Analytical balance: Specification: • Max. Weight - 210g, • Readability - 0.0001g • Unit with internal calibration • User Selectable environmental settings • Upfront level indicator for quick easy leveling • Easy to clean draftshield with sliding top & side doors REQUEST FOR QUOTATION Project name: TBCARE II TB CARE II Project funded by USAID is anticipating quotations from the respective vendors based on the below mentioned specification by 27 April, 2012 (sealed quotation is invited) to House #4, Road #18, Apt #B-1, Block: A, Banani, Dhaka: 1213. Item name: Autoclave Origin: US/non US (US brand will get preference) Technical Specification: Details specification Operating temperature range Sterilizer 100-150◦C (0.019-0.21MPa) Heating 45-110◦C (0-0.015MPa) Warming 45-100◦C Maximum Operating pressure 0.25MPa Temperature Display Digital Pressure gauge Display Analog Display range 0-0.4MPa Heat source 3.0-5.0 KW electric heater Protection type against electrical Class I equipment shock Time Display Digital Display range- sterilizing 1-99 hours, 1-999 min (0.019.59,10-99 chargeable) Warming 1-99 hours, 4 hours (Changeable) Pressure chamber type PED Category (g) Chamber dimensions 370X774 mm Chamber capacity Effective internal volume: 65-100 L, Internal volume: 75-100 L Chamber material SUS304 Weight 70-100 kg Rated voltage 230V AC Power input 13A Required power supply Single phase 230 V AC 950/60 Hz) 15A or more Power consumptions 3.0 KW Accessories Stainless baskets-2 with other accessories Additional requirements: Control unit Air filter Re cooling system Wire baskets Warranty Servicing Control unit for fully automated process control, sterilization of liquids, including temperature probe Exhaust air filtration system for autoclave Autoclave re cooling system to shorten the time of liquid sterilization Wire baskets with drip tray Three years Three years Bench Top pH Meter with pH Electrode and Buffer Solutions (pH 4.01 and pH 7.00) Origin: USA INCLUDING Calibration Buffer Solution: 1. pH Buffer 4.01 Color-Coded Red (NIST), 500 mL/container 2. pH Buffer 7.00 Color-Coded Yellow (NIST), 500 mL/container Product Features: Fast, easy to calibrate Requires minimal keystrokes and measures pH, millivolt potential and temperature Product Specifications: Range: pH: -2.00 to19.99 mV: 2000mV Temp: -10.0°C to 110.0°C Resolution: pH: 0.1; 0.01; 0.001 (selectable) mV: 0.1 mV Temp: 0.10C Accuracy: pH: 0.002 mV: 0.2 or 0.1% mV Temp: 0.30C at 0-700C; 1.00C at 70-1100C Calibration points: 1,2 or 3 (1 uses previous calibration slope and adjust offset; 2 & 3 create new slope) Calibration Review: User activated; Shows last cal slope, Buffers/standards used & mV in each standard Buffer recognition: Auto;4.01, 6.86, 7.00,10.01 Class II type A2 Bio Safety Cabinet, 5 feet Gas tap, Double outlet power point (220V, 50Hz,) Fluorescent and Germicidal lamp (UV lamp) facility Floor stand for the BSC Real time air flow monitoring facility Provision for Lo-Flow Audible Alarm Performance: NSF/ANSI 49 certification. Window type: vertically sliding type. Must provide service, operating manual, details of decontamination and validation procedure Operating Power: 220 V, 50 Hz Installation: Supplier should install and demonstrate operation satisfactorily. Warranty: Minimum one year from the date of installation including spares, labor and transport etc. Item name: Centrifuge (Refrigerated) Country of origin: USA Details Specification: 1. Interchangeable swing bucket and high-speed fixed angle rotors 2. Accommodate capacities up to 16 X 50 ml conical (Falcon ® ) or 16 x 15 ml conical (Falcon ® ) tubes per run. 3. Spin up to 14,000 rpm, or 20,800 x g or more 4. Low-profile access height for easy sample loading 5. Automatic rotor recognition senses rotor type to set maximum allowable speed—ensures safety 6. Fast, simple programming of time, temperature (refrigerated models), speed/ g-force and radius value 7. Adjustable-speed Short Spin button 8. Speed, g-force and radius correction values can be entered 9. Values can be changed during centrifugation 