Impact of Placing a Modiolar Array and Slim Straight Array in Opposite Ears of the Same Pediatric Patient Lisa R Park, AuD Joseph Roche, MD Holly FB Teagle, AuD Jennifer Woodard, AuD Craig Buchman, MD University of North Carolina – Chapel Hill Ear and Hearing Center Inherent differences • Smaller electrodes on the 422 resulting in higher impedance. • Electrodes further from nerve resulting in higher T/C levels. • More fluid between electrode and nerve resulting in higher impedance fluctuation. Exaggeration of electrode size and location differences, courtesy of Cochlear Americas. How this impacts the MAP Subjects Subject Etiology/ Risk Factor Stability Age @ 1st CI/ Device Age @ 2nd CI/ Device Time between surgeries 1 Unknown Progressive 3.6 years Freedom CA (AD) 4.9 years CI422 (AS) 15 months 2 Unknown Progressive 7.7 years CI512 (AD) 10.3 years CI422 (AS) 30 months 3 Unknown Progressive 9.6 years CI512 (AS) 11.7 years CI422 (AD) 24 months 4 Unknown (ANSD) Progressive 2.5 years Freedom CA (AD) 6.7 years CI422 (AS) 50 months 5 Unknown Progressive 8.9 years Freedom CA (AD) 10.2 years CI422 (AS) 15 months 6 Connexin 26 & 30 mutations Stable 0.8 years CI422 (AD) 1.1 years Freedom CA (AS) 3 months 7 Waardenburg Stable 1.1 years Freedom CA (AS) 2.8 years CI422 (AD) 20 months 8 Connexin 26 mutation Progressive 3.4 years Freedom CA (AD) 5.1 years CI422 (AS) 20 months 9 Prematurity complications (ANSD) Progressive 2.4 years Freedom CA (AD) 7.6 years CI422 (AS) 61 months Change in residual hearing threshold at 250 Hz Change in residual hearing threshold at 250 Hz Number of Active Electrodes Impedance Fluctuations Impedance Fluctuations Impedance Fluctuation Index (IFI) 2.5 IFI (kohm) 2.0 Contour Device 1.5 CI422 1.0 0.5 0.0 1 2 3 4 5 Subject 6 7 8 9 Impedance Averages Charge Levels Change in NRT Threshold Charge Levels NRT Threshold Charge Levels Power Levels and Battery Life Recorded PBK Scores Recorded PBK Scores 120 % words Correct 100 80 Slim Straight 60 Contour Advance 40 Binaural 20 0 1 2 3 4 5 Subjects 6 7 8 9 Summary Significant Factors: • • • 422 has fewer active electrodes at surgery and at 6 months. All of the contour electrodes were active at surgery and 6 months NRT was lower at post op than in the OR for both devices and NRT for the Contour was significantly lower than the 422. Impedance values fluctuate more and are higher in slim straight devices than contour advance devices. Non-Significant Factors: • • • • • T values, C values, or dynamic range The change in NRT threshold from OR to postop The change in residual hearing at 250 Hz despite differences in surgical approach. Battery life or power levels. Recorded PBK Scores
© Copyright 2026 Paperzz