INFORMATIONAL NOTES READ THESE NOTES BEFORE USING THESE STANDARDS. USE THESE STANDARDS FOR OVERHEAD SIGN STRUCTURES SUBJECT TO LIMITATIONS AS SHOWN. USE THESE STANDARDS AS A BASIS FOR THE PREPARATION OF STRUCTURE LAYOUTS AND CONTRACT DRAWINGS. REFERENCE TO THESE STANDARDS ON OVERHEAD SIGN STRUCTURES PLANS IS PROHIBITED. THE DESIGNER MUST PROVIDE THE INFORMATION OBTAINED FROM THE DESIGN TABLES ON THE CONTRACT DRAWINGS. THE DESIGNER MUST PROVIDE THE SIGN AREA, STRUCTURE HEIGHT, AND SIGN LOCATION USED TO OBTAIN MEMBER SIZES FROM THE DESIGN TABLES ON THE CONTRACT DRAWINGS. DESIGN COMPUTATIONS ARE REQUIRED FOR ANY PORTION OF A STRUCTURE FOR WHICH THE INFORMATION IS NOT TAKEN DIRECTLY FROM THE DESIGN TABLES CONTAINED IN THESE STANDARDS. DO NOT VIOLATE CRITERIA USED FOR THE DEVELOPMENT OF THESE DESIGN TABLES. ALL SIGN SUPPORTS LOCATED WITHIN THE CLEAR ZONE MUST BE SHIELDED WITH A CRASHWORTHY BARRIER, SEE TABLE A, BC-745M, SHEET 2. AVOID BRIDGE-MOUNTED SIGN STRUCTURES WHENEVER POSSIBLE. IF AVOIDANCE IS NOT POSSIBLE, THE STRUCTURE SHOULD BE LOCATED AS CLOSE TO A PIER SUPPORT AS IS PRACTICAL. THE AFFECTED BRIDGE COMPONENTS SHALL BE DESIGNED TO CARRY THE ADDITIONAL LOADS DUE TO THE WEIGHT OF THE SIGN STRUCTURE AND THE LOADINGS APPLIED TO SIGN STRUCTURE. IF A BARRIER IS USED OR IS REQUIRED, THE SIGN STRUCTURE SHALL BE LOCATED JUST BEYOND THE DESIGN DEFLECTION DISTANCE OF THE BARRIER. INFORMATION CONTAINED IN THE DESIGN TABLES DESIGN TABLES INCLUDED IN THIS STANDARD WERE DEVELOPED USING A COMPUTER PROGRAM AND ARE BASED ON THE DESIGN CRITERIA SHOWN ON THIS SHEET. THE MEMBER SIZES INDICATED IN THE DESIGN TABLES MEET THE FATIGUE REQUIREMENTS FOR FATIGUE CATEGORY II. THE DESIGNER MUST CHECK THE ADEQUACY OF THE MEMBER SIZES INDICATED WHEN THE FATIGUE CATEGORY IS SPECIFIED TO BE I FOR THE PROJECT. DESIGN CRITERIA FOR PENNDOT SIGN STRUCTURES DEAD LOADS CONSTRUCTION GENERAL NOTES MATERIALS AND WORKMANSHIP: PENNDOT STD. DWGS. (U.N.O.)* SIGN PANELS LIGHT FIXTURES SIGN SUPPORT BEAM COLUMNS, CHORDS CATWALK PROVIDE MATERIALS AND WORKMANSHIP IN ACCORDANCE WITH THE CURRENT VERSIONS OF THE PENNSYLVANIA DEPARTMENT OF TRANSPORTATION PUBLICATION 408, ANSI/AWS WELDING CODE D1.5, CONTRACT SPECIAL PROVISIONS, AND AASHTO "STANDARD SPECIFICATIONS FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS". USE ANSI/AWS D1.1 FOR WELDING NOT COVERED IN ANSI/AASHTO/AWS D1.5. TC-8701E OR TC-8701S BC-745M, SHT. 10 BC-745M, SHT. 8 CALCULATED INTERNALLY WITHIN PROGRAM BC-745M, SHT. 8 & 9 DYNAMIC\VARIABLE MESSAGE SIGN (DMS\VMS) STRUCTURES PROVIDE STRUCTURAL STEEL CONFORMING TO THE FOLLOWING: 4-POST 4-CHORD STRUCTURE TYPES AS PRESENTED IN THESE STANDARDS ARE RECOMMENDED TO CARRY DYNAMIC\VARIABLE MESSAGE SIGNS (DMS\VMS). THE CHIEF BRIDGE ENGINEER MUST REVIEW AND APPROVE ALL STRUCTURES DESIGNED TO CARRY A DYNAMIC\VARIABLE MESSAGE SIGN (DMS\VMS). PIPE COLUMNS, PIPE CHORDS, & PIPE BRACING: ASTM A53, GR. B, TYPE E OR S, Fy=35 ksi. PIPE COLUMNS: EXTERNAL LOADS ICE LOAD WIND LOAD CATWALK AASHTO SIGN SPECS. (U.N.O.) ANGLES, SHAPES, AND PLATES: AASHTO M270, GRADE 36 ASTM A709, GRADE 36 3.7 APPENDIX C, SECTION C.3, EQ. C-1, WITH 80 MPH WIND AND 30% GUST FACTOR 1994 SIGN SPEC. COMMENTARY 1.2.2 GROUP LOADS ALTERNATE PRESS-BREAK MEMBERS: ALTERNATE PRESS-BREAK MEMBERS MUST HAVE THE EQUIVALENT STRENGTH OF THE MEMBER THEY ARE REPLACING. EQUIVALENT RADIUS FOR PRESS-BREAK MEMBERS IS MEASURED FROM THE CENTER OF THE MEMBER TO THE MID-POINT OF ANY CHORD OF THE MEMBER. MINIMUM THICKNESS OF PRESS-BREAK MEMBERS TO BE ". PENNDOT’S SIGN STRUCTURE PROGRAM OR AN APPROVED FINITE ELEMENT ANALYSIS COMPUTER PROGRAM MUST BE RUN TO VERIFY THE ADEQUACY OF PRESS-BREAK MEMBER FOR STRENGTH AND FATIGUE. PRESS-BREAK MEMBERS ARE PERMITTED AS AN ALTERNATE ONLY FOR COLUMNS. PRESS-BREAK MEMBERS ARE NOT PERMITTED FOR CHORDS. AASHTO SIGN SPECS. 3.4 STEEL CRITERIA AASHTO SIGN SPECS. (U.N.O.) SECTION PROPERTIES FOR TUBULAR SHAPES MAXIMUM STRESSES IN TUBULAR SHAPES ALLOWABLE STRESSES FOR TUBULAR SHAPES ALLOWABLE STRESSES FOR SIGN SUPPORTS ALLOWABLE STRESSES FOR BASE PLATES 24 INCH DIAMETER AND GREATER, API 5L, GR. B, PSL2 IS PERMITTED, 65 KSI YIELD MAX. APPENDIX B, TABLE B-1 APPENDIX B, TABLE B-2 5.6 (TABLE 5-3) & 5.11 5.12 5.8 PROVIDE BOLTS CONFORMING TO THE FOLLOWING: ANCHOR BOLTS: ASTM, F1554 GRADE 55 PER PUBLICATION 408 SECTION 1105.02(c)3. ALLOWABLE STRESSES FOR COMBINED STEEL STRESS 5.12 FATIGUE REQUIREMENTS (FATIGUE CATEGORY II ) SECTION 11 ALLOWABLE DEFLECTION 10.4 PERMANENT CAMBER 10.5 ALLOWABLE STRESSES FOR STRUCTURAL STEEL SECTION 5 BOLTS: ASTM A-325 H.S. BOLTS EXCEPT AS NOTED DESIGN SPECIFICATIONS: THE SPAN RANGE INCLUDED IN THIS STANDARD ARE AS FOLLOWS: BOLT CRITERIA BD-645M: FOUR-POST FOUR-CHORD TRUSS, SPANS FROM 100’ TO 200’. THE DESIGN TABLES INCLUDE MEMBER SIZES FOR THE STRUCTURES FOR VARIOUS COMBINATIONS OF COLUMN HEIGHT, SPAN LENGTH, AND SIGN AREA. THEY ALSO INCLUDE SPREAD FOOTING DESIGNS. THE CORRESPONDING FABRICATION AND CONSTRUCTION DETAILS ARE CONTAINED ON STANDARD DRAWING BC-745M. CONCRETE CRITERIA AASHTO "STANDARD SPECIFICATIONS FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS", 2001 WITH CURRENT INTERIMS (UNLESS NOTED OTHERWISE); AASHTO "STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES, 1996 WITH INTERIMS THROUGH AND INCLUDING 2000; PENNDOT DESIGN MANUAL - PART 4, AUGUST 1993 EDITION (INCLUDING AUGUST 1995 REVISIONS) AASHTO HIGHWAY BRIDGES (U.N.O.) ALLOWABLE BOLT STRESSES SLIP-CRITICAL BOLT ALLOWABLE BOLT PRYING ACTION COMBINED BOLT SHEAR AND TENSION BOLT DESIGN CRITERIA ALLOWABLE ANCHOR BOLT STRESSES TABLE 10.32.3B 10.32.3.2.1 10.32.3.3.2 10.32.3.3.3 AASHTO SIGN SPECS. 5.16 AASHTO SIGN SPECS. 5.17 ALL FILLET WELDS SHOWN ARE MINIMUM SIZE UNLESS NOTED OTHERWISE. AASHTO HIGHWAY BRIDGES (U.N.O.) NOTES TO DESIGNER GENERAL NOTES 1. PROVIDE 2-INCH CONCRETE COVER ON REINFORCEMENT BARS, EXCEPT AS NOTED. 2. USE CLASS A CEMENT CONCRETE f’c = 3000 PSI IN PEDESTALS, FOOTINGS AND CAISSONS. 3. PROVIDE GRADE 60 REINFORCING STEEL BARS THAT MEET THE REQUIREMENTS OF ASTM A615 FOR CONCRETE REINFORCEMENT. DO NOT WELD REINFORCING STEEL BARS. 4. RAKE-FINISH ALL HORIZONTAL CONSTRUCTION JOINTS, EXCEPT AS INDICATED. 