OCTOBER, 2010 EC 97911-22 WINDOW PANNING AND TRIMS 1 GENERAL INFORMATION Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EXTERIOR PANNING • Panning is primarily used to cover the perimeters of existing building openings prior to the installation of replacement windows. The use of panning will often leave much of the existing building finishes undisturbed. • Panning may also be used in new construction, particularly to achieve an historical look. • Panning may be used with any fixed or operable Kawneer Sealair® Window Series. Panning is not recommended for use with storefront or curtain wall systems. • Standard panning profiles are available to accommodate most building conditions. • Historic or custom panning profiles may supplied based on project specific requirements. Please contact your Kawneer representative for detail assistance and associated costs. • Panning is typically supplied factory fabricated to rough opening sizes. Extended panning legs are field trimmed to fit building openings. • Exterior panning must be securely attached to the building conditions prior to the window installation. • Exterior panning legs are completely sealed to the building conditions on all perimeters. • Exterior panning is weather-stripped and sealed prior to installation of the windows. • Stainless steel retention clips are pre-attached to the exterior panning and hold the window in place until final anchoring can be completed. Retention clips are not intended to permanently secure windows in place. INTERIOR SNAP TRIM • Standard interior snap trim profiles are available to accommodate most building conditions. • Historic or custom snap trim profiles may be supplied based upon project specific requirements. Please contact your Kawneer representative for detail assistance and associated costs. • Interior snap trim is typically supplied in standard lengths and field cut to opening dimensions. Interior snap trim is attached to the window face and building condition with 3” long clips. • Interior snap trim may be used to securely anchor windows into building openings. • Windows are securely anchored to the building condition with anchors installed through the window frame, strap anchors or interior snap trim. © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. • A combination of exterior panning and interior snap trim is normally required to completely cover existing building conditions and finish the interior face of the window. kawneer.com WINDOW PANNING AND TRIMS 2 OCTOBER, 2010 TYPICAL INSTALLATION EC 97911-22 INTERIOR TRIM WINDOW DIM. WINDOW DIM. TOP OF WINDOW 1/4" DAYLITE OPENING DAYLITE OPENING 1/4" 3" LONG BASE CLIP @ 18"O.C. (NOTE: FULL LENGTH CLIPS AVAILABLE) CONTINUOUS SEAL 3" LONG BASE CLIP @ 18" O.C. BOTTOM OF WINDOW TOP OF STOOL INTERIOR TRIM INSTALLATION NOTE: BACK BED WITH SEALANT BEFORE INSTALLING WINDOW. (TYP.) WOOD BLOCKING OR SHIM AS REQUIRED VARIES MASONRY OPENING MASONRY OPENING VARIES PERIMETER SEAL PERIMETER SEAL FIELD TRIM AS REQUIRED kawneer.com © Kawneer Company, Inc., 2010 WOOD BLOCKING OR SHIM AS REQUIRED. 3/8" CLEARANCE REQUIRED FOR FASTENER. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. FIELD TRIM AS REQUIRED Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. TYPICAL PANNING AND TRIM INSTALLATION INTO EXISTING WINDOW OPENING © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2010 CLIP FOR COPED AND BUTT TYPE CORNER JOINT AT SILL kawneer.com WINDOW PANNING AND TRIMS EC 97911-22 WEATHERING AT JAMBS AND HEAD BACK SEAL CORNER JOINT BEAD OF SILICONE AT SILL SPLINE SCREW FOR COPED AND BUTT TYPE CORNER JOINT AT SILL 3 ISOMETRIC SPLINE SCREW FOR MITERED CORNER JOINT AT HEAD CLIP FOR MITERED