Package Information EH-PB Introduction EH-PB is a Profibus-DP gateway that allows Hitachi EH-150 or MICRO-EH PLCs to be connected as a slave in a Profibus-DP network. The EH-PB is designed for the connection to the RS422 port of the EH150 PLC (port 1) and the MICRO-EH PLC (port 2). Physical Interface Profibus connector The fieldbus interface is optically separated from the other electronics. The fieldbus interface of the EHPB is a 9-pin female D-SUB connector. Please refer to the table below for the pin layout. Standard D-SUB 9 contact female Pin Housing 1 2 3 4 5 6 7 8 9 e-Mail: [email protected] Name Shield B-line RTS GND BUS + 5V OUT A-line Description Connected to PE No connection No connection Positive Rx/Tx Request to Send Isolated GND Isolated + 5V No connection Negative Rx/Tx No connection Hitachi Europe GmbH Am Seestern 18 D-40547 Düsseldorf Tel.: 02 11 / 52 83 -0 Fax: 02 11 / 52 83 -649 EH-PB RS422 connector The serial connector of the EH-PB can be connected to port1 of a EH-150 PLC or to port 2 of a MICROEH PLC. Please refer to the table below for the pin layout Standard RJ45 Pin 1 2 3 4 5 6 7 8 Name + 5V IN A+ AGND B+ BGND Not conn. Description Voltage supply for gateway Positive TX (RS422) Negative TX (RS422) Ground Positive RX (RS422) Negative RX (RS422) Ground Cable diagrams for the connecting to a EH-150 PLC and to a MICRO-EH PLC +5V EH-PB EH-150 Port 1 1 +5V IN 1 SG 2 A+ 2 CD 3 A- 3 ER1 4 GND 4 TX 5 B+ 5 TXN 6 B- 6 RXN 7 GND 7RX 8 8 RS +0V EH-150 settings for port 1: RS422 WRF037: 16#A1xx, xx = station number 2 EH-PB +5V EH-PB MICRO-EH Port 2 1 +5V IN 1 NC 2 A+ 2 NC 3 A- 3 NC 4 GND 4 NC 5 B+ 5 VCC 5V OUT 6 B- 6 RSN 7 GND 7 SG 8 8 CSP +0V 9 RT 10 RDN 11 RDP 12 SDN 13 SDP 14 RSP 15 CSN MICRO-EH settings for port 2 RS422 WRF03D: 16#A2xx, xx = station number 3 EH-PB EH-PB configuration Note address Two rotary switches are available to configure the node address in the Profibus-DP network. They are accessible by opening the enclosure as shown in the figure below. The address must be set for two different purposes: - Profibus node addressing (allowable addresses are 1-99 – hexadecimal format) Selection for Gateway configuration mode in order to upgrade the firmeware (address 00) 4 EH-PB Adding GSD file The first step is to add the description file (EHBP0692.GSD) to the library of the Profibus-DP master programming tool. Please open in the Sycon configuration software the window File -> Copy GSD and select the dedicated GSD file. Adding slave device Next step is to insert the slave module. Therefore pick the device from the “slave library” and connect it (drag & drop) to the Profibus line. 5 EH-PB Profibus-DP network including a EH-RMP as Profibus-DP master and a EH-PB as Profibus-DP slave 6 EH-PB Slave configuration Double click with the left mouse button on the device in the network topology to open the configuration window. From this window you can configure the In-and Output data for the communication as well as the communication speed between the EH-PB and the Hitachi PLC (EH-150, MICRO-EH). 7 EH-PB Baudrate To set the baudrate please click on the “Parameter Data” button and afterwards on the “Common” button. The following window will appear. The baudrate can be changed by double clicking on the baudrate. Possible values are Default (0), 4800 (1), 9600 (2) and 19200 (3) 8 EH-PB In-Output data You can select three different tasks 4 Word Input: reads 4 words from Hitachi PLCs 4 Word Output: writes 4 words to Hitachi PLCs Status Word: reports the status information (one word) of the EH-PB; if no error in the read or write task is reported the first byte is 00hex and the second byte shows the speed code selection. If there is an error in the communication with the Hitachi PLC, the first byte shows the address of the PLC, and the second byte the error type (1=read, 2=write). Maximum number of tasks are 9. Input data Click on the “Module” button and select “4 Word Input” and press the OK button. In the subwindow, “PLC address / First Register address”, can be set. In the example, 4 words will be read from the Hitachi PLC with station number = 1, starting from WM0 to WM3. 9 EH-PB “PLC address” range value is: 1 .. 255; “First register address” range value is: 0 .. 1023; Output data Click on the “Module” button and select “4 Word Output” and press the OK button. In the subwindow, “PLC address / First Register address”, can be set. In the example 4 words will be written to the Hitachi PLC with station number = 1, starting from WMA to WMD. “PLC address” range value is: 1 .. 255; “First register address” range value is: 0 .. 1023; 10 EH-PB Status word Reports the status information (one word) of the EH-PB; if no error in the read or write task is reported the first byte is 00hex and the second byte shows the speed code selection. If there is an error in the communication with the Hitachi PLC, the first byte shows the address of the PLC, and the second byte the error type (1=read, 2=write). 11
© Copyright 2026 Paperzz