Wireless Remote Indicator Module (RIM) Programming including Cause and Effect Contents Section Page No 1.0 INTRODUCTION ................................................................................................... 3 2.0 ADDING A FIRECELL WIRELESS RIM TO A RADIO LOOP MODULE......................... 4 3.0 ADDING A FIRECELL WIRELESS RIM TO A RADIO HUB......................................... 6 4.0 FIRECELL CONFIGURATION TOOL PROGRAMMING............................................... 9 5.0 ADDING AND CONFIGURING A FIRECELL WIRELESS RIM TO A SETUP FILE ....... 11 6.0 CAUSE & EFFECT - LINKING A ZONE OF DEVICES TO A RIM ............................... 13 7.0 CAUSE & EFFECT - LINKING AN INDIVIDUAL DEVICE TO A RIM ......................... 17 8.0 TESTING THE RIM FUNCTIONALITY ................................................................... 21 EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 2 1.0 Introduction The following instruction details the adding of a Wireless Remote Indicator Module to a Radio Loop Module/Radio Hub and also two methods of programming the cause and effect rules on the FireCell Wireless Syncro and AS versions of control panel to: i) ii) Linking a zone of devices to a Remote Indicator Module (RIM) Link a single device to a Remote Indicator Module (RIM) The instruction has been written for engineers that have completed training on the FireCell product range and therefore have knowledge of the product and the basic programming functionality of the control panel. The instruction therefore assumes that the engineers are practised in the methodology of removing, editing and sending control panel Loop Explorer setup files to the FireCell control panel. Before starting the programming the following items must be available. • 1x Laptop with FireCell CIE programming software installed ( Loop Explorer V60020E) • 1 x FireCell control panel programming lead. Part No. FC-000-KEN EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 3 2.0 Adding a FireCell Wireless RIM to a Radio Loop Module Wireless Remote Indicator Module Battery Compartment Radio Address Section Remote Indicator Head Section Log On Button & LED Power Jumper Ident Number Remote Indicator LED To add a device onto the Loop Module, take the device in front of the Radio Loop Module. Step Action Screen Display No 1 With the Module in its normal state the screen will display: 2 Press the Rotary Control and the screen will now display: 3 Turn the Rotary Control until the screen displays: DEV00 AL00 FT00 Device Status Add New Device EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 4 4 Press the Rotary Control and the screen will now display: Press Dev Log On 5 Press the devices log on button for 2 secs (confirmation led will light on device) The screen will now display: Add Dev xxxxx N ? If the ident shown does not match the ident of the new device to be added then press the rotary control when the above Add Dev xxxxx N? display is shown. This will return the display to the previous menu. 6 Confirm the Dev ident number displayed is the same as located on the device. If correct turn the Rotary Control until the screen displays: Add Dev xxxxx Y ? 7 Press the Rotary Control and the screen will now display: Adding 8 Then the screen will display: 9 Turn the Rotary Control until the desired Address is shown; 10 Now select the address by pressing the rotary control. The screen should now display; 11 Press the Back Button to return to the normal front screen display. New Address: 002 New Address: 007 01 Added I/O DEV01 AL00 FT00 EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 5 3.0 Adding a FireCell Wireless RIM to a Radio Hub Wireless Remote Indicator Module Battery Compartment Radio Address Section Remote Indicator Head Section Log On Button & LED Power Jumper Ident Number Remote Indicator LED To add a device onto the Radio Hub, take the device in front of the Radio Hub. Step Action Screen Display No 1 With the Radio Hub in its normal state the screen will display: 2 Press the Rotary Control and the screen will now display: 3 Turn the Rotary Control until the screen displays: DEV00 AL00 FT00 Device Status Add New Device EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 6 4 Press the Rotary Control and the screen will now display available RCC’s for allocating the devices communication path: RCC01=00 Max 31 5 Turn the Rotary Control until the screen displays the required RCC to programmed the device to: RCC02=00 Max 31 6 Press the Rotary Control to select and the screen will now display: RCC02=00 Max 31 7 Press the Rotary Control and the screen will now display: 8 Turn the Rotary Control until the screen displays the required Loop to be programmed and press the Rotary control to select. 