PEMSERT® Self-clinching Flush Fasteners F4-714 Installs flush into stainless steel sheets Type F4™ fasteners are ideal for flush applications where a stainless steel sheet requires loadbearing threads. The PEM® flush nut can be installed easily by squeezing it into a round hole in metal sheets. When the fastener is properly installed, both the top and the bottom of the sheet remain flat, enhancing the functional and cosmetic qualities of the entire assembly. The hexagonal head along with the proven PEM self-clinching design ensures high axial and torsional strength. Profile for -1 shank code. A H NEW! Inst stainlalls into ess st eel Profile for -2, -3, -4, & -5 shank codes. A Features and Benefits • Installs flush • For use in stainless steel sheets up to HRB 88 / HB 183 • Can be installed before bending sheet C C Clinching profile may vary. All dimensions are in inches. UNIFIED Thread Size .086-56 (#2-56) .112-40 (#4-40) .138-32 (#6-32) .164-32 (#8-32) .190-32 (#10-32) .250-20 (1/4-20) Type Thread Code F4 256 F4 440 F4 632 F4 832 F4 032 F4 0420 Shank Code 1 2 1 2 1 2 1 2 1 2 3 4 5 A (Shank) Max. .060 .090 .060 .090 .060 .090 .060 .090 .060 .090 .120 .151 .182 Sheet Thickness .060-.090 .091 Min. .060-.090 .091 Min. .060-.090 .091 Min. .060-.090 .091 Min. .060-.090 .091 Min. .125-.155 .156-.186 .187 Min. Hole Size In Sheet +.003 -.000 C Max. H Nom. Min. Dist. Hole C/LTo Edge .172 .171 .188 .23 .172 .171 .188 .23 .213 .212 .250 .27 .290 .289 .312 .28 .312 .311 .343 .31 .344 .343 .375 .34 Hole Size In Sheet +0.08 C Max. H Nom. Min. Dist. Hole C/LTo Edge 4.37 4.35 4.8 6 4.37 4.35 4.8 6 4.37 4.35 4.8 6 7.37 7.35 7.9 7.2 7.92 7.9 8.7 8 8.74 8.72 9.5 8.8 METRIC All dimensions are in millimeters. Thread Size x Pitch Type Thread Code M2 x 0.4 F4 M2 M2.5 x 0.45 F4 M2.5 M3 x 0.5 F4 M3 M4 x 0.7 F4 M4 M5 x 0.8 F4 M5 M6 x 1 F4 M6 Shank Code 1 2 1 2 1 2 1 2 1 2 3 4 5 A (Shank) Max. 1.53 2.3 1.53 2.3 1.53 2.3 1.53 2.3 1.53 2.3 3.05 3.84 4.63 Threads: Internal, ASME B1.1, 2B / ASME B1.13M, 6H Material: Heat treated 400 series stainless steel Finish: Passivated and/or tested per ASTM A380 For use in: HRB 88 / HB 183 or less HRB - Hardness Rockwell “B” Scale. HB - Hardness Brinell. Sheet Thickness 1.53-2.3 2.32 Min. 1.53-2.3 2.32 Min. 1.53-2.3 2.32 Min. 1.53-2.3 2.32 Min. 1.53-2.3 2.32 Min. 3.18-3.94 3.96-4.72 4.75 Min. Part Number Designation F4–440–2 Type & Material Thread Size Code Length Code www.pemnet.com PEMSERT® Self-clinching Flush Fasteners Installs flush into stainless steel sheets INSTALLATION 1. Prepare properly sized round mounting hole in sheet. Do not perform any secondary operations such as deburring. 2. Place shank end of fastener into mounting hole (preferably the punch side) as shown in the drawing. 3. With installation punch and anvil surfaces parallel, apply only enough squeezing force to embed the hexagonal head flush into the sheet. The metal displaced by the head flows evenly and smoothly around the back-tapered shank of the fastener, securely locking it into place with high pullout resistance while at the same time, the embedded hexagonal head provides high torque resistance. PEMSERTER® Installation Tooling Thread Code Anvil Part Number 256/M2/M2.5 8006193 440/M3 975200040 632 975200041 832/M4 975200042 032/M5 975200043 0420/M6 975200044 PUNCH Punch Part Number 975200048 ANVIL Axial Max. Screw Test Sheet Material ThreadShank Tensile Tightening 300 Series Stainless Steel StrengthTorque (3) CodeCode Installation Pushout (2) (in. lbs.) (lbs.) (lbs.) (lbs.) 1 1301.50 7200 270 256 2 1 1652.50 7200 270 440 2 1 1903.50 7200 290 632 2 1 2305.25 9000 450 832 2 1 2807.50 9000 450 032 2 3 0420 41035 36 14000 1000 5 METRIC UNIFIED PERFORMANCE DATA(1) Axial Max. Screw Test Sheet Material ThreadShank Tensile Tightening 300 Series Stainless Steel StrengthTorque (3) CodeCode Installation Pushout (kN) (2) (N•m) (kN) (N) 1 0.570.16 32 1200 M2 2 1 0.680.23 32 1200 M2.5 2 1 0.850.36 32 1200 M3 2 1 10.58 40 2000 M4 2 1 1.30.88 40 2000 M5 2 3 M6 44.5 3.7 65 4500 5 (1) Installation values are for general reference only. Actual set up and installation should be performed using the visual indication method described in this literature. Other performance values reported are averages when all proper installation parameters and procedures are followed. Variations in mounting hole size, sheet material, and installation procedure may affect performance. Performance testing this product in your application is recommended. We will be happy to provide technical assistance and/or samples for this purpose. (2) Failure occurs in screw stripping using a 60 ksi screw and the shortest shank length fastener. (3) Torque values shown will produce a preload of 70% of axial tensile strength with nut factor “k” equal to .2. Threads may strip or head of the F nut may bend and/or fail if screw is over-torqued beyond these values or if actual k value is less than .2. See PEM Bulletin F for flush fasteners in other materials. Regulatory compliance information is available in Technical Support section of our website. © 2014 PennEngineering. F4-2 Specifications subject to change without notice. See our website for the most current version of this bulletin. Technical support e-mail: [email protected]
© Copyright 2026 Paperzz