5. VERIFY ALL DIMENSIONS AND GEOMETRY OF THE EXISTING STRUCTURES IN THE FIELD AS NECESSARY FOR PROPER FIT OF THE PROPOSED CONSTRUCTION. ALLOWABLE BEARING STRESS 8.15.2.1.3 REINFORCEMENT TENSILE STRESS 8.15.2.2 SHEAR CAPACITY OF FOOTINGS 8.15.5.6.1 SHEAR STRESS IN FOOTINGS 8.15.5.6.2 ALLOWABLE SHEAR STRESS 8.15.5.6.4 SLENDERNESS OF COLUMNS 8.16.5.2 MINIMUM REINF. OF FLEXURAL MEMBERS 8.17.1 SPACING LIMITS FOR REINFORCEMENT 8.21 MINIMUM CONCRETE COVER DM-4 D8.22.1* PRESSURES FOR ECCENTRICALLY LOADED FOOTINGS FIG. 4.4.7.1.1.1C DISTRIBUTION OF REINFORCEMENT 4.4.11.2.2 FOOTING STABILITY REQUIREMENTS DM-4 D5.5.5 TORSION ACI SECTION A.7.3* COLUMN DESIGN (PEDESTALS) 8.15.4 PLACE THE FOLLOWING NOTE ON CONTRACT DRAWINGS - "PROVIDE MATERIALS AND WORKMANSHIP IN ACCORDANCE WITH SPECIFICATIONS, PUBLICATION 408 - (INDICATE CHANGE NUMBER), ANSI/AASHTO/AWS D1.5 BRIDGE WELDING CODE AND CONTRACT SPECIAL PROVISIONS. USE ANSI/AWS D1.1 FOR WELDING NOT COVERED IN ANSI/AASHTO/AWS D1.5". 4-POST 4-CHORD STRUCTURE TYPES AS PRESENTED IN THESE STANDARDS ARE RECOMMENDED TO CARRY DYNAMIC\VARIABLE MESSAGE SIGNS (DMS\VMS). OVERHEAD SIGN STRUCTURES INTENDED TO CARRY DYNAMIC\VARIABLE MESSAGE SIGNS (DMS\VMS) MUST BE DESIGNED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF PENNSYLVANIA AND SUBMITTED TO THE CHIEF BRIDGE ENGINEER FOR REVIEW AND APPROVAL. THESE STANDARDS MAY BE USED FOR PRELIMINARY MEMBER SIZES ONLY; DESIGN COMPUTATION MUST BE SUBMITTED FOR ALL COMPONENTS OF OVERHEAD SIGN STRUCTURES CARRYING DYNAMIC\VARIABLE MESSAGE SIGNS (DMS\VMS). 6. CHAMFER EXPOSED CONCRETE EDGES 1 INCH BY 1 INCH. SPREAD FOOTINGS 7. ALL DIMENSIONS SHOWN ARE HORIZONTAL, EXCEPT AS NOTED. 8. DIMENSIONS ARE BASED ON A NORMAL TEMPERATURE OF 68 DEGREES F. 9. SPREAD FOOTINGS MAY BE ORDERED BY THE ENGINEER TO BE AT ANY ELEVATION OR OF ANY DIMENSIONS NECESSARY TO PROVIDE A PROPER FOUNDATION. 10. GALVANIZE ALL STRUCTURAL STEEL, BOLTS, NUTS AND WASHERS IN ACCORDANCE WITH PUB. 408 UNLESS STAINLESS STEEL OR OTHERWISE INDICATED. 11. PIPE DIAMETERS SHOWN UP TO AND INCLUDING 12 INCHES ARE NOMINAL DIAMETERS. PIPE DIAMETERS SHOWN FROM 14 INCHES AND UP ARE ACTUAL DIAMETERS. MAXIMUM DESIGN PRESSURE MINIMUM AREA IN BEARING UNIT WEIGHT OF SOIL 1.5 TONS PER SQUARE FOOT 95% 100 POUNDS PER CUBIC FOOT * LEGEND: DRILLED SHAFTS (CAISSONS) DM-4 SEC. D10.8.3.8, PENNDOT COM624P COMPUTER PROGRAM MAXIMUM DESIGN PRESSURE 1.5 TONS PER SQUARE FOOT MAXIMUM DESIGN LATERAL DISPLACEMENT 0.5" MODULUS OF SUBGRADE REACTION 10.0 POUNDS PER CUBIC INCH UNIT WEIGHT OF SOIL 100 POUNDS PER CUBIC FOOT ANGLE OF INTERNAL FRICTION 25? COHESION 0 KIPS PER SQUARE FOOT AASHTO SIGN SPEC: AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS, "STANDARD SPECIFICATIONS FOR STRUCTURAL SUPPORTS FOR HIGHWAY SIGNS, LUMINAIRES AND TRAFFIC SIGNALS" AASHTO HIGHWAY BRIDGES: AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS, "STANDARD SPECIFICATIONS FOR HIGHWAY BRIDGES" DM-4: 12. PROVIDE BOLT HOLES " LARGER THAN BOLT DIAMETER. SEISMIC DESIGN CRITERIA 13. PROVIDE ANCHOR BOLT HOLES " LARGER THAN BOLT DIAMETER. STRUCTURES ARE DESIGNED FOR A SEISMIC ACCELERATION COEFFICIENT = 0.15 14. PROVIDE A MINIMUM ANCHOR BOLT EMBEDMENT LENGTH OF 20 ANCHOR BOLT DIAMETERS. U.N.O.: UNLESS NOTED OTHERWISE ACI: 15. PROVIDE DOUBLE NUTS AND WASHER FOR EACH ANCHOR BOLT. AMERICAN CONCRETE INSTITUTE - BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE WITH COMMENTARY (ACI 318-99). CVN: 16. STEEL MEMBER COMPONENTS REQUIRING CHARPY V-NOTCH TESTING ARE DESIGNATED ON THE PLANS BY (CVN), PROVIDE STEEL CONFORMING TO THE CVN REQUIREMENTS FOR ZONE 2, NON FRACTURE CRITICAL AS GIVEN IN THE AASHTO MATERIAL SPECIFICATIONS. PENNSYLVANIA DEPARTMENT OF TRANSPORTATION, DESIGN MANUAL PART 4, STRUCTURES CHARPY V-NOTCH. 17. PROVIDE NON-SHRINK GROUT WITH ONE DAY MINIMUM COMPRESSIVE STRENGTH EQUAL TO OR GREATER THAN 3750 PSI. COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION TC-8700C SPACING CHARTS/DIRECT APPLIED LETTERS, NUMERALS, & ARROWS TC-8701D SIGN DETAILS/FREEWAY AND EXPRESSWAY GUIDE SIGNS TC-8701E EXTRUDED ALUMINUM CHANNEL SIGN TC-8701S FLAT SHEET ALUMINUM SIGNS WITH EXTRUDED ALUMINUM STIFFENERS TC-8715 SIGN LIGHTING/MERCURY VAPOR LAMPS TC-8716 ERECTION DETAILS/EXTRUDED ALUMINUM CHANNEL SIGNS FLAT SHEET ALUMINUM WITH STIFFENERS/OVERHEAD STRUCTURES BC-736M REINFORCEMENT BAR FABRICATION DETAILS BC-745M OVERHEAD SIGN STRUCTURES RC-11M CLASSIFICATION OF EARTHWORK FOR STRUCTURES RC-52M TYPE 2 STRONG POST GUIDE RAIL RC-53M TYPE 2 WEAK POST GUIDE RAIL RC-54M BARRIER PLACEMENT AT OBSTRUCTIONS RC-58M SINGLE FACE CONCRETE BARRIER PLACEMENT AT MEDIAN PIERS REFERENCE DRAWINGS BUREAU OF PROJECT DELIVERY OVERHEAD SIGN STRUCTURES 4 POST 4 CHORD TRUSS SPANS FROM 100’ TO 200’ NOTES AND DESIGN CRITERIA RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHT. 1 OF 7 BD-645M HOW TO USE THE DESIGN TABLES SETTING SUBSTRUCTURE ELEVATIONS SET THE TOP OF THE PEDESTAL OR CAISSON ELEVATION SO THAT THE BOTTOM OF BASE PLATE ELEVATION IS APPROXIMATELY 6 INCHES ABOVE THE HIGHEST SURROUNDING FINISHED GRADE ELEVATION. EXAMPLE TO SHOW PROCEDURE FOR SELECTING SET THE STRUCTURE TO AN ELEVATION THAT PLACES THE CENTER OF THE STRUCTURE AT THE MID-HEIGHT OF THE DEEPEST SIGN OR A MAXIMUM OF 9’-3" ABOVE THE BOTTOM OF THE SIGN PANEL. (SIGN HEIGHT INCLUDES "EXIT PANEL" SIGN IF PRESENT.) SIGN AREA, SPAN LENGTH, & POST HEIGHT 114’ SET THE STRUCTURE, SIGN PANELS, AND LUMINAIRES TO AN ELEVATION THAT WILL PROVIDE A MINIMUM OF 17’-6" VERTICAL CLEARANCE ABOVE THE HIGHEST POINT OF THE ENTIRE ROADWAY WIDTH (INCLUDING THE ROADWAY PAVEMENT AND SHOULDERS) PASSING UNDER THE STRUCTURE. SET THE BOTTOM OF ALL SIGN PANELS TO GENERALLY THE SAME ELEVATION. IN THE CASE OF A STRUCTURE SPANNING DUAL ROADWAYS WHERE THE DIFFERENCE IN ELEVATIONS OF THE HIGHEST POINT ON EACH ROADWAY IS GREATER THAN 2’-6", SET THE BOTTOM OF ALL SIGN PANELS OVER EACH ROADWAY TO THE SAME VERTICAL CLEARANCE. THE TRAFFIC ENGINEER SETS THE DESIGN SIGN AREA USING ONE OF THE FOLLOWING OPTIONS: WHEN THE ULTIMATE SIGN AREA IS USED FOR DESIGN SET THE STRUCTURE TO AN ELEVATION THAT PLACES THE CENTER OF THE STRUCTURE AT 9’-3" ABOVE THE BOTTOM OF THE SIGN PANELS. WHEN THE STRUCTURE SPANS DUAL ROADWAYS WITH THE DIFFERENCE IN HIGH POINT ELEVATIONS GREATER THAN 2’-6", SET THE STRUCTURE TO AN ELEVATION THAT PLACES THE CENTER OF THE STRUCTURE AT 9’-3" ABOVE THE BOTTOM OF THE SIGN PANELS OVER THE UPPER ROADWAY. 