10.Temperature range from –10 °C to 40°C, with Fast Temp function for rapid cooling of the centrifuge chamber 11.Standby cooling maintains temperature when not in use 12.Selectable program memory for individual user programs Accessories: 1. Centrifuges rotor-2 pcs 2. Centrifuge rotor buckets-2 pcs 3. Aerosol tight lids for rotor buckets- 8 pcs 4. Reducing adapter for 50 ml centrifuge tubes-12 pcs 5. Reducing adapter for 15 ml/12 ml centrifuge tubes-8 pcs Specification for electric microincineration: Origin: USA Most suitable for the sterilization of inoculation loops, needles and instruments Ideal for laboratories and safety cabinets where the use of gases and open flames is not permitted Falcon tube: 50 ml capacity Specification: • Approximate dimensions: 30 mm O.D.; 115 mm length • Sterilized by gamma irradiation and non-pyrogenic • Dark blue printed graduations and white writing patch • Polyethylene flat-top screw cap allows one hand manipulation and provides a level writing area • Modified polystyrene offers improved stress resistance General-Purpose Laboratory Refrigerators Specification: • • • • • Temperature range: -3° to +10°C Capacity: 21 cu ft So shelves: 4 No doors: 1 glass door Exterior dimensions: 29.1” x 31.7” x 79.4” HOT AIR OVEN: Origin: USA 1. Interior Volume: 199 Liter 2. Shelves: Max capacity- 17, Standard supply-2 3. Operating temperature: Ambient temp.+20°c up to 250°c 4. Easy to operate with natural convection & air circulation drying option to meet general drying needs 5. Short process & heat up times & precise heat control to 250°c 6. Temperature regulation by precise Kelvitron microprocessor based controller with large eye level display 7. Interchangeable silicone door gasket, removable shelf support & rounded corner for easy cleaning 8. Power: 220 volt, 50/60 hertz 9. Must be US brand CODE NUMBER NAME OF EQUIPMENT: Precision Incubator for culture Tender specifications MANUFACTURER: Quantity: Type / Model Country of Origin MAIN SPECIFICATIONS: Chamber made of stainless steel, easy to clean Housing preferably stainless steel or at least durable corrosion-resistant coating of metal used (e.g. galvanized sheet metal coated with epoxy, hardened by heat treatment) Double doors, double lock Inner glass doors Volume of interior housing ≥ 600-800 L ˜ Designed specially for temperatures up to +70 °C, optimised for living cultures at 37 °C Temperature variation at +37 °C <± 0.1 °C Temperature overshoot within this limit Temperature range +30 °C (at least 5 °C above ambient temperature) to +70 °C Adjustable overtemperature protection controller TWW protection class 3.1 or electronic temperature limiter TWB protection class 2 Uniformity of temperature inside in the chamber (deviation <± 0.2 °C) Two high grade temperature sensors (class A) with mutual monitoring and taking over performance at same working temperature Integrated programmable timer for tempering profiles Programmes stored on power failure Adjustable air flap for preheated fresh air intake Vent connection with restrictor flap Simultaneous indication/display of temperature, weekday, time and ramp segment information Bidder’s Specification* Alarm (audible/visible) if desired temperature is exceeded Function signals for operating mode Long term logging (ring store) internal memory to save temperature and error states, with time stamp to the minute, GLP-conforming Serial RS 232 interface with software for read out of data with PCL3-compatible printer Electric needs Power supply voltage: AC 230 ± 10V, 50 Hz, European plug** Consumption: approx. 