9 10 The display will now show the required address for the device to be programmed. Turn the Rotary Control until the screen displays the required address number to be programmed and press the Rotary control to select. Loop 1 Addr 001 Press Dev Log On Loop 1 Addr 001 Press Dev Log On Loop 1 Addr 001 Press Dev Log On The display will now show: Add By Log On Press Dev Log On 11 Press the Rotary Control and the screen will now display: Press Dev LogOn 12 Press the devices log on button for 2 secs (confirmation led will light on device) The screen will now display: Add Dev xxxxx N ? If the ident shown does not match the ident of the new device to be added then press the rotary control when the above Add Dev xxxxx N? display is shown. This will return the display to the previous menu. 13 Confirm the Dev ident number displayed is the same as located on the device. If correct turn the Rotary Control until the screen displays: Add Dev xxxxx Y ? EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 7 14 Press the Rotary Control and the screen will now confirm the new devices loop and address number: 15 Press the back button until the screen displays: 16 Press the Rotary Control and the screen will now display: 17 Turn the Rotary Control until the screen displays: 18 Press the Rotary Control and the screen will now display: Dev 000 of 001 19 When completed successfully the display will change to show: Done 001 of 001 New Addr L1 A001 Un-assigned Dev Device Status Assign Device Note: If unsuccessful when operation is carried out next to the Radio Hub. Re-try from steps 16-19 with the device installed in its correct location. 20 Press the Back Button to return to the normal front screen display. DEV01 AL00 FT00 The adding of the Wireless Remote Indicator Module is now complete.. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 8 4.0 FireCell Configuration Tool programming When programming the Wireless Remote Indicator Module onto a FireCell system via the configuration tool the device should be added as an Input/Output unit. All of the standard programming features for the device remain the same. Details are explained below; • To add a Wireless Remote Indicator Module to the programme Click on the I/O unit icon from the device palette as shown below: • The new device will be shown in the main window for devices allocated to an RCC. An example is shown below: • Fill in the details for the specific device requirements. below: An example is shown Devices Unique Ident Number Loop Number the device is allocated to Address Number allocated to the device EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 9 • An example of the programming of an RCC with wireless remote indicators is shown below: EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 10 5.0 Adding and Configuring a FireCell Wireless RIM to a setup file The Wireless Remote Indicator modules are added to the Loop Explorer configuration file as Input/Output devices. The selection of available FireCell devices are shown below with the Input/Output device utilised for the remote indicator module highlighted. • Double click on the icon shown above to add the remote indicator module to the setup. An example is shown below:- • Double click again on the Input/Output icon (remote indicator module) to expand the device to show the input and output. An example is shown below:- EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 11 • Double click on the Output 01 field. The display will change to show the output properties for the device. Please ensure all fields are not selected and a delay is not present. • Also ensure the Zone setting for the Output (Remote Indicator Module) corresponds with the Zone which is to cause the device to operate. An example with the correct settings and for Zone 1 operation is shown below:- Note: The Zone setting for the output device (Wireless Remote Indicator Module) is only relevant for the cause and effect when programming the unit to follow the activation of a Zone of devices. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 12 6.0 Cause & Effect - Linking a Zone of Devices to a RIM • An example is shown below for linking a Zone of devices to an individual Remote Indicator Module. In this example Zone 1 is used. Fire Alarm In Remote Indicator Module Allocated to Zone 1 Zone 1 Zone 2 Zone 2 Zone 3 etc Zone 3 etc • Click on the cause and effect icon shown below. • Click on the Action icon shown below. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 13 • The display will change to show available options for the input programming. Click on the Fire Zone Inputs icon and the display will now show individual Zones. Click on the individual Zone required and the OR/Single icon. An example below shows the settings required for Zone 1. • Click on Next when completed. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 14 • The display will change to show available options for the output programming. Click on the Fire Zone Outputs icon and the display will now show individual Zones. Click on the individual Zone required and the Continuous icon. An example below shows the settings required for Zone 1. • Click on Next when completed. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 15 • The display will change and allow a text description to be allocated for the Cause and Effect rule written. An example is shown below. • Enter the required text to identify the rule and click on Finish when completed. • The rules for the system will be displayed under the Cause and effect icon on the front display of the programme. They will be individually identifiable via the text description allocated. An example is shown below. • Repeat the above programming for each of the Wireless remote indicator modules on the system which are required to follow individual zone activations. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 16 7.0 Cause & Effect - Linking an Individual Device to a RIM • An example is shown below for linking an individual device to an individual Remote Indicator Module. In this example detection device 4 is associated with Remote Indicator Module device 6. Fire Alarm In Remote Indicator Module Allocated to Device 1 Device 2 Device 3 Device 4 Device 5 Device 6 Device 6 • Click on the cause and effect icon shown below. • Click on the Action icon shown below. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 17 • The display will change to show available options for the input programming. Click on the individual device required and the OR/Single icon. An example below shows the settings required for device 4. • Click on Next when completed. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 18 • The display will change to show available options for the output programming. Click on the individual device required (RIM) and the Continuous icon. An example below shows the settings required for remote indicator module device 6. • Click on Next when completed. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 19 • The display will change and allow a text description to be allocated for the Cause and Effect rule written. An example is shown below. • Enter the required text to identify the rule and click on Finish when completed. • The rules for the system will be displayed under the Cause and effect icon on the front display of the programme. They will be individually identifiable via the text description allocated. An example is shown below. • Repeat the above programming for each of the Wireless remote indicator modules on the system which are required to follow individual device activations. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 20 8.0 Testing the RIM functionality Following the programming of the Wireless Remote Indicator Module to the system and completion of the control panels required cause and effect programming it is recommended that the systems operation is fully tested to ensure correct operation. Below are some testing recommendations to ensure correct functionality. Cause and effect programmed for linking a Zone of devices to a Remote Indicator Module. • Activate a device into a Fire Alarm condition in a zone which also has a RIM allocated to that zone. • Ensure that the device operated into an alarm condition LED illuminates and also the RIM which is allocated to that zone LED illuminates. • Silence the Control panel. The LED’s will still be illuminated. • Reset the fire alarm condition on the control panel. The devices LED which operated into an alarm condition will extinguish and also the RIM LED which is allocated to that zone will extinguish. • Repeat the above test for each device in the Zone. On each occasion the RIM’s LED will operate and follow the operation as described above. Note: The RIM LED will only illuminate for Fire Alarm activations in the allocated Zone. The LED should not illuminate for any other activations. Cause and effect programmed for linking an Individual device to a Remote Indicator Module. • Activate a device into a Fire Alarm condition which also has a RIM allocated to that device. • Ensure that the device operated into an alarm condition LED illuminates and also the RIM which is allocated to that device LED illuminates. • Silence the Control panel. The LED’s will still be illuminated. • Reset the fire alarm condition on the control panel. The devices LED which operated into an alarm condition will extinguish and also the RIM LED which is allocated to that device will extinguish. Note: The RIM LED will only illuminate for Fire Alarm activations from the allocated device. The LED should not illuminate for any other activations. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 21 Dealer Information: EMS Group Head Office Technology House, Sea Street Herne Bay, Kent CT6 8JZ England Tel: +44 (0) 8712 710804 Fax: +44 (0) 1227 369679 Email: [email protected] The information contained within this literature is correct at time of publishing. The EMS Group reserves the right to change any information regarding products as part of its continual development enhancing new technology and reliability. The EMS Group advises that any product literature issue numbers are checked with its head office prior to any formal specifications being written. EMS Group Head Office, Technology House, Sea Street, Herne Bay, Kent CT6 8JZ, England Tel: +44 (0) 1227 369570 Fax: +44 (0) 1227 369679 Email: [email protected] Website: www.emsgroup.co.uk FireCell Remote Indicator Cause and Effect iss1.doc TSD 115 22
© Copyright 2026 Paperzz