temperzone ltd Unit Controller (UC8) - for Hydronic systems Condensate Pump and Water Valve 12V DC / 24V AC thermostat input High Medium Low Com1 Comp Heat Com2 Flow switch LP switch DC outputs & 0-10V control inputs +5V DC Fan Ground +12V DC Capacity Ground Expansion Valve Fault relay Run status Earth B A Ground RS485 #1 +12V DC B A Ground RS485 #2 0-10V out #1 Ground Dip switches 0-10V out #2 Ground Display Sump float switch DRM1 DRED DRM3 Sc (Ground) Push Button Remote on/off Ground Live Neutral High Medium Low Com3 Com4 Compressor Fan output relays 230V AC contactor Low pressure protection active HP High pressure protection active HI-t High temperature protection active LO-t Water freeze protection Circulating Capacity solenoid pump or EHC2 Display Messages (Normal Operation) Faults LP Reverse cycle valve or EHC1 UC8 X.X.X dF dELAY Name and software version (shown only after power-on) e.g. 1.5.2 Digital scroll or fixed speed compressor Unit waits for a random delay time (up to 25s, shown only after power-on) • (flashing) Normal mode - (flashing) Unit is OFF by Remote On/Off signal nO-FLO Circulating water flow protection FLOOd Sump condensate protection FROSt Indoor coil frost protection active HI-SL High suction line temperature protection active dr DRED energy consumption restriction active High discharge superheat protection active H Indoor fan High speed selection OL Overload protection active L Indoor fan Low speed selection F11 Indoor fan fault E Compressor model selection F12 Low pressure transducer fault A Modbus device Address selection F13 High pressure transducer fault F14 Suction line temperature sensor fault (SL) F15 Discharge line temperature sensor fault (DL) F18 Indoor coil temperature sensor fault (IC) F19 Hi-dSH c Commissioning mode (lasts for 30 minutes) t Test mode (lasts about 1 minute) HOLd Compressor held-on or held-off by a timer Monitoring of pressures and temperatures. Press the push button to cycle through the following options (round robin fashion): • or c sLP No temperature display (default) Suction line pressure (kPa) Et Evaporating temperature (°C) Ambient temperature sensor fault (AMB) SLt Suction line temperature (°C) F20 Superheat unknown SSH Suction side superheat (K) F21 Thermostat communication lost dLP Discharge line pressure (kPa) F22 BMS communications lost Ct Condensing temperature (°C) F26 Error reading DIP switch settings dLt Discharge line temperature (°C) F27 Invalid fan selection dSH Discharge side superheat (K) F29 High controller temperature ICEt Outdoor coil de-ice sensor temperature (°C) CAP Unit capacity (%) F30 Supply voltage out of bounds EE1 Expansion valve 1 opening (%) F32 Controller internal communication problem EE2 Expansion valve 2 opening (%) F34 Problem with pressures or transducer readings F35 Reverse cycle valve fault How to activate Special Modes • Thermostat and compressor must be OFF. F36 Invalid dip switch settings on TZT-100 thermostat F39 Variable speed compressor driver fault F40 Compression ratio too high F41 Compression ratio too low F42 Evaporating pressure / temperature too high • Available special modes are: t - Test mode H - Indoor fan high speed selection E - Compressor model selection F43 Condensing pressure / temperature too low • Release the push button as soon as the display shows the correct letter. • Press and hold pushbutton until the display shows the letter that corresponds to the special mode. Note: depending on the model some special modes may not be available. c - Commissioning mode L - Indoor fan low speed selection A - Modbus address selection 020-001-245 06/15
© Copyright 2024 Paperzz