1. THE ACTUAL SIGN AREA TO BE PLACED ON THE STRUCTURE AT THE TIME OF CONSTRUCTION. 2. THE ACTUAL SIGN AREA INCREASED BY 25%, BASED ON THE PROBABILITY OF SIGNS BEING ADDED OR INCREASED IN SIZE. (RURAL HIGHWAY DEFINITION OF "DESIGN SIGN AREA"). 20’ 24’ 18’ 30’ 7’ 22’ C L STRUCTURE & 2 1 C L SIGN PANEL NO. 2 9’ SEE THE FOLLOWING DIAGRAMS FOR ADDITIONAL INSTRUCTIONS FOR POSITIONING THE SIGN PANELS AND SIGN STRUCTURE. 60’ 16’ POSITIONING OF SIGN PANELS AND SIGN STRUCTURE 18’ SET THE TOP OF FOOTING ELEVATION SO THAT A MINIMUM 2’-0" COVER IS PROVIDED OVER THE FOOTING AT ALL LOCATIONS. NOTE: ELEVATIONS ARE IN FEET 3. THE ACTUAL SIGN AREA INCREASED BY 50%, BASED ON THE FOR ILLUSTRATIVE EXAMPLES OF HOW TO POSITION SIGN PANELS AND SIGN STRUCTURES, SEE CASES A-F ON THE NEXT SHEET. PROBABILITY OF SIGNS BEING ADDED OR INCREASED IN SIZE. (URBAN HIGHWAY DEFINITION OF "DESIGN SIGN AREA"). C L COLUMN C L COLUMN ELEV. 1000.00 DESIGNS FOR TWO TYPES OF LOADING CONDITIONS ARE PRESENTED IN THE DESIGN TABLES. TYPE 1 LOADING IS TO BE USED WHEN THE CENTER OF GRAVITY OF THE TOTAL DESIGN SIGN AREA LIES BETWEEN 0.42 X SPAN LENGTH AND 0.58 X SPAN LENGTH. TYPE 2 LOADING IS TO BE USED WHEN THE CENTER OF GRAVITY OF THE DESIGN SIGN AREA LIES BETWEEN THE BEGINNING OF THE SPAN AND 0.42 X SPAN LENGTH OR 0.58 X SPAN LENGTH AND END OF SPAN. DETERMINE THE CENTER OF GRAVITY OF THE DESIGN SIGN AREA AND USE THE APPROPRIATE LOADING CONDITION FOR SELECTING THE MEMBER SIZES. WHEN DETERMINING THE THE DESIGN SIGN AREA WILL BE ROUNDED UP TO THE NEXT HIGHEST INCREMENT OF SIGN AREA SHOWN IN THE DESIGN TABLES. CLEARLY SHOW THE DESIGN AREA USED ON THE DESIGN PLANS FOR FUTURE REFERENCE. WHEN MULTIPLE SIGN PANELS ARE PLACED ON ONE STRUCTURE AND ONE OR MORE OF THE SIGN PANELS IS NOT CENTERED IN THE VERTICAL DIRECTION, COMPUTE THE DESIGN SIGN AREA IN THE FOLLOWING MANNER: CENTER OF GRAVITY OF DESIGN SIGN AREA, USE THE INDIVIDUAL SIGN AREAS AS CALCULATED IN ACCORDANCE WITH THE PROCEDURE FOR CENTERED AND OFF-CENTER SIGNS. THE SIGN AREA FOR ANY SIGN PANEL CENTERED IN ELEV. 998.75 ELEV. = 1000.00 - 998.75 = 1.25 < 2’-6" Y1 = 16’ Y } USE CASE B } < Y2 1 Y 2 = 18’ SET BOTTOM OF EACH SIGN PANEL AT SAME ELEVATION THE VERTICAL DIRECTION IS (X) x (Y) ELEV. 1000.00 + 17’-6" + 1’-8" = 1019.17 THE SIGN AREA FOR ANY SIGN PANEL OFF-CENTER IN [1’-8" = BOTTOM OF LUMINAIRE SUPPORT TO BOTTOM OF SIGN PANEL] THE VERTICAL DIRECTION IS (X) x (B) x 2 WHEN B>A OR (X) x (A) x 2 C L OF SIGN PANEL NO. 2 SET C L STRUCTURE AT WHEN A>B. ELEV. 1019.17 + 18’/2 = 1028.17 EXAMPLE: AREA OF SIGN NO. 1 = (X ) x (Y 1 1 ) ACTUAL SPAN LENGTH = 114’ AREA OF SIGN NO. 2 = 2 (X ) x (B 2 ) x 2 AREA OF SIGN NO. 3 = 3 (X ) x (A 3 ) x 2 USE: 120’ DESIGN COLUMN HEIGHT (H): X1 A3 >Y3 /2 A2 <Y2 /2 H = 1028.17 - 998.750 = 29.42’ STRUCTURE DEPTH IS 2’-7". THEREFORE FROM THE DESIGN TABLES, X3 C.G. SIGN PANELS C L COLUMN C L COLUMN 1 3 3 BECAUSE SIGN PANEL NO. 1 IS NOT CENTERED VERTICALLY ON THE STRUCTURE, THE DESIGN AREAS ARE COMPUTED AS FOLLOWS: A A Y C L STRUCTURE 1 1= 2= 22’ x 9’ x 2 = 396.0 SF 24’ x 18’ = 432.0 SF 828.0 SF L 2 Y2 USE 830.0 SF 1 Y/2 IT IS DETERMINED THAT THE TOTAL STRUCTURE DEPTH IS 5’-3" D X2 Y/2 Y1 USE H = OVER 24’ TO 33’ C L SIGN TO BOTTOM OF CATWALK IS 9’-0" + 1’-8" = 10’-8" B3 <Y3 /2 B2 >Y2 /2 LOCATE C.G. OF SIGN AREA (FROM LEFT) IF 0.42L < D < 0.58L, USE LOADING TYPE 1 ( IF D < 0.42L, OR D > 0.58L, USE LOADING TYPE 2 X = 52.40’ ) SF x (20’ + 22’/2)] + [432.0 SF x (60’ + 24’/2)] X [396.0 = 828 SF 52.4’/114’ = 0.46; 0.42 < 0.46 < 0.58 VERIFY LOADING TYPE BASED ON ACTUAL SIGN AREA AND C.G. C L COLUMN C L COLUMN LOADING TYPE DIAGRAM IF LOADING TYPES DIFFER USE THE LARGEST MEMBER SIZES FROM EACH LOADING TYPE. THE DESIGN SPAN LENGTH SHALL BE THE ACTUAL SPAN LENGTH ROUNDED UP TO THE NEXT HIGHEST INCREMENT OF SPAN LENGTH SHOWN IN THE DESIGN TABLES. C A = DISTANCE FROM L STRUCTURE TO TOP OF SIGN C STRUCTURE TO BOTTOM OF SIGN B = DISTANCE FROM L THE DESIGN POST HEIGHT SHALL BE THE ACTUAL DESIGN POST HEIGHT ROUNDED UP TO THE NEXT HIGHEST INCREMENT OF POST HEIGHT SHOWN IN THE DESIGN TABLES. DESIGN AREA OF SIGN NO.1 = X Y 1 1 DESIGN AREA OF SIGN NO.2 = (X )x2 2 B 2 DESIGN AREA OF SIGN NO.3 = (X A )x2 3 3 COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY OVERHEAD SIGN STRUCTURES 4 POST 4 CHORD TRUSS SPANS FROM 100’ TO 200’ DESIGN INSTRUCTIONS RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHT. 2 OF 7 BD-645M 9’-3" C L STRUCTURE Y 1 1 2 Y2 Y 1 C L STRUCTURE 1 Y2 2 C C+Y1 /2+ C ELEV. ELEV. C CASE A C L STRUCTURE 2 9’-3" MAX. C+ 1 1 C+Y2 /2 C 2 Y ELEV. ELEV.+Y2 /2 Y C+ ELEV. C+ C MAX. C L STRUCTURE ELEV.+Y1 /2 2 1 C+ 1 ELEV. Y2 Y C CASE C ELEV. ELEV. Y 1 = Y Y > Y2 1 2 ELEV.< 2’-6" ELEV.< 2’-6" CASE F CASE E SET BOTTOMS OF SIGN PANELS AT SAME ELEVATION. SET BOTTOMS OF SIGN PANELS AT SAME ELEVATION. C OF STRUCTURE AT C SET L L OF SIGN PANELS UNLESS Y SET C L OF STRUCTURE ATCL OF SIGN PANEL NO. 1 UNLESS STRUCTURE DEPTH GOVERNS VERTICAL CLEARANCE. IN 1 ELEV.> 2’-6" STRUCTURE DEPTH GOVERNS VERTICAL CLEARANCE. IN THIS CASE, RESET C STRUCTURE TO OBTAIN ADEQUATE L CLEARANCE. Y < Y2 > Y 2 - 1 ELEV.> 2’-6" THIS CASE, RESET C STRUCTURE TO OBTAIN ADEQUATE L CLEARANCE. SET BOTTOM OF EACH SIGN PANEL TO SAME VERTICAL SET BOTTOM OF EACH SIGN PANEL TO SAME VERTICAL CLEARANCE. THIS CASE IS APPLICABLE FOR ALL COMBINATIONS OF CLEARANCE. Y AND Y WHERE1Y > 2 Y . 