Technical Specification FLUXUS® F401 H2O Ultrasonic Measurement of Water Flow Portable, high accuracy, non-intrusive flow measurement Features • Non-intrusive flow measurement with high measuring accuracy for portable use • Precise bi-directional, highly dynamic flow measurement • Water-tight transducers (IP68) are characterised by their high robustness • User-friendly menu navigation - the firmware is specifically adapted to the needs of the water industry For nominal diameters of 25 to 3100 mm and for flow velocities of 0.01 to 25 m/s • Digital signal processor (DSP) and signal processing ensure stable and reliable results even under difficult measurement conditions • High measuring accuracy, even at low flow velocities • Adherence to AWWA manual M36 FLUXUS F401 H2O Applications • Water and wastewater applications • Clean measurement process for drinking water systems • Leak detection • Water loss balancing • Verification of sewage lift station performance • Temporary monitoring of distribution and collection systems • Verification of pump and valve performance TSFLUXUS_F401V1-0US_Lusm, 2014-06-30 FLUXUS F401 H2O with transducers 1 FLUXUS® F401 H2O Technical Specification Flow Transmitter Technical Data FLUXUS design F401 portable device for water flow measurement measurement measurement principle flow velocity resolution repeatability medium transit time difference correlation principle 0.01 to 25 m/s 0.025 cm/s 0.25 % of reading ±0.01 m/s water and acoustically similar liquids with < 6 % gaseous or solid content by volume accuracy1 - volumetric flow rate flow transmitter power supply battery power consumption number of flow measuring channels signal attenuation measuring cycle response time housing material degree of protectionaccording to IEC/ EN 60529 dimensions weight ambient temperature display menu language measuring functions physical quantities totalizer data logger loggable values capacity communication interface ±2 % of reading ±0.01 m/s 100 to 240 V/50 to 60 Hz (power supply unit), 12 V DC (socket at transmitter), integrated battery, external battery (optional) 12 V DC, 26 Ah Li-Ion operating time (without outputs and backlight): > 20 h <6W 1 0 to 100 s, adjustable 10 Hz 1s PP IP67 273 x 247 x 127 mm 2.9 kg -10 to +50 °C 2 x 16 characters, dot matrix, backlight English, German, French, Dutch, Spanish volumetric flow rate, mass flow rate, flow velocity volume, mass all physical quantities and totalized values > 100 000 measured values - process integration (optional, without outputs): RS485 (emitter) or Modbus RTU or BACnet MS/TP - diagnosis: RS232/USB serial data kit (optional) software (all Windows™ versions) сable adapter accessories (optional) output adapter outputs (optional) number range accuracy active output - FluxData: download of measurement data, graphical presentation, conversion to other formats (e.g. for Excel™) RS232 RS232 - USB for outputs or for process interface The outputs are galvanically isolated from the transmitter. current output 1 0/4 to 20 mA 0.1 % of reading ±15 μA Rext < 500 Ω binary output 1 32 V/200 mA number optorelay binary output as alarm output - functions limit or error binary output as pulse output - pulse value 0.01 to 1000 units - pulse width 80 to 1000 ms 1 2 for reference conditions and v > 0.25 m/s TSFLUXUS_F401V1-0US_Lusm, 2014-06-30 Technical Specification FLUXUS® F401 H2O Connection A B D C transducers outputs power supply unit/ battery charging unit or battery adapter and external battery output adapter outputs pin A B C D outputs binary output (+) binary output (-) current output (+) current output (-) TSFLUXUS_F401V1-0US_Lusm, 2014-06-30 RS485, Modbus, BACnet A (+) B (-) shield 3 FLUXUS® F401 H2O Technical Specification Transducers Technical Data MHz 0.5 2 mm mm mm 100 200 3100 25 50 200 mm mm - - PEEK with stainless steel cap 316Ti PEEK IP681 PEEK with stainless steel cap 316Ti PEEK IP681 m 2550 12 2550 12 mm mm mm 130 54 83.5 72 32 46 h h transducer frequency inner pipe diameter d min. extended min. recommended max. recommended pipe wall thickness min. max. material housing contact surface degree of protection according to IEC/ EN 60529 transducer cable type length dimensions length l width b height h dimensional drawing l b b l ambient temperature min. °C -40 max. °C +100 1 test conditions: 3 months/2 bar (20 m)/20 °C -40 +100 Transducer Cable type ambient temperature properties cable jacket material outer diameter thickness color shield 4 °C mm mm 2550 -40 to +100 longitudinal water tight PUR 5.2 ±0.2 0.9 gray x TSFLUXUS_F401V1-0US_Lusm, 2014-06-30 Technical Specification FLUXUS® F401 H2O Transducer Mounting Fixture ladder chain mounting accessory material: 316 chain length: 0.75/2 m Coupling Materials for Transducers type coupling compound type N coupling pad type VT order code 990739-1 990739-0 990739-14 TSFLUXUS_F401V1-0US_Lusm, 2014-06-30 ambient temperature °C -30 to +130 -10 to +200 material mineral grease paste fluoroelastomer transducer 0.5 MHz 2 MHz 5 FLUXUS® F401 H2O FLEXIM AMERICAS Corporation Edgewood, NY 11717 USA 6 Technical Specification internet: www.flexim.com e-mail: [email protected] 1-888-852-7473 Tel.: (631) 492-2300 Subject to change without notification. Errors excepted. Fax: (631) 492-2117 FLUXUS® is a registered trademark of FLEXIM GmbH. TSFLUXUS_F401V1-0US_Lusm, 2014-06-30
© Copyright 2026 Paperzz