjust items 1 to 3 according to their requirements. Nexus VMS Drivers
Page 5 of 12
EN4009/2014v0.0
Genetec Driver Setup
# Description 1 If the user wants to differentiate among the different radiometry alarms from the different measurement items. Set as many rules as items indicating which item the alarm is coming from. 2 Corresponds to the measurement item Alarm ID. When an alarm is triggered on a given ID the rule will apply. Refer to section 3.1 to learn how find the Measurement ID. 3 This subject will be taken into account in the Milestone software to receive the event notification. If you have several Rules corresponding to each Measurement item, choose this subject to represent where the alarm is coming from. Example: A310PTBox1. Nexus VMS Drivers
Page 6 of 12
EN4009/2014v0.0
Ge
enetec Drive
er Setup
or the changes to take efffect. 4. Click on the saave button fo
o to Maintenance  Seerver  Servvices  Msg
g Systems an
nd scroll dow
wn to the seection 5. Go
M
Milestone Gen
neric Events N
Notification. Complete th
he information as follow
ws: - Milestone
e Server IP: IP address w
where the M
Milestone XProtect Clientt Manager w
will be runningg. - Port: it iss usually 123
34, go to se
ection 4, step 3 to check this value in the Mileestone softwarre. Make sure the Window
ws Firewall configuration in the PC
C running Milestone sofftware und and outbound trafficc through this port. allows inbou
or the changges to take efffect. 6. Click on the Saave button fo
o to Mainten
nance  Serrver  Servicces  Notifiication List. IIn the Default Notificatio
on List 7. Go
seection, checkk the Milesttone Genericc Events Notification op
ption. The teext below will w be taken into acccount for thee XML notification conten
nt. or the changges to take efffect. 8. Click on the Saave button fo
9. Reestart the server. Nexus VMS Driv
vers
Page 7 of 12
2
EN4009
9/2014v0.0
Genetec Driver Setup
3.1 Alarm ID In order to configure the Alarm Module described in section 3, the user needs to know the Alarm Id linked to each measurement item. To differentiate when an alarm is triggered in each item, a different rule will have to be configured per item. The Alarm Id can be checked with FLIR Sensors Manager (FSM) or the camera’s Web Configurator tool: - FSM: Access the IR Advanced Sensor Control panel and click on the Alarms Tab. - Web configurator Tool: Go to Setup  Radiometry and click on the toggle grid of items icon. Nexus VMS Drivers
Page 8 of 12
EN4009/2014v0.0
Genetec Driver Setup
4. Milestone XProtect Corporate Setup This section will describe the process to link a Generic Event in Milestone software to the triggered radiometry alarm of a FLIR A310 PT – Series. In order to follow the process below the camera has to be already added to Milestone software, if this is not the case refer to FNS App Note PT, D, F‐Series and A310PT Milestone Corporate XProtect 6.0a to complete this task. Once the camera is added to Milestone, follow the steps below: 1. Open the Milestone XProtect Management Client. 2. Access the Tools Menu  Options and click on the Generic Events Tab. 3. Add the camera’s IP address to the allowed IP address box. Nexus VMS Drivers
Page 9 of 12
EN4009/2014v0.0
Genetec Driver Setup
4. Click OK to make the changes effective and close the menu. Note that the A310PT will send a notification when the alarm temperature condition is met and another one when the alarm condition is not met anymore. Below are the steps to create two Generic Events to register these two conditions in Milestone software. 1.
2.
3.
4.
Go to Rules and Events and click on Generic Events. Right Click on Generic Event to add a new event. Specify a name for the event and click on OK. Fill the event information as shown in the picture below. Note the Expression field would have to match the Subject setting configured in the Alarm Manager Module (refer to Section 3, step 3, item number 3 on the image). In this case, the event will be linked to the alarm state ON: Nexus VMS Drivers
Page 10 of 12
EN4009/2014v0.0
Ge
enetec Drive
er Setup
Add a new event. In this case, the evvent will be liinked to the alarm state OFF: 5. A
Nexus VMS Driv
vers
Page 11 of 12
2
EN4009
9/2014v0.0
Ge
enetec Drive
er Setup
At this point the Milestone XP
Protect Clien
nt Manager w
will be receivving the notiifications. In order ons and select the to check the conffiguration, acctivate the EEvent log on the Tools Menu  Optio
Make sure th
he Event log is enabled on this tab. Serveer Logs tab. M
n the two events e
configgured are reeceived, thee Event Log will show th
he correspondent When
entriees: Nexus VMS Driv
vers
Page 12 of 12
2
EN4009
9/2014v0.0