1 2 SET C L OF STRUCTURE ATCL OF SIGN PANEL NO. 1 UNLESS C C SET L OF STRUCTURE AT L OF SIGN PANEL NO. 2 UNLESS STRUCTURE DEPTH GOVERNS VERTICAL CLEARANCE. IN THIS CASE, RESET C STRUCTURE TO OBTAIN ADEQUATE L CLEARANCE. STRUCTURE DEPTH GOVERNS VERTICAL CLEARANCE. IN THIS CASE, RESET C STRUCTURE TO OBTAIN ADEQUATE L CLEARANCE. THIS CASE IS APPLICABLE FOR THE FOLLOWING THIS CASE IS APPLICABLE FOR THE FOLLOWING COMBINATIONS OF 1 Y2 2 C L STRUCTURE 2 1 ELEV. 3’-0" Y1,2 ELEV. LIMITS OF Y 1 AND Y Y2 2 C C 4’-0" 6’-0" TO 10’-6" 5’-0" 6’-0" TO 8’-6" 6’-0" 6’-0" TO 6’-6" 6’-3" 6’-0" 2Y 1 - Y2< 12’-6" 4’-0" 2Y 1 - Y2< 10’-6" 5’-0" 2Y 1 - Y2< 8’-6" 6’-0" 2Y 1 - Y2< 6’-6" 7’-0" 2Y 1 - Y2< 4’-6" WHENY2 EXCEEDS THE RANGE SHOWN IN THE ABOVE TABLE FOR A PARTICULAR VALUE OF ELEV., THIS CASE DOES NOT APPLY. USE EITHER 1) SEPARATE STRUCTURES, OR 2) A SPECIAL DESIGN. GENERAL EQUATION FOR CASE F: 2( C+ ELEV.+Y1 /2 MAX. C+ ELEV.+Y2 /2 9’-3" 2 6’-0" TO 12’-6" 3’-0" C ELEV. , Y , AND Y WHERE 1 Y < Y 2 : 1 2 1 C L STRUCTURE Y 1 ELEV. 1 C+ Y COMBINATIONS OF ELEV. AND Y WHERE Y > Y : 2 ELEV.) + 2(Y ) - Y 2 1 < 18’-6" - IF THE PARAMETERS OF THE GENERAL EQUATION ARE ELEV. EXCEEDED, ONE OF THE FOLLOWING STEPS IS REQUIRED: ELEV. NOTE: C IS VERTICAL CLEARANCE FROM ROADWAY TO CASE B CASE D BOTTOM OF STRUCTURE, SIGN PANEL, OR LUMINAIRE. 1) RESET C STRUCTURE SO THAT PARAMETERS ARE MET L 2) USE SEPARATE STRUCTURES 3) USE A SPECIAL DESIGN 4) IN ALL CASES, THE MINIMUM VERTICAL CLEARANCE OF 17’-6" MUST BE MAINTAINED Y < Y2 1 Y = Y 2 1 ELEV.< 2’-6" ELEV.> 2’-6" SET BOTTOMS OF SIGN PANELS AT SAME ELEVATION. SET BOTTOM OF EACH SIGN PANEL TO SAME VERTICAL CLEARANCE. C SET L OF STRUCTURE ATCL OF SIGN PANEL NO. 2 UNLESS STRUCTURE DEPTH GOVERNS VERTICAL CLEARANCE. IN THIS CASE, RESET C STRUCTURE TO OBTAIN ADEQUATE L CLEARANCE. C SET L OF STRUCTURE ATCL OF SIGN PANEL NO. 1 UNLESS STRUCTURE DEPTH GOVERNS VERTICAL CLEARANCE. IN THIS CASE, RESET C STRUCTURE TO OBTAIN ADEQUATE L CLEARANCE. THIS CASE IS APPLICABLE FOR ALL COMBINATIONS OF Y AND Y WHERE1Y < 2 Y . 1 2 THIS CASE IS APPLICABLE FOR THE FOLLOWING COMBINATIONS OF ELEV. AND 1,2 Y : COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY OVERHEAD SIGN STRUCTURES WHEN Y 1,2 EXCEEDS THE RANGE SHOWN IN THE ABOVE TABLE FOR A PARTICULAR VALUE OF ELEV., THIS CASE DOES NOT 4 POST 4 CHORD TRUSS APPLY. USE EITHER 1) SEPARATE STRUCTURES, OR 2) A SPECIAL DESIGN. SPANS FROM 100’ TO 200’ INSTRUCTIONS FOR USE OF DESIGN TABLES RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHT. 3 OF 7 BD-645M STA. AHEAD 90 C L ROADWAY TRUSS CHORD A (O.D.)x(WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. TRUSS CHORD B (O.D.)x(WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. DESIGN CRITERA TOP DIAGONALS (O.D.)x(WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. TRUSS CHORD C (O.D.)x(WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. SIGN AREA (A)= SPAN LENGTH (L)= STRUCTURE HEIGHT (H)= SIGN STRUCTURE STA. COLUMN (TYP.) LOADING TYPE= 1+ 40 0 C L OF SIGN STRUCTURE STA. TOP & BOTTOM (O.D.)x(WALL THK.). SEE BC-745M FOR TRAFFIC FABRICATION DETAILS. FATIGUE CATEGORY= BOTTOM DIAGONAL (O.D.)x(WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. END VERTICAL TRAFFIC (1 OR 2) NOTE: DESIGN FOR (ULTIMATE OR ACTUAL) SIGN AREA. (DESIGNER TO INDICATE CONTROLLING CONDITION) TOP & BOTTOM END VERTICAL TOP VIEW (O.D.)x(WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. SEE PLAN SHEET FOR SIGN STRUCTURE LOCATION LOCATION PLAN TOP DIAGONAL OR END VERTICAL (M) PANELS - CHORD C C L SPLICE C L SPLICE VERTICALS= TRUSS CHORD B (O.D.)x(WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. PANEL LENGTH = (TYP.) DIST. TO END TOP TRUSS CHORDS A, B, & C VERTICALS= REAR DIAGONAL (O.D.)x(WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. FRONT DIAGONAL (O.D.)x(WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. C OL U MN DIST. TO END (N AND P) PANELS - CHORD B "B " 4’-0" ACTUAL SPAN LENGTH = (M) PANELS - CHORD A C OL U MN DESIGN SPAN LENGTH (L) "A " C L COLUMN "B" C L COLUMN "A" C L STRUCTURE EL.= FRONT DIAGONAL OR END VERTICAL TRUSS HEIGHT = BOTTOM TRUSS CHORDS A, B, & C C L STRUCTURE EL. FRONT & REAR BOTTOM DIAGONAL OR END VERTICAL END VERTICAL SIGN LENGTH = COLUMN SIZE IS (O.D.) x (WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. COLUMN COLUMN SEE TABLE "A", BC-745M OR AS REQ’D. BY OWNER C L ROADWAY PAVEMENT VARIABLE PAVEMENT MEDIAN EDGE OF PAVEMENT NON-SHRINK GROUT (TYP.) ACTUAL VERT. CLR.= MIN. VERT. CLR.= 17’-6" MIN. PT. OF MIN. VERT. CLR. TOP OF ROADWAY EL. SEE TABLE "A", BC-745M OR AS REQ’D. BY OWNER VARIABLE EDGE OF PAVEMENT BC-745M FOR REINFORCENENT PEDESTAL TYPE (SIZE). SEE REQUIREMENTS AND DETAILS. 2’-0" MIN. ELEVATION FOOTING TYPE (SIZE). SEE BC-745M FOR REINFORCEMENT REQUIREMENTS AND DETAILS. FOOTING WIDTH "G" SEE BC-745M COLUMN "B" BOTTOM OF FOOTING EL. BOTTOM OF FOOTING EL. COLUMN "A" FOR FILL HEIGHTS < 10’. REQUIREMENTS AND DETAILS. FOOTING TYPE (SIZE). SEE BC-745M FOR REINFORCEMENT REQUIREMENTS AND DETAILS. PL DESIGNER MUST CHECK ADEQUACY OF FOOTINGS BC-745M FOR REINFORCENENT FOOTING WIDTH "G" SEE BC-745M PEDESTAL 10’-0" PEDESTAL TYPE (SIZE). SEE HEIGHT (H) TOP OF PEDESTAL TOP OF PEDESTAL EL. 6" TOP OF BASEPLATE 6" TOP OF PEDESTAL EL. 10’-0" COLUMN BRACING IS ST (DP)x(WT.). SEE BC-745M FOR FABRICATION DETAILS. HEIGHT SIGN LENGTH = NOTE: SIGNS NOT SHOWN FOR CLARITY TRUSS CHORD C (O.D.)x(WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. DESIGN SIGN HEIGHT = COLUMN HT. = ADDITIONAL DEPTH FOR SIGN LIGHTING AND/OR CATWALKS AS REQUIRED (NO.) EQUAL SPACES = FABRICATION DETAILS. SIGN HEIGHT = 2’-0" MIN. REAR DIAGONAL OR END VERTICAL (O.D.)x(WALL THK.). SEE BC-745M FOR TRUSS CHORD A (O.D.)x(WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. (NO.) EQUAL SPACES = SEE BC-745M FOR FABRICATION DETAILS. FRONT & REAR END VERTICALS 9’-3" MAX. COLUMN HT. = (O.D.)x(WALL THK.). 2’-0" FOOTING LENGTH "F" SEE BC-745M NOTES TO DESIGNER: END VIEW PLACE THE FOLLOWING NOTES ON CONTRACT DRAWINGS BASED ON INFORMATION OBTAINED FROM DESIGN TABLES AS INDICATED. DESIGNER MUST PROVIDE INFORMATION IN ( ) PARENTHESES. 1. PEDESTAL TYPE (SIZE). SEE BC-745M FOR REINFORCEMENT REQUIREMENTS AND DETAILS. 2. FOOTING TYPE (SIZE). SEE BC-745M FOR REINFORCEMENT REQUIREMENTS AND DETAILS. 3. COLUMN SIZE IS (O.D.) x (WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. 4. COLUMN BRACING IS ST(DP)x(WT.). SEE BC-745M FOR FABRICATION DETAILS. 