e e LDL CHOLESTEROL, AU400/AU400 /AU640/AU640 Application LDL CHOLESTEROL, AU600 Application System Reagent: OSR6x96 System Reagent: OSR6x96 Reagent ID: 096 Specific Test Parameters General LIH ISE Test Name: Sample: Reagents: Specific test parameters Range LDL-c Volume R1 Volume R2 Volume Wavelength: Method: Reaction slope: Measuring Point 1: Measuring Point 2: Linearity : No Lag Time: Reagent ID: 096 ∇ Test No < 2 200 66 Pri. 540 END + First 0 First 0 Type: > μL μL μL Dilution Dilution Dilution ∇ ∇ ∇ Sec. 0 0 0 μL μL μL 660 ∇ Last Last 27 10 % ∇ Serum ∇ Operation: Pre-Dilution Rate: 1 Min OD L Reagent OD limit: First L -0.1 Last L -0.1 Dynamic Range: L 7.0* Correlation Factor: A 1 On-board stability period: Yes ∇ Max OD H First H Last H H 0.1 0.1 400* B # Test name LDL-c Sample vol. Reagent 1 vol Reagent 2 vol 2 200 66 Dil. vol Dil. vol Dil. vol Wave Method Reaction Point 1 Point 2 540 Sub 0 0 Lst Lst Main Fst Fst Sample type ∇ 0 0 0 μl μl μl 660 END + 27 10 ∇ ∇ ∇ Ser Page 1/2 ∇ Min. OD L Reagent OD limit Fst. L -0.1 Lst. L -0.1 Dynamic range L 7.0* Correlation factor Max. OD H Sample Pre-dil. 0 Linearity Fst No lag time 30 % Sec % ∇ On-board stability period Fst. H Lst. H 0.1 0.1 H A B Rate 400* 1 0 ¤ 30 Select using Space key, or select from list displayed by Guide key Specific Test Parameters General LIH ISE Test Name: Test No Range LDL-c ∇ Value/Flag: # ∇ Normal Ranges: Age L Sex Year 1. # # ο ∇ 2. # # ο ∇ 3. # # ο ∇ 4. # # ο ∇ 5. # # ο ∇ 6. # # ο ∇ 7. None Selected 8. Out of Range < Level L: # Serum Level H: Age H Year # # # # # # Month # # # # # # L Panic Value: Type: > Month # # # # # # # Unit: H # # # # # # # # mg/dL* # Value/flag Normal range Sex 1 # ∇ 2 # ∇ 3 # ∇ 4 # ∇ 5 # ∇ 6 # ∇ 7 Non select 8 Out of range # L # # # # # # # # H # ∇ Decimal places: Test name # # # # # # Age Y Y Y Y Y Y LDL-c # ∇ # # # # # # M M M M M M Sample type ∇ Ser L # # # # # # Age Y Y Y Y Y Y H # # # # # # M→ M→ M→ M→ M→ M→ Panic value # Page 2/2 ∇ Level L # L # # # # # # # # L # Level H # H # # # # # # # # H # Select the function using the Function key or the Mouse Calibration specific Calibration Specific General ISE Test Name: Test No LDL-c Calibration Type: Point 1: Point 2: Point 3: Point 4: Point 5: Point 6: Point 7: Cal. No. # 1-Point Cal. Point: MB Type Factor: AB ∇ < ∇ Formula: OD Type > Y=AX+B CONC † ο ∇ Serum Counts: Factor/OD-L 410* Process: CONC ∇ Factor/OD-H 690* With CONC-0 Calibration Stability Period: Test name Cal type 8 Formula 1 Selection calibrator Cal No Point 1 # ∇ Point 2 ∇ Point 3 ∇ Point 4 ∇ Point 5 ∇ Point 6 ∇ Point 7 ∇ 1-point cal. point MB type factor Calibrator stability period ∇ # # 7 LDL-c ∇ AB ∇ Y=AX+B OD ∇ Conc † Count Process Factor/OD-L 410* 7 Select the function using the Function key or the Mouse # User defined ¤ Analyser default value † LDL Cholesterol Calibrator Cat. No.: ODC0024 * Values set for working in mg/dL. To work in SI units (mmol/L) divide by 38.7 # User defined † LDL Cholesterol Calibrator Cat. No.: ODC0024 * Values set for working in mg/dL. To work in SI units (mmol/L) divide by 38.7 BSSA6196.01 2009-08 # Conc Factor/OD-H 690* ∇ LDL CHOLESTEROL, AU2700/AU5400 Application LDL CHOLESTEROL, AU680/AU480 Application System Reagent: OSR6x96 Specific Test Parameters General LIH ISE Test Name: Sample: Reagents: Wavelength: Method: Reaction slope: Measuring Point 1: Measuring Point 2: Linearity : No Lag