Project Focus < < < < Milan - Italy - 2009 Plant Type: Hydronic system Total cooling capacity: 2800 kW Total heating capacity: 2400 kW < Installed appliances: 4x ERACS-Q 2722, MANAGER 3000, DEMETRA < Designer: Planning - Ingegneria Impiantistica Comfort in & out Aporti Palace in Milan thanks to Climaveneta Integra Units. Historic seat of Royal Post, Aporti Palace has now become a new office building designed for offices and commercial uses Officially reborn in the heart of Milano the new Aporti Palace, former seat of the Italian Post Office, designed back in the thirties by Ulisse Stacchini, the same architect of the Central Station. The project, coordinated by architects Antonio Citterio and Patricia Viel & Partners, provided a high quality standard in the structure and above all for what concerns the plant design. In order to increase the energy efficiency of the building and reset CO2 and pollutants emissions in the heart of the city, Engineer Marazzi by Planning Engineering has adopted four multi-purpose heat pump Integra units, ERACS-Q by Climaveneta. The main effort was to demonstrate to the client the advantages of Climaveneta solution based exclusively on multi-purpose units, compared to a traditional central cooling and boiler one. To this propose Climaveneta carried out an energy analysis on the building allowing to dispose of the basic data for correct simulation of thermal loads. The annual thermal demand of the building was estimated at about 3,835,160 kWh/ year, while cooling at about 1,925,850 kWh/ year. The power absorption of the proposed unit, calculated taking into account the real capacity of the multi-purpose unit to produce for free a portion of energy required is about 1,082,520 kWh. Accepting the rough calculation of the annual efficiency average as the ratio of total energy output and energy consumption, we get a TER of 5:32, a value absolutely unreachable by any other conventional air source chiller. In case in the same building should be instead provided the solution Project Focus with standard chiller and boiler, to meet the request of air conditioning in summer and winter given above, primary energy consumption would amount at 3,913,430 h kW/ year (high-performance boiler, medium = 0.98) + 1,413,990 h kW/ year (high-efficiency chillers, medium EER = 3.00). It is so easy to calculate that Climaveneta Integra units only consume 2,384,400 kWhper year, saving in primary energy consumption by more than 55%. In addition to the drastic reduction of running costs, the choice of multipurpose units instead of chiller plus boiler solution brings other significant benefits such as reduction of technical space to be allocated, having to place one unit instead of two, plant simplifying because exchangers provide water connections and does not require any special reverse side of 'cold' and 'hot' hydraulic circuits or any auxiliary disposal. Are also not required neither the supply line of fuel for the boiler or even the supply and installation of the chimney and procedures for compliance with regulations. Operation on site are reduced and simplified because the units require only connection to electrical supply; in addition maintenance is also on a single machine. As multi-purpose unit is self-adaptable to the needs of the plant, it is not expected summer / winter switching and unit will ensure the simultaneous and independent hot and cold water circuits intended for. The coefficient of effect twice higher than that of a traditional electric chiller without recovery and there are no direct CO2 emissions: the units are electrically powered, so there are no exhaust fumes into the atmosphere at installation and finally also in active recovery mode, unit can grant maximum efficiency and respect for the environment. Within the Climaveneta Integra range the planner selected 4 ERACS / Q 2722 / LT / SL units. The plant total cooling capacity is 2,800kW and heating capacity is 2,400 kW. The units have been selected in SL version to ensure the minimum noise level. In particular, the size selected shows a sound pressure level of 58 dB (A) at 10 m. To ensure the functioning of the units installed on the roof, even in extreme operation conditions, it has also been designed a special version able to ensure the full load operation down to -10 ° C of external air temperature. To ensure high standards of reliability and comfort throughout the year the two compressors are actually working on two independent cooling circuits and each circuit works with a semi-hermetic screw compressor using R134a refrigerant. In the event of a failure of one of the two, the other is then able to cover at least 50% of demand, avoiding the total loss of service and ensuring the end user maximum system reliability. The choice of refrigerant R134a, which meet the standards of ecosustainability imposed by the European Community with an index ODP "ozone depletion Protection" of 0, has been driven by the fact that this Refrigerant does not have any negative impact to the atmosphere, even in case of accidental spillage in the room or during unit disposal. The plant side shell and tube exchangers, designed by Climaveneta, are optimized to ensure maximum efficiency of heat exchange process. Providing asymmetric steps of refrigerant, heat transfer coefficient obtained has been maximized and the unit works between the optimal pressure levels, ensuring a more efficient refrigeration cycle, then lower energy absorption and therefore lower running costs. INTEGRA multipurpose units by Climaveneta overcome the traditional chiller and boiler system, ensuring perfect comfort all year round, without CO2 emissions in the atmosphere and reducing running costs by more than 55%.
© Copyright 2026 Paperzz