2.000 W, when heating Protection class: DIN/EN 60529/or county specific Circuit radio interference free in accordance with EN 55 014/ or country specific norms GLP conforming documentations, programmes, storage, serial interface RS 232 Manufacturer’s Certificate: Manufacture’s calibration certificate for +37 °C Quality and Safety standards met by the product offered have to be listed Accessories: One or two additional perforated stainless steel shelves, non-tipping, if needed to match four shelves per incubator Operation and Maintenance Manual: Operation/Maintenance/Service manuals, at least one set each, in English and languages have to be provided for each unit delivered Installation and Maintenance: Each bidder has to install the delivered equipment through certified/ qualified engineers. The detailed installation prerequisites have to be communicated to the purchaser in advance. A detailed instruction of the laboratory personnel on use, function and maintenance of the equipment (user training) as well as a comprehensive maintenance plan is part of this procurement Standard Maintenance Tools:*** Spare Parts: A set of fuses, if used in the incubator to protect regulation Packing data:**** Net weight Gross weight: Dimensions (W x H x D) in cm Appliances must be transported upright (Y/N) Costumers Tariff Number Warranty: 2 years on regulation, 5 years o heating coils Remarks: The design and workmanship of equipment offered, including power supply, has to be suited to operate properly and continuously under the climatic conditions in the purchaser’s country. Especially humidity, growth of fungi, thunder storms and possible spikes in the electric network will have to be taken into consideration. For longer storage an appropriate packing should be provided on delivery Each bidder may propose any system / product better than the requirements listed above ˜ Volume needs to be adjusted. In a volume of about 600 L approximately 2.000 slants of standard size (tubes with a diameter of 16 – 18 mm and a length of 125 – 150 mm) can be incubated (9 racks with 60 tubes per shelve, 4shelves). This means an incubator of this size is suited for about 1.000 specimens to be cultured per month, if only one slant is inoculated per specimen and for 500 samples per month if two slants are inoculated per specimen. * NA if not applicable * * Needs to be adjusted to the voltage and/or plugs used or available inside the country. *** This could be a standard text (if applicable) like: ”All standard accessories, consumables, parts required for the proper operation and all standard tools, cleaning and lubrication material shall be included in the offer. Each bidder has to specify the quantities in its offer of every item or items not specified above. Consumables should be calculated for at least 3 years (can be adjusted) **** Packing data are not necessarily part of the bidding process, but if shipment is arranged by the country (NGO), these data are needed for shipment papers and customs declaration Magnetic stirrer: Specification: • Ceramic coated heating plate • Instant on operation • Built-in control for heating and stirring • Temperature: ambient +5 to 550ºC • Speed: 60 – 1200rpm • Size: 4 x 4”, 7 x 7”, 10 x 10” MICROPIPETTE Origin: USA Capacity: 10-100 µl Capacity: 100-1000 µl Capacity: 1-5 ml NAME OF EQUIPMENT: CODE NUMBER Online UPS with battery pack for BSC delivered Tender specifications Quantity: MANUFACTURER: Type / Model Country of Origin Description of function: MAIN SPECIFICATIONS: UPS microprocessor controlled, line interactive, on line continuous transducer, 20 min. Booster function to regulate up voltage brake down to 170 V (to safe battery) Buck function to regulate down voltage increase up to 280 V Filter to protect against voltage spikes Protection against overload and short circuit Advanced battery check for automated periodic battery inspection Indicators for status like normal function, net down, working on battery, loading battery, battery capacity Sleep mode if consumer is shut off Power rating: 1500/900 VA/W (needs to be adjusted to the consumption of the BSC offered/delivered, e.g. 2000/1200) Power: 230 V +/- 25%, 50 Hz or 60 Hz (+/10%) with automatic recognition Battery, maintenance-free, automatic shut off before reaching complete decharge? Time for recharging: approx. 4 hours to reach at least 90% of total capacity Outlet voltage: Sine, 230V +/- 3%, 50 or 60 Hz +/- 0.5% Changeover time: <5 msec Bidder’s quoted* Specifications Efficiency coefficient approx. 