35-7/8" 24-3/8" 39" 3" 81-3/8" CASE 5-1/8" 62

BREMA 6
PAGE 1
SECTION VIEW FLAT CANOPY
35-7/8"
3"
81-3/8"
CASE
62-5/8"
INTERIOR
65-1/8"
DOOR
22"
5-1/8"
24-3/8"
39"
DATE: 11/20/2014
BR
31690007
31690007
REV 07
ARNEG RESERVES THE RIGHT TO CHANGE OR REVISE SPECIFICATIONS
AND PRODUCT DESIGN IN CONNECTION WITH ANY FEATURE OF ITS
PRODUCTS. SUCH CHANGES DO NOT ENTITLE THE BUYER TO
CORRESPONDING CHANGES, IMPROVEMENTS, ADDITIONS, OR
REPLACEMENTS FOR EQUIPMENT PREVIOUSLY SOLD OR SHIPPED.
CASE DESIGN CONDITION NOT TO EXCEED 75° F & 55% RH
BREMA 6
PAGE 2
SECTION VIEW SHARK NOSE CANOPY
38-1/2"
3"
81-3/8"
CASE
62-5/8"
INTERIOR
65-1/8"
DOOR
22"
5-1/8"
24-3/8"
39"
DATE: 11/20/2014
BR
31690007
31690007
REV 07
ARNEG RESERVES THE RIGHT TO CHANGE OR REVISE SPECIFICATIONS
AND PRODUCT DESIGN IN CONNECTION WITH ANY FEATURE OF ITS
PRODUCTS. SUCH CHANGES DO NOT ENTITLE THE BUYER TO
CORRESPONDING CHANGES, IMPROVEMENTS, ADDITIONS, OR
REPLACEMENTS FOR EQUIPMENT PREVIOUSLY SOLD OR SHIPPED.
CASE DESIGN CONDITION NOT TO EXCEED 75° F & 55% RH
BREMA 6
PAGE 3
BACK
BACK
61-1/2"
54-3/4"
92-1/4"
1-1/2"
1-1/2"
47"
38-1/2"
20-1/8"
20-1/8"
9-1/2"
24-3/8"
33-3/4"
180° SWIVEL
ROTATION
R 7-1/4"
9-1/2"
ELEC
24-3/8"
O 4"
39"
REF PIPE
ACCESS
ELEC
180° SWIVEL
ROTATION
33-3/4"
O 4"
R 7-1/4"
O 1-1/2"
21"
O 1-1/2"
21"
DRAIN
DRAIN
30-3/4"
7"
46-1/8"
7"
FRONT
FRONT
PLAN VIEW 3 DOOR 96105010US
PLAN VIEW 2 DOOR 96105000US
BACK
123"
1-1/2"
62-3/8"
53-7/8"
20-1/8"
9-1/2"
ELEC
180° SWIVEL
ROTATION
24-3/8"
33-3/4"
O 4"
O 1-1/2"
R 7-1/4"
DRAIN
39"
REF PIPE
ACCESS
21"
61-1/2"
7"
FRONT
PLAN VIEW 4 DOOR 96105020US
BACK
153-1/2"
47-3/4"
1-1/2"
51-1/4"
47-3/4"
20-1/8"
9-1/2"
360° SWIVEL
ROTATION
24-3/8"
33-3/4"
ELEC
O 4"
O 1-1/2"
O 14-1/2"
DRAIN
39"
REF PIPE
ACCESS
21"
7"
76-3/4"
FRONT
PLAN VIEW 5 DOOR 96105030US
DATE: 11/20/2014
BR
31690007
31690007
39"
REF PIPE
ACCESS
REV 07
ARNEG RESERVES THE RIGHT TO CHANGE OR REVISE SPECIFICATIONS
AND PRODUCT DESIGN IN CONNECTION WITH ANY FEATURE OF ITS
PRODUCTS. SUCH CHANGES DO NOT ENTITLE THE BUYER TO
CORRESPONDING CHANGES, IMPROVEMENTS, ADDITIONS, OR
REPLACEMENTS FOR EQUIPMENT PREVIOUSLY SOLD OR SHIPPED.
CASE DESIGN CONDITION NOT TO EXCEED 75° F & 55% RH
BREMA 6
LED Lighting @ 120V
Length
2 DR
3 DR
4 Dr
5 Dr
Quantity
2
3
4
5
Amps
0.28
0.4
0.53
0.65
Watts
33
48
63
78
PAGE 4
ECM Fans @ 120V
Quantity
2
3
4
5
Amps
0.08
0.12
0.16
0.2
Watts
9.2
13.8
18.4
23
Frame Anti-Sweat @ 120V
Length
2 DR
3 DR
4 Dr
5 Dr
Low Temperature
Anthony (ELM 2)
GDS (1200)
Amps
Watts
Amps
Watts
1.51
181
1.54
188
2.13
256
2.21
264
2.69
323
2.86
343
3.27
392
3.47
416
Defrost Heater @ 208V
Length
2 DR
3 DR
4 Dr
5 Dr
Quantity
3
3
3
3
Amps
6.24
9.42
12.57
15.48
Watts
1302
1959
2616
3219
Medium Temperature
Anthony (ELM 2)
GDS (1200)
Amps
Watts
Amps
Watts
0.77
94
1.51
181
2.13
256
1.11
132
2.69
323
1.43
171
3.27
392
1.74
208
Drain Heater @ 208V
Quantity
1
1
1
1
Amps
0.37
0.56
0.75
0.92
Watts
76
116
156
192
Refrigeration Data
Application
Medium
Frozen
Ice Cream
Parallel BTUh/Door
520
995
1065
Conv. BTUh/Door
540
1030
1110
SST (ºF)
30
-12
-21
Superheat (ºF)
6-8°
4-6°
4-6°
Discharge Temp (°F)
35
-5
-12
Velocity (FPM)
350
350
350
Defrost Settings
Defrost Type
Electric
Defrost (Day)
1
Fail Safe (Min.)
55
Termination Temperature (ºF)
50
Drip Time (Min)
3-5
Hot Gas
1
35
50
6-8
1. ArnegUSA refrigerated display cases for sale in the United States meet or exceed Department of Energy 2012 energy efficiency requirements.
2. Average DIscharge Air Velocity measured five minutes after defrost.
3. Amps are taken from electrical nameplate values, watts are actual recorded values from laboratory measurements..
4.Termination sensor located on return bend of coil.
5. Termination sensor located on hot gas return line exiting coil between distributor and check value.
6. Add 50 BTUs per door for GDS 1200 doors.
* Off Cycle defrost available for medium temperature only
DATE: 11/20/2014
BR
31690007
31690007
REV 07
ARNEG RESERVES THE RIGHT TO CHANGE OR REVISE SPECIFICATIONS
AND PRODUCT DESIGN IN CONNECTION WITH ANY FEATURE OF ITS
PRODUCTS. SUCH CHANGES DO NOT ENTITLE THE BUYER TO
CORRESPONDING CHANGES, IMPROVEMENTS, ADDITIONS, OR
REPLACEMENTS FOR EQUIPMENT PREVIOUSLY SOLD OR SHIPPED.
CASE DESIGN CONDITION NOT TO EXCEED 75° F & 55% RH