5. TRUSS CHORD A (O.D.) x (WALL THK.), TRUSS CHORD B (O.D.) x (W.THK.), AND TRUSS CHORD C (O.D.) x (WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. 6. FRONT & REAR DIAGONALS (O.D.) x (WALL THK.) AND FRONT & REAR END VERTICALS (O.D.) x (WALL THK.); TOP & BOTTOM DIAGONALS (O.D.) x (WALL THK.) AND TOP & BOTTOM END VERTICALS (O.D.) x (WALL THK.). SEE BC-745M FOR FABRICATION DETAILS. TABLE OF ESTIMATED QUANTITIES ITEM NO. ITEM STEEL SIGN STRUCTURE UNIT LBS 0000-0000 STRUCTURE MOUNTED SIGNS SF 0000-0000 CLASS 3 EXCAVATION CF 0000-0000 CLASS A CEMENT CONCRETE CF 0000-0000 REINFORCEMENT BARS LBS ITEMS SHOWN FOR INFORMATION ONLY, INCLUDED IN PROVIDE DIMENSIONS AND ELEVATIONS BASED ON ACTUAL STRUCTURE CONFIGURATION AS REQUIRED. SAMPLE INDICATES MINIMUM REQUIRED INFORMATION WITH 0.31Y 0.59Y 0.81Y 0.95Y 0.95Y 0.81Y 0.59Y COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY OVERHEAD SIGN STRUCTURES QUANTITY PLACE CAMBER DIAGRAM ON CONTRACT DRAWINGS AND SPECIFY REQUIRED CAMBER FROM CAMBER TABLE. 0.31Y CAMBER (Y) = .1L .2L .3L .4L .5L .6L .7L .8L .9L 90 90 4 POST 4 CHORD TRUSS SPANS FROM 100’ TO 200’ L CAMBER DIAGRAM SAMPLE CONTRACT DRAWING NOTE: PRIOR TO SHIPMENT OF TRUSS STRUCTURE TO THE SITE, SHOP ASSEMBLE TRUSSES IN AN UPRIGHT POSITION AND CHECK TRUSS CAMBER. RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHT. 4 OF 7 LUMP SUM ITEM NO. 0000 - 0000 . DESIGNER TO PROVIDE DIMENSIONS ON CONTRACT DRAWINGS. CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-645M LOADING TYPE 1 SIGN DESIGN (SQ.FT.) TO 100’ TRUSS (PIPE NOMINAL SIZE x WALL THK.) SPAN PED. TYPE END VERTICALS DIAGONALS CHORDS AREA FOUNDATION TOWER MEMBERS TRUSS MEMBERS FRONT & TOP & H TO 12’ FRONT & TOP & CROSS BRACING COLUMN ** H OVER 12’ H OVER 18’ H OVER 24’ TO 18’ TO 24’ TO 33’ H OVER 18’ H OVER 12’ H TO 12’ TO 18’ PED. PED. H OVER 24’ TO 33’ TO 24’ PED. PED. A B C REAR BOTTOM REAR BOTTOM 200 6x.432* 6x.432* 6x.432* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 10x.365* 2x3.85 12x.375* 2x4.75 16x.375* 3x6.25 24x.375* 3x6.25 FP12 716 FP12 718 FP16 819 FP24 820 350 6x.432* 6x.432* 6x.432* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 10x.365* 2x4.75 12x.375* 2.5x5.0 16x.375* 3x6.25 24x.375* 3x8.625 FP12 718 FP12 718 FP16 819 FP24 922 500 6x.432* 6x.432* 6x.432* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 10x.365* 2.5x5.0 12x.375* 3x6.25 16x.375* 3x8.625 24x.375* 4x9.2 FP12 718 FP12 720 FP16 921 FP24 924 650 6x.432* 6x.432* 6x.432* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 10x.365* 3x6.25 12x.375* 3x6.25 16x.375* 4x9.2 24x.375* 4x9.2 FP12 820 FP12 822 FP16 923 FP24 924 800 8x.322* 8x.322* 8x.322* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 12x.375* 3x6.25 14x.375* 3x8.625 16x.375* 4x9.2 24x.375* 4x9.2 FP12 822 FP16 923 FP16 923 FP24 1026 BRACING COLUMN ** COLUMN ** BRACING BRACING COLUMN ** BRACING FTG. TYPE FTG. FTG. TYPE TYPE TYPE FTG. 950 8x.322* 8x.322* 8x.322* 3x.216 3x.216 3x.216 3x.216 3x.216 12x.375 3x8.625 16x.375* 4x11.5 18x.375* 4x11.5 24x.375* 4x11.5 FP12 822 FP16 923 FP20 1025 FP24 1223 1100 8x.322* 8x.322* 8x.322* 3x.216 3x.216 3x.216 3x.216 3x.216 14x.375* 3x8.625 16x.375* 4x11.5 18x.375* 4x11.5 24x.375* 5x17.5 FP16 923 FP16 923 FP20 1025 FP24 1325 1250 8x.322* 8x.322* 8x.322* 3x.216 3x.216 3x.216 3x.216 3x.216 16x.375* 3x8.625 18x.375* 4x11.5 20x.375* 6x17.5 24x.375* 5x17.5 FP16 923 FP20 1025 FP20 1324 FP24 1325 1400 8x.322* 8x.322* 8x.322* 3x.300 3x.300 3x.300 3x.300 3x.300 16x.375* 4x9.2 18x.375* 5x17.5 20x.375* 5x17.5 24x.500 5x17.5 FP16 1025 FP20 1025 FP20 1324 FP24 1325 1550 8x.322* 8x.322* 8x.322* 3x.300 3x.300 3x.300 3x.300 3x.300 16x.375* 4x9.2 18x.375* 5x17.5 20x.375* 5x17.5 24x.500 5x17.5 FP16 1025 FP20 1025 FP20 1324 FP24 1325 1700 8x.322* 8x.322* 8x.322* 3x.300 3x.300 3x.300 3x.300 3x.300 18x.375* 4x9.2 20x.375* 5x17.5 24x.375* 5x17.5 24x.500 5x17.5 FP20 1025 FP20 1222 FP24 1325 FP24 1427 1850 8x.322* 8x.322* 8x.322* 3x.300 3x.300 3x.300 3x.300 3x.300 20x.375* 4x9.2 20x.375* 5x17.5 24x.375* 5x17.5 24x.500 6x17.5 FP20 1125 FP20 1324 FP24 1325 FP24 1429 FOR CONTINUATION OF CHART, SEE SHEET 6. - INDICATES FOUNDATION PEDESTAL TYPE. - MEMBER SIZE SHOWN WAS SELECTED BASED ON AVAILABILITY OF STD., XS, OR XXS PIPE. IF AVAILABLE, THE SAME NOMINAL DIAMETER PIPE WITH THE NEXT THINNER WALL THICKNESS, AS PER ASTM A53-90b, MAY BE USED, EXCEPT PROVIDE MINIMUM WALL THICKNESS OF " FOR COLUMNS AND CHORDS. - SEE GENERAL NOTE 11 ON SHEET 1. - COLUMN BRACING MEMBERS ARE ST SHAPES, UNLESS NOTED OTHERWISE. SECTION DESIGNATION INDICATES MEMBER DEPTH (DP)x WEIGHT PER FOOT (WT). 4’-0" 180’ 6.37 200’ 8.20 .1L TRUSS HEIGHT TOP/BOTTOM END VERTICAL .2L .3L .4L .5L .6L .7L .8L 0.31Y 5.96 0.59Y 4.55 160’ 0.81Y 140’ 0.59Y BACK TRUSS CHORDS 0.31Y BOTTOM DIAGONAL CAMBER=Y 4.22 0.95Y 3.01 120’ TOP DIAGONAL 0.81Y CAMBER (IN.) 100’ 0.95Y CAMBER TABLE SPAN .9L 90 90 TOP/BOTTOM FRONT TRUSS CHORDS END VERTICAL VIEW A-A FRONT DIAGONAL REAR DIAGONAL PANEL LENGTH SPAN TH UP TO 120’ 4’-0" 120’+ TO 160’ 5’-0" 160’+ TO 200’ 6’-0" L CAMBER DIAGRAM TOP DIAGONAL OR END VERTICAL A A TOP TRUSS CHORDS TOP TRUSS CHORDS NOTES: TH C L TRUSS FRONT DIAGONAL OR END VERTICAL FOR GENERAL NOTES, SEE SHEET 1. FOR GENERAL DESIGN INSTRUCTIONS, SEE SHEETS 2 AND 3. BOTTOM TRUSS CHORDS FRONT/REAR BOTTOM TRUSS CHORDS FRONT/REAR END VERTICAL ONE OR MORE SPLICES IN THE TRUSS MAY BE ADDED OR ELIMINATED AT THE OPTION OF THE FABRICATOR. IN CASE OF THE ADDITION OR ELIMINATION OF SPLICES, THE HEAVIER CHORD MATERIAL MUST BE EXTENDED TOWARD THE LIGHTER CHORD MATERIAL TO THE DESIRED SPLICE LOCATION. BOTTOM DIAGONAL OR END VERTICAL END VERTICAL REAR DIAGONAL OR END VERTICAL SIGN AREA 10" "FOOTING TYPE" DESIGNATION INDICATES FOOTING WIDTH x LENGTH (FOR EXAMPLE, FOOTING TYPE 716 INDICATES A FOOTING 7’ WIDE x 16’ LONG). SEE BC-745M, SHEET 2 AND 3 FOR FOUNDATION DETAILS. 