98%, on battery >85% Noise at 1 m distance < 48 dB[A] Permissible ambient temperature/relative humidity: 0 – 40 °C/≤95 % (not condensing) VI according to IEC 62040-3 Electric needs Supply voltage: 230 ± 10 ACV, 50 Hz, European plug** Consumption: approx.1500 W (depending on the model chosen Protection class: EN 60529/or county specific Protection: IP 20 Circuit radio interference free in accordance with EN 55 014/ or country specific norms Manufacturer’s Certificate shall be specified and provided for each item supplied Quality and Safety standards met by the product offered have to be listed Accessories: Battery pack to ensure operating of the BSC for at least 20 minutes after power blackout Connection (cable and fittings) for battery pack Operation and Maintenance Manual: Operation/Maintenance/Service manuals, at least one set, in English and XYZ languages have to be provided for each unit delivered Installation and Maintenance: Each bidder has to install the delivered equipment through certified/ qualified engineers. The detailed installation prerequisites have to be communicated to the purchaser in advance. A detailed instruction of the laboratory personnel on use, function and maintenance of the equipment (user training) as well as a comprehensive maintenance plan is part of this procurement Standard Maintenance Tools:*** Spare Parts: Packing data:**** Net weight Gross weight Dimensions (W x H x D) in cm Appliances must be transported upright (Y/N) Costumers Tariff Number Warranty: Warranty: >2 years on UPS, >5 years for battery pack Remarks: The design and workmanship of equipment offered, including power supply, has to be suited to operate properly and continuously under the climatic conditions in the purchaser’s country. Especially humidity, growth of fungi, thunder storms and possible spikes in the electric network will have to be taken into consideration. For longer storage an appropriate packing should be provided Each bidder may propose any system / product better than the requirements listed above * NA if not applicable * * Needs to be adjusted to the voltage and/or plugs available or used inside the country. Plugs inside an instrument may dependent on the country from which the equipment is purchased. Plugs inside the BSC may differ from its main connection to the electric net (e.g. Vortex to be used in a BSC can only be connected trough the plugs inside the BSC). Therefore a well prepared and coherent set of specification documents has to be prepared and submitted. *** This could be a standard text (if applicable) like: ”All standard accessories, consumables, parts required for the proper operation and all standard tools, cleaning and lubrication material shall be included in the offer. Each bidder has to specify the quantities in its offer of every item or items not specified above. Consumables should be calculated for at least 3 years (can be adjusted) . **** Packing data are not necessarily part of the bidding process, but if shipment is arranged by the country (NGO), these data are needed for shipment papers and customs declaration Specification of Inspissator Origin: US/Non US Quantity: 02 Name of heading Name of the item Type Dimensions Power Capacity Rack Details Coagulator (inspissator) for Lowenstein-Jensor Waterbath model for universal bottles 1040 X 600 X 380 mm (approx.) 1500 W 162 universal containers 01 TECHNICAL SPECIFICATION 1. HOT AIR OVEN: Origin: USA 1. Interior Volume: 199 Liter 2. Shelves: Max capacity- 17, Standard supply-2 3. Operating temperature: Ambient temp.+20°c up to 250°c 4. Easy to operate with natural convection & air circulation drying option to meet general drying needs 5. Short process & heat up times & precise heat control to 250°c 6. Temperature regulation by precise Kelvitron microprocessor based controller with large eye level display 7. Interchangeable silicone door gasket, removable shelf support & rounded corner for easy cleaning 8. Power: 220 volt, 50/60 hertz 9. Must be US brand 2. WATER DISTILLATION PLANT Origin: USA ACCESSORIES INCLUDED: 1. Pretreatment Kit 2. Pretreatment Cartridge/Mixed Bed Product Features: Distillation process increases water purity to above 1 megohm-cm. Patented vapor trap eliminates carry-over of vapor-borne contaminants. Glass components eliminate the leaching of impurities. Fully automatic microprocessor controls simplify operation and cleaning, while assuring high reliability. 