Time: ∇ 2 200 66 Pri. 540 END + First 0 First 0 LIH Type: > μL μL μL Dilution Dilution Dilution 0 0 0 μL μL μL ∇ ∇ ∇ Sec. 660 ∇ Last Last 27 10 % ∇ Serum ∇ Operation: Pre-Dilution Rate: 1 Min OD L Reagent OD limit: First L -0.1 Last L -0.1 Dynamic Range: L 7.0* Correlation Factor: A 1 On-board stability period: Yes H ∇ Value/Flag: # ∇ Normal Ranges: Age L Sex Year 1. # # ο ∇ 2. # # ο ∇ 3. # # ο ∇ 4. # # ο ∇ 5. # # ο ∇ 6. # # ο ∇ 7. None Selected 8. Out of Range < Level L: # Serum Level H: Age H Year # # # # # # Month # # # # # # L Panic Value: Type: > Month # # # # # # H # # Unit: 0 30 0 μL Dilution 0 μL R2(R2-1) 66 μL Dilution 0 μL Name Sec. ф LIH # Unit Calibration Type: Point 1: Point 2: Point 3: Point 4: Point 5: Point 6: Point 7: Cal. No. # 1-Point Cal. Point: MB Type Factor: # † * ф AB ∇ < ∇ Formula: OD Type Serum > Y=AX+B CONC † ο ∇ Counts: # Factor/OD-L 410* Calibration Stability Period: Parameters Calibrators General ∇ Last Last ∇ Operation ∇ Yes ∇ mg/dL* ∇ 7 LDL-c Dynamic Range Low Correlation Factor A ∇nm Factor for Maker A 7.0* 1 1 High B B 400* 0 0 30 Day # ∇ +++++ ∇ +++++ ∇ +++++ ∇ Specific Test Parameters Calculated Test Type: Serum Low # # # # # # # # Hour Range ∇ High # Month # # # # # # 0 Panic Value Low # High # # # # # # # # High # # Calibration Parameters STAT Table Calibration ∇ < MB Type Factor: OD Type > Serum ∇ ο Use Serum Cal. Y=AX+B No. of Correction Points Master Curve> Calibrator Point-1 ∇ Point-2 ∇ BSSA6196.01 2009-08 0.1 0.1 Onboard Stability Period LIH Influence Check Lipemia Icterus Hemolysis Max.OD ISE <Point Cal. For User defined LDL Cholesterol Calibrator Cat. No.: ODC0024 Values set for working in mg/dL. To work in SI units (mmol/L) divide by 38.7 AU680 High High > Decimal Places Calibration Specific OD Limit -0.1 -0.1 27 10 < Calibration Type: AB ∇ Formula: <Calibrator Parameters> Calibrator OD Conc Point 1: # † ∇ Point 2: ∇ Point 3: ∇ Point 4: ∇ Point 5: ∇ Point 6: ∇ Point 7 ∇ Point 8 ∇ Point 9 ∇ Point 10 ∇ Factor/OD-H 690* # Serum Range Min.OD Reagent OD Limit First Low Last Low HbA1c LDL-c Test Name: Process: CONC ∇ Advanced Calibration: 660 Value/Flag: # Low ∇ Level # Specificl Ranges: From To Sex Year Month Year # # # # ο 1. ∇ # # # # ο 2. ∇ # # # # ο 3. ∇ # # # # ο 4. ∇ # # # # ο 5. ∇ # # # # ο 6. ∇ 7. No demographics 8. Not within expected values H # # # # # # # # Calibration Specific General ISE LDL-c Noneф 540 ∇nm END ∇ + ∇ 0 0 % ∇ ISE Test Name: Decimal places: Type: > Dilution Parameters General # mg/dL* < μL ∇ μL Common Rgt. Type Wavelength Pri Method Reaction Slope Measuring Point1 First Measuring Point2 First Linearity Limit Lag Time Check 400* ∇ L # # # # # # # # ∇ 2 1 200 Range LDL-c Test Name: LDL-c Sample Volume Pre-Dilution Rate Rgt. Volume R1(R1-1) 0.1 0.1 B Specific Test Parameters Calculated Test HbA1c ∇ Max OD H First H Last H Reagent ID: 096 ISE Test Name: < Specific Test Parameters General LIH ISE Test Name: Parameters General Range LDL-c Volume R1 Volume R2 Volume System Reagent: OSR6x96 Reagent ID: 096 Conc 1-Point Calibration Point Counts: # ∇ ∇ Factor Range Low High Slope Check 410* 690* Allowance Range Check None ∇ ο Reagent Blank ο Calibration Advanced Calibration Operation Yes Interval (RB/ACAL) Use Master Curve OD Range Low High ∇ ∇ ∇ Stability Reagent Blank Calibration ο with Conc-0 ∇ Lot/Lot ∇ ο Lot Calibration 7 7 Day Day 0 0 Hour Hour
© Copyright 2026 Paperzz