2.4 VIEW CONES AND BUILDING HEIGHT The West End Community Plan requires buildings located in Area ‘A’ be restricted at 117.3 metres. Measured from base surface, the north parapet height is limited to 424’-9” (74m) geodetic. An exception for the height limitation is proposed for the elevator overrun and machine room. This will allow elevator access to the level 42 amenity rooms and exterior terrace. The following View Cones cross the proposed 1640-1650 Alberni site; B1, C1, 20, and 3.2.1. At a max geodetic elevation of 133 metres, View Cone 20 (view of Capilano valley and the north shore from Granville Street) is the most restrictive. A view shadow within View Cone 20 increases the allowable height of the project. The proposed exception for the elevator overrun and machine room is below this view cone shadow. Georgia Corridor SITE VIEW CONE 3.2.1 VIEW CONE 20 INCLUDING VIEWCONE SHADOW MAXIMUM COMMUNITY PLAN HEIGHT - 385ft (117.3m) 3.2.1 20 Applicable View Cones 18 Community Height and View Cone Diagram WEST GEORGIA V I E W I M PA C T S T U D Y POTENTIAL FUTURE DEVELOPMENT CONSULATE GENERAL OF THE REPUBLIC OF INDONESIA 8° 71° 14 STOREY RESIDENTIAL LANE 89° 22 STOREY RESIDENTIAL 22 STOREY RESIDENTIAL WEST GEORGIA WEST GEORGIA ROBSON STREET ROBSON STREET 1668 Alberni Balcony Impact Robson Place Impact Floors 1 to 14 14 STOREY RESIDENTIAL POTENTIAL FUTURE DEVELOPMENT CONSULATE GENERAL OF THE REPUBLIC OF INDONESIA 14 STOREY RESIDENTIAL ° 71° LANE 14 STOREY RESIDENTIAL 14 STOREY RESIDENTIAL 50 POTENTIAL FUTURE DEVELOPMENT 5" 3'- 77] 5 R 62 1 [R CONSULATE GENERAL OF THE REPUBLIC OF INDONESIA LANE 89° 22 STOREY RESIDENTIAL CARDERO STREET ALBERNI STREET BIDWELL STREET CARDERO STREET BIDWELL STREET ALBERNI STREET R8 [R24 0'-0" 384 ] 22 STOREY RESIDENTIAL ROBSON STREET Robson Place Impact Floors 15 to 22 POTENTIAL FUTURE DEVELOPMENT CONSULATE GENERAL OF THE REPUBLIC OF INDONESIA 1668 Alberni is 14 storeys with primary orientaiton to the north and south. The building elevation facing the project site is absent of windows. Views from the lane side balconies will be minimally impacted beyond current conditions. 31 ° 2° LANE ° 40 ° 67° 14 STOREY RESIDENTIAL 13 14 STOREY RESIDENTIAL CARDERO STREET 14 STOREY RESIDENTIAL STREET BIDWELL STREET CARDERO ALBERNI STREET 9° BIDWELL STREET ALBERNI STREET 777 Cardero is an existing 21 storey residential tower with primary orientation to the east and west. The view from the corner window in the corner units will be impacted mimimally for the first 14 storeys as the profile of the proposed development is only slightly wider than the profile of the existing structure. ROBSON STREET Separation Strategy 1668 Alberni 777 Cardero - Robson Place 19 2.5 A.1 VIEW CONES AND BUILDING HEIGHT The West End Community Plan requires the height of buildings located in Area ‘A’ of the Georgia Corridor be restricted to below 385 ft (117.3m) above base surface. The project massing is below height restriction with the exception of the elevator overrun. This relaxation of the height requirement is permitted by section 10.11 of the Vancouver Zoning and Development Bylaw. Extending the elevator overrun above the main tower roof allows resident access to the amenity space and terrace on level 42. View Cone 3.2.1 Queen Elizabeth Park to Downtown skyline and North Shore Mountains View Cone 20 is below the top of the proposed tower, however a number of existing buildings shadow the view allowing an increase in height. • Shadow A is created by an existing building at 2410-2418 Granville Street • Shadow B is created by numerous existing towers at the foot of the Burrard bridge. Elevator Overrun relaxation from West End Community plan height restriction View Cone 20 shadow B View Cone 3.2.1 is well above the proposed project massing and does not impact it’s form. 482.05’ (146.93m) view cone 3.2.1 VIEW CONE 3.2.1 441.24’ (134.49m) view cone 20 shadow B VIEW CONE 20 SHADOW B 433’-7” elevator overrun 424.58’ (129.4m) community plan max height 424’-9” roof parapet elevator machine room amenity C0MMUNITY PLAN 481.79’ (146.85m) view cone 3.2.1 West End Community Plan maximum height above base surface for Georgia Corridor Area A. View Cone 20 Granville Street at Broadway to Capilano Valley and North Shore 436.35’ (133m) view cone 20 shadow B 429.04’ (130.7m) community plan max height 415’-9” amenity terrace guard 385’ above base surface community plan max height 385’ above base surface community plan max height 355.02’ (108.2m) view cone 20 VIEW CONE 20 section detail A 353.01’ (107.6m) view cone 20 section A VIEW CONE 20 SHADOWS A.2 View Cone 20 Shadow A Shadow B View Cone 20 Approximate Project Outline approximate view from view cone 20 base point at intersection of Broadway and Granville Streets Shadow A - 2410 Granville Street Shadow B - 1111 + 1133 Beach Ave and 1160 Burnaby View Cone 20 Approximate Project Outline view cone detail image
© Copyright 2026 Paperzz