10" NOTE: SIGN NOT SHOWN FOR CLARITY FOOTING DESIGN BASED ON 10 FOOT FILL HEIGHT. DESIGNER MUST CHECK ADEQUACY FOR FILL HEIGHTS < 10’. C L COLUMN FOR STRUCTURAL DETAILS, SEE BC-745M. H FOR PEDESTAL DETAILS , SEE BC-745M SHEET 2. (M) PANELS - CHORD A (2N+P) PANELS - CHORD B BRACING (M) PANELS - CHORD C COMMONWEALTH OF PENNSYLVANIA L = SPAN LENGTH PEDESTAL PEDESTAL PT FOR PEDESTAL AND FOOTING DETAILS, SEE BC-745M SHEETS 2 AND 3. FOOTING 11’-0" OF M, N, & P SEE SHEET 6. TOP OF BASEPLATE MAX. TOP OF FOR SPLICE LOCATIONS AND VALUES 2’-6" MIN. NOTE; DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY "P" BARS OVERHEAD SIGN STRUCTURES PL 4 POST 4 CHORD TRUSS SPANS FROM 100’ TO 200’ 2’-0" DESIGN TABLES LOADING TYPE 1 FOOTING WIDTH ELEVATION FOOTING LENGTH SIDE VIEW RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHT. 5 OF 7 BD-645M LOADING TYPE 1 (CONTINUED) SIGN DESIGN AREA TOP & FRONT & BOTTOM H OVER 18’ H OVER 24’ TO 18’ TO 24’ TO 33’ H OVER 12’ H TO 12’ TO 18’ H OVER 18’ H OVER 24’ TO 33’ TO 24’ CROSS REAR TOP & BOTTOM BRACING COLUMN ** COLUMN ** PED. PED. PED. PED. B C REAR 6x.432* 6x.432* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 10x.365* 2.5x5.0 12x.375* 3x6.25 16x.375* 3x8.625 24x.375* 3x8.625 FP12 717 FP12 718 FP16 819 FP24 600 8x.322* 8x.322* 8x.322* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 12x.375* 3x6.25 12x.375* 3x8.625 16x.375* 4x9.2 24x.375* 4x9.2 FP12 820 FP12 822 FP16 923 FP24 924 900 8x.322* 8x.322* 8x.322* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 12x.375* 3x8.625 16x.375* 4x9.2 18x.375* 4x11.5 24x.375* 4x11.5 FP12 822 FP16 923 FP20 1025 FP24 1026 1200 8x.500* 8x.500* 8x.500* 3x.216 3x.216 3x.216 3x.216 3x.216 14x.375 4x9.2 16x.375* 5x17.5 18x.375* 5x17.5 24x.375* 5x17.5 FP16 923 FP16 1025 FP20 1222 FP24 1325 1500 8x.500* 8x.500* 8x.500* 3x.300 3x.300 3x.300 3x.300 3x.300 16x.375 4x9.2 18x.375* 5x17.5 24x.375* 6x17.5 24x.500* 6x17.5 FP16 1025 FP20 1222 FP24 1325 FP24 1427 1800 8x.500 8x.500 8x.500 3x.300 3x.300 3x.300 3x.300 3x.300 18x.375* 4x11.5 20x.375* 6x17.5 24x.375* 6x17.5 24x.500* 6x17.5 FP20 1025 FP20 1324 FP24 1427 FP26 1528 2100 8x.500 8x.500 8x.500 3x.300 3x.300 3x.300 3x.300 3x.300 18x.375* 4x11.5 20x.375* 6x17.5 24x.375* 6x17.5 24x.500 6x17.5 FP20 1324 FP20 1324 FP24 1427 FP26 1528 2220 8x.500 8x.500 8x.500 3x.300 3x.300 3x.300 3x.300 3x.300 20x.375* 4x11.5 20x.375* 6x17.5 24x.375* 6x17.5 24x.688 6x17.5 FP20 1324 FP20 1324 FP24 1427 FP26 1530 300 8x.322* 8x.322* 8x.322* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 12x.375* 2.5x5.0 12x.375* 3x6.25 16x.375* 3x8.625 24x.375* 3x8.625 FP12 717 FP12 820 FP16 921 FP24 922 600 8x.322* 8x.322* 8x.322* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 12x.375* 3x6.25 14x.375* 4x9.2 16x.375* 4x9.2 24x.375* 4x9.2 FP12 819 FP16 921 FP16 923 FP24 924 900 10x.365* 10x.365* 10x.365* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 14x.375* 3x8.625 16x.375* 4x11.5 18x.375* 4x11.5 24x.375* 4x11.5 FP16 921 FP16 923 FP20 1025 FP24 1223 1200 12x.375* 12x.375* 12x.375* 3x.216 3x.216 3x.216 3x.216 3x.216 16x.375* 5x17.5 18x.375* 5x17.5 20x.375 5x17.5 24x.500* 5x17.5 FP16 923 FP20 1222 FP20 1324 FP24 1325 1500 12x.375 12x.375 12x.375 3.5x.226 3.5x.226 3.5x.226 3.5x.226 3.5x.226 18x.375* 6x17.5 18x.375* 6x17.5 24x.375 6x17.5 24x.500* 6x17.5 FP20 1323 FP20 1324 FP24 1426 FP26 1429 1800 12x.500* 12x.500* 12x.500* 4x.237 4x.237 4x.237 4x.237 4x.237 20x.375* 6x17.5 24x.375* 6x17.5 24x.375* 6x17.5 24x.688 6x17.5 FP20 1324 FP24 1324 FP24 1427 FP24 1528 2100 12x.500* 12x.500* 12x.500* 5x.258 5x.258 5x.258 5x.258 5x.258 20x.375* 6x17.5 24x.375* 6x17.5 24x.500* 6x17.5 24x.688 6x20.4 FP20 1324 FP24 1427 FP24 1429 FP24 1530 2400 12x.500* 12x.500* 12x.500* 5x.258 5x.258 5x.258 5x.258 5x.258 20x.375* 6x17.5 24x.375* 6x17.5 26x.375* 6x17.5 24x.688 6x20.4 FP20 1324 FP24 1427 FP26 1528 FP24 1531 300 8x.322* 8x.322* 8x.322* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 12x.375* 2.5x5.0 14x.375* 3x8.625 16x.375* 3x8.625 24x.375* 4x9.2 FP12 818 FP16 819 FP16 921 FP24 922 600 10x.365* 10x.365* 10x.365* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 14x.375* 3x6.25 16x.375* 4x9.2 18x.375* 4x9.2 24x.375* 4x9.2 FP16 921 FP16 921 FP20 923 FP24 1026 1325 140’ TO 120’ A TO OVER 120’ FRONT & H OVER 12’ 6x.432* TO 160’ OVER 140’ TRUSS (PIPE NOMINAL SIZE x WALL THK.) H TO 12’ 300 TO 180’ OVER 160’ OVER 180’ END VERTICALS (SQ.FT.) TO 200’ OVER 100’ SPAN DIAGONALS CHORDS FOUNDATION TOWER MEMBERS TRUSS MEMBERS PED. TYPE BRACING COLUMN ** BRACING COLUMN ** BRACING BRACING TYPE FTG. FTG. TYPE TYPE FTG. TYPE FTG. 922 900 12x.375* 12x.375* 12x.375* 3x.216 3x.216 3x.216 3x.216 3x.216 16x.375* 4x11.5 16x.375* 4x11.5 20x.375* 5x17.5 24x.375* 5x17.5 FP16 1024 FP16 1025 FP20 1025 FP24 1200 12x.500* 12x.500* 12x.500* 3.5x.226 3.5x.226 3.5x.226 3.5x.226 3.5x.226 16x.375* 5x17.5 18x.375* 5x17.5 24x.375* 5x17.5 24x.500* 5x17.5 FP16 1024 FP20 1222 FP24 1325 FP24 1427 1500 12x.500 12x.500 12x.500 4x.237 4x.237 4x.237 4x.237 4x.237 18x.375* 6x17.5 20x.375* 6x17.5 24x.375* 6x17.5 24x.500* 6x17.5 FP20 1125 FP20 1324 FP24 1325 FP26 1429 1800 12x.562 12x.562 12x.562 4x.237 4x.237 4x.237 4x.237 4x.237 20x.375* 6x17.5 24x.375* 6x17.5 24x.375* 6x17.5 24x.688* 6x17.5 FP20 1324 FP24 1325 FP24 1427 FP24 1429 2100 12x.688 12x.688 12x.688 5x.258 5x.258 5x.258 5x.258 5x.258 24x.375* 6x17.5 24x.375* 6x17.5 26x.375* 6x17.5 24x.688* 6x20.4 FP24 1325 FP24 1427 FP26 1429 FP26 1530 1630 2400 12x.688 12x.688 12x.688 5x.258 5x.258 5x.258 5x.258 5x.258 24x.375* 6x17.5 26x.375 6x17.5 24x.500* 6x20.4 24x.969* 6x20.4 FP24 1426 FP26 1528 FP26 1530 FP26 300 10x.365* 10x.365* 10x.365* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 14x.375* 3x8.625 14x.375* 3x8.625 16x.375* 4x9.2 24x.375* 4x9.2 FP16 818 FP16 819 FP16 921 FP24 924 600 12x.375* 12x.375* 12x.375* 3x.216 3x.216 3x.216 3x.216 3x.216 16x.375* 4x9.2 16x.375* 4x9.2 18x.375 4x9.2 24x.375* 4x11.5 FP16 922 FP16 923 FP20 923 FP24 1026 900 12x.500* 12x.500* 12x.500* 3.5x.226 3.5x.226 3.5x.226 3.5x.226 3.5x.226 16x.375* 4x11.5 16x.375* 4x11.5 18x.375 5x17.5 24x.375* 5x17.5 FP16 1024 FP16 1025 FP20 1222 FP24 1325 1200 12x.500 12x.500 12x.500 3.5x.226 3.5x.226 3.5x.226 3.5x.226 3.5x.226 20x.375* 5x17.5 20x.375* 5x17.5 24x.375* 5x17.5 26x.375* 5x17.5 FP20 1222 FP20 1222 FP24 1325 FP26 1426 1500 12x.688 12x.688 12x.688 4x.237 4x.237 4x.237 4x.237 4x.237 20x.375* 5x17.5 24x.375* 6x17.5 24x.375* 6x17.5 24x.688* 6x17.5 FP20 1323 