PA 348 - 06/1 Cuvette-Test LCK 348 Page 1 Programming instructions CADAS 100 LPG ≥ 210 Phosphate-Phosphorus Edition 01/06 ortho and total Attention! The edition date of this programming instruction must be identical to the edition date of the instruction attached to the reagents. This is the only way to ensure that your instrument will be programmed with the correct data. Please note! If you make an error during programming, you can cancel the last entry by pressing the key ➞ on the keyboard. and L indicate the right and left ➞ ➞ ➞ The input symbols R keys respectively. Programming of LCK 348 Phosphate-Phosphorus Select the program PRG (programming of a test, see page 1 and 2) or Select the program VAR (variation of a test, see page 3 and 4). Phosphate-Phosphorus (PO4-P) (Program PRG) Program number: for example 1 Symbol: L 348 L 1 W: λ = Factor: 1 = 2 3 STA FPRG ... nm ➞ Pro: E ▼ 4- L PO L ➞ Name: ➞ Input via keyboard ➞ Display P Press the function key below 1 850 6.47 mg L Measuring limit: yes no / X ➞ -0.054 Unit: ➞ Constant: R l Press function key below yes Lower limit: 0.5 Upper limit: 5.0 Programming of LCK 348 Phosphate Select the program PRG (programming of a test, see page 1 and 2) or Select the program VAR (variation of a test, see page 3 and 4). Phosphate (PO4) (Program PRG) Display Input via keyboard Program number: for example 1 ➞ L Name: PO L 348 ➞ Symbol: Pro: 1 W: λ = Factor: 1 = 2 ... nm 3 STA FPRG Press the function key below 1 850 19.84 Unit: mg L yes no / X ➞ -0.146 ➞ Constant: Measuring limit: ▼ 4 R l Press function key below yes Lower limit: 1.5 Upper limit: 15.0 All data entries are documented on the printer; their transfer to storage is confirmed by the printer message »stored«. You should check the printed data to ensure that all entries are correct. PA 348 - 06/1 Cuvette-Test LCK 348 Page 2 Programming instructions CADAS 100 LPG ≥ 210 Phosphate-Phosphorus Edition 01/06 ortho and total Attention! The edition date of this programming instruction must be identical to the edition date of the instruction attached to the reagents. This is the only way to ensure that your instrument will be programmed with the correct data. Please note! If you make an error during programming, you can cancel the last entry by pressing the key ➞ on the keyboard. and L indicate the right and left ➞ ➞ ➞ The input symbols R keys respectively. Programming of LCK 348 Phosphorus-pentoxide Select the program PRG (programming of a test, see page 1 and 2) or Select the program VAR (variation of a test, see page 3 and 4). Phosphorus-Pentoxide (P2 O5 ) (Program PRG) Program number: for example 1 Symbol: L 348 L 1 W: λ = Factor: 1 = 2 ... nm 3 STA FPRG O L ▼ 5 Press the function key below 1 850 14.83 mg L yes no / X ➞ -0.107 Unit: ➞ Constant: Measuring limit: ▼ 2 L ➞ Pro: P ➞ P L ➞ Name: ➞ Input via keyboard ➞ Display R l Press function key below yes Lower limit: 1.2 Upper limit: 11.5 All data entries are documented on the printer; their transfer to storage is confirmed by the printer message »stored«. You should check the printed data to ensure that all entries are correct. PA 348 - 06/1 Programming instructions CADAS 100 LPG ≥ 210 Phosphate-Phosphorus Cuvette-Test LCK 348 Page 3 ortho and total Edition 01/06 Attention! The edition date of this programming instruction must be identical to the edition date of the instruction attached to the reagents. This is the only way to ensure that your instrument will be programmed with the correct data. Please note! If you make an error during programming, you can cancel the last entry by pressing the key ➞ on the keyboard. Programming of LCK 348 Phosphate-Phosphorus Select the program VAR. Select function key below symbol »348 E«. Phosphate-Phosphorus (PO4-P) (Program VAR) Display Input via keyboard Program number: for example 1 Symbol: 348 E Name: PO4 - P LCK 348 E Pro: 1 3 STA FPRG Press function key below 1 λ = 850 nm W: Factor: 2 1 = 6.47 Constant: -0.054 Unit: mg/l Measuring limit: yes Lower limit: 0.5 mg/l Upper limit: 5.0 mg/l no Press function key below yes Programming of LCK 348 Phosphate Select the program VAR. Select function key below symbol »348«. Phosphate (PO4 ) (Program VAR) Display Input via keyboard Program number: for example 1 Symbol: 348 Name: PO4 LCK 348 Pro: 1 3 STA FPRG Press function key below 1 λ = 850 nm W: Factor: 2 1 = 19.84 Constant: -0.146 Unit: mg/l Measuring limit: yes Lower limit: 1.5 mg/l Upper limit: 15.0 mg/l no Press function key below yes All data entries are documented on the printer; their transfer to storage is confirmed by the printer message »stored«. You should check the printed data to ensure that all entries are correct. PA 348 - 06/1 Programming instructions CADAS 100 LPG ≥ 210 Phosphate-Phosphorus Cuvette-Test LCK 348 Page 4 ortho and total Edition 01/06 Attention! The edition date of this programming instruction must be identical to the edition date of the instruction attached to the reagents. This is the only way to ensure that your instrument will be programmed with the correct data. Please note! If you make an error during programming, you can cancel the last entry by pressing the key ➞ on the keyboard. Programming of LCK 348 Phosphorus-Pentoxide Select the program VAR. Select function key below symbol »348 P«. Phosphorus-Pentoxide (P2 O5 ) (Program VAR) Display Input via keyboard Program number: for example 1 Symbol: 348 P Name: P2 O5 LCK 348 P Pro: 1 3 STA FPRG Press function key below 1 λ = 850 nm W: Factor: 2 1 = 14.83 Constant: -0.107 Unit: mg/l Measuring limit: yes Lower limit: 1.2 mg/l Upper limit: 11.5 mg/l no Press function key below yes All data entries are documented on the printer; their transfer to storage is confirmed by the printer message »stored«. You should check the printed data to ensure that all entries are correct.
© Copyright 2026 Paperzz