Architect Gelfand Partners A R C H I T E C T S 165 Tenth Street , Suite 100 San Francisco, CA 94103 Tel. 415. 346 . 4040 Fax 415. 346 . 4103 www. gelfand-partners.com REMOVE & REINSTALL RAIL 7 NORTH EAST PAINT ELEVATION 6 REPLACE PLYWOOD SIDING TO MATCH SOUTH EAST PAINT ELEVATION SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" CHILDREN'S CENTER EAVES TYP. PT-1 SOUTH WEST PAINT ELEVATION 5 4 SCALE: 1/4" = 1'-0" (E) WEST ENTRY PAINT ELEVATION 3 SCALE: 1/4" = 1'-0" 2 NORTH WEST PAINT ELEVATION SCALE: 1/4" = 1'-0" CABINETS, PAINTS EAST COVERED PAINT ELEVATION PAINT BATTEN AT LEFT SCALE: 1/4" = 1'-0" MERRITT COLLEGE CHILDRENS CENTER REMOVE SIGN AND BACKING, PATCH HOLES Oakland, CA Drawing Record Issue/ Submission BID SET DATE 07/28/2016 (N)STEEL BAR GATE 1 TYPICAL FENCE PAINT ELEVATION SCALE: 1/4" = 1'-0" Project MATERIAL LEGEND MATERIAL KEY NAME MATERIAL TYPE MANUFACTURER PRODUCT NO. PT-1 LEMON CHIFFON PAINT- EXTERIOR BENJAMIN MOORE OC-109 PT-2 TEAL TONE PAINT- EXTERIOR BENJAMIN MOORE 663 PT-3 ELECTRIC SLIDE PAINT- EXTERIOR BENJAMIN MOORE 404 PT-4 VANDERBERG BLUE PAINT- EXTERIOR BENJAMIN MOORE 721 PT-5 TANGERINE MELT PAINT- EXTERIOR BENJAMIN MOORE 091 PT-6 PMS COLOR-293 COLOR MATCH BENJAMIN MOORE N/A REMARKS MERRITT COLLEGE Childrens Center [GPA PROJECT #1607.00] GATE Sheet NOTES: 1. PAINT COLOR FOR INTERIOR WALLS TO BE PT-1, UNLESS OTHERWISE NOTED. 2. INTERIOR DOOR AND WINDOW TRIM TO BE PAINTED PT-5, UNLESS OTHERWISE NOTED. 3. ALL EXTERIOR TRIM AND STOREFRONTS TO BE PAINTED PT-10, UNLESS OTHERWISE NOTED. 4. ALL INTERIOR DOORS TO BE PAINTED PT-3, EXCEPT BATHROOM DOORS. WC DOORS TO BE PAINTED PT-5. 5. ALL EXTERIOR DOORS, TO BE PAINTED PT-12, UNLESS OTHERWISE NOTED. 6. MEN AND WOMEN BATHROOMS CEILING AND WALLS ABOVE TILE TO BE PAINTED PT-3. 7. KITCHEN CEILING AND WALLS TO BE PAINTED PT-1. 8. CHILDREN RESTROOM CEILING TO BE PAINTED PT-1. PAINT PLANS AND ELEVATIONS A7.01 Sequence PLOT DATE: All ideas, design arrangements and plans indicated or represented by this drawing are owned by, and are the property of Gelfand Partners Architects, Incorporated and were created, evolved, and developed for use on and in connection with this project. None of such ideas, arrangements, or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Gelfand Partners Architects Incorporated.Filing of these drawings or specifications with any public agency is not a publication of the same. No reproduction is therefore permissible without the written consent of Gelfand Partners Architects.
© Copyright 2026 Paperzz