CORNER JOINT AT HEAD BACK SEAL CORNER JOINT WINDOW RETENTION CLIP (106.4) 4-3/16" 1" 2-3/16" (55.5) WINDOW DEPTH 246-240 PANNING @ SILL (50.8) 2-3/16" (55.5) 2-3/16" 246-241 PANNING @ HEAD and JAMBS (55.5) 246-242 PANNING @ HEAD and JAMBS 1" (25.4) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1/4" (6.4) 2" TYPICAL PANNING DETAILS 246-240 PANNING @ SILL 2-3/16" (55.5) kawneer.com © Kawneer Company, Inc., 2010 (19.1) WINDOW DIM. 1/4" (6.4) WINDOW PANNING AND TRIMS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WINDOW DIM. WINDOW DIM. 3/4" (106.4) (25.4) 4-3/16" WINDOW DIM. 3" (762) 4 OCTOBER, 2010 EC 97911-22 SCALE 6" = 1' 0" (19.1) 3/4" WINDOW DEPTH (125.4) 4-15/16" © Kawneer Company, Inc., 2010 kawneer.com WINDOW DIM. (66.7) (73) WINDOW DEPTH 246-250 PANNING @ SILL WINDOW DIM. 2-5/8" (125.4) 1/4" (6.4) 1/4" (6.4) 3-7/8" (98.4) (114.3) 4-1/2" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WINDOW DIM. 2-7/8" 4-15/16" WINDOW DIM. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. OCTOBER, 2010 WINDOW PANNING AND TRIMS EC 97911-22 246-251 PANNING @ HEAD and JAMBS 2-7/8" (73) 246-250 PANNING @ SILL 4" 4" (101.6) (101.6) 5 TYPICAL PANNING DETAILS SCALE 6" = 1' 0" 4" (101.6) (101.6) 4" 246-252 PANNING @ HEAD and JAMBS 2-5/8" (66.7) WINDOW DEPTH 4-15/16" (125.4) (95.3) TYPICAL PANNING DETAILS 4" 246-253 PANNING @ HEAD and JAMBS 2-7/8" (73) 246-250 PANNING @ SILL 4" (101.6) kawneer.com © Kawneer Company, Inc., 2010 1/4" (6.4) (101.6) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WINDOW DIM. WINDOW PANNING AND TRIMS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WINDOW DIM. 3-3/4" 6 OCTOBER, 2010 EC 97911-22 SCALE 6" = 1' 0" 2-5/8" (66.7) WINDOW DEPTH kawneer.com (114.3) 4-1/2" © Kawneer Company, Inc., 2010 WINDOW DIM. Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WINDOW DIM. 1/4" (6.4) (111.1) 4-3/8" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. OCTOBER, 2010 WINDOW PANNING AND TRIMS EC 97911-22 TYPICAL PANNING DETAILS SCALE 6" = 1' 0" 5-5/16" (134.9) 246-262 PANNING @ HEAD and JAMBS 4-9/16" (115.9) 4-13/16" (122.2) 246-260 PANNING @ SILL 5-5/16" (134.9) WINDOW DEPTH 7 (114.3) 4-1/2" TYPICAL PANNING DETAILS 4-13/16" (122.2) 246-260 PANNING @ SILL 5-5/16" (134.9) kawneer.com © Kawneer Company, Inc., 2010 1/4" (6.4) 246-261 PANNING @ HEAD and JAMBS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WINDOW DIM. WINDOW PANNING AND TRIMS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. WINDOW DIM. 4-1/2" (114.3) 8 OCTOBER, 2010 EC 97911-22 SCALE 6" = 1' 0" 5-5/16" (134.9) 4-9/16" (115.9) WINDOW DEPTH kawneer.com 246-531 BASE CLIP 2-1/2" (63.5) 246-515 COVER 246-541 BASE CLIP 5" 246-550 COVER 1" 246-526 BASE CLIP (25.4) 246-505 (25.4) 246-510 COVER COVER COVER 246-506 BASE CLIP 1-3/4" (44.4) 246-530 COVER 3" (76.2) 246-540 COVER 246-551 BASE CLIP 246-600 DRYWALL ANCHOR CLIP (50.8) 2" (25.4) 246-500 246-521 BASE CLIP 1-1/4" (31.8) (25.4) (38.1) (38.1) 1" (50.8) 1-1/2" 2" 246-525 COVER 1-1/2" 246-501 BASE CLIP (25.4) 1-3/4" (44.4) WINDOW PANNING AND TRIMS (12.7) (127) (25.4) 1" EC 97911-22 1/2" 246-516 BASE CLIP 1" 1-1/2" (38.1) 028-808 #8 x 1/2" PH (25.4) 1" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1" (25.4) 1" © Kawneer Company, Inc., 2010 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. OCTOBER, 2010 9 TYPICAL TRIM DETAILS SCALE 6" = 1' 0" 1" 246-511 BASE CLIP 2" (50.8) 246-545 COVER 246-546 BASE CLIP 3-1/2" (88.9) 246-520 COVER kawneer.com © Kawneer Company, Inc., 2010 BLANK PAGE Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WINDOW PANNING AND TRIMS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 OCTOBER, 2010 EC 97911-22
© Copyright 2026 Paperzz