Traffic lights for reversible lanes ARROW

Traffic lig ht s for reversible lanes
ARROW-CROSS
ROAD SAFETY
T
he traffic lights for reversible lanes known as arrow-cross are
Variable message signs (VMS) with illuminated Pictograms defaults,
which are normally placed near highways, tunnels or wherever it is
necessary to handle the accessibility of gangways and possibly blocking access or reroute traffic..
These panels have the ability to view the following Pictograms:
• Vertical Green arrow with tip directed downwards;
• Yellow arrow inclined 45 degrees downward to the right;
• Yellow arrow inclined 45 degrees downward to the left;
• Red Cross shaped like an “X”.
Arrow-Cross VMS are developed according to UNI_EN-12966
standards, marked with CE and homologated by the Italian Ministry of
Infrastructure and Transport.
ROAD SAFETY
GENERAL CHARACTERISTICS
➤ Automatic brightness adjustment on 16 levels (using ambient light reading) and/or on specific remote control from the
control unit.
➤ Perimeter edge front contrast neutral as per rules.
➤
Aluminium front plate black coated, isolated at the LED and made waterproof by affixing polycarbonate outdoor U.V. and
anti-glare treaty.
➤ Internal control unit with microprocessor for managing the panel, accessories and services for the detection of
anomalies.
➤ Immediate control interventions in case of fault.
➤ Different levels of intervention depending on the severity of the event.
➤ Recording of anomalies for diagnosing from the remote system.
➤ Automatic management or piloted by the remote system.
➤ Welded aluminium container, painted.
TECHNICAL CHARACTERISTICS
Matrix
Graphic with three LED (red, green, yellow)
Matrix dimension
300mm x 150mm
Number matrix
4
Step between pixel
18.75 mm
Active area
500mm x 500mm
Duration
> 300.000 ore
Optical characteristics
(according to EN12966-1 European
standard)
• Luminance: L3 Class
• Contrast: R2 Class
• Read angle (horizontal and vertical): B4/B6 Class
Operating temperature
From - 40 °C to +85 °C, T2 of the standard Class
IP rating
IP55, P2 of the standard Class
Pollution
D2 Class
Power supply
230Vac (-13% /+10%), 50 Hz
Dissipated power
0,5 kW