ECLIPSE WGD THROUGHPORT GAS BURNER

Bulletin 1135
7/08
ECLIPSE WGD
THROUGHPORT GAS BURNER
Luminous Flame Ensures High Heat
Transfer and Low NOx
Water cooled throughport
burners for regenerative
glass furnaces
Eclipse WGD burners are
compact water cooled burners
designed to be inserted into
the port neck of a regenerative
glass furnace. The burner is
fitted to the Eclipse retraction
mechanism to withdraw the
burner from the furnace when
not firing. Using through port
burners with the retraction
mechanism ensures the lowest
possible maintenance and
therefore consistent combustion
essential for high glass quality.
The burner produces a flat,
fan shaped luminous flame
using a unique arrangement
of converging flat jet nozzles.
Only one burner is to be used
in each port. Excellent flame
coverage of the glass is ensured
with this type of burner and
flames are extremely luminous
ensuring high heat transfer and
low NOx. The flame location
is very easily adjusted within
the furnace ensuring that
combustion is taking place
at the optimum position.
SE
LIP
EC
Features
• Single burner per port
• Reduced fuel consumption
• Refractory savings
• Reduced batch carryover
• High glass quality
• Compact burner and water jacket design
• Low NOx
• Luminous flame for high heat transfer
• Excellent flame coverage
Port Design
The correct port design is essential
for this burner. Contact your Eclipse
representative to provide the design
information for each specific application.
WGD Throughport Gas Burners
Setting new standards in versatility and flexibility for the glass industry
Cooling Water
Inlet 1-1/4” BSP
Cooling Water
Outlet 1-1/4” BSP
Converging Flat Jet
Nozzles – Provide
flat, fan shaped
luminous flame
Gas Inlets 1-1/2” BSP
SPECIFICATIONS
Burner capacity+ . . . . . . . . . . . . . . . . . .
Gas pressure . . . . . . . . . . . . . . . . . . . .
Burner length* . . . . . . . . . . . . . . . . . . . .
Burner diameter . . . . . . . . . . . . . . . . . .
Spray angle . . . . . . . . . . . . . . . . . . . . . .
Cooling water flow . . . . . . . . . . . . . . . . .
Cooling water pressure drop . . . . . . . . .
Max. cooling water supply pressure . . .
Cooling water outlet temperature . . . . .
Cooling water temperature rise . . . . . .
Water condition . . . . . . . . . . . . . . . . . . . .
1200 Nm3/h max (42,400 scfh)
250 mbar (3.6 psig)
1400mm to 2000mm (55” to 79”)
102mm (4”)
60°–100°
80 l/min (21 gpm)
1 barg (14.5 psig)
3 barg (43.5 psig)
60°C max (140°F max)
20°C max (68 °F max)
< 30 ppm hardness
< 1 ppm dissolved oxygen
* 100mm increments (~ 4”)
+ Actual input dependent on application requirements
Bulletin 1135 7/08