PA 348 - 06/1 Cuvette-Test LCK 348 Page 1 Programming instructions CADAS 100 LPG 185 Phosphate-Phosphorus Edition 01/06 ortho and total Attention! The edition date of this programming instruction must be identical to the edition date of the instruction attached to the reagents. This is the only way to ensure that your instrument will be programmed with the correct data. Please note! If you make an error during programming, you can cancel the last entry by pressing the key ➞ on the keyboard. and L indicate the right and left ➞ ➞ ➞ The input symbols R keys respectively. Deletion of the old LCK 348 Phosphate-Phosphorus program Select the program CPRG (deletion of tests). Press function key below symbol »348 E«. Press function key below »CLEAR«. Press function key below » > « resp. » «. Return to main program. ➞ ● ● ● ● Programming of LCK 348 Phosphate-Phosphorus Select the program PRG (programming of a test, see page 1, 2 and 3). Select the program VAR (variation of a test, see page 4 and 5). Phosphate-Phosphorus (PO4-P) (Program PRG) Input via keyboard Program number: for example 1 Name: PO L 1 λ = … nm: 850 C1 = A 1 C1 = A 1 x F 1 C 1 = A 1 x F1 + A 0 C 1 = A 1 x F1 + F 2 $ 348 L ➞ L Number of measurement points: ➞ Symbol: ▼ 4- L ➞ ➞ Display P E C 1 = A 1 x F1 + F 2 + A C2 = A Factor: Factor: = 2 = -0.054 /R ➞ mg L ➞ Dimension 1 : 6.47 l Extension 1 : All data entries are documented on the printer; their transfer to storage is confirmed by the printer message »stored«. You should check the printed data to ensure that all entries are correct. PA 348 - 06/1 Programming instructions CADAS 100 LPG 185 Phosphate-Phosphorus Cuvette-Test LCK 348 Page 2 Edition 01/06 ortho and total Attention! The edition date of this programming instruction must be identical to the edition date of the instruction attached to the reagents. This is the only way to ensure that your instrument will be programmed with the correct data. Please note! If you make an error during programming, you can cancel the last entry by pressing the key ➞ on the keyboard. and L indicate the right and left ➞ ➞ ➞ The input symbols R keys respectively. Deletion of the old LCK 348 Phosphate program Select the program CPRG (deletion of tests). Press function key below symbol »348«. Press function key below »CLEAR«. Press function key below » > « resp. » «. Return to main program. ➞ ● ● ● ● Programming of LCK 348 Phosphate Select the program PRG (programming of a test, see page 1, 2 and 3). Select the program VAR (variation of a test, see page 4 and 5). Phosphate (PO4 ) (Program PRG) Input via keyboard Program number: for example 1 Name: PO L ➞ Display L Number of measurement points: 1 λ = … nm: 850 C1 = A 1 ➞ Symbol: C1 = A 1 x F 1 C 1 = A 1 x F1 + A 0 C 1 = A 1 x F1 + F 2 ▼ 4 $ 348 C 1 = A 1 x F1 + F 2 + A C2 = A Factor: Factor: = 2 = -0.146 /R ➞ mg L ➞ Dimension 1 : 19.84 l Extension 1 : All data entries are documented on the printer; their transfer to storage is confirmed by the printer message »stored«. You should check the printed data to ensure that all entries are correct. PA 348 - 06/1 Cuvette-Test LCK 348 Page 3 Programming instructions CADAS 100 LPG 185 Phosphate-Phosphorus Edition 01/06 ortho and total Attention! The edition date of this programming instruction must be identical to the edition date of the instruction attached to the reagents. This is the only way to ensure that your instrument will be programmed with the correct data. Please note! If you make an error during programming, you can cancel the last entry by pressing the key ➞ on the keyboard. and L indicate the right and left ➞ ➞ ➞ The input symbols R keys respectively. Deletion of the old LCK 348 Phosphorus-Pentoxide program Select the program CPRG (deletion of tests). Press function key below symbol »348 P«. Press function key below »CLEAR«. Press function key below » > « resp. » «. Return to main program. ➞ ● ● ● ● Programming of LCK 348 Phosphorus-Pentoxide Select the program PRG (programming of a test, see page 1, 2 and 3). Select the program VAR (variation of a test, see page 4 and 5). Phosphorus-Pentoxide (P2 O5 ) (Program PRG) Program number: for example 1 Name: P L λ = … nm: 850 C1 = A 1 C1 = A 1 x F 1 C 1 = A 1 x F1 + A 0 C 1 = A 1 x F1 + F 2 ➞ 1 $ 348 L ➞ L Number of measurement points: ➞ Symbol: ▼ 2 L ➞ Input via keyboard ➞ Display O L ▼ 5 P C 1 = A 1 x F1 + F 2 + A C2 = A Factor: Factor: = 2 = -0.107 /R ➞ mg L ➞ Dimension 1 : 14.83 l Extension 1 : All data entries are documented on the printer; their transfer to storage is confirmed by the printer message »stored«. You should check the printed data to ensure that all entries are correct. PA 348 - 06/1 Programming instructions CADAS 100 LPG 185 Phosphate-Phosphorus Cuvette-Test LCK 348 Page 4 ortho and total Edition 01/06 Attention! The edition date of this programming instruction must be identical to the edition date of the instruction attached to the reagents. This is the only way to ensure that your instrument will be programmed with the correct data. Please note! If you make an error during programming, you can cancel the last entry by pressing the key ➞ on the keyboard. Programming of LCK 348 Phosphate-Phosphorus Select the program VAR. Select function key below symbol »$ 348 E«. Phosphate-Phosphorus (PO4-P) (Program VAR) Display Input via keyboard Name: PO4-P Symbol: $ 348 E Number of measurement points: 1 λ = 850 nm C1 = A1 x F1 + F2 + A C2 = A Factor 1 = 6.47 Factor 2 = -0.054 Dimension 1 = mg/l Extension 1 = Programming of LCK 348 Phosphate Select the program VAR. Select function key below symbol »$ 348«. Phosphate (PO4 ) (Program VAR) Display Input via keyboard Name: PO4 Symbol: $ 348 Number of measurement points: 1 λ = 850 nm C1 = A1 x F1 + F2 + A C2 = A Factor 1 = 19.84 Factor 2 = -0.146 Dimension 1 = mg/l Extension 1 = All data entries are documented on the printer; their transfer to storage is confirmed by the printer message »stored«. You should check the printed data to ensure that all entries are correct. PA 348 - 06/1 Programming instructions CADAS 100 LPG 185 Phosphate-Phosphorus Cuvette-Test LCK 348 Page 5 ortho and total Edition 01/06 Attention! The edition date of this programming instruction must be identical to the edition date of the instruction attached to the reagents. This is the only way to ensure that your instrument will be programmed with the correct data. Please note! If you make an error during programming, you can cancel the last entry by pressing the key ➞ on the keyboard. Programming of LCK 348 Phosphorus-Pentoxide Select the program VAR. Select function key below symbol »$ 348 P«. Phosphorus-Pentoxide (P2 O5 ) (Program VAR) Display Input via keyboard Name: P2O5 Symbol: $ 348 P Number of measurement points: 1 λ = 850 nm C1 = A1 x F1 + F2 + A C2 = A Factor 1 = 14.83 Factor 2 = - 0.107 Dimension 1 = mg/l Extension 1 = All data entries are documented on the printer; their transfer to storage is confirmed by the printer message »stored«. You should check the printed data to ensure that all entries are correct.
© Copyright 2026 Paperzz