Solar collector racking system
CALEFFI
NAS100 series
01281/14 NA
ACCREDITED
ISO 9001 FM 21654
Replaces 01281/13 NA
ISO 9001 No. 0003
Function
The StarMax V™ collectors must be mounted to two horizontal NAS100
series four slot rails. The StarMax V™ frame will accept the collector clip
(in code NAS10006 or NAS10007 kits) mounted along the collector
sides without drilling or tapping so the integrity of the frame wall is not
compromised. The NAS100 series four slot rail has four 9/16" slots
which accept standard stainless steel 3/8" bolts and nuts for mounting
collector clips and U-mounts to flashing. The NAS100 series aluminum
6005-T5 four slot channel rail can span 7 feet in moderate wind and
snow loads installations.
The NAS10041 2" U-mount mounts directly on top of NAS10030 roof
flashing with a 3/8" standard stainless steel nut and attaches into the
side slots of the NAS100 series rail using NAS10042 stainless steel
3/8"-16 x 1" bolts, nuts & washers.
Product range
NAS10040-1
NAS10040-2
NAS10040-20
NAS10041
Four slot rail for one collector ...................................................................................................................................... length 58 inches
Four slot rail for two collectors.................................................................................................................................. length 108 inches
Four slot rail for cutting to custom length.................................................................................................................. length 240 inches
U-mount for attaching NAS100 series four slot rails ............................................................................................................ size 2 inch
Technical specifications
Materials - rail:
- color:
- size
- weight
- u-mount
6005 T5 aluminum
silver
2" x 58", 2" x 108", 2" x 240"
58"= 6 lbs., 108"= 10 lbs., 240"= 22 lbs.
aluminum
Note: The base plate is normally attached to the roof with a 5/16" or
3/8" lag bolt (not included). Flashing is attached to the base plate
using the NAS10030 roof flashing kit.
7/8" x 3/8"
7/8" x 3/8"
Dimensions
A
A
A
A
D
7/8" x 3/8"
D
D
7/8" x 3/8"
D
C
B
C
C
B
B
D
C
D
B
Code
A
NAS10040-X
2"
B
⁄8"
3
C
⁄16"
9
D
Code
A
B
C
D
⁄2"
NAS10041
3"
2 1⁄4"
2"
2"
1
NAS100 series four slot rail maximum spans (ft)
Wind speed (mph)
90
100
110
120
130
140
150
0 psf snow*
Interior
Edge
9' 3"
9' 3"
9' 3"
8' 9"
9' 3"
7' 9"
8' 6"
7' 3"
7' 9"
6'
7' 3"
5' 3"
6' 3"
4' 6"
20 psf snow*
Interior
Edge
7'
7'
7'
7'
7'
6' 6"
7'
5' 9"
6' 6"
5' 6"
5' 9"
5' 3"
5' 6"
4' 6"
40 psf snow*
Interior
Edge
5' 9"
5' 9"
5' 9"
5' 9"
5' 9"
5' 9"
5' 9"
5' 9"
5' 9"
5' 3"
5' 6"
4' 9"
5' 3"
4' 6"
Assumptions:
*Roof Snow Load listed, linear interpolation is permitted in most cases, edge zone is
approximately 3 feet from ridge line and eaves.
- Building height must be less than or equal to 30 feet
- Maximum cantilever is 18"
- Rail splices not permitted immediately over supports or within middle 1/3 of span
For installations that do not conform to the assumptions listed above contact Caleffi
for a more complete engineering
60 psf snow*
Interior
Edge
4' 6"
4' 6"
4' 6"
4' 6"
4' 6"
4' 6"
4' 6"
4' 6"
4' 6"
4' 6"
4' 6"
4' 6"
4' 6"
4' 6"
100 psf snow*
Interior
Edge
3' 3"
3' 3"
3' 3"
3' 3"
3' 3"
3' 3"
3' 3"
3' 3"
3' 3"
3' 3"
3' 3"
3' 3"
3' 3"
3' 3"
Key
Wind speeds & low snow loads
Wind speeds & moderate snow loads
Wind speeds & high snow loads
Edge zone
A. If the collector array is mounted with top edge within 3 feet of the
ridge line, which is in the edge zone, the entire array must comply
with the edge zone maximum span distances between supports as
specified in the above table.
