pdf Inquiry Guide Heated Hoses

Heated Hoses
Customer:
Thermocoax Isopad GmbH
Address:
Department Inside Sales
Englerstrasse 11
69126 Heidelberg
Germany
Country:
Tel.:
Fax:
E-mail:
+49 (0) 6221 - 3043 - 950
+49 (0) 6221 - 3043 - 981
[email protected]
The purpose of this questionnaire is to make it
easier for our engineers to prepare a quotation.
Please complete it carefully and send it to us - we
will then contact you immediately.
Bold letters: Required information
(no quotation can be made without this information)
Italics: Standard values
(to be used if no value is selected)
Contact person:
Telephone:
Fax:
E-mail:
Project-related data and description of application
Project name:
required quantity:
Please supply a drawing or sketch along with this questionnaire!
Operating location and classification of electrical operating resources:
Indoors
Protection class I
Outdoors
or Protection class II
Pharm. / food industry
Ingress protection class: IP
Zone classification
Ordinary
Hazardous
Zone:
Temperature class:
Gas group:
Temperatures
Minimum ambient temperature (°C):
Operating temperature (°C):
Maximum permissible product temperature (°C):
max. temp. occurring (°C)
(e.g. ambient, process, steam cleaning etc.)
There should be a temperature difference of at least 20 K between the
operating and the maximum permissible product temperatures!
TXI Inquiry Guide EN 150707.xlsx
Page 1 / 3
Heated hoses
<Questionnaire Contd.>
Specifications of the heated material / medium:
Density (kg/ dm³):
Designation of material/medium:
Liquid
Aggregate state:
Gaseous
Additional info about the medium:
Heated hose specification
Length of hose (m):
Nominal width (mm):
max. operating pressure incl. peak pressures (bar abs.):
Hose design:
PTFE plain hose
VA corrugated hose
PTFE corrugated hose
other material
Replaceable core
Yes
Inlet fitting (A):
Material:
Outlet fitting (B):
Material:
External protection:
PA braid
VA braid
End cap:
Flexible plastic
Corrugated hose
Other
Special design as described in the attached drawing
Temperature control
Temperature sensor
Pt 100 2-wire
NiCr-Ni, Type K
TXI Inquiry Guide EN 150707.xlsx
Special sensor
desired sensor position ( X in mm ):
Pt100 3-wire
Controller
Fe-CuNi, Type J
Type:
Wall mounted
No
DIN rail mounting
Recommended by TXI:
Front panel installation
Page 2 / 3
Heated hoses
<Questionnaire Contd.>
Power supply
Power required (W):
Mains supply:
Operating voltage (V):
1 AC
3 AC Y
3 AC 
AC
DC
Frequency (Hz):
or TXI recommendation
Plug for power lead:
No
Yes - Type:
● 1-phase (240V max.)
● For operating voltages >50V, power supply must always have a grounding conductor!
Power cable and sensor cable channel:
separate:
Mains connection (length):
Power / sensor cable with connector
No
common:
m
Sensor connection (length):
Yes
Type:
m
(Please indicate connector assignments)
Integrated control cables
Yes *
No
* If you require integrated control lines, please state the related specifications.
(e.g. number of wires, wire colors, connector assignments etc.)
Specification of the general hose dimensions is subject to DIN 20066.
Heated hoses with pressurization are subject to pressure equipment guideline 97/23/EG.
So that heated hoses can be correctly dimensioned for warranty purposes, details of the medium and aggregate state are
required.
For the purpose of hose capacity and service life, it would also be helpful to indicate the installation location and possible
dynamic requirements occurring on the hose line.
Important note:
All manufacturers, importers, retailers and operators are required to comply with the Equipment and Product Safety Act, and
the corresponding European product guidelines.
To enable us to evaluate the technical safety of a product suitable for your application, we need the completed questionnaire in
order to have our engineers draft a suitable proposal. We therefore ask you to complete the questionnaire as carefully as
possible and return it to us - we will then contact you immediately.
Date
TXI Inquiry Guide EN 150707.xlsx
Completed by
Page 3 / 3