Pre-filters V 5 to VF 490 Microfilter and Activated Carbon Filters FP 5/A 5 to FFP 490/AF 490 V5 V 10 to V 250 with differential pressure gauge Pre-filter V EFFICIENT BOGE pre-filters are 99.99 percent efficient based on 3 µm, thus providing optimal conditions for further compressed air treatment. VF 250 to VF 490 with differential pressure gauge LAYOUT It is recommended that a pre-filter is positioned upstream of the compressed air dryer and the microfilter. They are essential when ambient air is extremely dusty or when high oil carry over is a risk. Microfilter FP and active carbon filter A FP 10 to FP 250 with differential pressure gauge FFP 250 to FFP 490 with differential pressure gauge EFFICIENT BOGE microfilters are 99.99 percent efficient based on 0.01 µm. The residual oil content after a microfilter is 0.01 mg/m³, and reduced to 0.005 mg/m³ when used in combination with active carbon filters. LAYOUT Microfilters with or without active carbon filters are best used as main filters in the compressed air line or as point of use filters. Combination of FP filter and A 10 to 250 with differential pressure gauge Combination of FFP filter and AF 250 to 490 with differential pressure gauge Differential pressure and efficiency FP Series A Series FP/A Series Differential pressure in clean condition ∆p 0,06 bar ∆p 0,03 bar ∆p 0,2 bar Efficiency 99,99999 % relative to 0,01 µm Residual oil content max. 0,01 mg/m3 Residual oil content = 0,003 mg/m3 99,99999 % relative to 0,01 µm Higher pressures and capacities are available upon request 22 BOGE AIR. THE AIR TO WORK. For ultra clean compressed air in extreme conditions: Compressed air treatment is achieved in several stages. Pre-filters are used to separate coarse impurities from the compressed air. Smaller solids and oil can be removed by means of microfilters. Finally active carbon filters are used to clean oil vapours, aromatics, flavourings and odours from the compressed air. This assures oil free and clean compressed air even in extreme conditions! BOGE Type1) Capacity 2) m3/h Connection A Aluminium housing with threaded connector as per DIN 2999 G 1⁄4 60 V5 30 87 G 1⁄4 V 10 50 G 3⁄8 87 V 12 70 87 G 1⁄2 V 20 100 G 3⁄4 130 V 30 180 G1 130 V 50 300 130 G 11⁄2 V 80 470 G 11⁄2 130 V 120 700 G2 164 V 160 940 G2 164 V 250 1450 Steel housing with flanged connector as per DIN 2633 DN 80 380 VF 250 1850 DN 80 440 VF 400 2920 DN 100 500 VF 490 3700 Dimensions in mm B D Weight kg Filter element/Number C 167 209 209 279 315 415 515 715 823 1073 14 21 21 21 43 43 43 43 48 48 60 75 90 160 135 235 335 525 520 770 0,8 1,5 1,5 1,7 4,3 5,0 5,5 6,9 9,6 17,9 1/5 V 1/10 V 1/12 V 1/20 V 1/30 V 1/50 V 1/80 V 1/120 V 1/160 V 1/250 V 1260 1310 1440 175 205 230 530 530 550 54,0 80,0 108,0 1/250 V 1/400 V 2/250 V Max. operating pressure 16 bar, 1) incl. automatic condensate drain, differential pressure gauge from V 10 onwards, 2) relative to 20 °C and 1 bar absolute at 7 bar over pressure Conversion factor f at other operating pressures bar Over-pressure f= 1 2 0,25 0,38 3 4 5 6 7 8 9 10 0,5 0,63 0,75 0,88 1,00 1,13 1,25 1,38 Differential pressure and efficiency Differential pressure in clean condition ∆p 0,02 bar Efficiency 99,99 % relative to 3 µm Higher pressures and capacities are available upon request BOGE Type 1) Capacity 2) Connection Dimensions in mm A B m3/h Aluminium housing with threaded connector as per DIN 2999 G 1⁄4 60 165 FP 5/A 5 30 1 ⁄4 87 215 G FP 10/A 10 50 G 3⁄8 87 215 FP 12/A 12 70 87 285 G 1⁄2 FP 20/A 20 100 G 3⁄4 130 325 FP 30/A 30 180 G 1 130 425 FP 50/A 50 300 525 G 11⁄2 130 FP 80/A 80 470 G 11⁄2 130 725 FP 120/A 120 700 G 2 164 825 FP 160/A 160 940 G 2 164 1075 FP 250/A 250 1450 Steel housing with flanged connector as per DIN 2633 DN 80 380 1280 FFP 250/AF 250 1850 DN 80 440 1320 FFP 400/AF 400 2920 DN 100 500 1440 FFP 490/AF 490 3700 C Combination FP/A in mm D A Weight Weight Combination FP/A Filter element Number/Type kg kg FP or A 14 21 21 21 43 43 43 43 48 48 60 75 90 160 135 235 335 525 520 770 120 174 174 174 260 260 260 260 340 340 0,8 1,5 1,5 1,7 4,3 5,0 5,5 6,9 9,6 17,9 1,6 3,0 3,0 3,4 8,9 10,7 11,6 14,2 19,7 25,8 1/ 5 FP/A 1/ 10 FP/A 1/ 12 FP/A 1/ 20 FP/A 1/ 30 FP/A 1/ 50 FP/A 1/ 80 FP/A 1/120 FP/A 1/160 FP/A 1/250 FP/A 175 205 230 530 530 550 760 880 1000 54,0 80,0 108,0 108 160 215 1/250 FP/A 1/400 FP/A 2/250 FP/A Max. operating pressure 16 bar, 1) incl. automatic condensate drain on model FP 5 onwards, differential pressure gauge on model FP 10 onwards, 2) relative to 20 °C and 1 bar absolute at 7 bar over pressure, technical data for series FP and A are identical Conversion factor f at other operating pressures bar Over-pressure f= 1 0,25 Compressed Air Treatment | Filters 2 0,38 3 0,50 4 0,63 5 0,75 6 0,88 7 1,00 8 1,13 9 1,25 10 1,38 23
© Copyright 2026 Paperzz