B. If the collector array is mounted with the side edge within 3 feet of
the eave, which is in the edge zone, the individual collector mounted
within the edge zone must comply with the edge zone maximum
span distances between supports as specified in the above table.
Refer to the above NAS100 series four slot rail maximum span table for
the maximum span between the supports. Cantilever distance is not
exceed 18". The mounting support locations must be located to comply
with the maximum span and cantilever distances for both the length and
width dimensions as shown in these diagrams.
3'
edge
zone
A
[
3'
edge
zone
B
[
NAS100 ™
QuadTrac
Fourrail
slot rail
]
StarMax V™
solar collector
StarMax V™
solar collector
StarMax V™
solar collector
Support
Support
Cantilever
distance
StarMax V™
solar collector
Span
distance
Support
Span
distance
Cantilever
distance
NAS10006 tilt mounting kit
Function
Caleffi’s NAS10006 mounting kit allows StarMax V™ collectors to be tilt
mounted. Collectors may be mounted to any roof, vertical wall, fascia
board, pre-constructed rack or ground mount system. The StarMax V™
collectors must be mounted to two horizontal Caleffi NAS100 series four
slot rails or any U type rails (see illustration). The four slot rail collector
frame wall will accept the collector clip mounted along the collector
sides without drilling or tapping so the integrity of the frame wall is not
compromised. The optional rear extension tubes can be cut to length
allowing proper elevation and orientation.
Pivot shoes and collector clips are mill finshed and extruded from high
tensile strength 6005-T5 aluminum. All stainless steel bolts, nuts and
washer are made of 304 stainless steel materials and certified to ASTM
F593C and ASTM F594C standards.
Tilt mounting
The tilt mounting kit allows for the collectors to be angled differently than
the orientation of the surface they are secured to. This is achieved by
placing two rails to the back of the collector and attaching the collector
clips, pivot shoes and U-mounts included in hardware kit shown below.
The mounting rails and tilt extension tubes are available separately.
Hardware for tilt mounting installation
6 — U-mounts formed aluminum 5052-H32
2 — Pivot shoes extruded aluminum 6005-T5
4 — Collector clips extruded aluminum 6005-T5
8 — Bolts 3/8"-16 x 1" stainless steel ASTM F593C
6 — Bolts 3/8"-16 x 2" stainless steel ASTM F593C
14 — Washers 3/8" stainless steel SAE 304
14 — Nuts 3/8"-16 stainless steel ASTM F594C
Collector
clip, bolt & nut
Four
slot rail
™
QuadTrac
rail
U mount 1"
Strut nut
& U Strut rail
Collector
clip & bolt
Pivot shoe
bolt & nut
U mount 1"
Completed installation
Optional mounting rails and tilt extension tubes
2 — NAS10040-1 Four slot 58" rails for one collector
2 — NAS10040-2 Four slot 108" rails for two collectors
2 — NAS10002 Tilt extension 72" tubes for each collector
2 — NAS10005 Tilt extension 144" tubes for each collector
™ or U-strut rail
Four slot
QuadTrac
or U Strut rail
™
QuadTrac
or U Strut rail
(not
(notincluded)
included)
(not included)
Four slot or U-strut rail
QuadTrac™ or U Strut rail
(not included)
(not included)
QuadTrac™ or U Strut rail
(not included)
Tilt extension tubes
Tilt
(notextension
included)tubes
(not included)
View of bottom of collector
View of top of collector
NAS10007 flush mounting kit
Function
Caleffi’s NAS10007 mounting kit allows StarMax V™ collectors to be
flush mounted to any elevated surface or ground mount system. The
StarMax V ™ collectors must be mounted to two horizontal Caleffi
NAS100 series four slot rails or suitable U type rails (see illustration). The
four slot rail collector frame wall will accept the collector clip mounted
along the collector sides without drilling or tapping so the integrity of the
frame wall is not compromised.
Collector clips are mill finished extruded aluminum from 6005-T5 high
tensile strength aluminum. All stainless steel bolts, nuts and washer are
made of 304 stainless steel materials and certified to ASTM F593C and
ASTM F594C standards.
Collector clip
The tilt and flush mounting kits contain
collector clips which have a unique
concave shape with a hole in the center
that when tightened, with supplied
3/8"-16 x 1" stainless steel bolt to rails,
tension is formed on the bolt nut which
keeps clip fastened securely.
