Wave Pump Kit - Current-USA

www.current-usa.com
Quick Start Guide
Wave Pump Kit
Getting Started
THANK YOU
For Getting in the LOOP
For step-by-step video instructions, visit our
website at www.current-usa.com/videos
Before Installation & Overview
Follow all safety instructions and
warnings included with this product.
TM
Main On/Off
3
P/S
STREAM
2
1
SURGE
WAVE
Please visit www.current-usa.com for warranty information.
Ensure only to use 24V DC power supply plugged into a
GFCI approved outlet with drip loop installed.
Always disconnect from power for cleaning or service.
Never let pump run dry or out of water.
Keep out of reach of children.
Magnet assembly is powerful. Be cautious not to cause
injury to fingers.
eFlux wave pumps can produce powerful waves in both
surge and wave mode. Ensure your tank is designed for
wave pumps and ensure pumps are mounted low enough
not to push water out of the aquarium.
Do not install pump close to the sand bed where it can stir
or suck up debris.
eFlux wave pumps create a tremendous amount of water
flow. DO NOT install pump where the strong current can
harm corals or animals.
Follow all safety instructions and
warnings included with this product.
Safety Warnings and Guidelines
FEED
FREQ
FLOW
FREQ
FLOW
STREAM
Stream / Steady Flow Mode
Pump 3, Flow/Stream Mode Only
3
Wave / Pulse Mode
WAVE
Pump 2, Secondary Wave Pump
2
Surge Gy re Mode
SURGE
Pump 1, Primary Wave Pump
1
P/S
FEED
TM
Primary/Secondary Pump
FLOW
FREQ
FEED Mode
LOCK
LOCK
Increase / Decrease
Frequency
FREQ
Increase / Decrease
Flow Rate
FLOW
Wave Pump Installation
STEP 1
Choose a mounting location inside the aquarium
vertical wall for your pump. Clean location of any
dirt, algae or calcium deposits.
STEP 2
Cut 6" of included cable wrap and install around
inside pump cable by wrapping it around the cord.
STEP 3
Carefully separate magnet from pump by sliding
or turning magnet (don't pull). Place pump in tank
and attach using outer magnet. Swivel and adjust
pump to optimal position. Slide optional pump
prefilter over front of pump.
Lock/Unlock Key
Cable Wrap
Magnet
Attachment
Pump Prefilter
(optional)
FREQUENCY
Displays if the Frequency
(duration) is being shown
on the rate display
Rate Display
Displays FLOW
or FREQUENCY
Each LED = 10% FLOW or duration
PUMP
Displays which pump is in
programming mode.
LOCK Mode
LED ON = Locked
LED OFF = Unlocked
Main / Secondary Pump
LED ON = Secondary Pump
LED OFF = Primary Pump
FLOW
Displays if the Flow
(velocity) is being shown
on the rate display
Flow Mode
SRE = Stream/Steady
SUR = Surge/Gyre
PUL = Wave/Pulse
TIP: Cable wrap protects the pump cable from inverts that can damage
cord, pump prefilter protects the impeller from large debris & inverts.
LED Display & Manifold HUB Installation
STEP 4
Choose a clean, dry location to mount manifold
HUB and wave pump LED display. Screw mounting
clips for HUB and LED display into stand location.
Slide HUB and wave pump LED display into
mounting clips.
Step 5
Connect cables in the following order:
A
a. LED Display micro USB cable into Port#2
b. IR Sensor micro USB cable into Port#1
B
c. eFlux Wave Pump into P1 Pump Connection
C
d. 24V DC cable into P1 Power DC input
D
AC Power
GFCI Outlet
24VDC
Transformer
D
C
Before connecting cables, please review the
following specifications and connections:
Pump #3
Power DC Input
Pump #1
Power DC Input
Pump #1
Pump Connection
P3
P2
P1
P2
Pump Connections:
Pump #2
Power DC Input
Pump #3
Pump Connection
P3
Communication LED
Indicator Light
Pump #2
Pump Connection
Port#3
Port#1
Port#2
Port#4
MicroUSB Ports
P1 Pump#1:
Main/Primary Wave Pump
P2 Pump#2:
Secondary (Gyre) Wave Pump
P3 Pump#3:
Steady/Stream Wave Pump*
*Operates only in stream mode
Micro USB Ports:
Port#1= Communications
Port#2= LED Display ONLY
Port#3= Communications
Port#4= Communications
Max. Pump DC Inputs Voltage: 24V DC
Max. DC Input per Channel: 72w@24VDC
Max. DC Output per Channel: 60w@24VDC
Port#2
P1
Port#1
A
LCK P/S SRE SUR PUL FRE FLO
eFlux Wave Pump
LED Display
B
IR Sensor
STEP 6
Plug 24V DC transformer into GFCI outlet. Indicator
LED light will turn on. Use velcro wraps for cables.
STEP 7
Remove clear tab from remote. Press
main power key. Pump will turn on in
default setting Stream MODE, 100% flow.
Main
Power
TM
0
STREAM
SURGE
WAVE
2
1
P/S
FEED
FLOW
FREQ
FLOW
FREQ
TM
LOCK
Programming
Control
Instructions
Installation for&Orbit
Marine
PRO
STEP 8
Choose Flow Mode
Use caution when operating
pumps in wave or surge mode
STREAM/STEADY MODE
"
50%
0
SURGE/GYRE FLOW
TIME
100%
FLOW
ON
STEP 10
Program Flowrate and Flow Mode
OFF
0
WAVE/PULSE MODE
Press Pump#2 key
and press P/S key
P/S again to return Pump#2 to primary
(independent mode).
"
Max. Flow
Alternates a slow ramp up/down
Mimics surging water currents 50%
Flow adjustable from 0-100%,
frequency 10-90 seconds.
FREQUENCY
Max. FLOW
100%
ON
FLOW
Alternates a short pulsing action
Mimics wave type action. Flow
adjustable from 0-100%,
frequency 0.3 to 7 seconds.
FEED
GYRE - Press Pump#2 key
then press the
P/S key P/S to designate Pump#2 as a primary
or secondary pump. When Pump#2 is in
secondary mode it will run the opposite of
Pump#1 program (operating in tandem).
100%
Flow
Steady, constant flow stream
adjustable from 0-100%. Mimics
strong water currents, provides
excellent circulation tank wide.
FEED - Press the FEED key
to temporarily turn pumps off
for feeding. Pumps will return to normal setting after 10 min.
Press designated pump key
to
program specific pump. Pump # will light on
display.
!
50%
OFF
0
TIME
STEP 9
Main Pump Controls
"
#
Press designated mode key
to
choose flow mode. Flow mode will light
on display.
STREAM
SURGE
WAVE
POWER - Press the Main Power key
to LED display and
all pumps ON/OFF. To turn individual pumps ON/OFF, press
the designated pump key
and hold for 5 seconds.
Press flow keys
to change the flow
speed. 10% increment will light on display.
LOCK/UNLOCK - Press the LOCK key
to lock settings.LCK
will display on display. To unlock settings, press LOCK key
for 5 seconds. NOTE: Remote will ONLY work when unlocked.
Press frequency keys
to change the
frequency in SURGE or WAVE mode. Rate
of frequency will light on display.
!
"
#
LOCK
LOCK
FLOW
FLOW
FREQ
FREQ