www.current-usa.com Quick Start Guide Wave Pump Kit Getting Started THANK YOU For Getting in the LOOP For step-by-step video instructions, visit our website at www.current-usa.com/videos Before Installation & Overview Follow all safety instructions and warnings included with this product. TM Main On/Off 3 P/S STREAM 2 1 SURGE WAVE Please visit www.current-usa.com for warranty information. Ensure only to use 24V DC power supply plugged into a GFCI approved outlet with drip loop installed. Always disconnect from power for cleaning or service. Never let pump run dry or out of water. Keep out of reach of children. Magnet assembly is powerful. Be cautious not to cause injury to fingers. eFlux wave pumps can produce powerful waves in both surge and wave mode. Ensure your tank is designed for wave pumps and ensure pumps are mounted low enough not to push water out of the aquarium. Do not install pump close to the sand bed where it can stir or suck up debris. eFlux wave pumps create a tremendous amount of water flow. DO NOT install pump where the strong current can harm corals or animals. Follow all safety instructions and warnings included with this product. Safety Warnings and Guidelines FEED FREQ FLOW FREQ FLOW STREAM Stream / Steady Flow Mode Pump 3, Flow/Stream Mode Only 3 Wave / Pulse Mode WAVE Pump 2, Secondary Wave Pump 2 Surge Gy re Mode SURGE Pump 1, Primary Wave Pump 1 P/S FEED TM Primary/Secondary Pump FLOW FREQ FEED Mode LOCK LOCK Increase / Decrease Frequency FREQ Increase / Decrease Flow Rate FLOW Wave Pump Installation STEP 1 Choose a mounting location inside the aquarium vertical wall for your pump. Clean location of any dirt, algae or calcium deposits. STEP 2 Cut 6" of included cable wrap and install around inside pump cable by wrapping it around the cord. STEP 3 Carefully separate magnet from pump by sliding or turning magnet (don't pull). Place pump in tank and attach using outer magnet. Swivel and adjust pump to optimal position. Slide optional pump prefilter over front of pump. Lock/Unlock Key Cable Wrap Magnet Attachment Pump Prefilter (optional) FREQUENCY Displays if the Frequency (duration) is being shown on the rate display Rate Display Displays FLOW or FREQUENCY Each LED = 10% FLOW or duration PUMP Displays which pump is in programming mode. LOCK Mode LED ON = Locked LED OFF = Unlocked Main / Secondary Pump LED ON = Secondary Pump LED OFF = Primary Pump FLOW Displays if the Flow (velocity) is being shown on the rate display Flow Mode SRE = Stream/Steady SUR = Surge/Gyre PUL = Wave/Pulse TIP: Cable wrap protects the pump cable from inverts that can damage cord, pump prefilter protects the impeller from large debris & inverts. LED Display & Manifold HUB Installation STEP 4 Choose a clean, dry location to mount manifold HUB and wave pump LED display. Screw mounting clips for HUB and LED display into stand location. Slide HUB and wave pump LED display into mounting clips. Step 5 Connect cables in the following order: A a. LED Display micro USB cable into Port#2 b. IR Sensor micro USB cable into Port#1 B c. eFlux Wave Pump into P1 Pump Connection C d. 24V DC cable into P1 Power DC input D AC Power GFCI Outlet 24VDC Transformer D C Before connecting cables, please review the following specifications and connections: Pump #3 Power DC Input Pump #1 Power DC Input Pump #1 Pump Connection P3 P2 P1 P2 Pump Connections: Pump #2 Power DC Input Pump #3 Pump Connection P3 Communication LED Indicator Light Pump #2 Pump Connection Port#3 Port#1 Port#2 Port#4 MicroUSB Ports P1 Pump#1: Main/Primary Wave Pump P2 Pump#2: Secondary (Gyre) Wave Pump P3 Pump#3: Steady/Stream Wave Pump* *Operates only in stream mode Micro USB Ports: Port#1= Communications Port#2= LED Display ONLY Port#3= Communications Port#4= Communications Max. Pump DC Inputs Voltage: 24V DC Max. DC Input per Channel: 72w@24VDC Max. DC Output per Channel: 60w@24VDC Port#2 P1 Port#1 A LCK P/S SRE SUR PUL FRE FLO eFlux Wave Pump LED Display B IR Sensor STEP 6 Plug 24V DC transformer into GFCI outlet. Indicator LED light will turn on. Use velcro wraps for cables. STEP 7 Remove clear tab from remote. Press main power key. Pump will turn on in default setting Stream MODE, 100% flow. Main Power TM 0 STREAM SURGE WAVE 2 1 P/S FEED FLOW FREQ FLOW FREQ TM LOCK Programming Control Instructions Installation for&Orbit Marine PRO STEP 8 Choose Flow Mode Use caution when operating pumps in wave or surge mode STREAM/STEADY MODE " 50% 0 SURGE/GYRE FLOW TIME 100% FLOW ON STEP 10 Program Flowrate and Flow Mode OFF 0 WAVE/PULSE MODE Press Pump#2 key and press P/S key P/S again to return Pump#2 to primary (independent mode). " Max. Flow Alternates a slow ramp up/down Mimics surging water currents 50% Flow adjustable from 0-100%, frequency 10-90 seconds. FREQUENCY Max. FLOW 100% ON FLOW Alternates a short pulsing action Mimics wave type action. Flow adjustable from 0-100%, frequency 0.3 to 7 seconds. FEED GYRE - Press Pump#2 key then press the P/S key P/S to designate Pump#2 as a primary or secondary pump. When Pump#2 is in secondary mode it will run the opposite of Pump#1 program (operating in tandem). 100% Flow Steady, constant flow stream adjustable from 0-100%. Mimics strong water currents, provides excellent circulation tank wide. FEED - Press the FEED key to temporarily turn pumps off for feeding. Pumps will return to normal setting after 10 min. Press designated pump key to program specific pump. Pump # will light on display. ! 50% OFF 0 TIME STEP 9 Main Pump Controls " # Press designated mode key to choose flow mode. Flow mode will light on display. STREAM SURGE WAVE POWER - Press the Main Power key to LED display and all pumps ON/OFF. To turn individual pumps ON/OFF, press the designated pump key and hold for 5 seconds. Press flow keys to change the flow speed. 10% increment will light on display. LOCK/UNLOCK - Press the LOCK key to lock settings.LCK will display on display. To unlock settings, press LOCK key for 5 seconds. NOTE: Remote will ONLY work when unlocked. Press frequency keys to change the frequency in SURGE or WAVE mode. Rate of frequency will light on display. ! " # LOCK LOCK FLOW FLOW FREQ FREQ
© Copyright 2026 Paperzz