FP24 1325 FP24 1325 FP24 1427 1800 12x.688 12x.688 12x.688 5x.258 5x.258 5x.258 5x.258 5x.258 24x.375* 5x17.5 24x.375* 6x17.5 26x.375* 6x17.5 24x.688 6x17.5 FP24 1324 FP24 1325 FP26 1426 FP24 1429 2100 12x.688 12x.688 12x.688 5x.258 5x.258 5x.258 5x.258 5x.258 24x.375* 6x17.5 26x.375* 6x17.5 24x.500* 6x20.4 24x.969* 6x20.4 FP24 1325 FP26 1426 FP24 1429 FP26 1530 2400 12x.844 12x.844 12x.844 4x.337 4x.337 4x.337 4x.337 4x.337 24x.375 6x17.5 26x.375* 6x17.5 24x.688* 6x20.4 24x.969 6x20.4 FP24 1426 FP26 1528 FP24 1530 FP24 1533 300 10x.365* 10x.365* 10x.365* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 16x.375* 3x8.625 16x.375* 3x8.625 16x.375* 4x9.2 24x.375* 4x9.2 FP16 1016 FP16 1016 FP16 1117 FP24 1117 600 12x.500* 12x.500* 12x.500* 3.5x.226 3.5x.226 3.5x.226 3.5x.226 3.5x.226 16x.375* 4x9.2 16x.375* 4x9.2 20x.375* 4x9.2 24x.375* 4x11.5 FP16 1117 FP16 1117 FP20 1118 FP24 1221 900 12x.562 12x.562 12x.562 3.5x.226 3.5x.226 3.5x.226 3.5x.226 3.5x.226 16x.375* 4x9.2 18x.375 4x9.2 20x.375* 4x11.5 24x.500* 5x17.5 FP16 1117 FP20 1220 FP20 1120 FP24 1221 1200 12x.688 12x.688 12x.688 4x.237 4x.237 4x.237 4x.237 4x.237 18x.375* 5x17.5 20x.375* 5x17.5 24x.375* 5x17.5 24x.500* 5x17.5 FP20 1219 FP20 1221 FP24 1221 FP26 1324 1500 12x.844 12x.844 12x.844 5x.258 5x.258 5x.258 5x.258 5x.258 18x.375* 5x17.5 24x.375* 5x17.5 24x.375* 5x17.5 24x.688* 6x17.5 FP20 1219 FP24 1425 FP24 1221 FP24 1325 1800 12x.844 12x.844 12x.844 5x.258 5x.258 5x.258 5x.258 5x.258 24x.375* 5x17.5 26x.375* 5x17.5 26x.500* 6x17.5 24x.969* 6x17.5 FP24 1323 FP26 1324 FP26 1324 FP26 1426 - INDICATES FOUNDATION PEDESTAL TYPE. - MEMBER SIZE SHOWN WAS SELECTED BASED ON AVAILABILITY OF STD., XS, OR XXS PIPE. IF AVAILABLE, THE SAME NOMINAL DIAMETER PIPE WITH THE NEXT THINNER WALL THICKNESS, AS PER ASTM A53-90b, MAY BE USED, EXCEPT PROVIDE MINIMUM WALL THICKNESS OF " FOR COLUMNS AND CHORDS. - SEE GENERAL NOTE 11 ON SHEET 1. - COLUMN BRACING MEMBERS ARE ST SHAPES, UNLESS NOTED OTHERWISE. SECTION DESIGNATION INDICATES MEMBER DEPTH (DP)x WEIGHT PER FOOT (WT). NUMBER ACTUAL DESIGN SPAN SPAN NO. OF PANELS OF SPLICES M N P COMMONWEALTH OF PENNSYLVANIA UP TO 100’ 100’ 2 8 0 10 100’+ TO 120’ 120’ 2 10 0 10 DEPARTMENT OF TRANSPORTATION 120’+ TO 140’ 140’ 4 6 8 8 140’+ TO 160’ 160’ 4 8 8 8 160’+ TO 180’ 180’ 4 8 10 10 180’+ TO 200’ 200’ 4 10 10 10 BUREAU OF PROJECT DELIVERY OVERHEAD SIGN STRUCTURES 4 POST 4 CHORD TRUSS C L SPLICE SPANS FROM 100’ TO 200’ (TYPICAL) DESIGN TABLES M PANELS CHORD A N PANELS P PANELS CHORD B N PANELS M PANELS LOADING TYPE 1 CHORD C RECOMMENDED AUG. 31, 2012 RECOMMENDED AUG. 31, 2012 SHT. 6 OF 7 ELEVATION CHIEF BRIDGE ENGINEER ACTING DIR, BUR. OF PROJECT DELIVERY BD-645M LOADING TYPE 2 SIGN DESIGN AREA SPAN DIAGONALS CHORDS 100’ TO OVER 100’ TO 120’ OVER 120’ TO 140’ OVER 140’ TO 160’ OVER 160’ TO 180’ OVER 180’ TO 200’ PED. TYPE END VERTICALS TRUSS (PIPE NOMINAL SIZE x WALL THK.) (SQ.FT.) FOUNDATION TOWER MEMBERS TRUSS MEMBERS FRONT & TOP & FRONT & BOTTOM H TO 12’ H OVER 12’ H OVER 18’ H OVER 24’ TO 18’ TO 24’ TO 33’ H OVER 12’ H TO 12’ TO 18’ H OVER 18’ H OVER 24’ TO 33’ TO 24’ CROSS REAR TOP & BOTTOM BRACING COLUMN ** PED. PED. PED. PED. BRACING COLUMN ** 16x.375* 3x6.25 24x.375* 3x6.25 FP12 717 FP12 718 FP16 819 FP24 820 3x6.25 16x.375* 3x8.625 24x.375* 4x9.2 FP12 718 FP12 720 FP16 821 FP24 822 12x.375* 3x8.625 16x.375* 4x9.2 24x.375* 4x9.2 FP12 720 FP12 822 FP16 923 FP24 924 3x6.25 14x.375* 3x8.625 18x.375* 4x9.2 24x.375* 4x11.5 FP12 822 FP16 923 FP20 923 FP24 1026 1028 A B C REAR 200 6x.432* 6x.432* 6x.432* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 10x.365* 2x3.85 12x.375* 2x4.75 350 6x.432* 6x.432* 6x.432* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 10x.365* 2.5x5.0 12x.375* 500 6x.432* 6x.432* 6x.432* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 10x.365* 3x6.25 650 8x.322* 8x.322* 8x.322* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 12x.375* BRACING COLUMN ** BRACING COLUMN ** BRACING TYPE FTG. FTG. TYPE TYPE FTG. TYPE FTG. 800 8x.322* 8x.322* 8x.322* 3x.216 3x.216 3x.216 3x.216 3x.216 12x.375* 3x8.625 16x.375* 4x9.2 18x.375* 4x11.5 24x.375* 5x17.5 FP12 822 FP16 923 FP20 1025 FP24 950 8x.322* 8x.322* 8x.322* 3x.216 3x.216 3x.216 3x.216 3x.216 12x.375* 3x8.625 16x.375* 4x11.5 18x.375* 5x17.5 24x.375* 5x17.5 FP12 923 FP16 1025 FP20 1027 FP24 1028 1100 8x.322* 8x.322* 8x.322* 3x.300 3x.300 3x.300 3x.300 3x.300 14x.375* 3x8.625 16x.375* 5x17.5 18x.375* 5x17.5 24x.375* 5x17.5 FP16 923 FP16 1025 FP20 1027 FP24 1130 1250 8x.322* 8x.322* 8x.322* 3x.300 3x.300 3x.300 3x.300 3x.300 16x.375* 3x8.625 18x.375* 5x17.5 20x.375* 5x17.5 24x.375* 5x17.5 FP16 923 FP20 1027 FP20 1027 FP24 1325 1400 8x.322* 8x.322* 8x.322* 3x.300 3x.300 3x.300 3x.300 3x.300 16x.375* 4x9.2 18x.375* 5x17.5 20x.375* 5x17.5 24x.500* 5x17.5 FP16 1025 FP20 1027 FP20 1324 FP24 1427 1550 8x.322* 8x.322* 8x.322* 3x.300 3x.300 3x.300 3x.300 3x.300 16x.375* 4x9.2 18x.375* 5x17.5 24x.375* 5x17.5 24x.500* 5x17.5 FP16 1025 FP20 1222 FP24 1325 FP24 1427 300 6x.432* 6x.432* 6x.432* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 10x.365* 3x6.25 12x.375* 3x8.625 16x.375* 4x9.2 24x.375* 4x9.2 FP12 718 FP12 720 FP16 819 FP24 822 600 8x.322* 8x.322* 8x.322* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 12x.375* 3x8.625 14x.375* 4x9.2 18x.375* 4x11.5 24x.375* 4x11.5 FP12 820 FP16 923 FP20 923 FP24 1026 1028 900 8x.322* 8x.322* 8x.322* 3x.216 3x.216 3x.216 3x.216 3x.216 14x.375* 4x9.2 16x.375* 5x17.5 20x.375* 5x17.5 24x.375* 5x17.5 FP16 923 FP16 1025 FP20 1027 FP24 1200 8x.500* 8x.500* 8x.500* 3x.300 3x.300 3x.300 3x.300 3x.300 16x.375* 4x9.2 18x.375* 5x17.5 20x.375 6x17.5 24x.500* 6x17.5 FP16 1025 FP20 1027 FP20 1324 FP24 1427 1500 8x.500* 8x.500* 8x.500* 3x.300 3x.300 3x.300 3x.300 3x.300 16x.375* 4x11.5 18x.375* 6x17.5 24x.375 6x17.5 24x.500 6x17.5 FP16 1025 FP20 1027 FP24 1130 FP24 1429 1800 8x.500 8x.500 8x.500 3x.300 3x.300 3x.300 3x.300 3x.300 18x.375* 4x11.5 20x.375* 6x17.5 24x.375* 6x17.5 24x.688 6x17.5 FP20 1127 FP20 1324 FP24 1427 FP26 1429 1865 8x.500 8x.500 8x.500 3x.300 3x.300 3x.300 3x.300 3x.300 18x.375 