Flush mounting
The flush mounting kit allows for parallel mounting on a sloped roof
surface. This is achieved by placing two mounting rails to back of the
collector and attaching with collector clips included in hardware kit
shown below. Mounting rails and U-mount 2" are available separately.
Hardware for flush mounting installation
4 — Collector clips extruded aluminum 6005-T5
4 — Bolts 3/8"-16 x 1” stainless steel ASTM F593C
4 — Washers 3/8" stainless steel SAE 304
4 — Nuts 3/8"-16 stainless steel ASTM F594C
Optional mounting rails and U-mounts
2 — NAS10040-1 Four slot 58" rails for one collector
2 — NAS10040-2 Four slot 108" rails for two collectors
4 — NAS10041 U-mount 2" for attaching NAS100 four slot rails
Collector clip,
bolt & nut
Four slot rail ™
QuadTrac
rail
U mount
2"
Collector clip & bolt
Strut nut
& U Strut rail
Completed installation
NAS10030 Roof flashing kit
Function
The Caleffi NAS10030 roof flashing kit provides a sturdy two-bolt
application tested to withdrawal strengths of 5,230 lbs. The attractive
low profile design (3/4") allows mounting closer to the roof and works
well with racking systems. The simple design has fewer components
to minimize installation labor. Water stays out because there are no
exposed rubber or threads. Allows compatibility with any racking and
standoff components, for simpler more cost effective installation.
The NAS10030 flashing kit inclues 3/8" stud for attaching U-mounts
and other brackets using the supplied 3/8" stainless steel nut & washer.
Black painted aluminum (6061-T6) flashing 14-3/4"L x 9-1/2"W x 0.6"H,
galvanized steel base plate with six mounting holes and double stud.
Product range
Code NAS10030 Roof flashing kit, including galvanized steel base
plate
Code NAS10032
Galvanized steel base plate
Technical specifications
Flashing assembly exploded view
4"
steel; zinc plus nickel plated,
3/8-16 x 5/8", 1.5" hex
- washer:
higher temperature polymer,
1.0" O.D. x 3/8" I.D. x 0.094" thick
- flashing:
aluminum (6061-T6)
14.5"L x 9.5"W x 0.6" thick
- base plate:
galvanized steel
3-7/8"L x 3"W x 0.52" thick
Note: Base plate fastening hardware is not included.
Note: The flashing sits on top of the base plate, and is attached with
the NAS10030 assembly.
Note: The base plate is normally attached to the roof with 5/16" or
3/8" lag bolts (not included). Flashing is attached to the base plate
using the NAS10030.
9.5"
Materials - NAS10030:
4"
14.75"
Flashing assembly profile
Four slot or U-strut rail
NAS10030
(not included)
Encapsulated
gland washer
Flashing
Base plate*
*Base plate, code NAS10032, included in the flashing kit, code NAS10030. Base
plate fastening hardware not included, source separately.
Accessories
Item
Code
NAS10002
NAS10005
NAS10042
Description
Item
Square aluminum (6005-T5)
extension tube for
tilting collectors
1" square tube x 6'
1" square tube x 12'
Code
NAS10023
Description
Four slot rail splice bar,
aluminum (6005-T5), requires
2 bars for each splice, includes
3/8"-16 stainless steel bolts
and washers
Bolt, nut & washer kit. Two
stainless steel 3/8"-16 x 1" bolts,
nuts & washers, ASTM F593C
SPECIFICATION SUMMARIES
Solar collector racking system
Aluminum, 6005-T5 four-channel 2 inch rail with four 9/16" slots which accept standard 3/8" stainless steel bolt heads, and nut for mounting collector clips
and U-mounts for flashing. Two rails used for horizontal support for collectors, 58 inch length for one collector, 108 inch length for two collectors, and
240 inch length for cutting to length. Must be able to span 7 feet for moderate wind and snow loads installations. Provide with code NAS10006 tilt mounting
kit, code NAS10007 flush mounting kit, code NAS10030 roof flashing kit, code NAS10032 galvanized steel base plate, code NAS10023 splice bars and 1
inch square tube extensions code NAS10002 6 foot length, code NAS10005 12 foot length, code NAS10041 2 inch U-mount.
We reserve the right to change our products and their relevant technical data, contained in this publication, at any time and without prior notice.