24-hour automatic control activates still as required to maintain a full reservoir. Automatic drain cycle in tap feed models reduces cleaning frequency. Thermistor and heat sensor offer double protection against low water conditions. For convenience, unit is designed with capabilities for tap or pretreated feedwater. Space-saving design; wall or bench mounted. Automatic start/stop feature when connected to FI-Streem tank or using float switch provided. Pretreatment Kit: FI-Streem deionizers are a simple pretreatment system for FI-Streem III glass stills. The use of pretreated water increases purity and decreases cleaning. Utilizes disposable cartridges for removal of organics and inorganic. Visual “Go/No Go” indicator alerts operator when cartridge replacement is necessary. Product Specifications: Capacity: 4 Liters/hour Cooling Water: 120 LPH Maximum Pressure: 80 psig / 5.6 kg/cm2 Minimum Pressure: 15 psig / 1.1 kg/cm2 Feed Water Type: Tap/Pretreated No. of Heater: 4 TOC in Produced Water: < 5 ppb Flow Rate: </= 800 ml/min Pressure: 30-80 psig Inlet Water Temperature: 1°C to 35°C Overall Dimensions (W×H×D): 30.5×46.0×48.3 cm Power: 240 Volt; 50/60 Hz; 30 Amps 3. MICROPIPETTE Origin: USA Capacity: 10-100 µl Capacity: 100-1000 µl Capacity: 1-5 ml 4. Bench Top pH Meter with pH Electrode and Buffer Solutions (pH 4.01 and pH 7.00) Origin: USA INCLUDING Calibration Buffer Solution: 1. pH Buffer 4.01 Color-Coded Red (NIST), 500 mL/container 2. pH Buffer 7.00 Color-Coded Yellow (NIST), 500 mL/container Product Features: Fast, easy to calibrate Requires minimal keystrokes and measures pH, millivolt potential and temperature Product Specifications: Range: pH: -2.00 to19.99 mV: 2000mV Temp: -10.0°C to 110.0°C Resolution: pH: 0.1; 0.01; 0.001 (selectable) mV: 0.1 mV Temp: 0.10C Accuracy: pH: 0.002 mV: 0.2 or 0.1% mV Temp: 0.30C at 0-700C; 1.00C at 70-1100C Calibration points: 1,2 or 3 (1 uses previous calibration slope and adjust offset; 2 & 3 create new slope) Calibration Review: User activated; Shows last cal slope, Buffers/standards used & mV in each standard Buffer recognition: Auto;4.01, 6.86, 7.00,10.01 WATER DISTILLATION PLANT Origin: USA ACCESSORIES INCLUDED: 1. Pretreatment Kit 2. Pretreatment Cartridge/Mixed Bed Product Features: Distillation process increases water purity to above 1 megohm-cm. Patented vapor trap eliminates carry-over of vapor-borne contaminants. Glass components eliminate the leaching of impurities. Fully automatic microprocessor controls simplify operation and cleaning, while assuring high reliability. 24-hour automatic control activates still as required to maintain a full reservoir. Automatic drain cycle in tap feed models reduces cleaning frequency. Thermistor and heat sensor offer double protection against low water conditions. For convenience, unit is designed with capabilities for tap or pretreated feedwater. Space-saving design; wall or bench mounted. Automatic start/stop feature when connected to FI-Streem tank or using float switch provided. Pretreatment Kit: FI-Streem deionizers are a simple pretreatment system for FI-Streem III glass stills. The use of pretreated water increases purity and decreases cleaning. Utilizes disposable cartridges for removal of organics and inorganic. Visual “Go/No Go” indicator alerts operator when cartridge replacement is necessary. Product Specifications: Capacity: 4 Liters/hour Cooling Water: 120 LPH Maximum Pressure: 80 psig / 5.6 kg/cm2 Minimum Pressure: 15 psig / 1.1 kg/cm2 Feed Water Type: Tap/Pretreated No. of Heater: 4 TOC in Produced Water: < 5 ppb Flow Rate: </= 800 ml/min Pressure: 30-80 psig Inlet Water Temperature: 1°C to 35°C Overall Dimensions (W×H×D): 30.5×46.0×48.3 cm Power: 240 Volt; 50/60 Hz; 30 Amps
© Copyright 2026 Paperzz