4x11.5 20x.375* 6x17.5 24x.375* 6x17.5 24x.688 6x17.5 FP20 1324 FP20 1324 FP24 1427 FP26 1429 300 8x.322* 8x.322* 8x.322* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 12x.375* 2.5x5.0 12x.375* 3x8.625 16x.375* 4x9.2 24x.375* 4x9.2 FP12 718 FP12 720 FP16 821 FP24 924 600 8x.322* 8x.322* 8x.322* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 12x.375* 3x8.625 14x.375* 4x11.5 18x.375* 4x11.5 24x.375* 4x11.5 FP12 821 FP16 923 FP20 923 FP24 926 1130 900 10x.365* 10x.365* 10x.365* 3x.216 3x.216 3x.216 3x.216 3x.216 16x.375* 5x17.5 16x.375* 5x17.5 20x.375* 5x17.5 24x.375* 5x17.5 FP16 923 FP16 1025 FP20 1027 FP24 1200 12x.375* 12x.375* 12x.375* 3.5x.226 3.5x.226 3.5x.226 3.5x.226 3.5x.226 16x.375* 6x17.5 18x.375* 6x17.5 24x.375* 6x17.5 24x.500 6x17.5 FP16 1025 FP20 1027 FP24 1130 FP24 1429 1500 12x.375* 12x.375* 12x.375* 4x.237 4x.237 4x.237 4x.237 4x.237 18x.375* 6x17.5 20x.375* 6x17.5 24x.375* 6x17.5 26x.500 6x17.5 FP20 1323 FP20 1129 FP24 1427 FP26 1530 1800 12x.500* 12x.500* 12x.500* 4x.237 4x.237 4x.237 4x.237 4x.237 20x.375* 6x17.5 24x.375* 6x17.5 24x.375* 6x17.5 24x.688 6x20.4 FP20 1324 FP24 1325 FP24 1429 FP24 1531 2100 12x.500* 12x.500* 12x.500* 5x.258 5x.258 5x.258 5x.258 5x.258 20x.375* 6x17.5 24x.375* 6x17.5 24x.500 6x17.5 24x.688 6x20.4 FP20 1324 FP24 1427 FP24 1429 FP24 1531 2175 12x.500* 12x.500* 12x.500* 5x.258 5x.258 5x.258 5x.258 5x.258 20x.375* 6x17.5 24x.375* 6x17.5 24x.500 6x20.4 24x.688 6x20.4 FP20 1324 FP24 1427 FP26 1429 FP24 1531 300 8x.322* 8x.322* 8x.322* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 12x.375* 3x6.25 14x.375* 3x8.625 16x.375* 4x9.2 24x.375* 4x9.2 FP12 819 FP16 819 FP16 821 FP24 924 600 10x.365* 10x.365* 10x.365* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 14x.375* 3x8.625 16x.375* 4x11.5 18x.375* 4x11.5 24x.375* 5x17.5 FP16 821 FP16 923 FP20 1025 FP24 1028 1130 900 12x.375* 12x.375* 12x.375* 3x.216 3x.216 3x.216 3x.216 3x.216 16x.375* 5x17.5 18x.375* 5x17.5 20x.375 6x17.5 24x.375* 6x17.5 FP16 1024 FP20 1027 FP20 1027 FP24 1200 12x.500* 12x.500* 12x.500* 3.5x.226 3.5x.226 3.5x.226 3.5x.226 3.5x.226 18x.375* 6x17.5 20x.375* 6x17.5 24x.375 6x17.5 24x.500 6x17.5 FP20 1025 FP20 1027 FP24 1130 FP24 1429 1500 12x.500* 12x.500* 12x.500* 4x.237 4x.237 4x.237 4x.237 4x.237 20x.375* 6x17.5 24x.375* 6x17.5 24x.375* 6x17.5 24x.688 6x17.5 FP20 1324 FP24 1130 FP24 1429 FP26 1530 1800 12x.562 12x.562 12x.562 5x.258 5x.258 5x.258 5x.258 5x.258 20x.375 6x17.5 24x.375* 6x17.5 24x.500 6x20.4 24x.688 6x20.4 FP20 1324 FP24 1427 FP24 1429 FP24 1531 2100 12x.688 12x.688 12x.688 5x.258 5x.258 5x.258 5x.258 5x.258 24x.375* 6x17.5 24x.375 6x17.5 26x.375* 6x20.4 24x.688 6x20.4 FP24 1325 FP24 1427 FP26 1429 FP26 1533 1630 2400 12x.688 12x.688 12x.688 5x.258 5x.258 5x.258 5x.258 5x.258 24x.375* 6x17.5 26x.375 6x17.5 26x.500 6x20.4 24x.969 6x20.4 FP24 1427 FP26 1528 FP26 1530 FP26 300 10x.365* 10x.365* 10x.365* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 14x.375* 4x9.2 14x.375* 4x9.2 16x.375* 4x9.2 24x.375* 4x9.2 FP16 819 FP16 819 FP16 923 FP24 924 600 12x.375* 12x.375* 12x.375* 3x.216 3x.216 3x.216 3x.216 3x.216 16x.375* 4x11.5 16x.375* 4x11.5 18x.375* 5x17.5 24x.375* 5x17.5 FP16 923 FP16 923 FP20 925 FP24 1028 900 12x.500* 12x.500* 12x.500* 3.5x.226 3.5x.226 3.5x.226 3.5x.226 3.5x.226 16x.375 5x17.5 18x.375 5x17.5 24x.375* 6x17.5 24x.500 6x17.5 FP16 1025 FP20 1027 FP24 1028 FP24 1427 1200 12x.500* 12x.500* 12x.500* 4x.237 4x.237 4x.237 4x.237 4x.237 20x.375* 6x17.5 20x.375 6x17.5 24x.375* 6x17.5 26x.500* 6x17.5 FP20 1223 FP20 1129 FP24 1427 FP26 1530 1500 12x.688 12x.688 12x.688 5x.258 5x.258 5x.258 5x.258 5x.258 20x.375* 6x17.5 24x.375* 6x17.5 24x.500 6x17.5 24x.688* 6x17.5 FP20 1324 FP24 1325 FP24 1429 FP24 1531 1800 12x.688 12x.688 12x.688 5x.258 5x.258 5x.258 5x.258 5x.258 24x.375* 6x17.5 26x.375* 6x17.5 26x.375* 6x20.4 24x.969 6x20.4 FP24 1325 FP26 1427 FP26 1530 FP26 1531 2100 12x.688 12x.688 12x.688 5x.258 5x.258 5x.258 5x.258 5x.258 24x.375 6x17.5 26x.375* 6x20.4 24x.500* 6x20.4 24x.969 6x20.4 FP24 1427 FP26 1528 FP24 1531 FP26 1630 1533 2400 12x.844 12x.844 12x.844 4x.337 4x.337 4x.337 4x.337 4x.337 24x.375 6x17.5 26x.375* 6x20.4 24x.688 7.5x25 24x.969 7.5x25 FP24 1427 FP26 1528 FP24 1531 FP24 300 10x.365* 10x.365* 10x.365* 2.5x.203 2.5x.203 2.5x.203 2.5x.203 2.5x.203 16x.375* 3x8.625 16x.375* 3x8.625 16x.375* 4x9.2 24x.375* 4x9.2 FP16 819 FP16 819 FP16 819 FP24 822 600 12x.500* 12x.500* 12x.500* 3.5x.226 3.5x.226 3.5x.226 3.5x.226 3.5x.226 16x.375* 4x9.2 18x.375* 4x9.2 20x.375* 4x11.5 24x.375* 5x17.5 FP16 923 FP20 1025 FP20 923 FP24 1028 900 12x.562 12x.562 12x.562 3.5x.226 3.5x.226 3.5x.226 3.5x.226 3.5x.226 18x.375* 5x17.5 20x.375* 5x17.5 24x.375* 5x17.5 24x.500 6x17.5 FP20 1025 FP20 1027 FP24 1028 FP24 1325 1200 12x.688 12x.688 12x.688 5x.258 5x.258 5x.258 5x.258 5x.258 18x.375* 5x17.5 20x.375* 5x17.5 24x.375* 6x17.5 26x.500 6x17.5 FP20 1223 FP20 1222 FP24 1325 FP26 1426 1500 12x.844 12x.844 12x.844 5x.258 5x.258 5x.258 5x.258 5x.258 24x.375* 6x17.5 26x.375* 6x17.5 26x.375* 6x17.5 24x.688 6x17.5 FP24 1323 FP26 1325 FP26 1426 FP24 1429 1800 12x.844 12x.844 12x.844 4x.337 4x.337 4x.337 4x.337 4x.337 24x.375* 6x17.5 26x.375* 6x17.5 26x.500 6x20.4 24x.969* 6x20.4 FP24 1325 FP26 1427 FP26 1426 FP26 1530 - INDICATES FOUNDATION PEDESTAL TYPE. - MEMBER SIZE SHOWN WAS SELECTED BASED ON AVAILABILITY OF STD., XS, OR XXS PIPE. IF AVAILABLE, THE SAME NOMINAL DIAMETER PIPE WITH THE NEXT THINNER WALL THICKNESS, AS PER ASTM A53-90b, MAY BE USED, EXCEPT PROVIDE MINIMUM WALL THICKNESS OF " FOR COLUMNS AND CHORDS. - SEE GENERAL NOTE 11 ON SHEET 1. - COLUMN BRACING MEMBERS ARE ST SHAPES, UNLESS NOTED OTHERWISE. SECTION DESIGNATION INDICATES MEMBER DEPTH (DP)x WEIGHT PER FOOT (WT). NOTE: FOR DESIGN TABLE NOTES, SEE SHEET 5. COMMONWEALTH OF PENNSYLVANIA DEPARTMENT OF TRANSPORTATION BUREAU OF PROJECT DELIVERY OVERHEAD SIGN STRUCTURES 4 POST 4 CHORD TRUSS SPANS FROM 100’ TO 200’ DESIGN TABLES LOADING TYPE 2 RECOMMENDED AUG. 31, 2012 CHIEF BRIDGE ENGINEER RECOMMENDED AUG. 31, 2012 ACTING DIR, BUR. OF PROJECT DELIVERY SHT. 7 OF 7 BD-645M
© Copyright 2026 Paperzz